1.Application of ultrasound in differential diagnosis of cystic biliary atresia and choledochal cyst in infants
Yujie HU ; Ting XIAO ; Feixiang XIANG ; Yao DENG ; Yunchao CHEN ; Mingxing XIE ; Cheng YU
Journal of Chinese Physician 2024;26(10):1456-1459
		                        		
		                        			
		                        			Objective:To evaluate the value of ultrasonography in the differential diagnosis of cystic biliary atresia (CBA) and choledochal cyst (CC) in infants.Methods:CBA or CC children <3 months of age diagnosed by surgery in Union Hospital, Tongji Medical College, Huazhong University of Science and Technology from 2015 to 2023 were collected, and the differences in general conditions and ultrasound manifestations between CBA group and CC group were retrospectively analyzed.Results:Among the 55 children, 30 were in CBA group and 25 were in CC group. The mean length diameter and width diameter of cysts in the CBA group were about (1.45±1.05)cm and (1.04±0.73)cm, respectively, which were significantly smaller than those in the CC group (5.41±2.98)cm and (3.21±2.90)cm ( P<0.001). The incidence of fibrous plaque (50.0%, 15/30) and abnormal gallbladder morphology (73.3%, 22/30) in the CBA group was significantly higher than that in the CC group [4.0%(1/25) and 16.0%(4/25), respectively]. The incidence of intrahepatic biliary mud deposition (52.0%, 13/25) and intrahepatic biliary duct dilation (64.0%, 16/25) in the CC group was significantly higher than that in the CBA group [0, 3.3%(1/30), respectively]. Conclusions:There are some differences in ultrasonography between CBA and CC children. The length and width of cysts in children with CC are significantly larger than those in children with CBA, and biliary mud deposits or intrahepatic bile duct dilatation are seen in the cysts. The incidence of fibrous plaque and abnormal gallbladder morphology in CBA children is significantly higher than that in CC children.
		                        		
		                        		
		                        		
		                        	
2.Construction of evaluation index system of core competence of neonatal specialist nurses
Kongjia QIAN ; Hongzhen XU ; Xiaoying CHENG ; Feixiang LUO ; Yafeng FANG ; Lianjuan ZHOU ; Jun YU ; Hongqin ZHOU ; Shuohui CHEN ; Jihua ZHU
Chinese Journal of Practical Nursing 2023;39(1):46-52
		                        		
		                        			
		                        			Objective:To construct the evaluation index system of the core competence of neonatal specialist nurses, so as to provide reference for clinical training of neonatal specialist nurses.Methods:From January 2020, through literature review, theoretical analysis, interview, Delphi method and superiority chart, the evaluation index and weight of core competence of neonatal specialist nurses were determined.Results:Totally 28 experts in China were invited for 3 rounds of consultation. The effective recovery rate of the questionnaires was 93.33%(28/30) in the first round. The effective recovery rate of the questionnaires was 100.00%(28/28) in the second and third rounds. The authority coefficient of the experts was 0.85 in the third round. The Kendall′s coefficients of concordance of the first-level indexes, second-level indexes and third-level indexes were 0.150, 0.221 and 0.161, respectively. The final evaluation index system of the core competence of neonatal specialist nurses included 5 first-level indicators, 17 second-level indicators and 58 third-level indicators.Conclusions:The evaluation index system of the core competence of neonatal specialist nurses constructed in this study has certain scientific, reliable and clinical application value, which is conducive to the training of newborn specialized nurses in China.
		                        		
