1.A Simple and Nonenzymatic Method to Isolate Human Corpus Cavernosum Endothelial Cells and Pericytes for the Study of Erectile Dysfunction
Guo Nan YIN ; Jiyeon OCK ; Min Ji CHOI ; Kang Moon SONG ; Kalyan GHATAK ; Nguyen Nhat MINH ; Mi Hye KWON ; Do Hwan SEONG ; Hai Rong JIN ; Ji Kan RYU ; Jun Kyu SUH
The World Journal of Men's Health 2020;38(1):123-131
2.Finite element analysis of long-term changes of the breast after augmentation mammoplasty: Implications for implant design
Yujin MYUNG ; Jong Gu LEE ; Maenghyo CHO ; Chan Yeong HEO
Archives of Plastic Surgery 2019;46(4):386-389
The development of breast implant technology continues to evolve over time, but changes in breast shape after implantation have not been fully elucidated. Thus, we performed computerized finite element analysis in order to better understand the trajectory of changes and stress variation after breast implantation. The finite element analysis of changes in breast shape involved two components: a static analysis of the position where the implant is inserted, and a dynamic analysis of the downward pressure applied in the direction of gravity during physical activity. Through this finite element analysis, in terms of extrinsic changes, it was found that the dimensions of the breast implant and the position of the top-point did not directly correspond to the trajectory of changes in the breast after implantation. In addition, in terms of internal changes, static and dynamic analysis showed that implants with a lower top-point led to an increased amount of stress applied to the lower thorax. The maximum stress values were 1.6 to 2 times larger in the dynamic analysis than in the static analysis. This finding has important implications for plastic surgeons who are concerned with long-term changes or side effects, such as bottoming-out, after anatomic implant placement.
Breast Implantation
;
Breast Implants
;
Breast
;
Computer Simulation
;
Female
;
Finite Element Analysis
;
Gravitation
;
Mammaplasty
;
Motor Activity
;
Plastics
;
Surgeons
;
Thorax
3.Standard Recipes for the Preparation of Thickened Barium Liquids Used in the Diagnosis of Dysphagia
Jaechun PARK ; Whachun YOO ; Byoungseung YOO
Clinical Nutrition Research 2019;8(4):265-271
Barium sulfate is commonly used to prepare contrast media for videofluorograpy. The flow characteristics of thickened liquids formulated for oropharyngeal imaging are known to be greatly affected by the addition of barium. In this study, thickened barium liquids were prepared by mixing a commercial xanthan gum (XG)-based thickener (Visco-up®) at different concentrations (0.1%–3.0%) with barium powder (Baritop HD®), and differences in the viscosity between thickened non-barium and thickened barium liquids were investigated. In addition, the thickness levels of thickened barium liquids, which are based on the National Dysphagia Diet (NDD) and International Dysphagia Diet Standardization Initiative (IDDSI) guidelines, were classified by measuring the viscosity (NDD) and gravity flow through a syringe (IDDSI) with 0.1%–3.0% thickener concentrations. The apparent viscosity (η(a),₅₀) values of thickened barium liquids were much higher than those of thickened non-barium liquids, indicating that the addition of barium to the XG-based thickener resulted in further thickening. Standard recipes for preparing thickened barium liquids with desirable thickness levels were also established, showing the different thickener concentrations corresponding to the different NDD and IDDSI levels.
Aphasia
;
Barium Sulfate
;
Barium
;
Contrast Media
;
Deglutition Disorders
;
Diagnosis
;
Diet
;
Gingiva
;
Gravitation
;
Syringes
;
Viscosity
4.Effects of Virtual Reality Horse Riding Simulator Training Using a Head-Mounted Display on Balance and Gait Functions in Children with Cerebral Palsy: A Preliminary Pilot Study
Hae Won KIM ; Ki Seok NAM ; Sung Min SON
Journal of Korean Physical Therapy 2019;31(5):273-278
PURPOSE: The purpose of this study was to investigate the effects of three-dimensional virtual reality horse riding simulator training using a head-mounted display on gait and balance in children with cerebral palsy.METHODS: Ten children with cerebral palsy were randomly assigned to the horse riding simulator (HRS) group (n=5) or the horse riding simulator with virtual reality (HRSVR) group (n=5). To evaluate balance, center of gravity (COG) sway velocity and total sway distance of each group were assessed using the Wii balance board, and gait speed and stride length of each group were assessed using a gait analysis system.RESULTS: Intra-group comparisons between pre- and post-intervention measures revealed that there were significant changes in all gait and balance variables such as stride length, gait velocity, COG sway velocity and COG sway distance in the HRSVR group (p<0.05). In the HRS group, there were significant changes in all variables except stride length (p<0.05). In addition, inter-group comparisons showed significant differences between the two groups in stride length, gait velocity and COG sway distance except COG sway velocity (p<0.05).CONCLUSION: The findings of this study suggest that horse riding simulator training combined with 3D virtual reality can be a new positive therapeutic approach for improving functional performance in children with cerebral palsy.
