1.Expert consensus on prognostic evaluation of cochlear implantation in hereditary hearing loss.
Xinyu SHI ; Xianbao CAO ; Renjie CHAI ; Suijun CHEN ; Juan FENG ; Ningyu FENG ; Xia GAO ; Lulu GUO ; Yuhe LIU ; Ling LU ; Lingyun MEI ; Xiaoyun QIAN ; Dongdong REN ; Haibo SHI ; Duoduo TAO ; Qin WANG ; Zhaoyan WANG ; Shuo WANG ; Wei WANG ; Ming XIA ; Hao XIONG ; Baicheng XU ; Kai XU ; Lei XU ; Hua YANG ; Jun YANG ; Pingli YANG ; Wei YUAN ; Dingjun ZHA ; Chunming ZHANG ; Hongzheng ZHANG ; Juan ZHANG ; Tianhong ZHANG ; Wenqi ZUO ; Wenyan LI ; Yongyi YUAN ; Jie ZHANG ; Yu ZHAO ; Fang ZHENG ; Yu SUN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(9):798-808
Hearing loss is the most prevalent disabling disease. Cochlear implantation(CI) serves as the primary intervention for severe to profound hearing loss. This consensus systematically explores the value of genetic diagnosis in the pre-operative assessment and efficacy prognosis for CI. Drawing upon domestic and international research and clinical experience, it proposes an evidence-based medicine three-tiered prognostic classification system(Favorable, Marginal, Poor). The consensus focuses on common hereditary non-syndromic hearing loss(such as that caused by mutations in genes like GJB2, SLC26A4, OTOF, LOXHD1) and syndromic hereditary hearing loss(such as Jervell & Lange-Nielsen syndrome and Waardenburg syndrome), which are closely associated with congenital hearing loss, analyzing the impact of their pathological mechanisms on CI outcomes. The consensus provides recommendations based on multiple round of expert discussion and voting. It emphasizes that genetic diagnosis can optimize patient selection, predict prognosis, guide post-operative rehabilitation, offer stratified management strategies for patients with different genotypes, and advance the application of precision medicine in the field of CI.
Humans
;
Cochlear Implantation
;
Prognosis
;
Hearing Loss/surgery*
;
Consensus
;
Connexin 26
;
Mutation
;
Sulfate Transporters
;
Connexins/genetics*
2.Adult carotid body tumors in Northwest China: a multicenter, retrospective cross-sectional study
Wenyu XIE ; Hongchen ZHANG ; Yuan FENG ; Zheming YUE ; Lei ZHANG ; Shuhui DAI ; Jun REN ; Chunming XIAN ; Jie ZHOU ; Bin ZHANG ; Xia LI
Chinese Journal of Neuromedicine 2024;23(1):34-41
Objective:To analyze the clinical and epidemiological characteristics of adult carotid body tumors (CBTs) in Northwest China to provide references for early diagnosis and treatment of CBTs.Methods:A multicenter, retrospective, non-intervention epidemiological investigation was conducted on adult CBTs patients who were hospitalized from January 1, 2011 to June 30, 2023 in 7 Class A tertiary hospitals in Northwest China (Departments of Neurosurgery, First Affiliated Hospital of Air Force Medical University, Second Affiliated Hospital of Lanzhou University, People's Hospital of Gansu Province, 940 th Hospital of PLA Joint Logistic Support Force, People's Hospital of Qinghai Province, General Hospital of Ningxia Medical University, People's Hospital of Ningxia Hui Autonomous Region). Medical records were collected in these patients, and they were divided into 2 groups according to their average altitude residence: high altitude group (≥1 500 m) and low altitude group (<1 500 m); meanwhile, these patients were divided into Shamblin type I, type II and type III groups according to Shamblin classification criteria; differences in general data and clinical features among patients from different altitude groups or Shamblin subgroups were compared. Independent influencing factors for Shamblin type III CBTs were analyzed by multivariate ordered Logistic regression. Results:(1) A total of 359 patients were enrolled in the study, including 