		                        		
		                        		
		                        	
3.Comparison of ultrasound-guided percutaneous fascia dilatation with one-step and multi-step percutaneous renal dilatation on renal injury in pigs
Yilian DUAN ; Xinliang GUO ; Cheng YU ; Wen ZHANG ; Mengyun YAO ; Feixiang XIANG
Journal of Chinese Physician 2022;24(9):1285-1289
		                        		
		                        			
		                        			Objective:To evaluate the renal injury of ultrasound-guided percutaneous fascia dilatation with one-step and multi-step percutaneous renal dilatation on renal injury in pigs.Methods:20 experimental pigs were randomly divided into 16F group and 24F group, with 10 pigs in each group. Under the guidance of ultrasound, the left and right kidneys of each experimental pig in group 16F were expanded by percutaneous renal multi-step expansion and one-step expansion (multi-step dilation subgroup and one-step dilation subgroup respectively) with 16F expander, and the same operation was performed with 24F expander in 24F group. After the operation, the left and right kidneys were left with fistula tubes for 1 week. The duration of hematuria in the renal fistula tubes was observed and compared. One month later, the experimental pigs were killed and the kidneys were removed. The histopathology of each group was observed under the naked eye and microscope. The scar tissue around the nephrostomy channel was removed, and hematoxylin-eosin (HE) and Masson staining were performed respectively. The scar volume was measured by digital image analysis technology, and the percentage of the scar volume in the renal cortex volume was calculated.Results:There was no significant difference in gross hematuria duration between one-step dilation subgroup [(4.60±1.26)d] versus multi-step dilation subgroup [(4.70±1.17)d] of 16F group ( P>0.05); There was no significant difference in gross hematuria duration between one-step dilation subgroup [(5.40±1.25)d] versus multi-step dilation subgroup [(5.50±1.08)d] of the 24F group ( P>0.05). There was no significant difference in the gross and histological observation of pig kidney specimens in 16F group and 24F group. There was no significant difference in the scar volume of the fistula channel [(0.35±0.04)cm 3, (0.36±0.03)cm 3] and its percentage in the whole renal cortical volume [(0.41±0.05)%, (0.41±0.06)%] between one-step dilation subgroup versus multi-step dilation subgroup of 16F group (all P>0.05); there was no significant difference in the scar volume of the fistula channel [(0.48±0.02)cm 3, (0.49±0.04)cm 3] and its percentage in the whole renal cortical volume [(0.52±0.04)%, (0.53±0.07)%] between one-step dilation subgroup versus multi-step dilation subgroup of 24F group (all P>0.05). The scar volume and its percentage in the whole renal cortical volume of the one-step dilation subgroup and the multi-step dilation subgroup in the 24F group were higher than that of the 16F group, with statistically significant difference (all P<0.05). Conclusions:Both one-step and multi-step percutaneous renal dilatation have less damage to renal parenchyma. The multi-step dilatation has no obvious advantage over one-step dilatation in reducing renal parenchyma injury.
		                        		
		                        		
		                        		
		                        	
4.Application of high frequency ultrasound in the diagnosis of closed penile cavernous rupture
Gongqun SHANG ; Cheng YU ; Yuman LI ; Mingxing XIE ; Jing WANG ; Li ZHANG ; Feixiang XIANG
Journal of Chinese Physician 2022;24(9):1294-1297
		                        		
		                        			
		                        			Objective:To explore the diagnostic value of high frequency ultrasound in the diagnosis of closed penile cavernous rupture.Methods:The ultrasonic examination data of 8 patients with closed penile cavernous rupture treated in Union Medical College Affiliated to Tongji Medical College of Huazhong University of Science and Technology from August 2016 to May 2021 were retrospectively analyzed, and the high-frequency ultrasonic image features were analyzed.Results:Among the 8 patients with closed penile cavernous rupture, 6 were located at the distal end of the corpus cavernosum, one was located at the middle of the corpus cavernosum, and one was located at the proximal end of the corpus cavernosum. All of them were unilateral penile cavernosum rupture, 3 on the left side and 5 on the right side. In all 8 cases, the white membrane of the corpus cavernosum of the penis was continuously interrupted, and the broken end could be clearly displayed. The largest white membrane breach was 16.1 mm, and the smallest was 2.1 mm. Hematoma formed around the rupture of the tunica albuginea of the penis corpus cavernosum, and the maximum range of hematoma was 40.3 mm×15.4 mm, the minimum range of hematoma was 7.9 mm×5.6 mm.Conclusions:High frequency ultrasound is convenient, rapid and accurate, and can be used as the first choice of auxiliary examination for closed penile cavernous rupture.
		                        		
