1.Expression and activity analysis of Clostridium difficile toxin B type 2
Xing-Hao LIN ; Kai ZHANG ; Meng-Jie WANG ; Ming YANG ; Han-Yang GU ; Xiao-Lan XUE ; Yong-Neng LUO ; Da-Zhi JIN ; Hui HU
Chinese Journal of Zoonoses 2024;40(6):498-503
This study was aimed at creating an engineered strain of Bacillus subtilis for efficient expression of biologically active type 2 toxin B(TcdB2)derived from a highly virulent strain of Clostridium difficile.The TcdB2 gene was cloned from ST1/RT027 strain genome DNA,incorporated into the PHT01 vector,and then transformed into B.subtilis strain WB800N for prokaryotic expression.Cell toxicity assays revealed that the recombinant TcdB2 exhibited cytotoxic effects in various cells.The engineered B.subtilis strain effectively expressed biologically active TcdB2,thus providing a basis for further exploration of the pathogenic mechanisms of highly virulent strains of C.difficile and establishing a foundation for potential vaccine can-didate targets.
2.BRAF V600E mutation and clinicopathologic analysis of papillary thyroid carcinoma in Air Force flight peronnel
Guangxin ZHOU ; Li XIAO ; Huijuan ZHU ; Junjie DU ; Li CUI ; Guoli GU ; Haojun GUAN ; Yukun TAO ; Huijing ZHU ; Jinzheng HOU ; Da ZHANG
Military Medical Sciences 2024;48(11):838-842
Objective To investigate the characteristics and clinicopathology of v-raf murine sarcoma viral oncogene homolog Bl(BRAF)V600E mutations in papillary thyroid carcinoma(PTC)in Air Force flight personnel.Methods Data of cases and test results of BRAF V600E mutation were collected from Air Force aviators pathologically diagnosed with PTC.A univariate analysis of the relationship between BRAF V600E mutations and clinicopathologic features was performed.Results The overall rate of BRAF V600E mutations among 55 PTC flight crew members was 70.91%.The univariate analysis showed that the number of lymph node metastases in the BRAF V600E mutated group was larger than in the BRAF V600E unmutated group,and the proportion of BRAF V600E mutations in flight crews at intermediate risk of recurrence was higher than that in those at low risk of recurrence(P<0.05).The presence or absence of BRAF V600E mutations did not affect the results of medical evaluation of PTC in flight personnel.Conclusion The rate of PTC BRAF V600E mutations in Air Force flight crews is similar to that of the general Chinese population.BRAF V600E mutations are associated with an increased number of lymph node metastases and risk of recurrence,and follow-up is recommended for flight personnel with PTC,especially those with BRAF V600E mutations.
3.Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome (version 2024)
Junyu WANG ; Hai JIN ; Danfeng ZHANG ; Rutong YU ; Mingkun YU ; Yijie MA ; Yue MA ; Ning WANG ; Chunhong WANG ; Chunhui WANG ; Qing WANG ; Xinyu WANG ; Xinjun WANG ; Hengli TIAN ; Xinhua TIAN ; Yijun BAO ; Hua FENG ; Wa DA ; Liquan LYU ; Haijun REN ; Jinfang LIU ; Guodong LIU ; Chunhui LIU ; Junwen GUAN ; Rongcai JIANG ; Yiming LI ; Lihong LI ; Zhenxing LI ; Jinglian LI ; Jun YANG ; Chaohua YANG ; Xiao BU ; Xuehai WU ; Li BIE ; Binghui QIU ; Yongming ZHANG ; Qingjiu ZHANG ; Bo ZHANG ; Xiangtong ZHANG ; Rongbin CHEN ; Chao LIN ; Hu JIN ; Weiming ZHENG ; Mingliang ZHAO ; Liang ZHAO ; Rong HU ; Jixin DUAN ; Jiemin YAO ; Hechun XIA ; Ye GU ; Tao QIAN ; Suokai QIAN ; Tao XU ; Guoyi GAO ; Xiaoping TANG ; Qibing HUANG ; Rong FU ; Jun KANG ; Guobiao LIANG ; Kaiwei HAN ; Zhenmin HAN ; Shuo HAN ; Jun PU ; Lijun HENG ; Junji WEI ; Lijun HOU
Chinese Journal of Trauma 2024;40(5):385-396
Traumatic supraorbital fissure syndrome (TSOFS) is a symptom complex caused by nerve entrapment in the supraorbital fissure after skull base trauma. If the compressed cranial nerve in the supraorbital fissure is not decompressed surgically, ptosis, diplopia and eye movement disorder may exist for a long time and seriously affect the patients′ quality of life. Since its overall incidence is not high, it is not familiarized with the majority of neurosurgeons and some TSOFS may be complicated with skull base vascular injury. If the supraorbital fissure surgery is performed without treatment of vascular injury, it may cause massive hemorrhage, and disability and even life-threatening in severe cases. At present, there is no consensus or guideline on the diagnosis and treatment of TSOFS that can be referred to both domestically and internationally. To improve the understanding of TSOFS among clinical physicians and establish standardized diagnosis and treatment plans, the Skull Base Trauma Group of the Neurorepair Professional Committee of the Chinese Medical Doctor Association, Neurotrauma Group of the Neurosurgery Branch of the Chinese Medical Association, Neurotrauma Group of the Traumatology Branch of the Chinese Medical Association, and Editorial Committee of Chinese Journal of Trauma organized relevant experts to formulate Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome ( version 2024) based on evidence of evidence-based medicine and clinical experience of diagnosis and treatment. This consensus puts forward 12 recommendations on the diagnosis, classification, treatment, efficacy evaluation and follow-up of TSOFS, aiming to provide references for neurosurgeons from hospitals of all levels to standardize the diagnosis and treatment of TSOFS.
