1.Assessment of perioperative pulmonary fluid volume using remote dielectric sensing (ReDSTM) non-invasive lung fluid measurement technology in transcatheter tricuspid valve-in-valve implantation: The first case report
Yuliang LONG ; Yuan ZHANG ; Xiaochun ZHANG ; Peng WANG ; Xiaotong CUI ; Wenzhi PAN ; Daxin ZHOU ; Junbo GE
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(04):571-574
One of its primary surgical treatments of tricuspid regurgitation is tricuspid valve biological valve replacement. Catheter tricuspid valve-in-valve implantation is a novel interventional alternative for biological valve failure. The non-invasive lung fluid measuring device remote dielectric sensing (ReDSTM) has been increasingly incorporated into clinical practice as a means of monitoring chronic heart failure in recent years. This report describes the process and outcomes of the first instance of perioperative lung fluid volume evaluation following transcatheter tricuspid valve implantation utilizing ReDSTM technology. The patient has a short-term, substantial increase in postoperative lung fluid volume as compared to baseline.
2.Annual report on transcatheter left atrial appendage closure in 2024
Yuan BAI ; Xiaochun ZHANG ; Jie ZENG ; Yongjian WU ; Daxin ZHOU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(06):746-751
After two decades of development, transcatheter left atrial appendage closure has emerged as a safe and effective intervention for stroke prevention in patients with atrial fibrillation. In 2024, significant advancements were made in the field of left atrial appendage closure in terms of evidence-based medicine, device research and development, and guideline consensus. The annual report on transcatheter left atrial appendage closure systematically reviews global academic progress in 2024, encompassing newly published clinical evidence, recently developed occlusion devices, and updated international guidelines/consensus statements. In the future, the development direction of transcatheter left atrial appendage closure mainly includes expanding surgical indications, optimizing imaging assistance technology, improving closure device design, and exploring individualized strategies for postoperative antithrombotic therapy.
3.2024 annual report of interventional treatment for congenital heart disease
Changdong ZHANG ; Yucheng ZHONG ; Geng LI ; Jun TIAN ; Gejun ZHANG ; Nianguo DONG ; Yuan FENG ; Daxin ZHOU ; Yongjian WU ; Lianglong CHEN ; Xiaoke SHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(07):909-918
In recent years, with the continuous development and increasing maturity of interventional techniques, interventional treatment for congenital heart disease (CHD) has been progressively disseminated to county- and city-level hospitals in China. Concurrently, the standardized management of adult CHD (particularly patent foramen ovale) and the lifelong management of complex CHD are gaining increasing clinical attention, while the emergence of new techniques and products continuously advances the discipline. This article aims to review the new progress made in the field of interventional treatment for congenital heart disease in China during 2024. It specifically reviews and analyzes the following key aspects: (1) annual statistics on interventional closure procedures for CHD; (2) recent insights into patent foramen ovale closure; (3) advances in transcatheter pulmonary valve replacement; (4) interventional treatment and lifelong management strategies for complex CHD; (5) new interventional techniques for acquired heart disease; and (6) the application of artificial intelligence in CHD management. Through the synthesis and discussion of these topics, this article seeks to provide a detailed analysis of the current landscape of interventional treatment for CHD in China and project its future development trends.
4.Mitral transcatheter edge-to-edge repair: A state of art and strategic principles
Wenzhi PAN ; Yuliang LONG ; Daxin ZHOU ; Junbo GE
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):181-185
Transcatheter edge-to-edge repair (TEER) for mitral regurgitation (MR) is known as M-TEER. Its strengths include: precise targets and fewer implants; simple and clear principles for catheterization; originating from dependable medical concepts and broad applicability. Furthermore, TEER offers advantages in real-time hemodynamic and effectiveness measurement throughout the procedure over surgical edge-to-edge repair (SEER). When it comes to patients with degenerative mitral regurgitation , M-TEER should aim to deliver more optimum procedural outcomes. In functional mitral regurgitation, a modest transvalvular gradients or moderate residual shunt can be tolerated with M-TEER, which reduces the risk of problems and has no bearing on the patient's prognosis.
5.Transcatheter aortic valve replacement (TAVR) annual report 2023
Wenzhi PAN ; Yanxing FANG ; Jie LI ; Fei LI ; Daxin ZHOU ; Junbo GE
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(04):498-503
Transcatheter aortic valve replacement (TAVR) has seen a surge in clinical research, basic research, and innovative device development both domestically and internationally in the previous 2023. This article aims to review the progress of TAVR in the past year from the perspectives of international, and domestic research development of application. It highlights new clinical and basic research findings both domestically and internationally, the emergence of new devices and technologies, and the development and use of TAVR in China. Finally, it provides an outlook on the trajectory of TAVR development in 2024.