		                        		
		                        		
		                        	
5.Conventional ultrasound and contrast-enhanced ultrasound for diagnosis of left internal jugular venous vein pseudo-aneurysm: a case report and literature review
Gongqun SHANG ; Cheng YU ; Yao DENG ; Yilian DUAN ; Yongxing ZHANG ; Mingxing XIE ; Jing WANG ; Li ZHANG ; Feixiang XIANG
Journal of Chinese Physician 2021;23(4):497-501
		                        		
		                        			
		                        			Objective:To investigate the ultrasonographic features of internal jugular venous vein pseudo-aneurysm.Methods:The ultrasonographic and clinical features of a patient with internal jugular venous vein pseudo-aneurysm in Union Hospital Affiliated to Huazhong University of Science and Technology were retrospectively analyzed. These characteristics of this patient combined with cases from literatures were summarized.Results:Ultrasound showed that the 38.6 mm×14.0 mm×29.9 mm anechoic area in the soft tissue layer of the left neck communicated with the left internal jugular vein through the 3.8 mm wide breach, and a 12.9 mm×6.6 mm slightly hyperechoic mass was found in the anechoic area. Color Doppler flow imaging showed that the internal jugular vein communicated with the anechoic area through the crevasse. There was no obvious blood flow signal in slightly hyperechoic mass. The bidirectional burr-like blood flow signal could be detected by pulse-wave Doppler. Contrast enhanced ultrasound showed that the contrast agent flowed into the mass from the internal jugular vein through the breach, and the slightly hyperechoic mass appeared the contrast filling defect, and contrast agent was well filled in the rest of the anechoic area. Ultrasound diagnosis: left internal jugular vein pseudoaneurysm with thrombosis. 35 cases of cervical vein pseudo-aneurysm patients were finally included in 23 documents, including 12 males, 23 females, 15 cases on the left side, 20 cases on the right side, 6 cases of the internal jugular vein, 27 cases of the external jugular vein; one case only describes the neck veins and supraclavicular vein in another one case. Among them, 34 cases showed subcutaneous anechoic masses on ultrasound, 1 case showed slightly hyperechoic masses, and 35 cases showed venous wall breaches.Conclusions:Ultrasound examination has high diagnostic value for vein pseudo-aneurysm owing to its convenience, fast and serial observation. Therefore, it is the preferred method and can be widely used in clinical practice. Contrast-enhanced ultrasound can clearly show the blood perfusion, and help to improve the diagnostic confidence of the operator.
		                        		
		                        		
		                        		
		                        	
6.Real-time shear wave elastography in differential diagnosis of benign and malignant thyroid nodules
Yue SONG ; Mingxing XIE ; Jing WANG ; Feixiang XIANG ; Cheng YU ; Dan ZHANG ; Juan CHEN
Journal of Chinese Physician 2019;21(3):324-326,330
		                        		
		                        			
		                        			Objective This study aimed to discuss the performance and impact factors of shear wave elastography (SWE) for differential diagnosis of thyroid nodules (TN).Methods 84 TNs were included in the study.The SWE indices of Emax,Emin and Emean for the region-of-interest were calculated and analyzed.All TNs were divided into subgroups (< 10.0 mm group and > 10.0 mm group) according to the size and whether it has calcification (calcification group and non-calcification group).We compared the elasticity indices between subgroups and analyzed the diagnostic performance of SWE with different impact factors.Results There were 40 benign TNs and 44 malignant TNs.The Emean and Emax of malignant TNs were significant higher than those of benign TNs (P =0.000).Both the Emean and Emax of were significant higher in TNs with presence of calcification (P =0.036,P =0.031).The receiver operator characteristic (ROC) curve showed that the diagnostic sensitivity was 94.7% in the > 10.0 mm group with Emean > 19.6 kPa as the cut-off value,and 92.9% in non-calcification group with Emean >21.1 kPa as the cut-off value.Conclusions The elastic modulus of malignant TNs was significant higher than benign TNs.The presence of calcification may increase the stiffness of TNs.The diagnostic performance of SWE was better in TNs with those sizes > 10 mm and TNs with absence of calcification.
		                        		