276 females and 83 males, aged (48.80±12.07) years; 211 patients were into the high altitude group and 148 into the low altitude group; 165 patients were into Shamblin type I group, 146 into Shamblin type II group, and 48 into Shamblin type III group. (2) Compared with those in the low altitude group, patients in the high altitude group had higher proportion of females, older age, lower proportion of Han nationality, higher proportion of Shamblin type I, smaller tumor volume, lower platelet count, higher red blood cell count, hematocrit, hemoglobin level, platelet distribution width and mean platelet volume, and higher large platelet percentage, with significant differences ( P<0.05). (3) Compared with those in the Shamblin type I group, patients in the Shamblin type III group had younger age, lower resident altitude, larger tumor volume, longer time interval from onset to diagnosis, higher proportion of unintentional tumor discovery, larger volume of intraoperative blood loss, lower hemoglobin level, hematocrit, mean erythrocyte volume, and mean hemoglobin concentration, decreased erythrocyte distribution width variable coefficient, and increased platelet count, with significant differences ( P<0.05). Compared with those in the Shamblin type II group, patients in Shamblin type III group had younger age, larger tumor volume, longer time interval from onset to diagnosis, larger volume of intraoperative blood loss, lower hemoglobin, hematocrit and mean erythrocyte volume, higher erythrocyte distribution width variable coefficient and platelet count, with significant differences ( P<0.05). (4) Age ( OR=0.960, 95% CI: 0.942-0.977, P<0.001), residence altitude ( OR=0.992, 95% CI: 0.990-0.999, P=0.020) and time interval from onset to diagnosis ( OR=1.009, 95% CI: 1.005-1.014, P<0.001) were independent influencing factors for Shamblin type III CBTs. Conclusions:More females than males are noted in patients with adult CBTs in Northwest China, and more CBTs patients live at high altitude, with Shamblin type I enjoying the highest proportion. More female and old patients lived at high altitude is noted than those lived at low altitude; patients with Shamblin type III have the youngest age, lowest altitude, and longest time interval from onset to diagnosis. CBTs patients with young age, low residence altitude, and long time interval from onset to diagnosis are more likely to develop Shamblin type III.
3.Determination of hydrogen sulfide in Blood by LC-MS/MS
Xiaojun WU ; Ge QIN ; Chunming WEI ; Peng ZHAO ; Jiayi LI ; Jing CHANG ; Yunfeng ZHANG
Chinese Journal of Forensic Medicine 2024;39(1):55-58
Objective To establish a method for determining hydrogen sulfide(H2S)in blood and apply it to practical cases.Methods A delute solution was achieved by adding 0.8 mL saturated borax solution into 0.2 mL blood sample was diluted with.1 mL acetonitrile solution containing 0.1%formic acid was then taken in a test tube,followed by adding 0.1 mL dilute solution and 0.1 mL thiozine aqueous solution(1%).After thorough mixing,the mixture was left to stand for 30 minutes.Subsequently,the sample was subjected to liquid chromatography-tandem mass spectrometry(LC-MS/MS)analysis after centrifugation and membrane filtration.Results The results showed that H2S exhibited good linearity within the concentration range of 10~2 000 ng/mL,with the R2 value of 0.998 5.The detection limit was 5 ng/mL,and the quantification limit was 10 ng/mL.In three cases of H2S poisoning,sulfur ions were detected in the blood of the deceased individuals,with concentrations ranging from 0.17 to 0.56 μg/mL.Conclusion For the first time,this study established a LC-MS/MS method for determining H2S in blood,which can meet the detection needs of H2S poisoning cases.
