1.The Evidence-based Periodontal Risk Assessment (PRA) Tool for Nonsurgical Periodontal Therapy in a Comprehensive Periodontal Management by Risk Assessment (PEMBRA)
Mahyunah Masud ; Izza Ilyani Mohd Ishak ; Najihah Kamarazaman ; Izyan Hazwani Baharuddin
Archives of Orofacial Sciences 2022;17(SUPP 1):85-96
		                        		
		                        			ABSTRACT
		                        			In the management of periodontitis patients, periodontal risk assessment (PRA) tool is currently being 
applied during periodontal review (PR). However, an assessment of risk profiles during examination and 
diagnosis (E&D) may and would effectively assess and diagnose patients’ periodontal conditions, provide 
personalised treatment planning, and render an enhanced patient care through periodontal management 
by risk assessment (PEMBRA). From a retrospective study on selected records of 81 patients treated 
for chronic periodontitis, the PRA profiles of the patients were evaluated during E&D and two to three 
months after completion of nonsurgical periodontal therapy (NSPT) during PR. The results were 
analysed using SPSS version 24 for descriptive statistics. On E&D, the patients presented with 25.9% 
localised and 74.1% generalised chronic periodontitis. Of these, 2.5% of low-risk patients on E&D 
increased to 21% during PR signifying an improvement after the treatment. However, the medium-risk 
patients have a slight increase from 32% to 35%, and patients with a high risk of 62% were reduced to 
43%. The improvement of the risk profiles for both low and high-risk groups was mostly contributed 
by the reduction in the plaque score, percentages of bleeding on probing (BOP), and probing pocket 
depth (PPD) ≥ 5 mm. This evidence-based evaluation of PRA tool during E&D and PR is important for PEMBRA as it encouraged the clinicians to adopt periodontal management through basic periodontal 
examination, detailed periodontal charting, radiographic interpretation, tooth per tooth prognosis, 
diagnosis, and targeted NSPT.
		                        		
		                        		
		                        		
		                        			Risk Assessment
		                        			;
		                        		
		                        			 Periodontal Diseases -- diagnosis
		                        			;
		                        		
		                        			 Dental Instruments
		                        			
		                        		
		                        	
2.Diagnostic consistency for observing endodontic files in digital radiographs displayed on different electronic devices.
Chinese Journal of Stomatology 2022;57(4):384-389
		                        		
		                        			
		                        			Objectives: To evaluate the diagnostic consistency of working lengths by observing endodontic files in root canals and periapical subtle structures in digital intraoral radiographs presented in two smartphones, a tablet and a laptop computer. Methods: A dried human skull embedded in an acrylic compound was used for exposing radiographs of the upper and lower second premolars and first molars with two endodontic files (Kerr files size 10 and 15) positioned to the full length of the roots or 1.5 mm short of apexes. A total of 100 radiographs were taken for each of the file sizes. Five observers were asked to assess all the 200 digital radiographs according to a 5-category scale in smartphone A (HUAWEI P9 Plus), smartphjone B (Apple iPhone 7), tablet (Apple iPad 2018) and laptop computer (Lenovo Thinkpad E480), respectively. The gold standard for receiver operating characteristic curve (ROC) analysis was determined with the endodontic Kerr file size 20. A total of 150 roots with files were radiographed, 75 of which with files reaching the radiographic apexes of the respective roots and 75 of which with files 1.5 mm short of the radiographic apexes for each endodontic file size. Results from ROC analysis was analyzed with one-way ANOVA and independent sample t test. Results: For the Kerr file size 10, the area under the ROC curve for laptop, tablet and two smartphones were 0.891±0.037, 0.869±0.037, 0.870±0.017 and 0.849±0.037, while for the Kerr file size 15 the ROC values were 0.957±0.02, 0.961±0.02, 0.961±0.01 and 0.961±0.02, respectively. There were no significant differences for diagnostic accuracy for observing endodontic file positions among digital radiographs presented in the two smartphones, one tablet and one laptop devices (endodontic file size 10: F=1.39, P=0.281; endodontic file size 15: F=0.05, P=0.985). A significant difference was found in the diagnostic accuracy of endodontic file positions between size 10 and 15 files in different display devices (t=-10.65, P<0.001). Conclusions: There was a high diagnostic consistency in the determination of working length and periapical subtle structures of roots by observing digital radiographs displayed on smartphones, tablet and laptop computer.
		                        		
