1.TCM practitioners’ attitudes and perceptions regarding the use of Ephedra sinica Stapf: An observational study
Aiwen Chang ; Xiaopeng Zhao ; Lin Zhang ; Sijia Zhao ; Zhongyi Pan ; Chenxi Song ; Yanling Fu
Journal of Traditional Chinese Medical Sciences 2024;11(4):435-442
Objective:
To understand the attitudes and perceptions of traditional Chinese medicine (TCM) practitioners in Beijing TCM hospitals regarding the use of Ephedra sinica Stapf (E. sinica, Ma Huang).
Methods:
A two-stage cross-sectional study was conducted using a questionnaire survey of TCM practitioners in Beijing TCM hospitals between April 2023 and March 2024. The questionnaire included demographic information, the clinical background of TCM practitioners, and the clinical application of E. sinica. Logistic regression analysis was used to analyze the relevant influencing factors when using E. sinica.
Results:
Of the 465 questionnaires collected, 441 were valid. Among these, 84.81% (374/441) reported having used E. sinica in clinical practice at least once. The commonly used doses of E. sinica—excluding the pediatric department—were 10 g for high doses, 6 g for medium, and 3 g for low. The three most frequently used formulas for E. sinica included Maxing Shigan decoction, Mahuang decoction, and Xiao Qing Long decoction. The most common TCM patterns treated with a high dose of E. sinica were wind-cold exterior pattern, wind-cold invading the lung, and wind and water combat with meridians congealed by cold. The top three Western medical diagnoses when using E. sinica for treatment were common cold, pneumonia, and upper respiratory tract infections. Nearly half of the respondents reported experiencing adverse reactions from the oral administration of E. sinica, with the most common being palpitations, insomnia, and restlessness. Starting with a low dose and gradually increasing it as appropriate was identified as an effective approach.
Conclusion
This study investigated the attitudes and perceptions of TCM practitioners in Beijing TCM hospitals regarding the dose–efficacy–adverse reaction relationship of E. sinica, providing a reference for the safe and effective clinical use of E. sinica.
2.Interpretation of a clinical practice guideline on the management of chronic pain associated with temporomandibular joint disorders
Chenxi LI ; Zhiqiang SONG ; Xing JIN ; Zhongcheng GONG ; Hui LIU ; Xu LIU ; Mingchao DING ; Jialin SUN ; Xing LONG ; Bo SHAO
Chinese Journal of Stomatology 2024;59(10):988-997
Temporomandibular disorders (TMD) are a heterogeneous group of diseases that affect the temporomandibular joint, chewing muscle system, dental occlusion, and even various structures throughout the body, with significant characteristics of biological-psychological-social pattern. TMD related chronic pain, as the most important clinical symptom, can result in negative emotions seriously affecting patients′ quality of life and physical and mental health. Although a variety of therapies have been previously reported to treat TMD related chronic pain, there is a lack of widely recognized therapies. Professor Jason W Busse (from Michael G DeGroote National Pain Centre, McMaster University, Hamilton ON, Canada) took the lead and collaborated with multiple internationally renowned schools/hospitals of stomatology to develop an international consensus on the management of chronic pain associated with TMD, a clinical practice guideline, which took two years and was published in December 15th, 2023 in a global top journal of clinical research The British Medical Journal. This clinical practice guideline explored the comparative effectiveness of available therapies for chronic pain associated with TMD, conditionally recommended the specific intervention for different treatment or pain relief, proposed a comprehensive, agreed, and standardized clinical practice guideline. This present article describes the methodology and key elements of the clinical practice guideline to help clinicians fully understand and appropriately apply this guidance, which could provide the references for clinical practice of TMD associated chronic pain in China.
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Progress of treatment strategies for advanced stages of chronic myeloid leukemia
Chenxi GU ; Huifang ZHAO ; Yongping SONG ; Yanli ZHANG
Journal of Leukemia & Lymphoma 2024;33(8):501-505
Chronic myeloid leukemia (CML) is a clonal hematologic malignancy. In recent years, its treatment mainly involves the application of tyrosine kinase inhibitors (TKI) targeting the BCR::ABL fusion gene, but some patients still develop drug resistance or drug intolerance during TKI treatment and enter into the advanced stages (include accelerated phase and blast crisis phase). This article reviews the research progress of novel TKI drugs, TKI combined regimens and other targeted drugs for treatment of advanced stages of CML.