6.Impact of the LAmbre device on left atrial appendage adjacent structures and left atrium
Zhengdan GE ; Dehong KONG ; Zhenyi GE ; Chunqiang HU ; Xiaochun ZHANG ; Haiyan CHEN ; Daxin ZHOU ; Xianhong SHU ; Cuizhen PAN
Chinese Journal of Ultrasonography 2024;33(2):142-150
Objective:To explore the effects of the LAmbre device and mitral annulus(MA), as well as left atrium(LA) in patients with non-valvular atrial fibrillation(NVAF) after left atrial appendage closure (LAAC) using real-time-three-dimensional transesophageal echocardiography (3D TEE).Methods:Fity-six consecutive patients who underwent LAAC with the LAmbre device in Zhongshan Hospital of Fudan University from June 2019 to March 2023 were retrospectively enrolled, with no or less than moderate mitral regurgitation (MR). All patients underwent pre-operative and follow-up two-and three-dimensional transesophageal echocardiography (2D TEE, 3D TEE) at 60 days after the operation. The quantitative parameters of MA and LA were obtained by offline analysis using QLab 13.0 (Philips Healthcare, Andover, MA). Importantly, mitral annular measurements were made at seven time points throughout the cardiac cycle: early diastole, mid-diastole, late diastole, mitral valve closure, early systole, mid-systole, and late systole, which facilitates constructing the dynamic model of MA to assess the annular morphology and dynamics.Results:The values of AP diameter (APD), AL-PM diameter (ALPMD), 3D annulus circumference (3DAC), 3D annulus area (3DAA) decreased significantly compared with pre-operative values at all time points of the cardiac cycle (all P<0.05), while non-planar angle (NPA) and AH/CD were not apparently changed (all P>0.05 ). Throughout the cardiac cycle, MA showed regular changes, gradually increased in systole with the saddle shape deepened, and gradually decreased in diastole with the saddle shape shallowed.During systole, there was an increase in the rate of change of AP in MA [pre-operative (3.01±2.64)%, post-operative (3.81±3.51)%, P=0.037] after LAAC, with no significant difference in the rate of change of ALPM, 3DAC, and 3DAA.Meanwhile, we observed an evident reduction in LA minimal volume (LAVmin) [pre-operative (78.36±25.16)ml, post-operative (70.73±22.78)ml, P=0.004] and an obvious increase in LA ejection function [pre-operative (22.88±10.09)%, post-operative (31.41±12.28)%, P<0.05] during follow-up. Conclusions:3D TEE can accurately assess the impact of LAAC on the MA and LA. The LAmbre device can affect the morphology of MA, as well as the structure and function of LA, while the change of the dynamics of MA is not so prominent.
7.Multicenter expert recommendations on interventional valve-in-valve technology for mitral bioprosthetic valve destruction in China
Haibo ZHANG ; Xiangbin PAN ; Yingqiang GUO ; Lai WEI ; Jian YANG ; Daxin ZHOU ; Yongjian WU ; Xu MENG ; Liming LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(08):1090-1095
Mitral valve replacement is one of the most common heart valve surgeries in China. In recent years, with the increase in degenerative valve diseases, older patients, and the progress of anti-calcification technology of biological valves, the proportion of mitral valve biological valve replacement has been increasing year by year. After the damage of traditional mitral valve biological valves, re-operation of valve replacement with thoracotomy is required. However, the adhesion between the heart and sternum, as well as the damage caused by cardiopulmonary bypass and cardiac arrest, can cause significant trauma to elderly patients and those with multiple organ dysfunction, leading to increased mortality and complication rates. In recent years, interventional valve surgery, especially transcatheter valve-in-valve surgery, has developed rapidly. This procedure can correct the damaged mitral valve function without stopping the heart, but there are still many differences between its technical process and conventional aortic valve replacement surgery. Therefore, organizing and writing multicenter expert recommendations on the technical process of transcatheter valve-in-valve surgery for damaged mitral valve biological valves is of great significance for the training and promotion of this technology.