		                        		
		                        		
		                        	
7.Assessment of the hardness of salivary gland lesions in patients with Sj?gren′s syndrome by real-time shear wave elastography
Juan CHEN ; Mingxing XIE ; Jing WANG ; Jun YOU ; Song LENG ; Yue SONG ; Feixiang XIANG ; Cheng YU
Chinese Journal of Ultrasonography 2018;27(3):220-225
		                        		
		                        			
		                        			Objective To investigate the clinical value of the real-time shear wave elastography(RT-SWE) in the assessment of salivary gland lesions by measuring the hardness of parotid gland and submaxillary gland in patients with Sj?gren′s syndrome (SS). Methods Forty patients with SS were chosen as SS group,and 35 age and gender matched healthy volunteers were chosen as control group.The patients were divided into mild SS group ( n =18) and severe SS group ( n =22) according to the decrease of uptake and secretion of salivary gland in Salivary gland scintigraphy.The Supersonic AixPlorer real-time quantitative diagnostic shear wave elastography was used to detect the parotid gland and submaxillary gland in 35 healthy volunteers and 40 patients.The RT-SWE elasticity indices of mean(Emean) was obtained and draw the SWE technology in the diagnosis of mild and severe SS patients with parotid and submandibular glands of the ROC curves. Results ① There was no significant difference in the Emean of left and right glands among the three groups (all P > 0.05). The Emean of parotid gland and submaxillary gland in patients with SS was higher than that in control group,especially in the severe SS group(all P <0.05). ②The cutoff value,sensitivity,specificity and the area under ROC for Emean with SWE diagnosing the parotid gland lesions of mild SS were 7.75 kPa,94.4%,97.1% and 0.998,and those in severe SS were 10.65 kPa, 90.9%,97.1% and 0.999,respectively.The cutoff value,sensitivity,specificity and the area under ROC for Emean with SWE diagnosing the the submaxillary glands lesions of mild SS were 8.15 kPa,100%,91.4%and 0.998,and those in severe SS were 10.40 kPa,95.5%,88.6% and 0.994,respectively.Conclusions RT-SWE can be successfully applied to assess parotid gland and submaxillary gland′s hardness in patients with SS,and provide a new method for the clinical evaluation of salivary gland diffuse lesions.
		                        		
		                        		
		                        		
		                        	
8.High-frequency ultrasound and contrast-enhanced ultrasonography findings for papillary thyroid microcarcinoma
Wen ZHANG ; Cheng YU ; Feixiang XIANG ; Jing WANG ; Mingxing XIE
Journal of Chinese Physician 2017;19(5):716-720
		                        		
		                        			
		                        			Objective To explore the features of high-frequency ultrasonography and contrast-enhanced ultrasonography (CEUS) of papillary thyroid microcarcinoma (PTMC).Methods The CEUS data and ultrasound data of 147 PTMCS which were reconfirmed by pathology were analyzed retrospectively,and the CEUS and ultrasonic characteristics of them were summarized.Results Among 147 nodules,144 (97.9%) nodules were hypoechoic,and 3 nodules were isoechoic.Vague edge was found in 136(92.5%) PTMCs,and 126(85.7%) PTMCs were irregular in shape.Totally 92(62.6%) PTMCs were A/T > 1,microcalcifications were found in 81 (55.1%) PTMCs.Besides,26(74.2%) PTMCs were found microcalcification in 35 PTMCs combined with Hashimoto's thyroiditis (HT),while 55 (49.1%) PTMCs were found microcalcification in 112 PTMCs combined with HT.There were significant differences between them (P < 0.05).The blood distribution of 129 (87.8%) nodules was type Ⅱ.The contrast-enhanced pattern of 147 (100.0%) PTMCs showed in-homogeneous enhancement in 144 (97.9%) nodules,hypoenhancement in 136(92.5%) nodules,and all the nodules without amicula.Conclusions The typical PTMCs are hypoechoic,irregular shapeand vague edge,usually were found as A/T > 1,microcalcification,and type Ⅱ blood distribution.With the method of contrast-enhanced ultrasonography,these nodules usually without amicula showed inhomogeneous and hypoenhancement.The incidence of microcalcification is more common when patients with Hashimoto's disease coexisting PTMC.
		                        		