7.Application of 4-dimensional automated left atrial quantification to evaluate left atrial function in adults of different ages
Tao XU ; Ying GUO ; Xinyang SONG ; Chenxi XIA ; Sixian WENG ; Junying LIU ; Chenguang YANG ; You ZHONG ; Fang WANG
Chinese Journal of Geriatrics 2024;43(8):1030-1036
Objective:This study aimed to assess left atrial function in adults across various age groups using 4-dimensional automated left atrial quantification(4D Auto LAQ)technology.The study also aimed to compare the differences in two-dimensional(2D)and four-dimensional(4D)strains of the left atrium among different age groups, with the goal of enhancing the clinical utility of 4D Auto LAQ.Methods:A total of 409 healthy volunteers were recruited for the research.Two-dimensional and four-dimensional images were obtained using a GE Vivid E95 ultrasound system with a 4Vc four-dimensional probe.The study examined variations in 2D and 4D ultrasound parameters across various age groups.Furthermore, the relationship between left atrial reservoir strain(LASr), Left atrial conduit strain(LAScd), left atrial contraction strain(LASct), and age was explored.Results:The study involved 409 volunteers, with 217 males and 192 females, who were categorized into three age groups: young(18-45 years, n=56), middle-aged(46-65 years, n=202), and elderly(>65 years, n=151).Conventional ultrasound measurements indicated changes in left atrial anterior-posterior diameter with age progression: (31.70±3.65)mm for the young group, (34.02±3.91)mm for the middle-aged group, and(35.2±4.37)mm for the elderly group( P<0.01).The 2D and 4D left atrial parameters across the age groups were as follows: LASr(2D)(%): 37.48±7.51, 30.95±8.23, 26.9±7.56( P<0.01); LA VImax(ml/m 2): 23.54±5.79, 26.33±7.6, 28.99±8.15( P<0.01); LASr(%): 31.2±17.07, 22.5±8.59, 19.49±7.47( P<0.01).Both 2D and 4D left atrial parameters exhibited significant associations with age.Specifically, the correlations between LASr(2D)(%), LAScd(2D)(%), LASr(%), LAScd(%), and age were -0.429, 0.580, -0.354, 0.298, respectively( P<0.01). Conclusions:The 4D Auto LAQ technology is efficient in assessing left atrial function across various age groups, with age playing a significant role in influencing left atrial parameters.When compared to other ultrasound parameters, both 2D and 4D left atrial strain parameters have the ability to detect differences at an early stage, making them suitable for the early screening, evaluation, and monitoring of age-related left atrial dysfunction, especially in the elderly population.
8.Research of the therapeutic effect of Yunnan Baiyao on middle aged and elderly lung cancer patients undergoing the uniportal video-assisted thoracoscopic
Chenxi LOU ; Yichen LUO ; Baijun LI ; Zhenniu LEI ; Jingwei YAN ; Wentao SONG ; Jinmin ZHENG ; Linyuan TAN ; Guanyong MO
China Modern Doctor 2024;62(24):86-89
Objective To analyze the clinical efficacy of Yunnan Baiyao in middle aged and elderly lung cancer patients undergoing the uniportal video-assisted thoracoscopic.Methods A total of 90 patients with non-small cell lung cancer meeting the criterias were screened and divided into two groups according to random number table method,which respectively received conventional treatment(control group)and Yunnan Baiyao treatment(experimental group).The perioperative period related indexes,coagulation function related indexes,and the occurrence rate of complications were observed and compared between the two groups.Results The intraoperative bleeding volume and thoracic drainage volume for the first day of experimental group were significantly lower than control group(P<0.05).However,there were no significant difference in the coagulation function related indexes between two groups before and after surgery(P>0.05).Additionally,there were also no significant difference in the occurrence rate of complication between two groups(P>0.05).Conclusion Yunnan Baiyao can reduce intraoperative bleeding volume and chest tube drainage volume for the first day,promots the recovery of patients,and has a good clinical application value.
