1.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Identification and Potential Clinical Utility of Common Genetic Variants in Gestational Diabetes among Chinese Pregnant Women
Claudia Ha-ting TAM ; Ying WANG ; Chi Chiu WANG ; Lai Yuk YUEN ; Cadmon King-poo LIM ; Junhong LENG ; Ling WU ; Alex Chi-wai NG ; Yong HOU ; Kit Ying TSOI ; Hui WANG ; Risa OZAKI ; Albert Martin LI ; Qingqing WANG ; Juliana Chung-ngor CHAN ; Yan Chou YE ; Wing Hung TAM ; Xilin YANG ; Ronald Ching-wan MA
Diabetes & Metabolism Journal 2025;49(1):128-143
Background:
The genetic basis for hyperglycaemia in pregnancy remain unclear. This study aimed to uncover the genetic determinants of gestational diabetes mellitus (GDM) and investigate their applications.
Methods:
We performed a meta-analysis of genome-wide association studies (GWAS) for GDM in Chinese women (464 cases and 1,217 controls), followed by de novo replications in an independent Chinese cohort (564 cases and 572 controls) and in silico replication in European (12,332 cases and 131,109 controls) and multi-ethnic populations (5,485 cases and 347,856 controls). A polygenic risk score (PRS) was derived based on the identified variants.
Results:
Using the genome-wide scan and candidate gene approaches, we identified four susceptibility loci for GDM. These included three previously reported loci for GDM and type 2 diabetes mellitus (T2DM) at MTNR1B (rs7945617, odds ratio [OR], 1.64; 95% confidence interval [CI],1.38 to 1.96]), CDKAL1 (rs7754840, OR, 1.33; 95% CI, 1.13 to 1.58), and INS-IGF2-KCNQ1 (rs2237897, OR, 1.48; 95% CI, 1.23 to 1.79), as well as a novel genome-wide significant locus near TBR1-SLC4A10 (rs117781972, OR, 2.05; 95% CI, 1.61 to 2.62; Pmeta=7.6×10-9), which has not been previously reported in GWAS for T2DM or glycaemic traits. Moreover, we found that women with a high PRS (top quintile) had over threefold (95% CI, 2.30 to 4.09; Pmeta=3.1×10-14) and 71% (95% CI, 1.08 to 2.71; P=0.0220) higher risk for GDM and abnormal glucose tolerance post-pregnancy, respectively, compared to other individuals.
Conclusion
Our results indicate that the genetic architecture of glucose metabolism exhibits both similarities and differences between the pregnant and non-pregnant states. Integrating genetic information can facilitate identification of pregnant women at a higher risk of developing GDM or later diabetes.
4.Identification and Potential Clinical Utility of Common Genetic Variants in Gestational Diabetes among Chinese Pregnant Women
Claudia Ha-ting TAM ; Ying WANG ; Chi Chiu WANG ; Lai Yuk YUEN ; Cadmon King-poo LIM ; Junhong LENG ; Ling WU ; Alex Chi-wai NG ; Yong HOU ; Kit Ying TSOI ; Hui WANG ; Risa OZAKI ; Albert Martin LI ; Qingqing WANG ; Juliana Chung-ngor CHAN ; Yan Chou YE ; Wing Hung TAM ; Xilin YANG ; Ronald Ching-wan MA
Diabetes & Metabolism Journal 2025;49(1):128-143
Background:
The genetic basis for hyperglycaemia in pregnancy remain unclear. This study aimed to uncover the genetic determinants of gestational diabetes mellitus (GDM) and investigate their applications.
Methods:
We performed a meta-analysis of genome-wide association studies (GWAS) for GDM in Chinese women (464 cases and 1,217 controls), followed by de novo replications in an independent Chinese cohort (564 cases and 572 controls) and in silico replication in European (12,332 cases and 131,109 controls) and multi-ethnic populations (5,485 cases and 347,856 controls). A polygenic risk score (PRS) was derived based on the identified variants.
Results:
Using the genome-wide scan and candidate gene approaches, we identified four susceptibility loci for GDM. These included three previously reported loci for GDM and type 2 diabetes mellitus (T2DM) at MTNR1B (rs7945617, odds ratio [OR], 1.64; 95% confidence interval [CI],1.38 to 1.96]), CDKAL1 (rs7754840, OR, 1.33; 95% CI, 1.13 to 1.58), and INS-IGF2-KCNQ1 (rs2237897, OR, 1.48; 95% CI, 1.23 to 1.79), as well as a novel genome-wide significant locus near TBR1-SLC4A10 (rs117781972, OR, 2.05; 95% CI, 1.61 to 2.62; Pmeta=7.6×10-9), which has not been previously reported in GWAS for T2DM or glycaemic traits. Moreover, we found that women with a high PRS (top quintile) had over threefold (95% CI, 2.30 to 4.09; Pmeta=3.1×10-14) and 71% (95% CI, 1.08 to 2.71; P=0.0220) higher risk for GDM and abnormal glucose tolerance post-pregnancy, respectively, compared to other individuals.
Conclusion
Our results indicate that the genetic architecture of glucose metabolism exhibits both similarities and differences between the pregnant and non-pregnant states. Integrating genetic information can facilitate identification of pregnant women at a higher risk of developing GDM or later diabetes.
