1.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
2.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
3.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
4.Adjuvant chemotherapy versus adjuvant concurrent chemoradiotherapy after radical surgery for early-stage cervical cancer: a randomized, non-inferiority, multicenter trial.
Danhui WENG ; Huihua XIONG ; Changkun ZHU ; Xiaoyun WAN ; Yaxia CHEN ; Xinyu WANG ; Youzhong ZHANG ; Jie JIANG ; Xi ZHANG ; Qinglei GAO ; Gang CHEN ; Hui XING ; Changyu WANG ; Kezhen LI ; Yaheng CHEN ; Yuyan MAO ; Dongxiao HU ; Zimin PAN ; Qingqin CHEN ; Baoxia CUI ; Kun SONG ; Cunjian YI ; Guangcai PENG ; Xiaobing HAN ; Ruifang AN ; Liangsheng FAN ; Wei WANG ; Tingchuan XIONG ; Yile CHEN ; Zhenzi TANG ; Lin LI ; Xingsheng YANG ; Xiaodong CHENG ; Weiguo LU ; Hui WANG ; Beihua KONG ; Xing XIE ; Ding MA
Frontiers of Medicine 2023;17(1):93-104
We conducted a prospective study to assess the non-inferiority of adjuvant chemotherapy alone versus adjuvant concurrent chemoradiotherapy (CCRT) as an alternative strategy for patients with early-stage (FIGO 2009 stage IB-IIA) cervical cancer having risk factors after surgery. The condition was assessed in terms of prognosis, adverse effects, and quality of life. This randomized trial involved nine centers across China. Eligible patients were randomized to receive adjuvant chemotherapy or CCRT after surgery. The primary end-point was progression-free survival (PFS). From December 2012 to December 2014, 337 patients were subjected to randomization. Final analysis included 329 patients, including 165 in the adjuvant chemotherapy group and 164 in the adjuvant CCRT group. The median follow-up was 72.1 months. The three-year PFS rates were both 91.9%, and the five-year OS was 90.6% versus 90.0% in adjuvant chemotherapy and CCRT groups, respectively. No significant differences were observed in the PFS or OS between groups. The adjusted HR for PFS was 0.854 (95% confidence interval 0.415-1.757; P = 0.667) favoring adjuvant chemotherapy, excluding the predefined non-inferiority boundary of 1.9. The chemotherapy group showed a tendency toward good quality of life. In comparison with post-operative adjuvant CCRT, adjuvant chemotherapy treatment showed non-inferior efficacy in patients with early-stage cervical cancer having pathological risk factors. Adjuvant chemotherapy alone is a favorable alternative post-operative treatment.
Female
;
Humans
;
Uterine Cervical Neoplasms/drug therapy*
;
Prospective Studies
;
Quality of Life
;
Neoplasm Staging
;
Chemoradiotherapy
;
Chemotherapy, Adjuvant/adverse effects*
;
Adjuvants, Immunologic
;
Antineoplastic Combined Chemotherapy Protocols/therapeutic use*
;
Retrospective Studies
5.Establishment of a real-time fluorescent quantitative RT-PCR rapid detection method for human astrovirus
Yue DU ; Sai TIAN ; Yinxia LI ; Hongbo LIU ; Shaofu QIU ; Guangcai DUAN
Chinese Journal of Microbiology and Immunology 2021;41(3):195-200
Objective:To establish a rapid detection method for human astrovirus based on TaqMan-probe real-time fluorescent quantitative reverse transcription-polymerase chain reaction (RT-PCR).Methods:According to the conservative sequence of human astrovirus ORF1 b gene, we designed the amplification primers and specific fluorescent probe to establish the human astrovirus TaqMan real-time fluorescent quantitative RT-PCR rapid detection method. The specificity, sensitivity and stability of the method were evaluated. We also used this method to detect human astrovirus in clinical samples. Results:The established human astrovirus TaqMan real-time fluorescent quantitative RT-PCR detection method has good specificity and repeatability for human astrovirus, and the sensitivity can reach 10 2 copies/μl. After testing the clinical samples, the detection rate of human astrovirus by our method was 100%. Conclusions:The human astrovirus TaqMan real-time fluorescent quantitative RT-PCR detection method established in this study is simple, rapid, sensitive, specific and stable. It can be used for clinical human astrovirus detection and epidemiological investigation.