		                        		
		                        		
		                        			Dental Instruments
		                        			;
		                        		
		                        			Dental Pulp Cavity/diagnostic imaging*
		                        			;
		                        		
		                        			Electronics
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Molar
		                        			;
		                        		
		                        			Observer Variation
		                        			;
		                        		
		                        			Root Canal Preparation
		                        			
		                        		
		                        	
3.Evolution and development: engine-driven endodontic rotary nickel-titanium instruments.
International Journal of Oral Science 2022;14(1):12-12
		                        		
		                        			
		                        			Various engine-driven NiTi endodontic files have been indispensable and efficient tools in cleaning and shaping of root canals for practitioners. In this review, we introduce the relative terms and conceptions of NiTi file, including crystal phase composition, the design of the cutting part, types of separation. This review also analysis the main improvement and evolution of different generations of engine-driven nickel-titanium instruments in the past 20 years in the geometric design, manufacturing surface treatment such as electropolishing, thermal treatment, metallurgy. And the variety of motion modes of NiTi files to improve resistance to torsional failure were also discussed. Continuous advancements by the designers, provide better balance between shaping efficiency and resistance to of NiTi systems. In clinical practice an appropriate system should be selected based on the anatomy of the root canal, instrument characteristics, and operators' experience.
		                        		
		                        		
		                        		
		                        			Dental Alloys/chemistry*
		                        			;
		                        		
		                        			Dental Instruments
		                        			;
		                        		
		                        			Equipment Design
		                        			;
		                        		
		                        			Nickel/chemistry*
		                        			;
		                        		
		                        			Root Canal Preparation
		                        			;
		                        		
		                        			Titanium/chemistry*
		                        			
		                        		
		                        	
4.The survey on the infection control of noncritical instruments used in dental treatment
Journal of Dental Rehabilitation and Applied Science 2019;35(1):27-36
		                        		
		                        			
		                        			PURPOSE: The aims of this study were to evaluate the dentist's awareness and the actual status of infection control of noncritical dental instruments. MATERIALS AND METHODS: 40 dental clinics in Daejeon, South Chungcheong, North Chungcheong and North Jeolla provinces were surveyed. The questionnaire was delivered to the dentists belonging to those clinics, and the awareness and the practice of infection control were examined. The microbial contamination on the surface of five noncritical instruments (impression gun, light curing unit, 3-way syringe, shade guide, and dental floss dispenser) used by them was measured with an ATP luminometer. Correlation analysis between the awareness and the actual state of infection control was conducted. RESULTS: Awareness and frequency of infection control was highest in the 3-way syringe. Surface disinfection using disinfectant was most frequent in all instruments. 3-way syringes and shade guides were less contaminated than impression guns, light curing units, and dental floss dispensers. CONCLUSION: 3-way syringes had a significant correlation between user awareness of infection control and surface contamination, and the higher awareness, the lower the contamination measurement was shown.
		                        		
		                        		
		                        		
		                        			Adenosine Triphosphate
		                        			;
		                        		
		                        			Dental Clinics
		                        			;
		                        		
		                        			Dental Devices, Home Care
		                        			;
		                        		
		                        			Dental Instruments
		                        			;
		                        		
		                        			Dentists
		                        			;
		                        		
		                        			Disinfection
		                        			;
		                        		
		                        			Firearms
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Infection Control
		                        			;
		                        		
		                        			Syringes
		                        			
		                        		
		                        	
5.Foreign body aspiration during dental treatment under general anesthesia: A case report
Journal of Dental Anesthesia and Pain Medicine 2019;19(2):119-123
		                        		