9.Effect and potential mechanism of sodium ferulate on corneal endothelial dysfunction and CEC injury
Hui SONG ; Weihua YAO ; Chenxi YU ; Baiquan SHU ; Yi LIU ; Kang WEI
China Pharmacy 2023;34(15):1840-1846
OBJECTIVE To investigate the effect and potential mechanism of sodium ferulate (SF) on corneal endothelial dysfunction and corneal endothelial cell (CEC) injury. METHODS The male New Zealand rabbits were divided into control group, benzalkonium chloride (BAK) group and BAK+SF group, with 6 rabbits in each group. Except for control group, the other groups were given BAK into the anterior chamber to induce bullous keratopathy model, and BAK+SF group then given SF solution 200 mg/kg intraperitoneally the next day after surgery, twice a day, for consecutive 14 d. The transparency of corneal and edema of corneal stroma in each group of rabbits (before and on the 1st, 7th, and 14th day after surgery) were observed, and the corneal thickness (14th day after surgery) and intraocular pressure (1st to 14th day after surgery) were measured. On the 14th day after operation, the corneal endothelial structure was evaluated and the expressions of functionally related proteins [phalloidin, zonula occludens-1 (ZO-1), Na+/K+-ATPase, Ki67] were detected. On the 14th day after surgery, the corneal tissue was collected in BAK group, the primary rabbit CECs were isolated and cultured, and they were divided into blank group and SF groups with different mass concentrations. The cell viabilities after being cultured for different time, and the protein expressions of Ras homologous gene family A (RhoA), bone morphogenetic protein receptor 1A (BMPR1A) and BMRP2 were determined in each group. RESULTS Compared with BAK group, the transparency of corneal and edema of corneal stroma were gradually improved, and the corneal thickness was significantly decreased in BAK+SF group (P<0.05). The rabbit CECs in BAK+SF group were only damaged to zone B and showed a normal hexagonal endothelial cells structure. The protein expressions of phalloidin, ZO-1, Na+/K+-ATPase and Ki67 in BAK+SF group were significantly increased (P<0.05). When SF concentration was lower than and equal to 200 mg/L, it could promote the proliferation of rabbit CEC, in concentration manner (P<0.05) and time-dependent trend. SF at concentrations of 50, 100, and 200 mg/L could up-regulate the protein expressions of RhoA, BMPR1A and BMPR2 in concentration-dependent manner (P<0.05). CONCLUSIONS SF can improve the transparency of corneal and edema of corneal stroma in bullous keratopathy model rabbits, reduce corneal thickness, maintain the integrity of corneal endothelium structure, and promote the recovery of corneal endothelial function; this compound can promote the proliferation of CEC, the mechanism of which may be related to the activation of RhoA-ROCK-BMP pathway.
10.Application of artificial intelligence assists bone marrow cytomorphology analysis in the diagnosis and treatment of acute myeloid leukemia
Jigang XIAO ; Huijun WANG ; Wenyu CAI ; Shuying CHEN ; Ge SONG ; Xulin LU ; Chenxi LIU ; Zhigang WANG ; Chao FANG ; Yanan CHEN ; Zhijian XIAO
Chinese Journal of Laboratory Medicine 2023;46(3):274-279
Objective:To investigate the value of artificial intelligence (AI) cytomorphologic analysis system in the cytomorphological diagnosis and therapeutic evaluation of acute myeloid leukemia (AML).Methods:Bone marrow smear samples were collected from 150 patients with newly diagnosed and treated acute myeloid leukemia who were inpatients and outpatients at the Department of Institute of Hematology and Blood Diseases Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College from June 1, 2021 to July 31, 2022 for retrospective analysis. Among them, there were 50 patients in the newly diagnosed group, including 28 males and 22 females, with the onset age of 43.5(32.3,58.8)years. There were 100 patients in the post-treatment group, including 36 males and 64 females, with the onset age of 34.5(23.0,47.0)years. The results from cytomorphology expert were used as the gold standard and the Python 3.6.7 was used for analysis to evaluate the accuracy, sensitivity, and specificity of the AI cytomorphologic analysis system for blast cell recognition in AML diagnosis and treatment.Results:The proportion of blasts in AI analysis of 50 samples in the newly diagnosed group was≥20%, which met the diagnostic criteria of AML. AI analysis of blasts had an accuracy of 90.3%, sensitivity of 85.5%, and specificity of 98.0%. The correlation coefficient between AI and the proportion of blasts analyzed by experts was positively correlated( r=0.882, P<0.001). Meanwhile, in the post-treatment group, the sensitivity and specificity of AI analysis of blasts were 89.7% and 99.2%, respectively. The correlation coefficient between AI and the proportion of blasts analyzed by experts was positively correlated( r=0.957, P<0.001). According to AI analysis data, there are 8 samples in this group whose AI efficacy evaluation results on AML are inconsistent with expert analysis. Conclusion:AI cytomorphologic analysis system has high accuracy, sensitivity and specificity for blast cell recognition in AML morphological diagnosis and therapeutic evaluation.


Result Analysis
Print
Save
E-mail