1.Efficacy of intravascular ultrasound versus coronary angiographic guided drug-eluting stent implantation in the treatment of left main coronary artery disease: a meta-analysis.
Xiao Hang YUAN ; Xin HU ; Yan FANG ; Meng Ting JIANG ; Yan HAN ; Huan Huan FENG ; Lei GAO
Chinese Journal of Cardiology 2023;51(1):66-72
Objective: To compare the efficacy of intravascular ultrasound (IVUS) and coronary angiography guided drug eluting stent (DES) implantation for the treatment of left main coronary artery (LMCA) lesions. Methods: Randomized controlled trials (RCT) and observational studies, which compared IVUS with coronary angiography guided DES implantation for the treatment of LMCA lesions published before August 2021 were searched in PubMed, Embase and Cochrane Library databases. Baseline data, interventional procedures and endpoint events of each study were collected. The primary endpoint was major cardiovascular adverse events (MACE), and the secondary endpoints were all-cause death, cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) and target vessel revascularization (TVR). The Newcastle-Ottawa Scale (NOS) and the Cochrane Collaboration Risk of Bias tool were used to evaluate the quality of the included studies. Results: Nine studies were included, including 3 RCT and 6 observational studies, with a total of 5 527 cases of LMCA. All the 6 observational studies had NOS scores≥6, and the 3 RCT had a low risk of overall bias. The results of meta-analysis showed that compared with coronary angiography guided group, MACE rate (OR=0.55, 95%CI 0.47-0.66, P<0.001), all-cause death (OR=0.56, 95%CI 0.43-0.74, P<0.001), cardiac death (OR=0.43, 95%CI 0.30-0.61, P<0.001), MI (OR=0.64, 95%CI 0.52-0.79, P<0.001), TLR (OR=0.49, 95%CI 0.28-0.86, P=0.013) and TVR (OR=0.77, 95%CI 0.60-0.98, P=0.037) were all significantly lower in the IVUS guided group. Conclusions: Compared with angiography guided, IVUS guided PCI with DES implantation in LMCA lesions could significantly reduce the risk of MACE, death, MI, TLR and TVR. IVUS is thus superior to coronary angiography for guiding PCI treatment among patients with LMCA.
Humans
;
Coronary Artery Disease/complications*
;
Coronary Angiography
;
Drug-Eluting Stents/adverse effects*
;
Treatment Outcome
;
Percutaneous Coronary Intervention/methods*
;
Ultrasonography, Interventional/methods*
;
Risk Factors
;
Myocardial Infarction/etiology*
3.Correlation between Characteristics of Coronary Plaque and Chinese Medicine Syndromes of Coronary Heart Disease: A Cross-Sectional Study Analysed by Intravascular Ultrasound.
Dan-Ping XU ; Jun-Peng XU ; Zhi-Ling HE ; Guang-Ming PAN ; Xia WANG
Chinese journal of integrative medicine 2022;28(9):840-846
OBJECTIVE:
To analyse the correlation between the characteristics of coronary plaque in coronary heart disease (CHD) patients with phlegm-blood stasis syndrome (PBS) and blood stasis syndrome (BSS).
METHODS:
Patients were divided into different groups based on Chinese medicine (CM) syndrome differentiation. The baseline demographics and clinical variables were collected from the medical records. Additionally, the characteristics of plaque and pathological manifestations in coronary artery were evaluated using intravascular ultrasound (IVUS).
