1.Factors Influencing and Adverse Reactions of Voriconazole Clearance in Patients with Hematological Diseases.
He-Gui HUANG ; Hai-Lin WANG ; Yi-Kai LIN ; Yan-Dong YI ; Min LIU ; Jun-Li DONG ; Jian-Min LIU ; Fan CHEN ; Ti-Ying DENG ; Song HU
Journal of Experimental Hematology 2023;31(2):562-567
OBJECTIVE:
To monitor the changes of voriconazole minimum concentration(Cmin) in patients with hematological diseases, and evaluate the factors influencing and adverse reactions of voriconazole clearance in patients with hematological diseases, so as to provide a theoretical basis for reasonable clinical use of voriconazole.
METHODS:
136 patients with hematological diseases who used voriconazole in Wuhan NO.1 Hospital from May 2018 to December 2019 were selected. The correlation between C-reactive protein, albumin, creatinine and voriconazole Cmin were analyzed, and the changes of voriconazole Cmin after glucocorticoid treatment was also detected. In addition, stratified analysis was used to explore the adverse events of voriconazole.
RESULTS:
Among 136 patients, 77 were male (56.62%) and 59 were female (43.38%). There were positive correlations between voriconazole Cmin and C-reactive protein and creatinine levels (r=0.277, r=0.208), while voriconazole Cmin was negatively correlated with albumin level (r=-2.673). Voriconazole Cmin in patients treated with glucocorticoid was decreased significantly (P<0.05). In addition, sratified analysis of voriconazole Cmin showed that compared with voriconazole Cmin 1.0-5.0 mg/L group, the incidence of adverse reactions of visual impairment in voriconazole Cmin> 5.0 mg/L group was increased (χ2=4.318, P=0.038).
CONCLUSION
The levels of C-reactive protein, albumin and creatinine are closely related to the voriconazole Cmin, which indicate that inflammation and hyponutrition may prevent the clearance of voriconazole in patients with hematological diseases. It is necessary to monitor the voriconazole Cmin of patients with hematological diseases, and adjust the dosage in time to reduce adverse reactions.
Humans
;
Male
;
Female
;
Voriconazole/therapeutic use*
;
Antifungal Agents/therapeutic use*
;
C-Reactive Protein
;
Creatinine
;
Glucocorticoids
;
Retrospective Studies
;
Drug Monitoring
;
Hematologic Diseases
2.A precision medication study of atomoxetine in children with attention deficit hyperactivity disorder: CYP2D6 genetic testing and therapeutic drug monitoring.
Di FU ; Hong-Li GUO ; Ya-Hui HU ; Feng CHEN
Chinese Journal of Contemporary Pediatrics 2023;25(1):98-103
Atomoxetine is the first non-stimulant drug for the treatment of children and adults with attention deficit hyperactivity disorder (ADHD), and its safety and efficacy show significant differences in the pediatric population. This article reviews the genetic factors influencing the pharmacokinetic differences of atomoxetine from the aspect of the gene polymorphisms of the major metabolizing enzyme CYP2D6 of atomoxetine, and then from the perspective of therapeutic drug monitoring, this article summarizes the reference ranges of the effective concentration of atomoxetine in children with ADHD proposed by several studies. In general, there is an association between the peak plasma concentration of atomoxetine and clinical efficacy, but with a lack of data from the Chinese pediatric population. Therefore, it is necessary to establish related clinical indicators for atomoxetine exposure, define the therapeutic exposure range of children with ADHD in China, and combine CYP2D6 genotyping to provide support for the precision medication of atomoxetine.
Adult
;
Child
;
Humans
;
Adrenergic Uptake Inhibitors/therapeutic use*
;
Atomoxetine Hydrochloride/therapeutic use*
;
Attention Deficit Disorder with Hyperactivity/genetics*
;
Cytochrome P-450 CYP2D6/therapeutic use*
;
Drug Monitoring
;
Genetic Testing
;
Propylamines/therapeutic use*
;
Treatment Outcome
3.Chinese consensus guidelines for therapeutic drug monitoring of polymyxin B, endorsed by the Infection and Chemotherapy Committee of the Shanghai Medical Association and the Therapeutic Drug Monitoring Committee of the Chinese Pharmacological Society.