6. The preliminary analysis on the characteristics of the cluster for the Corona Virus Disease
Haiyan YANG ; Jie XU ; Yan LI ; Xuan LIANG ; Yuefei JIN ; Shuaiyin CHEN ; Rongguang ZHANG ; Weidong ZHANG ; Guangcai DUAN
Chinese Journal of Epidemiology 2020;41(0):623-628
Since December 2019, Corona Virus Disease (COVID-19), a new emerging infection disease occurred in Wuhan, has spread in 27 countries and regions. The clusters of many cases were reported with the epidemic progresses. We collected currently available information for 377 COVID-19 clusters (1 719 cases), excluded the hospital clusters and Hubei cases, during the period from January 1, 2020 to February 20, 2020. There were 297 family clusters (79%), case median 4; 39 clusters of dining (10%), case median 5; 23 clusters of shopping malls or supermarkets (6%), case median 13; 12 clusters of work units (3%), case median 6, and 6 clusters of transportation. We selected 325 cases to estimate the incubation period and found its range is 1 to 20 days, median was 7 days, and mode was 4 days. The analysis of the epidemic situation in a department store in China indicates that there is a possibility of patients as the source of infection during the incubation period of the epidemic. From February 5, 2020 to February 21, 2020, 634 persons were infected in the Diamond Princess Liner. All persons are susceptible to SARS-CoV-2. The older, patients during the incubation period and the worse environment may be the cause of the cases rising. The progress of the two typical outbreaks clearly demonstrates the spread of the early cases in Wuhan. Whatever happens, screening and isolating close contacts remains essential except for clinical treatment during the epidemic. Especially for the healthy people in the epidemic area, isolation is the key.
7.Epidemiological investigation of hypertension and its control on maintenance hemodialysis patients in Anhui province
Lei YE ; Yangyang HUANG ; Guangrong QIAN ; Weidong CHEN ; Chengfu WANG ; Jiuhuai HAN ; Bin HU ; Zhi LIU ; Runzhi SHUI ; Ligang LIU ; Xiuyong LI ; Guangcai SHI ; Wei WANG ; Youwei BAI ; Shengyin MA ; Jianghuai ZHANG ; Peng HAN ; Huaiqing WANG ; Jiande CHEN ; Bin HU ; Bengui SUN ; Liping YE ; Suhang WANG ; Jinru WANG ; Kaipeng LI ; Lei CHEN ; Li HAO ; Deguang WANG
Chinese Journal of Nephrology 2018;34(1):17-23
Objective To understand the prevalence,treatment and influence factors of hypertension in maintenance hemodialysis (MHD) patients in Anhui Province.Methods A total of 2724 adult patients on MHD from January 1st 2014 to March 31st 2014 in 26 hospitals of southern,northern and central Anhui Province were investigated.Their demographic characteristics,primary disease,complications,medications,dialysis and laboratory examination were explored.The prevalence treatment rate and control rate of hypertension were analyzed.Associated factors for controlling hypertension [systolic blood pressure (SBP) < 140 mmHg and diastolic blood pressure (DBP) < 90 mmHg] were assessed by logistic regression analysis.Results (1) The prevalence of hypertension in the hemodialysis patients was 87.0%.Their treatment rate and control rate were 93.2% and 23.9% respectively.The average of SBP was (145.90±21.18) mmHg,and the DBP on average was (83.60± 12.21) mmHg.The most commonly used anti-hypertensive drug is calcium channel blocker (88.2%).Over one third (45.7%) of patients were treated with two kinds of anti-hypertensive drug,26.2% with 1 kind,21.7% with 3 kinds,and 6.4% with 4 kinds or more.(2) Compared with non-hypertension patients,patients with hypertension have older age,higher body mass index (BMI),phosphorus,SBP and DBP,as well as lower hemoglobin and Kt/V (all P < 0.05).(3) The multivariate logistic regression analysis showed that Ca > 2.50 mmol/L (OR=2.084,95%CI 1.008-4.307,P=0.047) positively correlated with controlling hypertension,while smoke (OR=0.594,95%CI 0.356-0.911,P=0.046) and BMI 18.5 ~ 23.9 kg/m2 (OR=0.516,95%CI 0.293-0.907,P=0.022) negatively correlated with it.Conclusions High prevalence yet low control rate of hypertension in MHD patients in Anhui Province were observed.Hypocalcemia may be a protective factor for hypertension control,while smoke and BMI may be risk factors for it.
8.MRI Manifestations After the Death of SD Rat Model Due to Cerebral Infarction
Deyin ZENG ; Guangcai TANG ; Guangxiang CHEN ; Cao LI ; Xiaopeng HE
Chinese Journal of Medical Imaging 2018;26(3):171-174
Purpose To perform MRI examination after the death of SD rat model due to cerebral infarction and to investigate the changing characteristics of cerebral infarction during postmortem examination. Materials and Methods Middle cerebral artery occlusion (MCAO) model was established on 21 SD rats by applying modified suture method. 13 to 56 h after modeling, 12 dead SD rats were collected for the experiment. The bodies were stored at an environment with a temperature of 10-15°C and relative humidity of 45%-55%. Head MRI was performed 12 h after modeling and at 8, 24, 48, 72 and 96 h after death respectively, and apparent diffusion coefficient (ADC) values of infarction and contralateral brain tissue were calculated. At each post-mortem time point, ADC values of bilateral cerebral hemispheres, ADC values of infarction and living infarction, and ADC values of non-infarcted brain and living non-infarcted zone were compared. Brain tissue was taken after scan for pathological diagnosis and compared with diagnostic results of postmortem MRI (pmMRI). Results The right cerebral signal of rats was abnormal 12 h after cerebral infarction and after death. Eight rats were found to have shifted cerebral middle-line structure to the left. ADC values of infarction at each time point after death were lower than that of non-infarction, the difference of which was statistically significant (P<0.05); ADC values of infarction were lower than that of living infarction, the difference of which was statistically significant (P<0.05); ADC value of non-infarcted area at each time point was lower than that of living non-infarcted area, the difference of which was statistically significant (P<0.05). Necrosis and disintegration of neurons, disintegration and liquefaction of glial fibers, infiltration of inflammatory cells and leakage of red blood cells were spotted in necrotic areas after receiving cerebral HE staining in rat. HE staining was consistent with the infarction zone indicated by pmMRI. Conclusion pmMRI can be used for the diagnosis of cerebral infarction via virtual necropsy.
9.The ECG tube current modulation technique of dual source CT in clinical application of coronary angiography
Guangfang TUO ; Yongshu LAN ; Guangcai TANG ; Zhenlin LI ; Lu ZHENG
Journal of Practical Radiology 2016;32(8):1289-1292
Objective To explore the application value of ECG tube current modulation technology of dual source CT in coronary angiography,compared with retrospectively ECG-gated technique.Methods 200 patients were randomly divided into ECG tube current modulation group (Group A)and retrospectively ECG-gated group(Group B).In Group A,the main parameters were the exposure time windows of full dose,which were set according to different heart rates.χ2 test was adopted in the subjective score,and t test was used in the objective score and radiation dose.Results There was no statistical significance in image quality between the two groups(χ2 =2.125,tnoise =-0.557,P >0.05 );The effective dose (ED)of Group A and Group B were (3.30±0.40)mSv and(6.90±1.76)mSv,respectively.The difference was statistically significant (t ED =-1 9.954,P <0.05).The radiation dosage of Group A was 52% lower than that of Group B.Conclu-sion Compared with retrospectively ECG-gated technique,the ECG tube current modulation technique ensures the image quality, and at the same time it can significantly reduce the radiation dose,therefore,it can be used as a routine examination technique of cor-onary angiography.
10.Diagnostic value of 18 F-NaF PET/CT and MRI in detecting skull-base bone invasion of nasopharyn-geal carcinoma
Yali LE ; Yu CHEN ; Yue CHEN ; Zhanwen HUANG ; Jingbo WU ; Dongmei ZHAO ; Li ZHANG ; Guangcai TANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2016;(1):34-38
Objective To evaluate the value of 18 F?NaF PET/CT and MRI in the diagnosis of skull?base bone invasion ( SBBI) in patients with nasopharyngeal carcinoma( NPC) . Methods Sixty?three NPC patients (45 males, 18 females;age range 23-72 years) were enrolled in this prospective study. Pa?tients underwent 18 F?NaF PET/CT and MRI to confirm whether the skull base was invaded. The reference standard was based on the follow?up imaging in 6 months. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the two imaging modalities were calculated. χ2 test was used to analyze their difference. The SBBI foci and their distribution detected by the two imaging modalities were compared. Results Thirty?four NPC patients demonstrated SBBI in follow?up imaging. The diagnostic sen?sitivity, specificity, positive predictive value, negative predictive value, and accuracy of 18 F?NaF PET/CT were 97.1%(33/34), 89.7%(26/29), 91.7%(33/36), 96.3%(26/27) and 93.7%(59/63), respective?ly. For MRI, the parameters were 91.2%(31/34), 86.2%(25/29), 88.6%(31/35), 89.3%(25/28) and 88.9%(56/63), respectively. The diagnostic efficiency of the two imaging modalities had no significant difference (χ2=0.162-1.062, all P>0.05) . 18 F?NaF PET/CT detected 133 lesions and MRI detected 97 le? sions, and the clivus was the most common site of SBBI. Conclusions 18 F?NaF PET/CT and MRI have similar diagnostic efficiency in detecting SBBI. 18 F?NaF PET/CT can detect more lesions than MRI do, and has potential advantage for detecting tiny bone lesions in skull base.

Result Analysis
Print
Save
E-mail