1.Empirical study of input, output, outcome and impact of community-based rehabilitation stations
Xiayao CHEN ; Ying DONG ; Xue DONG ; Zhongxiang MI ; Jun CHENG ; Aimin ZHANG ; Didi LU ; Jun WANG ; Jude LIU ; Qianmo AN ; Hui GUO ; Xiaochen LIU ; Zefeng YU
Chinese Journal of Rehabilitation Theory and Practice 2026;32(1):83-89
ObjectiveTo investigate the present situation of input, output, outcome and impact of all registered community-based rehabilitation stations in Inner Mongolia in China, and analyze how the input predict the output, outcome and impact. MethodsFrom March 1st to April 30th, 2025, a questionnaire survey was conducted on all registered community-based rehabilitation stations in Inner Mongolia, covering four dimensions: input, output, outcome and impact. A total of 1 365 questionnaires were distributed. The input included four items: laws and policies, human resources, equipment and facilities, and rehabilitation information management. The output included two items: technical paths and benefits/effectiveness. The outcome included three items: coverage rates, rehabilitation interventions and functional results. The impact included two items: health and sustainability. Each item contained several questions, all of which were described in a positive way. Each question was scored from one to five. A lower score indicated that the situation of the community-based rehabilitation station was more in line with the content described in the question. Regression analysis was performed using the total score of each item of input dimension as independent variables, and the total scores of the output, outcome and impact dimensions as dependent variables. ResultsA total of 1 262 valid questionnaires were collected. The mean values of input, output, outcome and impact of community-based rehabilitation stations were 1.827 to 1.904, with coefficient of variation of 45.892% to 49.239%. The regression analysis showed that, rehabilitation information management, human resources, and laws and policies significantly predicted the output dimension (R² = 0.910, P < 0.001). Meanwhile, all four items in the input dimension predicted both the outcome (R² = 0.850, P < 0.001) and impact dimensions (R² = 0.833, P < 0.001). ConclusionInput, output, outcome and impact of the community-based rehabilitation stations in Inner Mongolia were generally in line with the content of the questions, although some imbalances were observed. Additionally, the input of community-based rehabilitation stations could significantly predict their output, outcome and impact.
2.Manufacture and mechanical property on zirconia abutments with a titanium base in dental implant restoration
Huan WANG ; Jing LU ; Ying LI ; Maohua MENG ; Jiayu SHU ; Yuncai LUO ; Wenjie LI ; Qiang DONG
Chinese Journal of Tissue Engineering Research 2025;29(10):2171-2177
BACKGROUND:With the development of computer-aided design and computer-aided manufacturing technology,zirconia abutments with a titanium base are widely used in clinic due to its good application advantages,but there are still some problems and a lack of consensus design standards. OBJECTIVE:To review the fabrication methods of Ti-base zirconia abutment,and the effect of abutment connection,emergence design,abutment angle,and bonding on mechanical properties of Ti-base zirconia abutment. METHODS:Relevant literature published from 2010 to 2023 was searched in CNKI and PubMed databases with the search terms"zirconia abutment,titanium base"in Chinese and English,respectively.The search time limit was extended for some classical literature.The relevant literature was obtained through inclusion and exclusion criteria,and 57 eligible documents were included for review. RESULTS AND CONCLUSION:It is recommended that clinicians try to select antirotational titanium bases or rotational titanium bases with a Morse taper connection.Implants should be placed in the correct axial angulation of not more than 15° or with an inclination to the palatal side when using angled zirconia abutments.When a≥30° labial inclination is followed for implant placement,the bite force must be decreased effectively to reduce the risk of mechanical and biological complications of implants,abutments,and prostheses.Ti-base zirconia abutments with a higher gingival height should be selected,and its restorative angle should not exceed 40°.Multilink Hybrid Abutment could be the first choice for extraoral bonding of zirconia abutment to titanium bases.