Xiaofen LIU ; Chenrong HUANG ; Phillip J BERGEN ; Jian LI ; Jingjing ZHANG ; Yijian CHEN ; Yongchuan CHEN ; Beining GUO ; Fupin HU ; Jinfang HU ; Linlin HU ; Xin LI ; Hongqiang QIU ; Hua SHAO ; Tongwen SUN ; Yu WANG ; Ping XU ; Jing YANG ; Yong YANG ; Zhenwei YU ; Bikui ZHANG ; Huaijun ZHU ; Xiaocong ZUO ; Yi ZHANG ; Liyan MIAO ; Jing ZHANG
Journal of Zhejiang University. Science. B 2023;24(2):130-142
Polymyxin B, which is a last-line antibiotic for extensively drug-resistant Gram-negative bacterial infections, became available in China in Dec. 2017. As dose adjustments are based solely on clinical experience of risk toxicity, treatment failure, and emergence of resistance, there is an urgent clinical need to perform therapeutic drug monitoring (TDM) to optimize the use of polymyxin B. It is thus necessary to standardize operating procedures to ensure the accuracy of TDM and provide evidence for their rational use. We report a consensus on TDM guidelines for polymyxin B, as endorsed by the Infection and Chemotherapy Committee of the Shanghai Medical Association and the Therapeutic Drug Monitoring Committee of the Chinese Pharmacological Society. The consensus panel was composed of clinicians, pharmacists, and microbiologists from different provinces in China and Australia who made recommendations regarding target concentrations, sample collection, reporting, and explanation of TDM results. The guidelines provide the first-ever consensus on conducting TDM of polymyxin B, and are intended to guide optimal clinical use.
Humans
;
Anti-Bacterial Agents/therapeutic use*
;
China
;
Drug Monitoring/methods*
;
Polymyxin B
;
Practice Guidelines as Topic
4.Factors associated with glycemic variability in children with type 1 diabetes mellitus based on flash glucose monitoring system.
Liyin ZHANG ; Keyu GUO ; Yaling XU ; Jinlei BAI ; Yujin MA ; Liujun FU ; Jie LIU ; Keyan HU ; Xia LI ; Hongwei JIANG ; Lin YANG
Journal of Central South University(Medical Sciences) 2022;47(4):462-468
OBJECTIVES:
Patients with classical type 1 diabetes mellitus (T1DM) require lifelong dependence on exogenous insulin therapy due to pancreatic beta-cell destruction and absolute insulin deficiency. T1DM accounts for about 90% of children with diabetes in China, with a rapid increase in incidence and a younger-age trend. Epidemiological studies have shown that the overall glycated haemoglobin (HbA1c) and compliance rate are low in Chinese children with T1DM. Optimal glucose control is the key for diabetes treatment, and maintaining blood glucose within the target range can prevent or delay chronic vascular complications in patients with T1DM. Therefore, this study aims to investigate the glycemic control of children with T1DM from Hunan and Henan Province with flash glucose monitoring system (FGMS), and to explore factors associated with glycemic variability.
METHODS:
A total of 215 children with T1DM under 14 years old were enrolled continuously in 16 hospitals from August 2017 to August 2020. All subjects wore a FGMS device to collect glucose data. Correlation of HbA1c, duration of diabetes, or glucose scan rates with glycemic variability was analyzed. Glucose variability was compared according to the duration of diabetes, HbA1c, glucose scan rates and insulin schema.
RESULTS:
HbA1c and duration of diabetes were positively correlated with mean blood glucose, standard deviation of glucose, mean amplitude of glucose excursions (MAGE), and coefficient of variation (CV) of glucose (all P<0.01). The glucose scan rates during FGMS wearing was significantly positively correlated with time in range (TIR) (P=0.001) and negatively correlated with MAGE and mean duration of hypoglycemia (all P<0.01). Children with duration ≤1 year had lower time below range (TBR) and MAGE when compared with those with duration >1 year (all P<0.05). TIR and TBR in patients with HbA1c ≤7.5% were higher (TIR: 65% vs 45%, TBR: 5% vs 4%, P<0.05), MAGE was lower (7.0 mmol/L vs 9.4 mmol/L, P<0.001) than those in HbA1c >7.5% group. Compared to the multiple daily insulin injections group, TIR was higher (60% vs 52%, P=0.006), MAGE was lower (P=0.006) in the continuous subcutaneous insulin infusion group. HbA1c was lower in the high scan rates (≥14 times/d) group (7.4% vs 8.0%, P=0.046), TIR was significantly higher (58% vs 47%, P<0.001), and MAGE was lower (P<0.001) than those in the low scan rate (<14 times/d) group.