RESULTS:
A total of 213 CHD patients were enrolled in two groups: 184 were diagnosed with PBS and the remaining 29 were diagnosed with BSS. There were no significant differences in age, body mass index, proportions of patients with high blood pressure, diabetes mellitus, smoking, hyperlipidemia, history of coronary artery bypass graft and percutaneous coronary intervention, medications, index from cardiac ultrasound image, blood lipids and C-reactive protein between the two groups (P>0.05), except gender, weight and proportions of IVUS observed target vessels (P<0.05 or P<0.01). More adverse events such as acute myocardial infarction (P=0.003) and unstable angina (P=0.048) were observed in BSS. Additionally, dissection, thrombus and coronary artery ectasia were significantly increased in BSS (P<0.05 or P<0.01). In contrast, PBS had more patients with stable angina and chronic total occlusion with significantly higher SYNTAX (synergy between percutaneous coronary intervention with Taxus and coronary artery bypass surgery) scores (P<0.05 or P<0.01). Moreover, dense-calcium was significantly elevated in PBS (P<0.01).
CONCLUSIONS
Coronary plaque characteristics were correlated with different CM syndromes. Patients with PBS were associated with a higher degree of calcified plaque and severe coronary artery stenosis, indicating poor clinical prognosis but with a low probability of acute coronary events. In contrast, the degree of calcified plaque in patients with BSS remained relatively low, and plaque was more vulnerable, resulting in the possibility of the occurrence of acute coronary events remaining high.
Coronary Angiography
;
Coronary Artery Disease/diagnostic imaging*
;
Coronary Vessels/pathology*
;
Cross-Sectional Studies
;
Humans
;
Medicine, Chinese Traditional
;
Percutaneous Coronary Intervention
;
Plaque, Atherosclerotic/diagnostic imaging*
;
Syndrome
;
Ultrasonography, Interventional/methods*
4.Effect of lipoprotein
Jiajia LIU ; Yu CAO ; Zhe SHENG
Journal of Central South University(Medical Sciences) 2021;46(3):249-256
OBJECTIVES:
To analyze the effect of hyperlipoproteinemia (α) on immediate expansion after coronary stent implantation guided by intravascular ultrasound (IVUS).
METHODS:
A total of 160 patients (175 lesions) with coronary heart disease diagnosed by coronary artery angiography, who were performed percutaneous intervention guided by IVUS in the Department of Cardiology, Third Xiangya Hospital, Central South University, were enrolled retrospectively.According to the concentration of lipoproteina, the patients were divided into 2 groups: a hyperlipoproteinemia (α) group and a control group. Cardiac ejection fraction was measured with echocardiography. Logistic regression was used to analyze the influential factors for hyperlipoproteinemia (α). The target vessel was examined by IVUS to analyze the immediate expansion effect of hyperlipoproteinemia (α) after stent implantation.
RESULTS:
The mean stent expansion index, lesion length, stent number, stent symmetry index and posterior balloon diameter were (94.73±18.9)%, (52.92±29.1) mm, (2.11±0.85), (83.62±13.07)%, and (9.46±2.00) mm in the hyperlipoproteinemia (α) group, respectively. Compared with the control group, there were significantly difference (all
CONCLUSIONS
Hyperlipoproteinemia (α) appears to be a predictor of stent underexpansion, and the decreased creatinine clearance rate is an independent risk factor for hyperlipoproteinemia (α).
Coronary Angiography
;
Coronary Artery Disease/surgery*
;
Humans
;
Lipoproteins
;
Percutaneous Coronary Intervention/adverse effects*
;
Retrospective Studies
;
Risk Factors
;
Stents/adverse effects*
;
Treatment Outcome
;
Ultrasonography, Interventional
6.Long-term outcomes of intravascular ultrasound-guided drug-eluting stent implantation in patients with chronic kidney disease: ULTIMATE CKD subgroup analysis.