		                        			
		                        			Foreign body aspiration in dental clinics is the most common cause of respiratory emergencies. There are no reports on foreign body aspiration during dental treatment under stable general anesthesia because the patient neither has voluntary movements nor reflex actions. This is a case report on the fall of a prosthesis in the larynx, which occurs rarely under general anesthesia. During the try-in procedure, the prosthesis slid from the surgeon's hand and entered the retromylohyoid space, and while searching for it, it passed down the larynx to the endotracheal tube balloon, leading to a dangerous situation. The prosthesis was promptly removed using video-assisted laryngoscope and forceps, and the patient was discharged without any complications.
		                        		
		                        		
		                        		
		                        			Anesthesia, General
		                        			;
		                        		
		                        			Dental Clinics
		                        			;
		                        		
		                        			Emergencies
		                        			;
		                        		
		                        			Foreign Bodies
		                        			;
		                        		
		                        			Hand
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Laryngoscopes
		                        			;
		                        		
		                        			Larynx
		                        			;
		                        		
		                        			Prostheses and Implants
		                        			;
		                        		
		                        			Reflex
		                        			;
		                        		
		                        			Surgical Instruments
		                        			
		                        		
		                        	
6.The push-out bond strength of BIOfactor mineral trioxide aggregate, a novel root repair material
Makbule Bilge AKBULUT ; Durmus Alperen BOZKURT ; Arslan TERLEMEZ ; Melek AKMAN
Restorative Dentistry & Endodontics 2019;44(1):e5-
		                        		
		                        			
		                        			OBJECTIVES: The aim of this in vitro study was to evaluate the push-out bond strength of a novel calcium silicate-based root repair material-BIOfactor MTA to root canal dentin in comparison with white MTA-Angelus (Angelus) and Biodentine (Septodont). MATERIALS AND METHODS: The coronal parts of 12 central incisors were removed and the roots were embedded in acrylic resin blocks. Midroot dentin of each sample was horizontally sectioned into 1.1 mm slices and 3 slices were obtained from each root. Three canal-like standardized holes having 1 mm in diameter were created parallel to the root canal on each dentin slice with a diamond bur. The holes were filled with MTA-Angelus, Biodentine, or BIOfactor MTA. Wet gauze was placed over the specimens and samples were stored in an incubator at 37°C for 7 days to allow complete setting. Then samples were subjected to the push-out test method using a universal test machine with the loading speed of 1 mm/min. Data was statistically analyzed using Friedman test and post hoc Wilcoxon signed rank test with Bonferroni correction. RESULTS: There were no significant differences among the push-out bond strength values of MTA-Angelus, Biodentine, and BIOfactor MTA (p > 0.017). Most of the specimens exhibited cohesive failure in all groups, with the highest rate found in Biodentine group. CONCLUSIONS: Based on the results of this study, MTA-Angelus, Biodentine, and BIOfactor MTA showed similar resistances to the push-out testing.
		                        		
		                        		
		                        		
		                        			Calcium
		                        			;
		                        		
		                        			Dental Instruments
		                        			;
		                        		
		                        			Dental Pulp Cavity
		                        			;
		                        		
		                        			Dentin
		                        			;
		                        		
		                        			In Vitro Techniques
		                        			;
		                        		
		                        			Incisor
		                        			;
		                        		
		                        			Incubators
		                        			;
		                        		
		                        			Methods
		                        			;
		                        		
		                        			Miners
		                        			;
		                        		
		                        			Pemetrexed
		                        			
		                        		
		                        	
7.Effect of cooling water temperature on the temperature changes in pulp chamber and at handpiece head during high-speed tooth preparation
Restorative Dentistry & Endodontics 2019;44(1):e3-
		                        		