CONCLUSIONS
The overall glycemic control of T1DM patients under 14 years old in Hunan and Henan Province is under a high risk of hypoglycemia and great glycemic variability. Shorter duration of diabetes, targeted HbA1c, higher glucose scan rates, and CSII are associated with less glycemic variability.
Adolescent
;
Blood Glucose
;
Blood Glucose Self-Monitoring
;
Child
;
Diabetes Mellitus, Type 1/drug therapy*
;
Glucose
;
Glycated Hemoglobin A/analysis*
;
Humans
;
Hypoglycemia/prevention & control*
;
Hypoglycemic Agents/therapeutic use*
;
Insulin/therapeutic use*
5.Status of home blood pressure monitoring and influencing factors of regular home blood pressure monitoring among elderly uncontrolled hypertensive patients in Central and Western China.
Jia Ying LI ; Ting Xuan YANG ; Run Qing JI ; Wei LI ; Xue Ke BAI ; Jing LI ; Jia Min LIU
Chinese Journal of Cardiology 2022;50(10):1007-1013
Objective: To describe the prevalence of home blood pressure monitoring and analyze the factors influencing regular blood pressure monitoring among elderly uncontrolled hypertensive patients in Central and Western China. Methods: It was a cross-sectional study, which enrolled hypertensive patients aged over 60 years with office blood pressure ≥140/90 mmHg (1 mmHg=0.133 kPa) from September 2019 to July 2020 in 72 hospitals in Central and Western China. Patients completed the electronic questionnaires, and were divided into regular and irregular home blood pressure monitoring groups. The proportion of patients using different types of sphygmomanometers and the percentage of patients with regular home blood pressure monitoring (at least weekly) were explored. The generalized linear mixed model was used to define the influencing factors of regular home blood pressure monitoring. Results: A total of 3 857 patients were included in this study. Age was 67(64,71) years old and there were 2 163 males (56.1%). Overall, sphygmomanometer was available at home for 3 044(78.9%) patients, 2 168(56.2%) patients conducted regular home blood pressure monitoring. Among the patients with a sphygmomanometer at home, 2 370(77.9%) of the sphygmomanometers were upper arm electronic device. Older age, higher income, longer history of hypertension, multiple antihypertensive medications and awareness of diagnostic criteria of hypertension and hypertension complications were associated with a higher prevalence of regular home blood pressure monitoring (all P<0.05). Conclusions: Among the elderly hypertensive patients with uncontrolled blood pressure in Central and Western China, there is a relatively high prevalence of home sphygmomanometer ownership and regular monitoring. Age, family income, history of hypertension, number of antihypertensive drugs and knowledge of hypertension are the influencing factors of regular home blood pressure monitoring in this population.
Aged
;
Male
;
Humans
;
Middle Aged
;
Blood Pressure Monitoring, Ambulatory
;
Antihypertensive Agents/therapeutic use*
;
Cross-Sectional Studies
;
Hypertension/drug therapy*
;
Blood Pressure
;
China/epidemiology*
6.Effects of SGLT2i on 24-hour ambulatory blood pressure in patients with type 2 diabetes complicating hypertension: a meta-analysis.
