1.Risk factors for postoperative respiratory failure in patients with esophageal cancer and the prediction model establishment
Bo YANG ; Yue BAI ; Lili LANG ; Qun CAO ; Gongjian ZHU ; Leiyun ZHUANG ; Daqiang SUN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):353-359
Objective To explore the risk factors for postoperative respiratory failure (RF) in patients with esophageal cancer, construct a predictive model based on the least absolute shrinkage and selection operator (LASSO)-logistic regression, and visualize the constructed model. Methods A retrospective analysis was conducted on patients with esophageal cancer who underwent surgical treatment in the Department of Thoracic Surgery, Sun Yat-sen University Cancer Center Gansu Hospital from 2020 to 2023. Patients were divided into a RF group and a non-RF (NRF) group according to whether RF occurred after surgery. Clinical data of the two groups were collected, and LASSO-logistic regression was used to optimize feature selection and construct the predictive model. The model was internally validated by repeated sampling 1000 times based on the Bootstrap method. Results A total of 217 patients were included, among which 24 were in the RF group, including 22 males and 2 females, with an average age of (63.33±9.10) years; 193 were in the NRF group, including 161 males and 32 females, with an average age of (62.14±8.44) years. LASSO-logistic regression analysis showed that the percentage of forced expiratory volume in one second/forced vital capacity (FEV1/FVC) to predicted value (FEV1/FVC%pred) [OR=0.944, 95%CI (0.897, 0.993), P=0.026], postoperative anastomotic fistula [OR=4.106, 95%CI (1.457, 11.575), P=0.008], and postoperative lung infection [OR=3.776, 95%CI (1.373, 10.388), P=0.010] were risk factors for postoperative RF in patients with esophageal cancer. Based on the above risk factors, a predictive model was constructed, with an area under the receiver operating characteristic curve of 0.819 [95%CI (0.737, 0.901)]. The Hosmer-Lemeshow test for the calibration curve showed that the model had good goodness of fit (P=0.527). The decision curve showed that the model had good clinical net benefit when the threshold probability was between 5% and 50%. Conclusion FEV1/FVC%pred, postoperative anastomotic fistula, and postoperative lung infection are risk factors for postoperative RF in patients with esophageal cancer. The predictive model constructed based on LASSO-logistic regression analysis is expected to help medical staff screen high-risk patients for early individualized intervention.
2.Social Work Intervention of Stranded Patients from the Ecosystem Perspective: Based on the Clinical Case Record Analysis of Social Work Department in Shanghai D Hospital
Jie ZHUANG ; Yanyan CHEN ; Bo CHEN ; Yannan PENG ; Yijun SHEN ; Xiaohui WU
Chinese Medical Ethics 2024;35(3):342-349
Based on the service of stranded patients in D Hospital, this study aimed to explore the multiple needs of stranded patients and construct an intervention mode from the ecosystem perspective. Using the method of case study, taking the service of stranded patients in hospital D as an example, 49 case records and verbatim interviews with stakeholders were analyzed. The discharge and resettlement of stranded patients faces multiple obstacles from individuals, families, medical and social systems. This study constructed the social work intervention model from the ecosystem perspective: information collection and needs assessment, empowerment of individual system, reconstruction of family support system, coordination of medical system and linking social support system. The intervention process achieved efficient effects. Social work intervention of stranded patients should pay attention to patients’ psychosocial needs and improve awareness of system difficulties; mobilize the multi-system support network and deliver services in combination with case management method; conduct social advocacy for the breakthrough of law and policy.
3.Sonogenetics and its application in military medicine
Ying-Tan ZHUANG ; Bo-Yu LUO ; Xiao-Dong ZHANG ; Tuo-Yu LIU ; Xin-Yue FAN ; Guo-Hua XIA ; Qing YUAN ; Bin ZHENG ; Yue TENG
Medical Journal of Chinese People's Liberation Army 2024;49(3):360-366
Sonogenetics is an emerging synthetic biology technique that uses sound waves to activate mechanosensitive ion channel proteins on the cell surface to regulate cell behavior and function.Due to the widespread presence of mechanically sensitive ion channel systems in cells and the advantages of non-invasion,strong penetrability,high safety and high accuracy of sonogenetics technology,it has great development potential in basic biomedical research and clinical applications,especially in neuronal regulation,tumor mechanism research,sonodynamic therapy and hearing impairment.This review discusses the basic principles of sonogenetics,the development status of sonogenetics and its application in the prevention and treatment of noise-induced hearing loss,summarizes and analyzes the current challenges and future development direction,thus providing a reference for further research and development of sonogenetics in the field of military medicine.
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Association between Metal(loid)Exposure and Risk of Polycystic Ovary Syndrome Mediated by Anti-Müllerian Hormone among Women Undergoing In Vitro Fertilization and Embryo Transfer
Su SHU ; Ren MENGYUAN ; Feng YANQIU ; Lan CHANGXIN ; Yan LAILAI ; Lu QUN ; Xu JIA ; Han BIN ; Zhuang LILI ; Fang MINGLIANG ; Wang BIN ; Bao HONGCHU ; Pan BO
Biomedical and Environmental Sciences 2024;37(10):1107-1116
Objective To investigate the relationship and potential pathways between metal(loid)exposure and the risk of polycystic ovary syndrome(PCOS)in women of childbearing age. Methods This case-control study included 200 patients with PCOS(cases)and 896 non-PCOS controls with the age of 25-37 years.The concentrations of 29 metal(loid)s in the follicular fluid(FF)and clinical indicators in the serum were measured in all participants.Logistic regression analysis and mediation analysis were conducted to evaluate the associations between metal(loid)exposure and PCOS risk and investigate the possible roles of clinical indicators,respectively. Results Logistic regression analysis revealed an association between high copper levels in FF and increased PCOS risk(highest vs.lowest quartile:adjusted odds ratio=2.94,95%confidence interval:1.83-4.72).A high luteinizing hormone/follicle-stimulating hormone ratio and elevated levels of testosterone and anti-Müllerian hormone(AMH)were strongly associated with increased PCOS risk induced by high copper exposure.The mediation analysis indicated a mediating effect of AMH in the association between copper exposure and PCOS risk. Conclusion Copper may affect PCOS risk through the hypothalamic-pituitary-ovarian axis,mediated by AMH.Copper exposure and internal AMH levels are important indicators for early warning of PCOS development.