4.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
5.Factors influencing the caring behaviors of primary family caregivers of older adults with dementia: A cross-sectional study
Journal of Korean Gerontological Nursing 2024;26(2):146-157
This study aims to identify factors influencing the caring behavior of the primary caregivers of older adults with dementia at home. Methods: A total of 125 primary family caregivers, responsible for the care of older adults with dementia across eight dementia care centers, participated in the study. Data were collected from August 1 through September 8, 2022, and analyzed using t-tests, analysis of variance, the Scheffé test, Pearson’s correlation, and multiple linear regression. Results: Participants had a mean age of 47.4±14.2 years, and the mean score for caring behavior was 3.89±0.40. Caring behavior was influenced by the availability of help (β=.22, p=.015), the educational level of older adults with dementia (middle school β=.32, p=.008; high school β=.24, p=.045), care experience evaluation (β=.21, p=.023), and family resilience (β=.22, p=.014). The explanatory power was 25.4% (F=6.27, p<.001, adjusted R²=.25). Conclusion: To enhance the caring behavior of primary caregivers for older adults with dementia at home, nursing interventions that positively impact dementia care experiences are necessary. Regular access to community resources for assistance is crucial. Additionally, programs should be developed to strengthen family resilience, enabling family members to support each other during challenging situations. Emphasizing education is essential to enhance awareness of care aspects among primary caregivers of older adults with dementia.
6.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
7.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
8.Salmonellosis outbreaks linked to eggs at 2 gimbap restaurants in Korea
Jun Suk EUN ; Joohyun HAN ; Ji-Hyun LIM ; Eunkyung SHIN ; Junyoung KIM ; Da-Jung KO ; Jaeil YOO ; Sungil KIM ; Jin Sook KIM ; Jung Sub PARK ; Ji-Hyuk PARK
Epidemiology and Health 2024;46(1):e2024036-
OBJECTIVES:
Salmonellosis outbreaks occurred at 2 restaurants 2 days apart, and an epidemiological investigation was conducted to determine whether the outbreaks were connected.
METHODS:
Case studies were conducted for both outbreaks. Stool samples were collected from individuals, and food samples were collected from the restaurants. Pulsed-field gel electrophoresis (PFGE) and whole-genome sequencing analyses were performed on outbreak-related Salmonella enterica serovar Enteritidis (Salmonella Enteritidis) isolates. Traceback investigations were also conducted for the ingredients from gimbap restaurants A and B.
RESULTS:
In total, 106 people from gimbap restaurant A and 5 from gimbap restaurant B met the case definition. Salmonella Enteritidis was detected in samples from 2 food handlers, 22 patients, and 1 food (iceberg lettuce) at gimbap restaurant A and from 1 patient at gimbap restaurant B. According to PFGE, all isolates were identified as SEGX01.089. The molecular typing of all isolates showed the same pattern, and the genetic distance was close according to phylogenetic analysis. Eggs were the only food ingredient that was supplied to both gimbap restaurants.
CONCLUSIONS
The outbreaks were caused by Salmonella Enteritidis, and the source of infections was suspected to be contaminated eggs. To prevent foodborne outbreaks of Salmonella, restaurants should heat eggs sufficiently, and egg farms need to establish management systems that prevent Salmonella infections.
9.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
10.Clinicopathological features and prognosis of clear cell papillary renal cell carcinoma
Yufeng GU ; Jianping DA ; Yulin ZHOU ; Silun GE ; He MIAO ; Xiaodong ZHAO ; Le QU ; Wenquan ZHOU ; Song XU
Journal of Modern Urology 2023;28(3):186-191
【Objective】 To investigate the clinicopathological features and prognosis of clear cell papillary renal cell carcinoma (CCPRCC). 【Methods】 The clinicopathological and follow-up data of 40 CCPRCC patients treated during Jun. 2011 and Oct.2021 were retrospectively analyzed. The prognosis was compared with that of 40 cases of clear cell renal cell carcinoma (ccRCC) and 19 cases of papillary renal cell carcinoma (PRCC) treated in the same period. Survival analysis was performed by Log-rank test and Kaplan-Meier survival curves were plotted. 【Results】 Among the 40 patients, 28 were male and 12 were female, aged 31-84 years; 38 cases had unilateral and 2 cases had bilateral tumors; 3 cases had multifocal lesions. All patients received surgery. The maximum diameter of the masses ranged from 3.0 to 95.0 mm, with an average of (27.6±18.1) mm. Pathological grade was Fuhrman 1-2 in all cases. Immunohistochemical tests were positive for CK7 and CA-IX. During the follow-up of 5-129 (average 56) months, 1 case died after bone metastasis, 2 had ipsilateral recurrence, and 1 developed primary esophageal cancer. CCPRCC patients had a significantly better prognosis than CCRCC (P<0.001) and PRCC (P=0.005) patients, while there was no significant difference in the prognosis between CCRCC and PRCC patients (P=0.93). 【Conclusions】 CCPRCC has low malignancy. The diagnosis relies on characteristic pathological and immunohistochemical features. Surgery is an effective treatment. CCPRCC has a better overall prognosis than CCRCC and PRCC.

Result Analysis
Print
Save
E-mail