Li TIAN ; Qiong Ying WANG ; Run Min SUN ; Miao Miao QI ; Ya Xin LI ; Xin GAO ; Li Qiong ZHANG ; Xue MA ; Hang SHI ; Jing YU ; Feng BAI
Chinese Journal of Cardiology 2021;49(10):1000-1011
Objective: To analyze the effects of different types of sodium-glucose cotransporter 2 inhibitors (SGLT2i) on 24-hour ambulatory blood pressure in patients with type 2 diabetes mellitus and hypertension. Method: In this meta-analysis, we searched for randomized controlled trials on the effect of SGLT2i on 24-hour ambulatory blood pressure in patients with type 2 diabetes and hypertension. Three databases, namely PubMed, Web of Science and Cochrane Library, were searched. The search was organized on the concept of 3 conceptual groups: the first group contained terms used to describe SGLT2i, the second group contained terms related to blood pressure, and the third group contained terms used to describe randomized controlled trials. The search time was from the establishment of the database to December 2020. The inclusion and exclusion criteria were formulated in accordance with the requirements of the Cochrane systematic review. According to whether the heterogeneity of the study was significant or not, a random effect model or a fixed effect model were used to conduct the analysis on the impact of different types of SGLT2i on 24-hour ambulatory blood pressure and day and night blood pressure in patients with type 2 diabetes and hypertension. Further subgroup analysis was performed to define potential factors, which might lead to clinical heterogeneity. Results: Seven clinical trials were finally included. The result of the meta-analysis showed that compared with placebo group, SGLT2i could reduce the 24-hour dynamic systolic blood pressure of patients with type 2 diabetes and hypertension by 4.36 mmHg (1 mmHg=0.133 kPa). Reduction was 4.59, 3.74, 5.06, and 3.64 mmHg by canagliflozin, dapagliflozin, empagliflozin, and ertugliflozin respectively; SGLT2i could reduce the 24-hour dynamic diastolic blood pressure of patients with type 2 diabetes and hypertension by 2.20 mmHg, and the reduction was 2.30, 1.22, 2.00, and 2.69 mmHg by canagliflozin, dapagliflozin, empagliflozin and ertugliflozin respectively. SGLT2i could reduce the daytime systolic blood pressure of patients with type 2 diabetes and hypertension by 5.25 mmHg, and reduction was 5.38, 4.87, 6.00, and 4.37 mmHg by canagliflozin, dapagliflozin, empagliflozin and ertugliflozin, respectively. Simultaneously, SGLT2i could reduce the diastolic blood pressure of patients with type 2 diabetes and hypertension by 2.62 mmHg, and the reduction was 2.56, 2.47, and 2.80 mmHg by canagliflozin, empagliflozin and ertugliflozin, respectively. SGLT2i could reduce the nighttime systolic blood pressure of patients with type 2 diabetes and hypertension by 3.62 mmHg, and the reduction was 2.09, 2.06, 3.92, and 2.45 mmHg by canagliflozin, dapagliflozin, empagliflozin and ertugliflozin, respectively. At the same time, SGLT2i could reduce the nighttime diastolic blood pressure of patients with type 2 diabetes and hypertension by 1.60 and 1.51 mmHg, the reduction was 1.53 and 2.58 mmHg by canagliflozin, empagliflozin and ertugliflozin, respectively. Conclusion: SGLT2i can reduce 24-hour ambulatory blood pressure in patients with type 2 diabetes and hypertension.
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Diabetes Mellitus, Type 2/drug therapy*
;
Humans
;
Hypertension/drug therapy*
;
Sodium-Glucose Transporter 2 Inhibitors/therapeutic use*
7.Antineoplastic Drug Handling: Higher Risk for Healthcare Workers in Tunisia than in France?
Kaouther ZRIBI ; Laetitia MINH MAI LE ; Asok RAJKUMAR ; Hail ABOUDAGGA ; Mounir FRIKHA ; Amandine DIETRICH ; Emna ZRIBI ; Fathi SAFTA ; Eric CAUDRON
Biomedical and Environmental Sciences 2020;33(10):803-806
8.Pharmacist-led anticoagulation monitoring can significantly improve the effectiveness and safety of warfarin for patients during hospitalization.
Jiawen HUANG ; Zhidong ZHANG ; Chengfeng HUANG ; Xiaohui LI ; Xiaoshen ZHANG ; Hua LU
Journal of Southern Medical University 2020;40(4):544-549
OBJECTIVE:
To investigate the role of pharmacist-led anticoagulation monitoring service for warfarin anticoagulation therapy in patients during hospitalization.
METHODS:
We retrospectively analyzed the data of 421 patients receiving warfarin anticoagulation therapy during hospitalization between April, 2016 and December, 2017. Of these patients, 316 received daily pharmacist-led anticoagulation monitoring service including checking the patients' International Normalized Ratio (INR) and other pertinent laboratory test results and reviewing medication changes and the patients' clinical status (monitoring group); the other 105 patients receiving warfarin anticoagulation therapy without pharmaceutical care served as the control group. The data including compliance rate of anticoagulant indicators, incidence and rate of prompt management of INR alert, thrombosis and bleeding events during hospitalization were analyzed among these patients.