8.Quality evaluation for Beidougen Formula Granules
Gui-Yun CAO ; Xue-Song ZHUANG ; Bo NING ; Yong-Qiang LIN ; Dai-Jie WANG ; Wei-Liang CUI ; Hong-Chao LIU ; Xiao-Di DONG ; Meng-Meng HUANG ; Zhao-Qing MENG
Chinese Traditional Patent Medicine 2024;46(3):717-723
AIM To evaluate the quality of Beidougen Formula Granules.METHODS Fifteen batches of standard decoctions and three batches of formula granules were prepared,after which paste rate and contents,transfer rates of magnoflorine,daurisoline,dauricine were determined.HPLC specific chromatograms were established,and cluster analysis was adopted in chemical pattern recognition.RESULTS For three batches of formula granules,the paste rates were 15.1%-16.6%,the contents of magnoflorine,daurisoline,dauricine were 18.93-19.39,9.42-9.60,6.79-6.85 mg/g with the transfer rates of 34.42%-35.25%,43.81%-44.65%,27.27%-27.51%from decoction pieces to formula granules,respectively,and there were seven characteristic peaks in the specific chromatograms with the similarities of more than 0.95,which demonstrated good consistence with those of standard decoctions and accorded with related limit requirements.Fifteen batches of standard decoctions were clustered into two types,and the medicinal materials produced from Jilin,Hebei,Shangdong could be used for the preparation of formula granules.CONCLUSION This reasonable and reliable method can provide references for the quality control and clinical application of Beidougen Formula Granules.
9.Current progress in role of circular RNA in stroke
Di LÜ ; Hengqian DUAN ; Zhujun ZHUANG ; Peng CHEN ; Renhua YANG ; Zhiqiang SHEN ; Bo HE
Chinese Journal of Pathophysiology 2024;40(6):1114-1121
Stroke is a cerebrovascular disease characterized by high rates of disability,recurrence and mortal-ity.It results primarily from cerebrovascular rupture or transient/permanent occlusion.Due to the complex pathological mechanism of stroke and the lack of early-stage biomarkers,effective treatment options remain limited.Circular RNAs(circRNAs)are stable and conserved endogenous long noncoding RNA that regulate the pathological process of stroke,in-cluding oxidative stress,inflammation,apoptosis and autophagy.In addition,the regulatory roles of circRNAs in stroke include ceRNA,DNA methylation and histone modification.This review provides a comprehensive overview of circRNA biogenesis,major functions and characteristics.Furthermore,it presents the latest research findings on circRNAs in the context of stroke pathology,with the aim of providing new insights and potential approaches for unraveling the underlying mechanism,diagnosis and treatment of such diseases.
10.A phase Ⅱ clinical study of the efficacy and safety of antaitasvir phosphate combined with yiqibuvir for the treatment of chronic hepatitis C in adults
Lai WEI ; Hongxin PIAO ; Jinglan JIN ; Shufen YUAN ; Xuan AN ; Jia SHANG ; Wenhua ZHANG ; Jiabao CHANG ; Tong SUN ; Yujuan GUAN ; Bo NING ; Jing ZHU ; Wentao GUO ; Qingwei HE ; Lin LUO ; Yulei ZHUANG ; Hongming XIE ; Yingjun ZHANG
Chinese Journal of Hepatology 2024;32(7):637-642
Objective:To evaluate the efficacy and safety of antaitasvir phosphate 100 mg or 200 mg combined with yiqibuvir for 12 weeks in patients with various genotypes of chronic hepatitis C, without cirrhosis or compensated stage cirrhosis.Methods:Patients with chronic hepatitis C (without cirrhosis or compensated stage cirrhosis) were randomly assigned to the antaitasvir phosphate 100 mg+yiqibuvir 600 mg group (100 mg group) or the antaitasvir phosphate 200 mg+yiqibuvir 600 mg group (200 mg group) in a 1∶1 ratio. The drugs were continuously administered once a day for 12 weeks and observed for 24 weeks after drug withdrawal. The drug safety profile was assessed concurrently with the observation of the sustained virological response (SVR12) in the two patient groups 12 weeks following the drug cessation. The intention-to-treat concept was used to define as closely as possible a full analysis set, including all randomized cases who received the experimental drug at least once. The safety set was collected from all subjects who received the experimental drug at least once (regardless of whether they participated in the randomization group) in this study. All efficacy endpoints and safety profile data were summarized using descriptive statistics. The primary efficacy endpoint was SVR12. The primary analysis was performed on a full analysis set. The frequency and proportion of cases were calculated in the experimental drug group (antaitasvir phosphate capsules combined with yiqibuvir tablets) that achieved "HCV RNA

Result Analysis
Print
Save
E-mail