Xiao Fei GAO ; Shu LU ; Leng HAN ; Xue Song QIAN ; Zhen GE ; Xiang Quan KONG ; Jing KAN ; Jun Jie ZHANG ; Shao Liang CHEN
Chinese Journal of Cardiology 2021;49(2):136-142
Objective: To explore the long-term effect of intravascular ultrasound (IVUS) guidance on patients with chronic kidney disease (CKD) undergoing drug-eluting stent (DES) implantation. Methods: Data used in this study derived from ULTIMATE trial, which was a prospective, multicenter, randomized study. From August 2014 to May 2017, 1 448 patients with coronary heart disease undergoing DES implantation were selected from 8 domestic centers and randomly divided into two groups in the ratio of 1∶1 (IVUS or coronary angiography guided stent implantation). A total of 1 443 patients with the baseline serum creatine available were enrolled. The patients were divided into CKD group and non CKD group. CKD was defined as the estimated glomerular filtration rate (eGFR) derived from Cockcroft Gault (CG) formula< 60 ml·min-1·1.73 m-2 for at least 3 months. Primary endpoint of this study was target vessel failure (TVF) at 3 years, including cardiac death, target vessel myocardial infarction, and clinically-driven target vessel revascularization. Kaplan Meier method was used for survival analysis, and log rank test was used to compare the occurrence of end-point events in each group. Cox proportional hazards model was used to calculate HR and 95%CI, and interaction was tested. Multivariate Cox regression was used to analyze the independent influencing factors of TVF. Results: A total of 1 443 patients with coronary heart disease were enrolled in this study, including 349 (24.2%) patients in CKD group and 1 094 patients in non CKD group. In CKD group, IVUS was used to guide stent implantation in 180 cases and angiography was used in 169 cases; in non CKD group, IVUS was used to guide stent implantation in 543 cases and angiography was used in 551 cases. Three-year clinical follow-up was available in 1 418 patients (98.3%). The incidence of TVF in CKD group was 12.0% (42/349), which was higher than that in non CKD group (7.4% (81/1 094) (P = 0.01). The difference was mainly due to the higher cardiac mortality in CKD group (4.6% (16/349) vs. 1.5% (16/1094), P<0.001). In CKD group, the incidence of TVF in patients who underwent IVUS guided stent implantation was lower than that in angiography guided stent implantation (8.3% (15/180) vs. 16.0% (27/169), P = 0.03). There was no significant difference in the incidence of TVF between IVUS guided stent implantation and angiography guided stent implantation in non CKD group (5.9% (32/543) vs. 8.9% (49/551), P = 0.06), and there was no interaction (P = 0.47). Multivariate Cox regression analysis showed that IVUS guidance (HR = 0.56, 95%CI 0.39-0.81, P = 0.002), CKD (HR = 1.83, 95%CI 1.17-2.87, P = 0.010) and stent length (every 10 mm increase) (HR = 1.11, 95%CI 1.04-1.19, P = 0.002) were independent risk factors for TVF within 3 years after DES implantation. Conclusions: CKD patients undergoing DES implantation are associated with a higher risk of 3-year TVF. More importantly, the risk of TVF could be significantly decreased through IVUS guidance in comparison with angiography guidance in patients with CKD.
Coronary Angiography
;
Coronary Artery Disease/surgery*
;
Drug-Eluting Stents
;
Humans
;
Percutaneous Coronary Intervention
;
Prospective Studies
;
Renal Insufficiency, Chronic
;
Treatment Outcome
;
Ultrasonography, Interventional
7.Feasibility and Applicability of Wireless Handheld Ultrasound Measurement of Carotid Intima-Media Thickness in Patients with Cardiac Symptoms
Albert Youngwoo JANG ; Jeongwon RYU ; Pyung Chun OH ; Jeonggeun MOON ; Wook Jin CHUNG
Yonsei Medical Journal 2020;61(2):129-136