		                        			
		                        			OBJECTIVES: It was the aim of this study to evaluate the effect of cooling water temperature on the temperature changes in the pulp chamber and at the handpiece head during high-speed tooth preparation using an electric handpiece. MATERIALS AND METHODS: Twenty-eight intact human molars received a standardized occlusal preparation for 60 seconds using a diamond bur in an electric handpiece, and one of four treatments were applied that varied in the temperature of cooling water applied (control, with no cooling water, 10°C, 23°C, and 35°C). The temperature changes in the pulp chamber and at the handpiece head were recorded using K-type thermocouples connected to a digital thermometer. RESULTS: The average temperature changes within the pulp chamber and at the handpiece head during preparation increased substantially when no cooling water was applied (6.8°C and 11.0°C, respectively), but decreased significantly when cooling water was added. The most substantial drop in temperature occurred with 10°C water (−16.3°C and −10.2ºC), but reductions were also seen at 23°C (−8.6°C and −4.9°C). With 35°C cooling water, temperatures increased slightly, but still remained lower than the no cooling water group (1.6°C and 6.7ºC). CONCLUSIONS: The temperature changes in the pulp chamber and at the handpiece head were above harmful thresholds when tooth preparation was performed without cooling water. However, cooling water of all temperatures prevented harmful critical temperature changes even though water at 35°C raised temperatures slightly above baseline.
		                        		
		                        		
		                        		
		                        			Burns
		                        			;
		                        		
		                        			Dental Instruments
		                        			;
		                        		
		                        			Dental Pulp Cavity
		                        			;
		                        		
		                        			Head
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Molar
		                        			;
		                        		
		                        			Thermometers
		                        			;
		                        		
		                        			Tooth Preparation
		                        			;
		                        		
		                        			Tooth
		                        			;
		                        		
		                        			Water
		                        			
		                        		
		                        	
8.Effects of different surface finishing protocols for zirconia on surface roughness and bacterial biofilm formation
Du Hyeong LEE ; Hang Nga MAI ; Phyu Pwint THANT ; Su Hyung HONG ; Jaewon KIM ; Seung Mi JEONG ; Keun Woo LEE
The Journal of Advanced Prosthodontics 2019;11(1):41-47
		                        		
		                        			
		                        			PURPOSE: Surface finishing of a zirconia restoration is essential after clinical adjustment. Herein, we investigated the effects of a surface finishing protocol for monolithic zirconia on final roughness and bacterial adherence. MATERIALS AND METHODS: Forty-eight disk-shaped monolithic zirconia specimens were fabricated and divided into four groups (n = 12) based on initial surface treatment, finishing, and polishing protocols: diamond bur+polishing bur (DP group), diamond bur+stone grinding bur+polishing bur (DSP group), no diamond bur+polishing bur (NP group), and no diamond bur+stone grinding bur+polishing bur (NSP group). Initial and final surface roughness was measured with a profilometer, and shown using scanning electron microscope. Bacterial adhesion was evaluated by quantifying Streptococcus mutans in the biofilm. Kruskal-Wallis and Mann-Whitney U tests were used to compare results among groups, and two-way analysis of variance was used to evaluate the effects of grinding burs on final roughness (α=.05). RESULTS: The DP group had the highest final Ra value, followed by the DSP, NP, and NSP groups. Use of the stone grinding bur as a coarse-finishing step significantly decreased final Ra values when a diamond bur was used (P < .001). Omission of the stone grinding bur increased biofilm formation on specimen surfaces. Combining a stone grinding bur with silicone polishing burs produced the smallest final biofilm values, regardless of the use of a diamond bur in initial surface treatment. CONCLUSION: Coarse finishing of monolithic zirconia with a stone grinding bur significantly decreased final Ra values and bacterial biofilm formation when surfaces had been roughened by a diamond bur.
		                        		