Cerebral Palsy
;
Child
;
Gait
;
Gravitation
;
Horses
;
Humans
;
Pilot Projects
5.Points to consider before the insertion of maxillary implants: the otolaryngologist's perspective
Sung Won KIM ; Il Hwan LEE ; Soo Whan KIM ; Do Hyun KIM
Journal of Periodontal & Implant Science 2019;49(6):346-354
Maxillary implants are inserted in the upward direction, meaning that they oppose gravity, and achieving stable support is difficult if the alveolar bone facing the maxillary sinus is thin. Correspondingly, several sinus-lifting procedures conducted with or without bone graft materials have been used to place implants in the posterior area of the maxilla. Even with these procedures available, it has been reported that in about 5% of cases, complications occurred after implantation, including acute and chronic sinusitis, penetration of the sinus by the implant, implant dislocation, oroantral fistula formation, infection, bone graft dislocation, foreign-body reaction, Schneiderian membrane perforation, and ostium plugging by a dislodged bone graft. This review summarizes common maxillary sinus pathologies related to implants and suggests an appropriate management plan for patients requiring dental implantation.
Dental Implantation
;
Dental Implants
;
Dislocations
;
Foreign-Body Reaction
;
Gravitation
;
Humans
;
Maxilla
;
Maxillary Sinus
;
Maxillary Sinusitis
;
Nasal Mucosa
;
Oroantral Fistula
;
Pathology
;
Postoperative Complications
;
Sinusitis
;
Transplants
6.Pulmonary aspiration during intubation in a high-risk patient: A video clip and clinical implications
Gi Ho KOH ; Sung Hoon KIM ; Hyo Jung SON ; Jun Young JO ; Seong Soo CHOI ; Se Ung PARK ; Wook Jong KIM ; Seung Woo KU
Journal of Dental Anesthesia and Pain Medicine 2018;18(2):111-114
We report a case of pulmonary aspiration during induction of general anesthesia in a patient who was status post esophagectomy. Sudden, unexpected aspiration occurred even though the patient had fasted adequately (over 13 hours) and received rapid sequence anesthesia induction. Since during esophagectomy, the lower esophageal sphincter is excised, stomach vagal innervation is lost, and the stomach is flaccid, draining only by gravity, the patient becomes vulnerable to aspiration. As the incidence of perioperative pulmonary aspiration is relatively low, precautions to prevent aspiration tend to be overlooked. We present a video clip showing pulmonary aspiration and discuss the literature concerning the risk of aspiration and its preventive strategies.
Anesthesia
;
Anesthesia, General
;
Esophageal Sphincter, Lower
;
Esophagectomy
;
Gravitation
;
Humans
;
Hypopharyngeal Neoplasms
;
Incidence
;
Intubation
;
Respiratory Aspiration
;
Stomach
7.Immediate Effect of Postural Control of the Contra-Lateral Side on Exercise-Induced Fatigue of the Ipsi-Lateral Plantar Flexor Muscle.
Journal of Korean Physical Therapy 2018;30(2):63-66
PURPOSE: The purpose of the current study was to examine the effects of exercise-induced fatigue of the plantar flexor muscle in the dominant ankle on the plantar flexor strength and postural control function of the contra-lateral side. METHODS: Twenty-one young adults (male: 10, female: 11) volunteered to participate in this study. An exercise-induced fatigue protocol to induce fatigue was performed in the plantar flexor of the dominant ankle. For the fatigue protocol, the participants were instructed to raise their heels as high as possible in the position with one leg stance of the dominant lower limb, and the heel was then downed after holding for 1 second. The muscle strength of the contra-lateral plantar flexor was measured using a digital muscle strength test device, and the static and dynamic postural control were tested by acquiring the center of gravity velocity while performing one leg standing. A paired t-test was used to identify the differences between the pre- and post, and the data were analyzed using SPSS 12.0 software. RESULTS: Comparison of the pre- and post-test data revealed a significant difference in the plantar flexor strength and dynamic postural control after exercise-induced muscle fatigue in the dominant side. On the other hand, there was no significant difference in the static postural control. CONCLUSION: These findings have practical implications, suggesting that unilateral muscle fatigue affects the ankle muscle strength and postural ability of the contralateral side.