3.Effect of sorafenib and donafenib on the pharmacokinetics of ertugliflozin in rats
Yanru DENG ; Gexi CAO ; Bin YAN ; Ying LI ; Zhanjun DONG
Journal of Clinical Hepatology 2025;41(1):92-98
ObjectiveTo investigate the effect of sorafenib and donafenib on the pharmacokinetics of ertugliflozin in rats, and to provide a theoretical basis for drug combination in clinical practice. MethodsA total of 24 male Sprague-Dawley rats were randomly divided into groups A, B, C, and D, with 6 rats in each group. The rats in groups A and B were given sorafenib control solvent and sorafenib (100 mg/kg), respectively, by gavage for 7 consecutive days, followed by ertugliflozin (1.5 mg/kg) by gavage on day 7. Blood samples were collected from the angular vein plexus at different time points, and ultra-performance liquid chromatography-tandem mass spectrometry was used to determine the mass concentration of ertugliflozin and plot the plasma concentration-time curves, while the non-compartment model in DAS 2.1.1 software was used to calculate related pharmacokinetic parameters. The independent-samples t test was used for comparison of normally distributed continuous data between two groups, and the Mann-Whitney U test was used for comparison of non-normally distributed continuous data between two groups. ResultsCompared with group A, group B had significant increases in the AUC0-t and AUC0-∞ of the plasma concentration-time curve of ertugliflozin (both P<0.05), significant prolongation of t1/2, MRT0-t, and MRT0-∞ (all P<0.05), and a significant reduction in CLZ/F (P<0.05). Compared with group C, group D had significant increases in the AUC0-t and AUC0-∞ of ertugliflozin (both P<0.05), significant prolongation of Tmax, t1/2, MRT0-t, and MRT0-∞ (all P<0.01), and significant reductions in VZ/F and CLZ/F (both P<0.05). ConclusionBoth sorafenib and donafenib can affect the pharmacokinetics of ertugliflozin in rats and significantly increase the plasma exposure of ertugliflozin. The efficacy and adverse drug reactions of ertugliflozin should be closely monitored during combined use in clinical practice and the dose should be adjusted when necessary to avoid the potential risk of drug interaction.
4.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
5.Optimization of Rh blood group antigen precision transfusion strategy across multiple hospital campuses by PDCA circle
Qiming YING ; Luyan CHEN ; Kedi DONG ; Yiwen HE ; Yating ZHAN ; Yexiaoqing YANG ; Feng ZHAO ; Dingfeng LYU
Chinese Journal of Blood Transfusion 2025;38(1):106-111
[Objective] To explore the effectiveness of applying the PDCA (Plan-Do-Check-Act) cycle to enhance the compatibility rate of five Rh blood group antigen phenotypes between donors and recipients across multiple hospital campuses. [Methods] Clinical blood transfusion data from May to July 2022 were selected. Specific improvement measures were formulated based on the survey results, and the PDCA cycle management model was implemented from August 2022. The post-intervention phase spanned from August 2022 to October 2023. The Rh phenotype compatibility rate, the detection rate of Rh system antibodies, and the proportion of Rh system antibodies among unexpected antibodies were compared between the pre-intervention phase (May to July 2022) and the post-intervention phase. [Results] After the continuous improvement with the PDCA cycle, the compatibility rate for the five Rh blood group antigen phenotypes between donors and recipients from August to October 2023 reached 81.90%, significantly higher than the 70.54% recorded during the pre-intervention phase (May to July 2022, P<0.01), and displayed a quarterly upward trend (β=0.028, P<0.05). The detection rate of Rh blood group system antibodies (β=-9.839×10-5, P<0.05) and its proportion among all detected antibodies (β=-0.022, P<0.05) showed a quarterly decreasing trend, both demonstrating a negative correlation with the enhanced compatibility rate (r values of -0.981 and -0.911, respectively; P<0.05). [Conclusion] The implementation of targeted measures through the PDCA cycle can effectively increase the compatibility rate of five Rh blood group antigen phenotypes between donors and recipients, reduce the occurrence of unexpected Rh blood group antibodies, thereby lowering the risk of transfusion and enhancing the quality and safety of medical care.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
8.Effects of Shugan jieyu capsules on the pharmacokinetics of voriconazole,rivaroxaban and apixaban in rats
Ying LI ; Chunhui SHAN ; Yizhen SONG ; Yinling MA ; Zhi WANG ; Caihui GUO ; Zhanjun DONG
China Pharmacy 2025;36(12):1470-1475
OBJECTIVE To investigate the effects of multiple doses of Shugan jieyu capsules on the pharmacokinetics of voriconazole, rivaroxaban and apixaban in rats. METHODS Male SD rats were randomly divided into voriconazole group (30 mg/kg), rivaroxaban group (2 mg/kg), apixaban group (0.5 mg/kg), Shugan jieyu capsules+voriconazole group (145 mg/kg+30 mg/kg), Shugan jieyu capsules+rivaroxaban group (145 mg/kg+2 mg/kg), Shugan jieyu capsules+apixaban group (145 mg/kg+0.5 mg/kg), with 6 rats in each group. After the rats in each group were consecutively administered solvent (0.5% sodium carboxymethyl cellulose solution) or Shugan jieyu capsules by intragastric gavage for 8 days, they were respectively given voriconazole, rivaroxaban and apixaban solution by intragastric gavage on the 8th day. Blood samples were then collected at different time points (in voriconazole group, rivaroxaban group and corresponding drug combination groups, blood was collected before administration and at 0.17, 0.34, 0.5, 0.75, 1, 1.5, 2, 3, 4, 5, 6, 8, 10 and 12 hours post-administration; in apixaban group and corresponding drug combination group, blood was collected before administration and at 0.08, 0.17, 0.25, 0.34, 0.5, 0.75, 1, 3, 5, 7, 10 and 12 hours post-administration). Ultra-high performance liquid chromatography-tandem mass spectrometry method was employed to determine the mass concentrations of voriconazole, rivaroxaban and apixaban in rat plasma. The main pharmacokinetic parameters of these drugs were calculated using a non-compartmental model, and the comparisons were made between groups. RESULTS Compared with single drug group, after multiple administrations of Shugan jieyu capsules, AUC0-t, AUC0-∞ and cmax of voriconazole were significantly decreased, while CLz/F was significantly increased, and tmax was also significantly prolonged (P<0.05). For rivaroxaban and apixaban, their tmax values were both significantly prolonged (P<0.05). However, there were no statistically significant differences in the other pharmacokinetic parameters between the two groups (P>0.05). CONCLUSIONS The combination of Shugan jieyu capsules can decrease the exposure, increase the clearance, and delay the peak concentration of oral voriconazole. However, it does not affect the exposure levels of rivaroxaban and apixaban, but it does delay the time to reach peak concentration for both drugs.