4.Augmented reality navigation system for assisting CT-guided puncture of pulmonary nodules in dog models
Tao ZHOU ; Nannan SUN ; Xiaobo FAN ; Xiu WANG ; Zhengyi XIE ; Yuqing SUN ; Chenxiao YANG ; Chunming XU ; Shouyu ZHANG ; Zhuangfei MA ; Min ZHANG ; Shouqiang JIA
Chinese Journal of Interventional Imaging and Therapy 2024;21(1):38-41
Objective To observe the value of augmented reality(AR)navigation system for assisting CT-guided puncture of pulmonary nodules in dog models.Methods Five healthy dogs were selected,and 4 target lung rings were implanted in each dog to build pulmonary nodule models.Deferring to crossover design,CT-guided punctures were performed with or without AR navigation 2 and 4 weeks after successful modeling,respectively,while punctures with AR navigation were regarded as AR group and the others as conventional group,respectively.The time duration of puncturing,the times of CT scanning,of needle adjustment,and the deviation distance between needle pinpoint to the center of pulmonary nodule shown on three-dimensional reconstruction were compared between groups.Results The duration time of puncture in AR group and conventional group was(13.62±5.11)min and(20.16±4.76)min,respectively.In AR group,the times of CT scanning,of needle adjustment,and the deviation distance was 2.40±0.50,2.75±0.44 and(2.94±1.92)mm,respectively,while in conventional group was 3.10±0.64,3.70±0.57 and(4.90±3.38)mm,respectively.The introduction of AR navigation was helpful to shortening the duration of puncture,reducing times of CT scanning and needle adjustment,also decreasing positioning error of needle pinpoint(all P<0.05).In contrast,the variance of puncture sequences and dogs had no obvious effect on the results(both P>0.05).Conclusion AR navigation system could improve accuracy and efficiency in CT-guided puncture of pulmonary nodules in dog models.
5.The accuracy of augmented reality-based percutaneous angle localization system in liver puncture
Min ZHANG ; Shuncheng HE ; Ying LI ; Tao ZHOU ; Chenxiao YANG ; Chunming XU ; Shouyu ZHANG ; Shouqiang JIA
Journal of Interventional Radiology 2024;33(5):507-511
Objective To evaluate the application value of percutaneous angle positioning system based on augmented reality in improving the accuracy of liver puncture.Methods A canine liver with an embedded marking ring was used as the target for puncture.A skilled physician with over 5 years of experience in liver puncture and a novice physician with limited experience in liver puncture separately performed liver puncture using either the augmented reality-based percutaneous angle localization system(navigation)or CT-guided technique alone(non-navigation).The corresponding puncturing data of non-navigation skilled group(Group A),non-navigation non-skilled group(Group B),navigation skilled group(Group C),and navigation non-skilled group(Group D)were obtained.The differences in the evaluation indicators,including the number of CT scans,number of needle adjustment,time spent for operation,and distance of error,between Group A and Group B,between Group C and Group D,between Group A and Group C,and between Group B and Group D,were analyzed.Results Statistically significant differences in the number of CT scans,number of needle adjustment,time spent for operation,and distance of error existed between Group A and Group B,between Group A and Group C,and between Group B and Group D(all P<0.0 5),while the differences in the number of CT scans,number of needle adjustment,time spent for operation,and distance of error between Group C and Group D were not statistically significant(all P>0.05)Conclusion In performing liver puncture,the use of percutaneous angle localization system can reduce the number of CT scans,number of needle adjustment,time spent for operation and distance of error,and improve the puncture accuracy as well,which provides a basis for the clinical utilization of this system and the employment of this system-guided puncture technology in primary hospitals.(J Intervent Radiol,2024,33:507-511)
6.Comparative study on short-term clinical efficacy of unilateral biportal and percutaneous interlaminar endoscopic in the treatment of L5S1 disc herniation
Jionghui CHEN ; Chunming HUANG ; Xiaochuan LI ; Cheng JIANG ; Wei WANG ; Yonglong CHEN ; Zhenwu ZHANG ; Shaojian LUO ; Mingnan LU ; Gen LAN
Journal of Clinical Surgery 2024;32(6):634-638
Objective To compare the short-term clinical effects of unilateral dual-channel endoscopic discectomy(UBED)and percutaneous endoscopic intervertebral discectomy(PEID)in the treatment of L5S,Lumbar disc herniation,LDH.Methods From January 2019 to January 2021,a total of 57 cases of L5S,LDH treated by UBED or PEID were analyzed retrospectively,including 30 cases in UBED group and 27 cases in PEID group.The operation time,intraoperative fluoroscopy times,postoperative hospitalization days and surgical complications were compared between the two groups.The visual analogue scale(VAS)and oswestry disability index(ODI)were used to compare the postoperative quality of life of the two groups,and the modified MacNab criteria was used to evaluate the clinical efficacy in the last follow-up.Results The operation time of UBED group and PEID group was(75.30±8.44)minutes and(68.37±4.63)minutes,respectively,and the difference between the two groups was statistically significant(P<0.05).VAS and ODI of 1 week,3 months,1 year and 1.5 years after surgery in 2 groups were significantly decreased compared with those before surgery,with statistical significance(P<0.05).The VAS score of low back pain in UBED group was higher than that in PEID group[(3.87±1.14)points vs(2.70±0.67)points]at 1 week after surgery(P<0.05),and there was no significant difference in VAS and ODI at the other time points(P>0.05).There was no statistical difference in the results of modified MacNab criteria in the last follow-up(P>0.05).There were 2 cases of dural tear in PEID group,1 case of dural tear in UBED group and 1 case of temporary nerve root injury in PEID group after operation,all of which were cured after symptomatic treatment.Conclusion Compared with PEID,UBED has a longer operation time,more trauma and more obvious low back pain in the short term after operation.The short-term curative effect of the two operations on L5S1 LDH is similar,the incidence of complications is low,and the times of fluoroscopy are few.Both operations are safe and effective.
7.High glucose-peritoneal dialysis solution activates ceramide expression and induces peritoneal injury via Src pathway in peritoneal dialysis model mice
Tianfeng TANG ; Min ZHAO ; Yangyang XIA ; Lulu WANG ; Qingyan ZHANG ; Cheng SUN ; Chunming JIANG
Chinese Journal of Nephrology 2024;40(9):723-731
Objective:To explore the mechanism of peritoneal dialysis solution (PDS)-induced peritoneal microinflammation through activation of ceramide (CER) in peritoneal dialysis model mice.Methods:Thirty 5-week-old male C57BL/6 mice weighing about 22 g were used to set up peritoneal dialysis models, and then were randomly divided into 4 groups: sham operation group (1.5 ml sterilized water, n=7), high glucose-PDS group (1.5 ml 4.25% PDS, n=8), high glucose-PDS+ acid sphingomyelinase (ASMase) inhibitor desipramine (DES) group (1.5 ml sterilized water+10 mg/kg DES, n=8), high glucose-PDS+Src kinase inhibitor PP2 group (1.5 ml sterilized water +1 mg/kg PP2, n=7), with intraperitoneal injection once a day. After 28 days, the mice were sacrificed to retain peritoneal tissues. HE staining and Masson staining were used to observe the histological changes of peritoneum. Immunohistochemistry was used to detect the Toll-like receptor 4 (TLR4) and macrophages. High performance liquid chromatography, liquid chromatography/mass spectrometry and immunofluorescence were used to detect the expression of ASMase and CER. Real-time quantitative PCR was used to detect the mRNA levels of c-Src, p-Src, interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α). Western blotting was used to detect the protein levels of c-Src, and p-Src. Enzyme-linked immunosorbent assay was used to detect the serum C reactive protein (CRP), IL-6 and TNF-α. Results:(1) High glucose-PDS led to peritoneal hyperplasia, collagen deposition and fibrosis in the peritoneal dialysis mice, indicating successful modeling. Compared with high glucose-PDS group, peritoneal hyperplasia, collagen deposition and fibrosis of mice treated with DES and PP2 were significantly improved (all P<0.05). (2) Compared with sham operation group, ASMase activation and CER level of peritoneal tissues were significantly higher in high glucose-PDS group, and DES could significantly inhibit activated ASMase and increased CER expression caused by high glucose-PDS (both P<0.05). PP2 had no significant effect on ASMase activation and CER level (both P>0.05). (3) Compared with sham operation group, there were more TLR4 and macrophage positive staining cells in peritoneal tissues in high glucose-PDS group, and the mRNA expression levels of IL-6 and TNF-α in peritoneal tissues and serum CRP, IL-6 and TNF-α were higher (all P<0.05). DES and PP2 could significantly inhibit the increased TLR4, macrophages and related inflammatory factors induced by high glucose-PDS (all P<0.05). (4) Compared with sham operation group, c-Src and p-Src mRNA and protein expression levels of peritoneal tissues in high glucose-PDS group were significantly higher (all P<0.05). PP2 significantly inhibited the increased p-Src mRNA and protein levels caused by high glucose-PDS (both P<0.05), but had no significant effect on the mRNA and protein expression levels of c-Src (both P>0.05). DES had no significant effect on the mRNA and protein expression levels of c-Src and p-Src (all P>0.05). Conclusions:High glucose-PDS may enhance the expression of CER through stimulating the activity of ASMase, phosphorylate Src, activate TLR4 and induce inflammatory damage of peritoneum in peritoneal dialysis model mice.
8.Clinical outcome of arthroscopic partial and complete repair in patients of massive rotator cuff tear
Lin LIN ; Fengyuan ZHAO ; Jiahao ZHANG ; Xin YAN ; Chunming KE ; Guoqing CUI ; Hui YAN
Chinese Journal of Orthopaedics 2024;44(14):963-969
Objective:To compare the clinical efficacy of arthroscopic partial and complete repair for massive rotator cuff tears.Methods:A total of 32 patients who underwent arthroscopic partial repair of massive rotator cuff tears in the Department of Sports Medicine, Peking University Third Hospital from March 2016 to December 2019 were retrospectively analyzed, including 15 males and 17 females, aged 62±6.8 years (range, 51-77 years), with 5 cases on the left side and 27 cases on the right side. Cause of injury: 4 cases were injured by car accident, 8 were injured by fall, and 20 had no obvious cause. 32 patients who underwent arthroscopic complete repair of massive rotator cuff tears during the same period were included according to a sample size of 1∶1 matched based on age, sex, tear size and fat infiltration index. Clinical outcomes were evaluated using the visual analogue scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES) score, University of California Los Angeles (UCLA) shoulder score, Simple Shoulder Test (SST) score, and range of motion. Fatty infiltration and cuff healing were assessed using the Goutallier and Sugaya classifications on MRI, respectively.Results:All patients successfully completed the surgery and were followed up for 46.1±11.3 months (range, 36-72 months). Preoperative and final follow-up VAS scores were 6.6±1.8 and 1.6±1.1 in the complete repair group, and 6.4±1.9 and 1.4±1.3 in the partial repair group. Both groups showed significant postoperative improvement ( P<0.05), with no significant difference between groups at the final follow-up ( t=-0.729, P=0.468). The ASES score, UCLA shoulder score, and SST at the final follow-up were 81.7±6.5, 28.6±2.9, and 9.8±2.5, respectively, in the complete repair group, and 82.4±7.3, 28.1±2.6, and 9.1±1.9 in the partial repair group, and the difference between the groups was not statistically significant ( P>0.05). In the complete repair group, one case underwent reverse shoulder replacement for rotator cuff re-tear two years after surgery, and one case developed pseudoparalysis for rotator cuff re-tear 8 months after surgery but had no significant pain and did not receive further treatment; in the partial repair group, two cases underwent tendon transposition surgery for shoulder pain. Conclusion:Arthroscopic partial repair improves shoulder function and reduces pain in patients with massive rotator cuff tears, with similar efficacy to complete repair and has high surgical safety.