disease in asymptomatic patients has been criticized for the high costs and large number of patients required for detecting one patient with coronary artery disease (CAD). In order to overcome the low cost-effectiveness thereof, we investigated the feasibility of an economic wireless handheld ultrasound (WHUS) device for CIMT measurement in symptomatic patients.MATERIALS AND METHODS: A total of 100 consecutive patients with cardiac symptoms were enrolled. CIMT was measured in all patients. Coronary angiography was performed in 75 patients indicated for the exam.RESULTS: The mean of maximal CIMT measured from left/right common carotid artery and bulb (max-CIMT) by the WHUS device showed excellent agreement [intraclass correlation coefficient (ICC)=0.960] with a standard ultrasound device and great interobserver repeatability (ICC>0.9 between all observers). Receiver operating characteristic curve analysis showed that the predictive power for CAD was improved when max-CIMT and plaque information (plaque≥2) was added [area under the curve (AUC): 0.838] to the traditional clinical CV risk factors (AUC: 0.769). The cutoff values for CAD prediction with the standard device and the WHUS device were 1.05 mm (AUC: 0.807, sensitivity: 0.78, specificity: 0.53) and 1.10 mm (AUC: 0.725, sensitivity: 0.98, specificity: 0.27), respectively.CONCLUSION: max-CIMT measured by a WHUS device showed excellent agreement and repeatability, compared with standard ultrasound. Combined max-CIMT and plaque information added predictive power to the traditional clinical CV risk factors in detecting high-risk CAD patients.]]>
Carotid Artery, Common
;
Carotid Intima-Media Thickness
;
Coronary Angiography
;
Coronary Artery Disease
;
Humans
;
Mass Screening
;
Risk Factors
;
ROC Curve
;
Sensitivity and Specificity
;
Ultrasonography
;
Wireless Technology
8.Application of virtual histological intravascular ultrasound in plaque composition assessment of saphenous vein graft diseases.
Jing GAO ; Yue-Ying WANG ; Yin LIU
Chinese Medical Journal 2019;132(8):957-962
OBJECTIVE:
Saphenous vein grafts disease (SVGD) is a common complication after coronary artery bypass graft (CABG) and normally treated by percutaneous coronary intervention (PCI). The most common complication after SVG-PCI is slow or no-reflow. It is known that the no-reflow phenomenon occurs in up to 15% of the SVG-PCI and is associated with high risk of major adverse cardiac events (MACEs) and mortality, therefore, it is important to investigate the factors that could predict the clinical outcome of PCI for risk stratification and guiding interventions. In recent years, the spectral analysis of intravascular ultrasound (IVUS) radiofrequency data (virtual histology-IVUS [VH-IVUS]) has been used to provide quantitative assessment on both plaque compositions and morphologic characteristics.
DATA SOURCES:
The PubMed, Embase, and Central databases were searched for possible relevant studies published from 1997 to 2018 using the following index keywords: "Coronary artery bypass grafting," "Saphenous venous graft disease," "Virtual histology-intravascular ultrasound," "Virtual histology-intravascular ultrasound," and "Percutaneous coronary intervention."
STUDY SELECTION:
The primary references were Chinese and English articles including original studies and literature reviews, were identified and reviewed to summarize the advances in the application of VH-IVUS techniques in situ vascular and venous graft vascular lesions.
RESULTS:
With different plaque components exhibiting a defined spectrum, VH-IVUS can classify atherosclerotic plaque into four types: fibrous tissue (FT), fibro fatty (FF), necrotic core (NC), and dense calcium (DC). The radiofrequency signal is mathematically transformed into a color-coded representation, including lipid, fibrous tissue, calcification, and necrotic core. Several studies have demonstrated the independent relationship between VH-IVUS-defined plaque classification or plaque composition and MACEs, but a significant association between plaque components and no-reflow after PCI in acute coronary syndrome. In recent years, VH-IVUS are applied to assess the plaque composition of SVGD, based on the similarity of pathophysiological mechanisms between coronary artery disease (CAD) and SVGD, further studies with the larger sample size, the long-term follow-up, multicenter clinical trials may be warranted to investigate the relationship between plaque composition of saphenous vein graft (SVG) by VH-IVUS and clinical outcomes in patients with SVGD undergoing PCI.
CONCLUSIONS
In degenerative SVG lesions, VH-IVUS found that plaque composition was associated with clinical features, future studies need to explore the relationship between VH-IVUS defined atherosclerotic plaque components and clinical outcomes in SVGD patients undergoing PCI, an innovative prediction tool of clinical outcomes can be created.