		                        		
		                        		
		                        	
9.A correlation analysis of PICC tip position and weight gaining in very low birth weight infants
Feixiang LUO ; Shuohui CHEN ; Xiaoying CHENG ; Xiaoyan FAN ; Qin WANG ; Yajun YIN
Chinese Journal of Nursing 2017;52(8):949-953
		                        		
		                        			
		                        			Objective To investigate the correlation of PICC tip position and weight gaining in very low birth weight infants.Methods We performed a retrospective study using chest X-ray films of very low birth weight infants in NICU who had PICCs inserted in a tertiary hospital.We recorded the tip positions on plain radiographs and calculated the position change,and calculated weight gaining ratio.Spearman regression model was used to analyze the relationship between tip position migration and weight gaining ratio.Results A total of 57 cases of very low birth weight infants were included,containing 246 X-ray films.On the first day of taking X-ray,weight was 0.6-1.46 (1.06±0.25) kg,the median and interquartile spacing are 5(3,7)d.The last time of taking X-ray was(24.0±9.1) dafter PICC placement;weight gaining ratio was 11.8%~114.8%,the median and interquartile spacing are 41.5% (27.1%,65.3%).All PICCs tip position changed,75% of which migrated more than 2 vertebrae,50% of which migrated 3 vertebrae,and the median and interquartile spacing are 3 (1.8,3.5) vertebrae.The distances of tip migration were correlated with weight gaining ratio.With an approximate 2,3 and 4 vertebrae of PICC tip migration,the corresponding weight gaining ratio was about 40%,70% and 100%.The correlation coefficient between PICC tip position migration and weight gaining ratio was-0.7(P<0.01),but there was difference in different insertion sites.Conclusion PICC tip position is greatly influenced by weight gaining among very low birth weight infants.By considering the initial placement position,the crucial moment to assess catheter location is at 40% and 70% weight gaining ratio.After 100% weight gaining,PICCs should be removed or replaced.PICCs can easily be affected by bone growth and limb movement,require higher frequency of catheter localization.
		                        		
		                        		
		                        		
		                        	
10.On the interaction between cefonicid sodium and bovine serum albumin by spectrometry
Li LIU ; Yanfang LI ; Feixiang CHENG
Acta Universitatis Medicinalis Anhui 2017;52(1):52-56
		                        		
		                        			
		                        			Obiective To explore the interaction of cefonicid sodium(CS) with bovine serum albumin(BSA) by fluorescence and absorption spectroscopy. Methods The rate constant(Kq), quenching constant(Ksv), static fluo-rescence quenching association constant(KLB),binding site number(n) and binding constant(Kb) were calculated using Stern-Volmer, Lineweaver-Burk and double logarithm equations. Results CS was able to bind to BSA. The probable quenching mechanism of BSA by CS was mainly static quenching due to the formation of a CS-BSA com-plex. The results of thermodynamic parameters indicated that electrostatic force plays the main role in the binding process and the binding process was spontaneous. There was a single class of binding site for the BSA with CS. The primary binding site for CS was located at sub-domainⅡA of BSA and near by tyrosine residue. There was almost some negative cooperative effect. The results obtained from synchronous fluorescence showed that CS could change the microenvironment of Tyrand Trp residues of BSA. Conclusion The interaction between CS and BSA is dynam-ic. There is a single class of binding site for the BSA with CS. The obtained results provide references for its clini-cal application.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail