1.Novel X-Clip transcatheter edge-to-edge repair system for treating severe functional mitral regurgitation: The first case report
Jiaqi DAI ; Da ZHU ; Shouzheng WANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(04):567-570
For patients with moderate-to-severe functional mitral regurgitation (FMR) who continue to experience heart failure symptoms despite optimized medical and device therapy, transcatheter mitral valve edge-to-edge repair (TEER) is increasingly becoming a reliable treatment option. With the continuous research and development and improvement of TEER-related devices, there are currently dozens of domestically developed TEER devices undergoing clinical trials in China. In this study, we report the first case of a patient with severe FMR treated with the X-Clip® TEER system. The patient, a 60-year-old male, suffered FMR attributed to dilated cardiomyopathy. Preoperative transthoracic echocardiography showed severe mitral regurgitation (4+). He underwent percutaneous repair using the X-Clip® system, and immediate postoperative ultrasound showed mild mitral regurgitation. At the 1-month follow-up, the patient’s symptoms and New York Heart Association (NYHA) functional class improved, and a follow-up transthoracic echocardiogram showed mild mitral regurgitation (1+).
2.Application value of venous excess ultrasound score (VExUS Score) in patients with sepsis complicated acute kidney injury
Wei DA ; Tiantian ZHU ; Xiaobo WANG ; Peipei LIANG ; Xiaodong XIE ; Rui CHEN ; Ran LI ; Zhenxing DING ; Hong ZHANG
Chinese Journal of Emergency Medicine 2024;33(3):312-316
Objective:To evaluate the effect of venous excess ultrasound score (VExUS Score) in the acute kidney injury(AKI) in Patients with sepsis, so as to reduce the risk of disease and improve the prognosis of patients.Methods:This experiment was a single-center prospective cohort study. Include septic patients with AKI who were admitted to the Department of Emergency Intensive Care Unit of the First Affiliated Hospital of Anhui Medical University from February 2022 to February 2023, Those with inadequate window, inferior vena cava (IVC) thrombus, age<18 years and known case of cirrhosis with portal hypertension were excluded from the study. Patients underwent ultrasound examination with serial determination till AKI resolved or patient is initiated on dialysis.Results:Totally 86 patients were enrolled for the study. The mean age was (60.43±15.48) with 50 (58.1%) males. Mean sequential organ failure assessment (SOFA) score was (6.23±1.87). 38 patients (44.2%) were in AKI stage 1, while 24 patients (27.9%) were in AKI stage 2 and stage 3 each. 52 patients (60.5%) had VExUS grade Ⅲ. Resolution of AKI injury showed significant correlation with improvement in VExUS grade ( p value 0.003). Similarly, there was significant association between changes in VExUS grade and fluid balance ( p value 0.005). There was no correlation between central venous pressure (CVP), left ventricular function, and right ventricular function with change in VExUS grade. Conclusions:The study shows a significant correlation between the VExUS Score and AKI staging, With improvement in kidney function, there is decline in the VExUS grade as well. Moreover VExUS Score might reliably demonstrate venous congestion and aid in the clinical decision to perform fluid removal.
3.Study and Practice on Intelligent Classification of Medical Safety Incidents Based on BERT Model
Congpu ZHAO ; Da YUAN ; Pujue ZHU ; Jiong ZHOU ; Zheng CHEN ; Hua PENG
Journal of Medical Informatics 2024;45(1):27-32,38
Purpose/Significance To improve the classification and evaluation mode of medical safety incidents,and to improve work efficiency and timeliness.Method/Process The data of previous medical safety incidents are pre-processed,BERT model is used for training,testing and iterative optimization,and an intelligent classification and prediction model for medical safety incidents is built.Re-sult/Conclusion The model is used to classify 466 medical safety incidents reported by clinical departments from January to November 2022,and F1 value reaches 0.66.The application of BERT model in the classification and evaluation of medical safety incidents can im-prove work efficiency and timeliness,and help timely intervene in medical safety risks.
4.Efficacy and safety of recombinant human anti-SARS-CoV-2 monoclonal antibody injection(F61 injection)in the treatment of patients with COVID-19 combined with renal damage:a randomized controlled exploratory clinical study
Ding-Hua CHEN ; Chao-Fan LI ; Yue NIU ; Li ZHANG ; Yong WANG ; Zhe FENG ; Han-Yu ZHU ; Jian-Hui ZHOU ; Zhe-Yi DONG ; Shu-Wei DUAN ; Hong WANG ; Meng-Jie HUANG ; Yuan-Da WANG ; Shuo-Yuan CONG ; Sai PAN ; Jing ZHOU ; Xue-Feng SUN ; Guang-Yan CAI ; Ping LI ; Xiang-Mei CHEN
Chinese Journal of Infection Control 2024;23(3):257-264
Objective To explore the efficacy and safety of recombinant human anti-severe acute respiratory syn-drome coronavirus 2(anti-SARS-CoV-2)monoclonal antibody injection(F61 injection)in the treatment of patients with coronavirus disease 2019(COVID-19)combined with renal damage.Methods Patients with COVID-19 and renal damage who visited the PLA General Hospital from January to February 2023 were selected.Subjects were randomly divided into two groups.Control group was treated with conventional anti-COVID-19 therapy,while trial group was treated with conventional anti-COVID-19 therapy combined with F61 injection.A 15-day follow-up was conducted after drug administration.Clinical symptoms,laboratory tests,electrocardiogram,and chest CT of pa-tients were performed to analyze the efficacy and safety of F61 injection.Results Twelve subjects(7 in trial group and 5 in control group)were included in study.Neither group had any clinical progression or death cases.The ave-rage time for negative conversion of nucleic acid of SARS-CoV-2 in control group and trial group were 3.2 days and 1.57 days(P=0.046),respectively.The scores of COVID-19 related target symptom in the trial group on the 3rd and 5th day after medication were both lower than those of the control group(both P<0.05).According to the clinical staging and World Health Organization 10-point graded disease progression scale,both groups of subjects improved but didn't show statistical differences(P>0.05).For safety,trial group didn't present any infusion-re-lated adverse event.Subjects in both groups demonstrated varying degrees of elevated blood glucose,elevated urine glucose,elevated urobilinogen,positive urine casts,and cardiac arrhythmia,but the differences were not statistica-lly significant(all P>0.05).Conclusion F61 injection has initially demonstrated safety and clinical benefit in trea-ting patients with COVID-19 combined with renal damage.As the domestically produced drug,it has good clinical accessibility and may provide more options for clinical practice.
5.Current applications of transcatheter edge-to-edge tricuspid valve repair
Chun-Mei XIE ; Meng-Qi SHEN ; Da ZHU ; Shou-Zheng WANG ; Zhi-Ling LUO ; Xiang-Bin PAN
Chinese Journal of Interventional Cardiology 2024;32(1):45-50
Tricuspid regurgitation(TR)is a common heart valve disease.According to the pathogenesis,TR can be divided into primary(organic)and secondary(functional)regurgitation,of which functional TR accounts for more than 90%.Patients with severe TR have poor prognosis and poor drug treatment,and surgery(valvuloplasty)is the main treatment.At present,transcatheter edge-to-edge tricuspid valve repair(T-TEER)has become an essential program of transcatheter treatment for TR,providing minimally invasive treatment for TR patients who cannot undergo surgery or are at high risk of surgery.T-TEER reduces the degree of regurgitation by clamping leaflets,and is currently in the early stage of research and development exploration and clinical validation,mainly for functional TR.T-TEER devices have also made significant progress(TriClip,PASCAL),and Chinese-made novel-designed T-TEER devices are also undergoing clinical trials(DragonFly-TTM,SQ-Kyrin-TTM,NeoBlazarTM).This paper reviews the current applications and research progress of T-TEER.
6.An in vitro evaluation of the hydromechanical properties on transcatheter edge-to-edge repair
Hao WANG ; Da ZHU ; Zhi-Qian LU ; Zhao-Ming HE ; Li LIU ; Xiang-Bin PAN
Chinese Journal of Interventional Cardiology 2024;32(2):89-95
Objective To establish a method for testing isolated mitral valve in vitro and quantitatively evaluate the effect of transcatheter edge-to-edge repair technology(TEER)on functional mitral regurgitation(FMR)(non-A2-P2 regurgitation).Methods In this study,an FMR(non-A2-P2 regurgitation)model was developed by dilating the annulus orifice and displacing the papillary muscle in isolated porcine mitral valve.The hydrodynamics characteristics of 6 valves were tested by a pulsatile flow testing system under different physiological and pathological conditions before and after TEER.Results The results show that the valve regurgitation improved from moderate-severe[regurgitant fraction(60.2±17.5)%]to mild-moderate[regurgitant fraction(34.7±12.0)%]by repair(P<0.001).The EOA[(3.8±1.6)cm2 vs.(2.2±0.5)cm2,P<0.001]and the forward cross valve pressure difference[(1.8±1.3)mmHg vs.(3.8± 1.8)mmHg,P<0.001],which characterize the forward flow performance of the valve,were compared before and after repair,and the differences were statistically significant.At the same time,the repair caused valve stenosis(the effective orifice area decreased by 40%and the positive differential pressure increased by 110%),but the valves was still within the normal physiological range,and no iatrogenic stenosis was caused.Conclusions It can be seen that TEER has an effect on FMR.This study provides validation and evaluation methods in vitro for expanding indications and improving TEER,and reference for developing standards of transcatheter valve repair testing in vitro.
7.Application of 3D printing in the preoperative evaluation of transcatheter aortic valve replacement for patients at risk of coronary artery obstruction:two case reports
Jia-Qi DAI ; Shou-Zheng WANG ; Da ZHU ; Xiang-Bin PAN
Chinese Journal of Interventional Cardiology 2024;32(2):116-120
Transcatheter aortic valve replacement(TAVR)is currently one of the main therapeutic strategies for aortic valve disease.Preoperative imaging assessment is crucial for operation project planning and prevention of procedure-associated complications.Different from planar image reconstruction,3D printing technology can accurately depict the anatomical structure of the aortic root.It enables further assessment of operative risk and therapeutic strategy through in vitro simulation,especially for assessing the risk of coronary artery obstruction and planning interventional procedures.Here,we report on two patients who underwent a 3D printing aortic root anatomical simulation model,followed an by in vitro balloon dilatation/valve implantation test,to evaluate the risk of coronary artery obstruction suggested by CT angiography planar image reconstruction before TAVR.
8.Analysis of Cardiac Reverse Remodeling After Transcatheter Edge-to-edge Repair of Mitral Regurgitation due to Various Etiologies and Experience of Echocardiography Application
Zhiling LUO ; Xiaoli DONG ; Qiuzhe GUO ; Yuanzheng WANG ; Jin LI ; Yunfei ZHOU ; Shuanglan YU ; Da ZHU ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2024;39(3):234-241
Objectives:To evaluate the valvular and cardiac function,cardiac reverse remodeling at 6-month after transcatheter edge-to-edge repair(TEER)for patients with functional and degenerative mitral valve regurgitation,and summarize the experience of echocardiography application. Methods:The clinical data of 93 patients with moderate to severe mitral regurgitation(MR)treated with TEER and completed 6-month follow-up in Yunnan Fuwai Cardiovascular Hospital from July 2022 to February 2023 were retrospectively analyzed.Patients were divided into functional mitral regurgitation(FMR)and degenerative mitral regurgitation(DMR)groups according to MR etiology.The valve characteristic parameters,as well as valvular function,chamber volume and cardiac functional parameters before and at 6 months after operation were compared.The key points of echocardiography application were summarized. Results:Among all patients,71 were FMR and 22 were DMR.There were differences in valve structure between the two groups.Mitral TEER were successfully accomplished and all patients completed 6-month follow-up.The key points of echocardiography application included:valve structure analysis,atrial septal puncture location,device delivery process monitoring and image optimization during clamping process.The mitral regurgitation grade and NYHA grade were significantly improved in all patients at 6 months after TEER(P<0.05),and the mean mitral valve pressure gradient was higher than that before operation(P<0.05).Left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV)and left atrial volume index in FMR group were significantly decreased(P<0.05),while left ventricular and left atrial volume in DMR group remained unchanged(P>0.05).There were no significant changes in left ventricular ejection fraction and left ventricular global strain in both groups during the observation period(P>0.05).The changes of LVEDV and LVESV before and after operation were more significant in FMR group than those in DMR group(P<0.05). Conclusions:Mitral TEER can reduce the degree of regurgitation and improve cardiac function in the early postoperative period for moderate and severe MR patients with different etiologies.There are differences in preoperative valve structure and postoperative cardiac reverse remodeling between FMR and DMR patients.Echocardiography is an important imaging technique for the evaluation and monitoring process before,during and post mitral TEER.
9.Bioequivalence study of olmesartan medoxomil tablet in Chinese healthy subjects
Na SHAN ; Da-Hai JIANG ; Lin-Lin MIAO ; Zhen-Li REN ; Peng-Bo JIN ; Pei-Qi HAO ; Li AN ; Hong ZHU ; Yong XIN ; Guang-De YANG ; Feng LIU
The Chinese Journal of Clinical Pharmacology 2024;40(20):3033-3037
Objective To study the bioequivalence of test and reference olmesartan tablet in Chinese healthy subjects after single dose under fasting and fed conditions.Methods A single-center,random,open,single-dose,two-preparations,double-period,crossover study was adopted.A total of 48 healthy adult male and female subjects(24 cases of fasting test and 24 cases of fed test)were included in the random crossover administration.Single oral dose 20 mg of test and reference were taken under fasting and postprandial conditions,respectively.Plasma concentration of olmesartan in plasma were determined by liquid chromatography tandem mass spectrometry.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin 8.0 software.Results The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the fasting group were as follows:Cmax were(653.06±133.53)and(617.37±151.16)ng·mL-1,AUC0-t were(4 201.18±1 035.21)and(4 087.38±889.99)ng·mL-1·h,AUC0-∞ were(4 254.30±1 058.90)and(4 135.69±905.29)ng·mL-1·h.The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the postprandial group were as follows:Cmax were(574.78±177.05)and(579.98±107.74)ng·mL-1,AUC0-t were(3 288.37±866.06)and(3 181.51±801.06)ng·mL-1·h,AUC0-∞ were(3 326.11±874.26)and(3 242.01±823.09)ng·mL-1·h.Under fasting and postprandial conditions,the 90%confidence intervals of the main pharmacokinetic parameters of the test and reference preparations are both 80.00%-125.00%.Conclusion Under fasting and postprandial conditions,a single oral dose of test and reference preparations olmesartan tablets in Chinese healthy adult volunteers showed bioequivalence.
10.Pure echocardiography-guided implantation and localization of transcatheter left ventricular assist pump: A report of two cases
Da ZHU ; Shouzheng WANG ; Wenbin OUYANG ; Hong QIU ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(11):1690-1693
Transcatheter left ventricular assist pump (LVAP) is widely used in cardiogenic shock, post-circulatory hypoperfusion syndrome and high-risk percutaneous coronary intervention (PCI), and its application scenarios cover various complex environments such as ICU, operating room, emergency department and catheterization room. It is important to quickly and accurately implant the transcatheter LVAP and monitor its position in real time. This paper reported 2 male patients with high-risk PCI, aged 47 and 45 years, both with triple coronary artery disease and reduced ejection fraction (<35%). The domestically produced transcatheter LVAP was implanted using an echocardiography guidance technology system, and PCI treatment was performed under the assistance of the interventional pump. The operation was smooth, and the interventional pump assisted for 1 h in 2 patients, and the pump was successfully removed. There were no obvious complications related to the pump and PCI after the operation, and the patients were discharged smoothly.

Result Analysis
Print
Save
E-mail