Coronary Artery Bypass
;
adverse effects
;
Coronary Artery Disease
;
pathology
;
Female
;
Humans
;
Male
;
Percutaneous Coronary Intervention
;
adverse effects
;
Plaque, Atherosclerotic
;
pathology
;
Saphenous Vein
;
pathology
;
Ultrasonography, Interventional
9.The Current Status of Intervention for Intermediate Coronary Stenosis in the Korean Percutaneous Coronary Intervention (K-PCI) Registry
Jin Ho KIM ; Woonggil CHOI ; Ki Chang KIM ; Chang Wook NAM ; Bum Kee HONG ; June Hong KIM ; Doo Soo JEON ; Jang Whan BAE ; Sang Hyun KIM ; Keon Woong MOON ; Byung Ryul CHO ; Doo Il KIM ; Jae Sik JANG
Korean Circulation Journal 2019;49(11):1022-1032
BACKGROUND AND OBJECTIVES: Intermediate coronary lesion that can be under- or over-estimated by visual estimation frequently results in stenting of functionally nonsignificant lesions or deferral of percutaneous coronary intervention (PCI) of significant lesions inappropriately. We evaluated current status of PCI for intermediate lesions from a standardized database in Korea. METHODS: We analyzed the Korean percutaneous coronary intervention (K-PCI) registry data which collected a standardized PCI database of the participating hospitals throughout the country from January 1, 2014, through December 31, 2014. Intermediate lesion was defined as a luminal narrowing between 50% and 70% by visual estimation and then compared whether the invasive physiologic or imaging study was performed or not. RESULTS: Physiology-guided PCI for intermediate lesions was performed in 16.8% for left anterior descending artery (LAD), 9.8% for left circumflex artery (LCX), 13.2% for right coronary artery (RCA). PCI was more frequently performed using intravascular ultrasound (IVUS) than using fractional flow reserve (FFR) for coronary artery segments (27.7% vs. 13.9% for LAD, 32.9% vs. 8.1% for LCX, and 33.8% vs. 10.8% for RCA). In accordance with or without FFR, PCI for intermediate lesions was more frequently performed in the hospitals with available FFR device than without FFR, especially in left main artery (LM), proximal LAD lesion (40.9% vs. 5.9% for LM, 24.6% vs 7.6% for proximal LAD). CONCLUSIONS: These data provide the current PCI practice pattern with the use of FFR and IVUS in intermediate lesion. More common use of FFR for intermediate lesion should be encouraged.
Arteries
;
Coronary Artery Disease
;
Coronary Stenosis
;
Coronary Vessels
;
Fractional Flow Reserve, Myocardial
;
Korea
;
Percutaneous Coronary Intervention
;
Phenobarbital
;
Stents
;
Ultrasonography
10.Multimodal intravascular photoacoustic and ultrasound imaging.
Biomedical Engineering Letters 2018;8(2):193-201
The rupture of atherosclerotic plaques is the leading cause of death in developed countries. Early identification of vulnerable plaque is the essential step in preventing acute coronary events. Intravascular photoacoustic (IVPA) technology is able to visualize chemical composition of atherosclerotic plaque with high specificity and sensitivity. Integrated with intravascular ultrasound (IVUS) imaging, this multimodal intravascular IVPA/IVUS imaging technology is able to provide both structural and chemical compositions of arterial walls for detecting and characterizing atherosclerotic plaques. In this paper, we present representative multimodal IVPA/IVUS imaging systems and discuss current scientific innovations, potential limitations, and prospective improvements for characterization of coronary atherosclerosis.
Atherosclerosis
;
Cause of Death
;
Coronary Artery Disease
;
Developed Countries
;
Plaque, Atherosclerotic
;
Prospective Studies
;
Rupture
;
Sensitivity and Specificity
;
Ultrasonography*

Result Analysis
Print
Save
E-mail