8.Protocol for the Traditional Chinese Medicine Diagnosis and Treatment Guidelines for Children with Upper Airway cough Syndrome
Lingyun ZHANG ; Xiyou WANG ; Daxin LIU ; Qiang HE ; Xuefeng WANG ; Xun LI ; Yutong FEI ; Yi XIAO ; Xiaoxue LAN ; Yuanwen LIANG ; Xiaoxuan LIN ; Rong ZHOU ; Sirui GU ; Ying ZHANG ; Yue WANG ; Xingzhu YE ; Wenke LIU ; Hong CHEN ; Changhe YU
International Journal of Traditional Chinese Medicine 2024;46(8):961-966
In order to standardize the clinical diagnosis and treatment of upper airway cough syndrome (UACS) for children in China, Dongzhimen Hospital of Beijing University of Chinese Medicine and Affiliated Hospital of Liaoning University of Traditional Chinese Medicine initiated the development of this Traditional Chinese Medicine Diagnosis and Treatment Guidelines for Children with Upper Airway cough Syndrome based on evidence-based medical evidence. This guideline will process registration, write a plan, and develop relevant processes and writing norms, develop and publish official documents. This plan mainly introduces the scope of the guidelines, the purpose and significance, the composition of the guidelines working group, the management of conflicts of interest, the collection, selection and determination of clinical problems, the retrieval, screening and rating of evidence, and the consensus of recommendations. Registration information: This study has been registered in the international practice guidelines registry platform with the registration code of PREPARE-2023CN087.
9.Research progress on predictors of conduction block and pacemaker implantation after transcatheter aortic valve replacement
Jianing FAN ; Dawei LIN ; Daxin ZHOU
Chinese Journal of Clinical Medicine 2024;31(2):251-256
Aortic stenosis(AS)is a structural change in aortic valve caused by congenital or acquired factors,and its incidence increases with age.Transcatheter aortic valve replacement(TAVR)is a safe and feasible minimally invasive treatment for severe AS.Since it was first approved by FDA in 2011 for severe AS which cannot be treated surgically,its indications have been extended to AS patients with low to moderate surgical risk.The placed prosthetic valves could compress the atrioventricular conduction system at the aortic root,leading to the development of postoperative cardiac conduction abnormalities,for which permanent pacemaker implantation(PPMI)is a treatment option.And post-TAVR PPMI is closely related to the prognosis of AS patients.Therefore,this article reviews predictors of conduction dysfunction and PPMI after TAVR.
10.Expression and clinical significance of interleukin-31 in plasma from patients with pulmonary arterial hypertension
Zhi ZHAN ; Xiaochun ZHANG ; Shiqiang HOU ; Lihua GUAN ; Dandan CHEN ; Wenzhi PAN ; Daxin ZHOU
Chinese Journal of Clinical Medicine 2024;31(3):394-401
Objective To investigate the plasma level of interleukin-31(IL-31)in patients with pulmonary arterial hypertension(PAH)and its clinical relevance.Methods The patients who were diagnosed as PAH in Zhongshan Hospital,Fudan University from January 1,2021 to December 30,2023(PAH group)and the healthy people in the same period(control group)were selected.The clinical data and follow-up records were collected.Plasma levels of IL-31,IL-1β,IL-6,IL-10,IL-12p70,monocyte chemoattractant protein-1(MCP-1),tumor necrosis factor-α(TNF-α)and transforming growth factor-β1(TGF-β1)were detected by enzyme-linked immunosorbent assay(ELISA).Pearson correlation test was used to evaluate the correlations between IL-31 and right cardiac catheterization parameters,echocardiography parameters and blood indices in patients with PAH.Cox proportional hazard model was used to analyze the prognostic factors of patients in PAH group.Results A total of 50 patients with PAH and 22 healthy controls were included.There was no significant difference in age,gender,body mass index and left ventricular ejection fraction between the two groups.Compared with the control group,the plasma level of IL-31 in the PAH group was significantly higher(168.82[149.14,177.26]pg/mL vs 152.76[145.58,159.41]pg/mL,P=0.001).Pearson correlation test showed that the plasma level of IL-31 in PAH patient was positively correlated with mean pulmonary artery pressure(r=0.652,P<0.001)and pulmonary vascular resistance(r=0.651,P<0.001),but was negatively correlated with tricuspid annular plane systolic excursion(r=-0.496,P<0.001).Cox proportional hazard model showed that higher plasma level of IL-31 was an independent predictor of readmission for heart failure/all-cause mortality in patients with PAH(HR=1.130,95%CI 1.052-1.214,P=0.001).Conclusions Plasma level of IL-31 may be significantly increased in patients with PAH and be positively correlated with the severity of PAH,and elevated level of IL-31 is predictive of poor prognosis in PAH patients.

Result Analysis
Print
Save
E-mail