		                        		
		                        		
		                        			Bacterial Adhesion
		                        			;
		                        		
		                        			Biofilms
		                        			;
		                        		
		                        			Dental Instruments
		                        			;
		                        		
		                        			Dental Polishing
		                        			;
		                        		
		                        			Diamond
		                        			;
		                        		
		                        			Silicon
		                        			;
		                        		
		                        			Silicones
		                        			;
		                        		
		                        			Streptococcus mutans
		                        			
		                        		
		                        	
9.The effects of surface grinding and polishing on the phase transformation and flexural strength of zirconia
Ji Young LEE ; Geun Won JANG ; In Im PARK ; Yu Ri HEO ; Mee Kyoung SON
The Journal of Advanced Prosthodontics 2019;11(1):1-6
		                        		
		                        			
		                        			PURPOSE: The purpose of this in vitro study was to evaluate the effect of surface grinding and polishing procedures using high speed zirconia diamond burs with different grit sizes on the phase transformation and flexural strength of zirconia.
		                        		
		                        		
		                        		
		                        			Dental Instruments
		                        			;
		                        		
		                        			Diamond
		                        			;
		                        		
		                        			In Vitro Techniques
		                        			;
		                        		
		                        			Occlusal Adjustment
		                        			
		                        		
		                        	
10.Surface microstructure and cyclic fatigue resistance of electro discharged machining nickel-titanium endodontic instrument.
Fang Fang WANG ; Yin Jie YANG ; Xiao Mei HOU
Journal of Peking University(Health Sciences) 2018;50(5):876-881
		                        		
		                        			OBJECTIVE:
		                        			To compare the surface microstructures and cyclic fatigue resistance of HyFlex EDM with HyFlex CM and HyFlex NT.
		                        		
		                        			METHODS:
		                        			Twelve 25 mm-long 25#/- HyFlex EDM and twelve 25 mm-long 25#/0.06 taper HyFlex CM or HyFlex NT were selected. The surface microstructure of the 2 instruments which were randomly selected from each group was observed by using scanning electron microscope (SEM). The remaining 10 instruments from each group were submitted to the cyclic fatigue test by using a simulated stainless steel root canal with 60° angle of curvature and curvature radius of 3.5 mm. The time till fracture was recorded, the number of cyclic fatigue (NCF) was calculated, the length of fracture fragment was evaluated, and the topographic features were analyzed by using SEM. The data were analyzed by using one-way analysis via SPSS 23.0 software. The statistical significance level was set at 0.05.
		                        		
		                        			RESULTS:
		                        			SEM observation of the surface and microstructural characterization revealed peculiar melting appearance and evenly distributed micropores on the surface of HyFlex EDM while observations of the surface of both HyFlex CM and HyFlex NT demonstrated machining grooves and irregularities. The NCF of HyFlex EDM was 838±223, which was significantly higher than not only that of HyFlex CM (582±99), but also that of HyFlex NT (81±20) (P<0.05), and the difference between the latter two groups was significant, as well (P<0.05). The length of fractured fragments of HyFlex EDM was (7.27±0.28) mm, which was significantly longer than the HyFlex CM and HyFlex NT, with values of (6.72±0.26) mm and (6.62±0.37) mm, respectively (P<0.05). Topographic features demonstrated typical cyclic fatigue for all the three groups while the region of crack origins was more for HyFlex EDM and HyFlex CM than that of HyFlex NT. As far as the dimple area was concerned, that of HyFlex EDM was deeper and larger than that of HyFlex CM and HyFlex NT.
		                        		
		                        			CONCLUSION
		                        			Within the limitations of this study, electro-discharge machining leads to peculiar melting appearance with micropores instead of machining grooves and irregularities on the surface of HyFlex EDM, which may be the reason why HyFlex EDM exhibits significantly better cyclicfatigue resistance than HyFlex CM and HyFlex NT.
		                        		
		                        		
		                        		
		                        			Dental Alloys
		                        			;
		                        		
		                        			Dental Instruments
		                        			;
		                        		
		                        			Equipment Failure
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Materials Testing
		                        			;
		                        		
		                        			Nickel
		                        			;
		                        		
		                        			Root Canal Preparation
		                        			;
		                        		
		                        			Titanium
		                        			
		                        		
		                        	
            

Result Analysis