RESULTS:
Compared with the control patients, the patients in the monitoring group showed a significantly higher percentage time within target INR range [(73.20±9.46)% (46.32±17.11)%, < 0.001] and a higher qualified rate of INR before discharge (98.42% 60.95%, < 0.001) as well as a higher proper INR-monitoring frequency (97.15% 66.67%, < 0.001). The patients in the monitoring group showed a significantly lower incidence of INR alert than the control patients (8.23% 20.00%, < 0.001) with also a much higher rate of prompt management (96.15% 33.33%). The two groups had similar incidences of clinical events except that the control group reported a higher incidence of minor bleeding episodes (9.52% 2.53%, =0.005).
CONCLUSIONS
Pharmacist-led anticoagulation monitoring service can significantly improve the effectiveness and safety of warfarin anticoagulation therapy for patients during hospitalization.
Anticoagulants
;
Drug Monitoring
;
Hospitalization
;
Humans
;
Pharmacists
;
Retrospective Studies
;
Warfarin
9.Difference Analysis of System Accuracy Criteria between Self-Monitoring Blood Glucose Test System and Point-of-Care Blood Glucose Monitoring Systems.
Chinese Journal of Medical Instrumentation 2020;44(4):338-342
According to users and places, blood glucose monitoring systems(BGMSs) can be divided into self-monitoring blood glucose test systems(SMBGs) and Point-of-Care Blood Glucose monitoring systems(POC-BGMSs). The Food and Drug Administration(FDA) believes that standards for SMBGs and POC-BGMSs should be different because of different operators, different use environments, different intendance uses and different applicable populations. Now the international standards for evaluating BGMSs include ISO 15197:2013 issued by International Organization for Standardization(ISO), two guidelines on blood glucose monitoring systems issued by FDA, and POCT12-A3 guidelines issued by the American Association for Clinical and Laboratory Standardization(CLSI), ISO standard and FDA guideline-OTC are applicable in SMBGs, CLSI guideline and FDA guideline-POCTI2-A3 are suitable for POC-BGMSs. By analyzing the accuracy evaluation processes of BGMSs based on four standard documents, it is found that the accuracy evaluation of medical BGMSs is more stringent. It is proposed that SMBGs and POC-BGMSs should be supervised separately.
Blood Glucose
;
Blood Glucose Self-Monitoring
;
Point-of-Care Systems
;
Reference Standards
;
Reproducibility of Results
;
United States
;
United States Food and Drug Administration
10.Establishment of a rapid identification of adverse drug reaction program in R language implementation based on monitoring data.
Dongsheng HONG ; Jian NI ; Wenya SHAN ; Lu LI ; Xi HU ; Hongyu YANG ; Qingwei ZHAO ; Xingguo ZHANG
Journal of Zhejiang University. Medical sciences 2020;49(2):253-259
OBJECTIVE:
To establish a clinically applicable model of rapid identification of adverse drug reaction program (RiADP) for risk management and decision-making of clinical drug use.
METHODS:
Based on the theory of disproportion analysis, frequency method and Bayes method, a clinically applicable RiADP model in R language background was established, and the parameters of the model were interpreted by MedDRA coding. Based on the actual monitoring data of FDA, the model was validated by the assessing hepatotoxicity of lopinavir/ritonavir (LPV/r).
RESULTS:
The established RiADP model included four parameters: standard value of adverse drug reaction signal information, empirical Bayesian geometric mean value, ratio of reporting ratio and number of adverse drug reaction cases. Through the application of R language parameter package "phViD", the model parameters could be output quickly. After being encoded by MedDRA, it was converted into clinical terms to form a clinical interpretation report of adverse drug reactions. In addition, the evaluation results of LPV/r hepatotoxicity by the model were matched with the results reported in latest literature, which also proved the reliability of the model results.
CONCLUSIONS
In this study, a rapid identification method of adverse reactions based on post marketing drug monitoring data was established in R language environment, which is capable of sending rapid warning of adverse reactions of target drugs in public health emergencies, and providing intuitive evidence for risk management and decision-making of clinical drugs.
Databases, Pharmaceutical
;
Decision Making, Computer-Assisted
;
Drug Monitoring
;
Drug-Related Side Effects and Adverse Reactions
;
HIV Protease Inhibitors
;
adverse effects
;
pharmacology
;
Humans
;
Liver
;
drug effects
;
Lopinavir
;
adverse effects
;
toxicity
;
Models, Statistical
;
Reproducibility of Results
;
Software
;
standards

Result Analysis
Print
Save
E-mail