Ankle
;
Fatigue*
;
Female
;
Gravitation
;
Hand
;
Heel
;
Humans
;
Leg
;
Lower Extremity
;
Muscle Fatigue
;
Muscle Strength
;
Young Adult
8.Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.
Tuberculosis and Respiratory Diseases 2018;81(2):106-115
Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity (“water seal”) drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established.
Catheters
;
Chest Tubes*
;
Drainage*
;
Gravitation
;
Hemothorax
;
Humans
;
Palliative Care
;
Pleura
;
Pleural Cavity
;
Pleural Effusion
;
Pleural Effusion, Malignant
;
Pleurodesis
;
Pneumothorax
;
Pulmonary Edema
;
Suction
;
Surgical Instruments
;
Thorax*
;
Ultrasonography
;
Vacuum
9.Prediction of air inflow during central venous catheter insertion: experimental study.
Hyo Jae JUNG ; Yang Weon KIM ; Chang Min PARK ; Chul Ho PARK ; Ji Hun KANG ; Yoo Sang YOON
Journal of the Korean Society of Emergency Medicine 2018;29(6):641-648
OBJECTIVE: This study examined the incidence and amount of air inflow during central venous catheter (CVC) insertion. METHODS: This study was an experimental study aimed at designing an apparatus to implement blood vessel and blood flow in the human body. A 1.5-m long core tube with a Teflon tube, suction rubber tube, and polyvinyl chloride tube were made. This core tube was assumed to be the blood vessel of the human body. Blood was replaced with a saline solution. The saline solution was placed higher than the core tube and flowed into the inside of the tube by gravity. The CVC was injected 15-cm deep into the core tube. The air was collected through a 3-way valve into the upper tube. The experiments were carried out by differentiating the pressure in the tube, CVC insertion step, and diameter of the end of the catheter. The experiment was repeated 10 times under the same conditions. RESULTS: The amount of air decreased with increasing pressure applied to the tube. Air was not generated when the syringe needle was injected, and the amount of air increased with increasing size of the distal end catheter. CONCLUSION: To minimize the possibility of air embolism, it is necessary to close the distal end catheter at the earliest point as soon as possible.
Blood Vessels
;
Catheters
;
Central Venous Catheters*
;
Embolism, Air
;
Gravitation
;
Human Body
;
Incidence
;
Jugular Veins
;
Needles
;
Polytetrafluoroethylene
;
Polyvinyl Chloride
;
Rubber
;
Sodium Chloride
;
Suction
;
Syringes
10.Identification of Vestibular Organ Originated Information on Spatial Memory in Mice
Gyu Cheol HAN ; Minbum KIM ; Mi Joo KIM
Journal of the Korean Balance Society 2018;17(4):134-141
OBJECTIVES: We aimed to study the role of vestibular input on spatial memory performance in mice that had undergone bilateral surgical labyrinthectomy, semicircular canal (SCC) occlusion and 4G hypergravity exposure. METHODS: Twelve to 16 weeks old ICR mice (n=30) were used for the experiment. The experimental group divided into 3 groups. One group had undergone bilateral chemical labyrinthectomy, and the other group had performed SCC occlusion surgery, and the last group was exposed to 4G hypergravity for 2 weeks. The movement of mice was recorded using camera in Y maze which had 3 radial arms (35 cm long, 7 cm high, 10 cm wide). We counted the number of visiting arms and analyzed the information of arm selection using program we developed before and after procedure. RESULTS: The bilateral labyrinthectomy group which semicircular canal and otolithic function was impaired showed low behavioral performance and spacial memory. The semicircular canal occlusion with CO₂ laser group which only semicircular canal function was impaired showed no difference in performance activity and spatial memory. However the hypergravity exposure group in which only otolithic function impaired showed spatial memory function was affected but the behavioral performance was spared. The impairment of spatial memory recovered after a few days after exposure in hypergravity group. CONCLUSIONS: This spatial memory function was affected by bilateral vestibular loss. Space-related information processing seems to be determined by otolithic organ information rather than semicircular canals. Due to otolithic function impairment, spatial learning was impaired after exposure to gravity changes in animals and this impaired performance was compensated after normal gravity exposure.
Animals
;
Arm
;
Automatic Data Processing
;
Gravitation
;
Hypergravity
;
Memory
;
Mice
;
Mice, Inbred ICR
;
Otolithic Membrane
;
Semicircular Canals
;
Spatial Learning
;
Spatial Memory

Result Analysis
Print
Save
E-mail