9.Design and practice of general population cohort study in northeastern China
Hehua ZHANG ; Qing CHANG ; Qijun WU ; Yang XIA ; Shanyan GAO ; Yixiao ZHANG ; Yuan YUAN ; Jing JIANG ; Hongbin QIU ; Jing LI ; Chunming LU ; Chao JI ; Xin XU ; Donghui HUANG ; Huixu DAI ; Zhiying ZHAO ; Xing LI ; Xiaoying LI ; Xiaosong QIN ; Caigang LIU ; Xiaoyu MA ; Xinrui XU ; Da YAO ; Huixin YU ; Yuhong ZHAO
Chinese Journal of Epidemiology 2023;44(1):21-27
In 2016, a national one million general population cohort project was set up in China for the first time in "Precision Medicine Research" Key Project, National Key Research and Development Program of China, which consists of general population cohorts in seven areas in China. As one of the seven major areas in China, northeastern China has unique climate and specific dietary patterns, and population aging is serious in this area. And the burden of chronic and non-communicable diseases ranks tops in China. Therefore, it is of great significance to establish a large general population cohort in northeastern China to explore the area specific exposure factors related to pathogenesis and prognosis of chronic and non-communicable diseases, develop new prevention strategies to reduce the burden of the diseases and improve the population health in northeastern China. In July 2018, the general population cohort study in northeastern China was launched, the study includes questionnaire survey, health examination and blood, urine and stool sample collection and detection in recruited participants. By now, the cohort has covered all age groups, and the baseline data of 115 414 persons have been collected. This paper summarizes the design and practice of the general population cohort study in northeastern China to provide reference for related research in China.
10.Grade Evaluation of Color Sorting Lonicerae Japonicae Flos Based on HPLC Fingerprint and Index Components Combined with Multivariate Statistics
HAO Peijun ; ZHANG Linxiang ; JIN Wanjun ; NI Lin ; QIU Guoyu ; ZHAI Yusheng ; LEI Chunming ; SONG Pingshun
Chinese Journal of Modern Applied Pharmacy 2023;40(19):2694-2701
OBJECTIVE To establish the correlation evaluation and quality evaluation method of HPLC fingerprint grade of color sorting Lonicerae Japonicae Flos, and provide technical basis for the grade standard of color sorting Lonicerae Japonicae Flos. METHODS The chromatographic column was SVEA C18(250 mm×4.6 mm, 5 μm); mobile phase was acetonitrile(A)- 0.2% formic acid aqueous solution(B); gradient elution; injection volume was 10 μL; detection wave length was 245 nm; volume flow rate was 0.5 mL·min-1; column temperature was 38 ℃. The common peak determination and similarity evaluation of HPLC chromatogram data were carried out by using the Similarity Evaluation System of Traditional Chinese Medicine Chromatographic Fingerprints(Version 2012); the color sorting grade evaluation was carried out by CA, PCA and PLS-DA. The first part of Chinese Pharmacopoeia 2020 Edition was used to measure the quality control indicators, and the data were analyzed comprehensively. RESULTS A total of 28 common peaks were identified in the fingerprints, and 7 components were identified. The similarity of 24 batches of color sorting grade samples was 0.936-0.968. CA and PCA divided 28 batches of Lonicerae Japonicae Flos samples into 4 categories, which were basically consistent with the classification of color sorting, and PLS-DA achieved a discrimination result that was very consistent with the classification of color sorting. The color sorting grade was negatively correlated with the diameter, flowering rate, damage rate, and luteolin content of Lonicerae Japonicae Flos. The color sorting grade was positively correlated with chlorogenic acid, 3,5-di-O-caffeoyl quinic acid and 4,5-di-O-caffeoyl quinic acid. There was a clear correlation between the color sorting of Lonicerae Japonicae Flos and established fingerprint overall. There were differences in the quality of Lonicerae Japonicae Flos in the color sorting grade. Based on the sensory indicators of diameter, flowering rate, and damage rate, the content, diameter, flowering rate, and damage rate of luteolin showed a trend from high to low, ranging from third grade>second grade>first grade>special grade. The content of three phenolic acids showed a trend from high to low, ranging from special grade>first grade>second grade>third grade. Among the special grade, the content of three phenolic acids was the highest. CONCLUSION Combining the content of luteolin and phenolic acids as evaluation and control indicators for color selection grade is feasible and scientific, which can achieve intelligent color sorting grade production of Lonicerae Japonicae Flos grade.


Result Analysis
Print
Save