9.Hemolytic disease of the fetus and newborn caused by Rh system anti-c antibodies: a case report and literature review
Luyan CHEN ; Dong XIANG ; Dingfeng LYU ; Zhenyun LIU ; Xinyi ZHU ; Shuan TAO ; Qiming YING ; Wei LIANG
Chinese Journal of Blood Transfusion 2025;38(6):843-848
Objective: To summarize the laboratory findings of a case of hemolytic disease of the fetus and newborn (HDFN) caused by Rh system anti-c antibodies and to review the literature, so as to explore the characteristics of anti-c HDFN. Methods: The ABO blood type, Rh blood type, direct antiglobulin test (DAT) results, and the presence of unexpected antibodies and their titers were determined by serological methods. The cases of anti-c HDFN in our laboratory in China and abroad were statistically analyzed, and the incidence of severe HDFN caused by anti-c, anti-D and anti-E was compared. Results: The blood type of the child was B (Rh CcDee) with a positive DAT. Anti-c antibody was detected in both serum and eluate, with a serum antibody titer of 4. The mother’s blood type was AB (Rh CCDee) with a negative DAT, and anti-c antibody was detected in the serum with a titer of 128. Among 20 cases of anti-c HDFN, 17 were DAT positive, and 9 (45%, 9/20) underwent blood transfusion or exchange transfusion. The incidence of severe HDFN was 47.60% (10/21) for anti-c, 47.60% (10/21) for anti-D and 31.30% (5/16) for anti-E. Conclusion: Maternal pregnancy and/or blood transfusion are the main reasons for the production of Rh alloantibodies such as anti-c. The prevention and management of anti-c should be similar to that of anti-D. Rh antigen-matched (five antigens of Rh blood group) transfusion is necessary for women of childbearing age to avoid antibody production, and Rh typing and antibody screening during prenatal examination is recommended to ensure early detection, intervention and treatment.
10.Analysis of the nonlinear relationship between hypothermic machine perfusion parameters and delayed graft function and construction of an optimized predictive model based on sampling algorithms
Boqing DONG ; Chongfeng WANG ; Yuting ZHAO ; Huanjing BI ; Ying WANG ; Jingwen WANG ; Zuhan CHEN ; Ruiyang MA ; Wujun XUE ; Yang LI ; Xiaoming DING
Organ Transplantation 2025;16(4):582-590
Objective To analyze the nonlinear relationship between hypothermic machine perfusion (HMP) parameters and delayed graft function (DGF) and optimize the construction of a predictive model for DGF. Methods The data of 923 recipients who underwent kidney transplantation from deceased donors were retrospectively analyzed. According to the occurrence of DGF, the recipients were divided into DGF group (n=823) and non-DGF group (n=100). Donor data, HMP parameters and recipient data were analyzed for both groups. The nonlinear relationship between HMP parameters and the occurrence of DGF was explored based on restricted cubic splines (RCS). Over-sampling, under-sampling and balanced sampling were used to address the imbalance in the proportion of DGF to construct logistic regression predictive models. The area under the curve (AUC) of each model was compared in the validation set, and a nomogram model was constructed. Results Donor BMI, cold ischemia time of the donor kidney, and HMP parameters (initial and final pressures, resistance, and perfusion time) were significantly different between the DGF and non-DGF groups (all P<0.05). The RCS analysis revealed a threshold-like nonlinear relationship between HMP parameters and the risk of DGF. Among the models constructed using different sampling methods, the balanced sampling model had the highest AUC. Using this model, a nomogram was constructed to stratify recipients based on risk scores. Recipients in the high-risk group had higher serum creatinine levels at 1, 6, and 12 months after kidney transplantation compared to those in the low-risk group (all P<0.05). Conclusions There is a nonlinear relationship between HMP parameters and the risk of DGF, and the threshold is helpful for organ quality assessment and monitoring of graft function after transplantation. The predictive model for DGF constructed on the base of balanced sampling algorithms helps perioperative decision-making and postoperative graft function monitoring of kidney transplantation.

Result Analysis
Print
Save
E-mail