5.Identification and Potential Clinical Utility of Common Genetic Variants in Gestational Diabetes among Chinese Pregnant Women
Claudia Ha-ting TAM ; Ying WANG ; Chi Chiu WANG ; Lai Yuk YUEN ; Cadmon King-poo LIM ; Junhong LENG ; Ling WU ; Alex Chi-wai NG ; Yong HOU ; Kit Ying TSOI ; Hui WANG ; Risa OZAKI ; Albert Martin LI ; Qingqing WANG ; Juliana Chung-ngor CHAN ; Yan Chou YE ; Wing Hung TAM ; Xilin YANG ; Ronald Ching-wan MA
Diabetes & Metabolism Journal 2025;49(1):128-143
Background:
The genetic basis for hyperglycaemia in pregnancy remain unclear. This study aimed to uncover the genetic determinants of gestational diabetes mellitus (GDM) and investigate their applications.
Methods:
We performed a meta-analysis of genome-wide association studies (GWAS) for GDM in Chinese women (464 cases and 1,217 controls), followed by de novo replications in an independent Chinese cohort (564 cases and 572 controls) and in silico replication in European (12,332 cases and 131,109 controls) and multi-ethnic populations (5,485 cases and 347,856 controls). A polygenic risk score (PRS) was derived based on the identified variants.
Results:
Using the genome-wide scan and candidate gene approaches, we identified four susceptibility loci for GDM. These included three previously reported loci for GDM and type 2 diabetes mellitus (T2DM) at MTNR1B (rs7945617, odds ratio [OR], 1.64; 95% confidence interval [CI],1.38 to 1.96]), CDKAL1 (rs7754840, OR, 1.33; 95% CI, 1.13 to 1.58), and INS-IGF2-KCNQ1 (rs2237897, OR, 1.48; 95% CI, 1.23 to 1.79), as well as a novel genome-wide significant locus near TBR1-SLC4A10 (rs117781972, OR, 2.05; 95% CI, 1.61 to 2.62; Pmeta=7.6×10-9), which has not been previously reported in GWAS for T2DM or glycaemic traits. Moreover, we found that women with a high PRS (top quintile) had over threefold (95% CI, 2.30 to 4.09; Pmeta=3.1×10-14) and 71% (95% CI, 1.08 to 2.71; P=0.0220) higher risk for GDM and abnormal glucose tolerance post-pregnancy, respectively, compared to other individuals.
Conclusion
Our results indicate that the genetic architecture of glucose metabolism exhibits both similarities and differences between the pregnant and non-pregnant states. Integrating genetic information can facilitate identification of pregnant women at a higher risk of developing GDM or later diabetes.
6.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
7.Identification and Potential Clinical Utility of Common Genetic Variants in Gestational Diabetes among Chinese Pregnant Women
Claudia Ha-ting TAM ; Ying WANG ; Chi Chiu WANG ; Lai Yuk YUEN ; Cadmon King-poo LIM ; Junhong LENG ; Ling WU ; Alex Chi-wai NG ; Yong HOU ; Kit Ying TSOI ; Hui WANG ; Risa OZAKI ; Albert Martin LI ; Qingqing WANG ; Juliana Chung-ngor CHAN ; Yan Chou YE ; Wing Hung TAM ; Xilin YANG ; Ronald Ching-wan MA
Diabetes & Metabolism Journal 2025;49(1):128-143
Background:
The genetic basis for hyperglycaemia in pregnancy remain unclear. This study aimed to uncover the genetic determinants of gestational diabetes mellitus (GDM) and investigate their applications.
Methods:
We performed a meta-analysis of genome-wide association studies (GWAS) for GDM in Chinese women (464 cases and 1,217 controls), followed by de novo replications in an independent Chinese cohort (564 cases and 572 controls) and in silico replication in European (12,332 cases and 131,109 controls) and multi-ethnic populations (5,485 cases and 347,856 controls). A polygenic risk score (PRS) was derived based on the identified variants.
Results:
Using the genome-wide scan and candidate gene approaches, we identified four susceptibility loci for GDM. These included three previously reported loci for GDM and type 2 diabetes mellitus (T2DM) at MTNR1B (rs7945617, odds ratio [OR], 1.64; 95% confidence interval [CI],1.38 to 1.96]), CDKAL1 (rs7754840, OR, 1.33; 95% CI, 1.13 to 1.58), and INS-IGF2-KCNQ1 (rs2237897, OR, 1.48; 95% CI, 1.23 to 1.79), as well as a novel genome-wide significant locus near TBR1-SLC4A10 (rs117781972, OR, 2.05; 95% CI, 1.61 to 2.62; Pmeta=7.6×10-9), which has not been previously reported in GWAS for T2DM or glycaemic traits. Moreover, we found that women with a high PRS (top quintile) had over threefold (95% CI, 2.30 to 4.09; Pmeta=3.1×10-14) and 71% (95% CI, 1.08 to 2.71; P=0.0220) higher risk for GDM and abnormal glucose tolerance post-pregnancy, respectively, compared to other individuals.
Conclusion
Our results indicate that the genetic architecture of glucose metabolism exhibits both similarities and differences between the pregnant and non-pregnant states. Integrating genetic information can facilitate identification of pregnant women at a higher risk of developing GDM or later diabetes.
8.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
9.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
10.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.