1.Performance of body mass index, waist circumference and waist-to-height ratio in screening true obesity in children
FANG Qihuan, WANG Yuedong, ZHAO Min, YANG Lili, XI Bo
Chinese Journal of School Health 2025;46(3):421-425
		                        		
		                        			Objective:
		                        			To evaluate the accuracy of body mass index (BMI), waist circumference (WC) and waist-to-height ratio (WHtR) in screening true obesity among children, so as to provide a scientific basis for precise screening and early prevention and control of childhood obesity.
		                        		
		                        			Methods:
		                        			A total of 1 322 children aged 10-15 years old were surveyed by the Huantai Children Cardiovascular Health Cohort in 2021. Fat mass percentage (FMP) and fat mass index (FMI) were measured by bioelectrical impedance analysis, with FMP or FMI values at or above the age and sex-specific 70th percentiles as the criteria for defining true obesity. BMI, WC and WHtR were used to define general obesity and central obesity. The accuracy of these measures in screening for true obesity was evaluated by calculating the missed diagnosis rate, misdiagnosis rate, area under the curve(AUC) for receiver operating characteristic and  Kappa  coefficient.
		                        		
		                        			Results:
		                        			Boys had higher BMI [(21.79±4.56) kg/m 2], WC [(76.41±12.53) cm] and WHtR (0.47±0.07) than girls [(20.83±4.13) kg/m 2, (70.69±10.06) cm, (0.45±0.06)] ( t =4.02, 9.19, 6.63), while boys had lower FMP [(18.29±8.35)%] and FMI [(4.35±2.79) kg/m 2] than girls [(24.87±6.51)%, (5.44±2.53) kg/m 2] ( t =-16.10,-7.42) ( P <0.01). Using FMP as a reference standard, the diagnosis error rates of screening for true obesity based on BMI, WC and WHtR were 12.24%, 2.11% and 2.11%, respectively; the diagnosis error rates were 10.88%, 27.28% and 24.33%; the AUC values were 0.88, 0.85 and 0.87; the  Kappa  coefficients were 0.67, 0.48 and 0.52. Using FMI as a reference standard, rates of BMI, WC and WHtR screening for true obesity were 14.20%, 1.23% and 2.78%; the diagnosis error rates were 4.81%, 20.84% and  18.14 %; the AUC values were 0.90, 0.89 and 0.90; the  Kappa  coefficients were 0.81, 0.64 and 0.67.
		                        		
		                        			Conclusions
		                        			BMI has a higher diagnosis error rate in screening for true obesity in children, while WC and WHtR have higher diagnosis error rates. It is recommended to promote body fat assessment in clinical practice, so as to achieve more accurate prevention and control of chronic diseases.
		                        		
		                        		
		                        		
		                        	
2.Association of joint effect of overweight and obesity with dyslipidemia on left ventricular hypertrophy in children
AN Silian, LIU Ziqi, ZHANG Qian, ZHAO Min, XI Bo
Chinese Journal of School Health 2025;46(4):474-478
		                        		
		                        			Objective:
		                        			To examine the association of joint effect of overweight and obesity with dyslipidemia on left ventricular hypertrophy (LVH) in children, so as to provide scientific evidence for the prevention of early cardiovascular damage in children.
		                        		
		                        			Methods:
		                        			Data were obtained from the second followup crosssectional survey of Huantai Childhood Cardiovascular Health Cohort study in 2021, comprising 1 047 children aged 10-15 years with complete information. Based on overweight and obesity status and dyslipidemia status, all participants were divided into four groups:normal weight with normal lipid levels, normal weight with dyslipidemia, overweight and obesity with normal lipid levels, and overweight and obesity with dyslipidemia. Left ventricular mass index (LVMI) levels and prevalence of LVH across four groups were compared. Multivariate Logistic regression model was used to examine the association of joint effect of overweight and obesity with dyslipidemia on LVH in children.
		                        		
		                        			Results:
		                        			There were significant differences in LVMI levels [(28.66±7.10, 29.63±4.71,31.49±5.86,32.65±4.80)g/m2.7] and prevalence of LVH (4.28%, 12.50%, 22.74%, 31.30%) across four groups (F/χ2=50.76, 90.92, P<0.05). After adjustment for confounding variables such as gender,age,screen time,sleep duration,fruit and vegetable intake,carbonated beverage consumption,physical activity and elevated blood pressure, compared to children with both normal weight and normal lipid levels, the risk of LVH in children with dyslipidemia alone increased (OR=3.27, 95%CI=1.57-6.82,P<0.05). Children with overweight and obesity alone also had a significantly increased risk of LVH (OR=6.33, 95%CI=3.76-10.66), and the highest risk was observed in those with both overweight and obesity with dyslipidemia (OR=9.66, 95%CI=5.35-17.43) (P<0.05).
		                        		
		                        			Conclusions
		                        			The joint effect of overweight and obesity with dyslipidemia is positively correlated with LVH in children. To prevent LVH in children, both overweight and obesity with dyslipidemia should be paid attention to.
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
8.Association between serum alanine transaminase levels and carotid intima media thickness in adolescents
HUANG Sisi, ZHAO Min, SUN Jiahong, XI Bo
Chinese Journal of School Health 2025;46(7):1042-1045
		                        		
		                        			Objective:
		                        			To investigate the relationship between serum alanine transaminase (ALT) and carotid intima media thickness (cIMT) in adolescents, providing evidence for early prevention and control strategies for cardiovascular structural abnormalities in adolescents. 
		                        		
		                        			Methods:
		                        			Data were obtained from the third follow up survey (from October to November 2023) of the "Huantai Children Cardiovascular Health Cohort", including 1 153 healthy adolescents with complete information. Analysis of variance (ANOVA) was used to compare cIMT across different ALT level groups, and multiple linear regression was employed to analyze the relationship between serum ALT levels and cIMT.
		                        		
		                        			Results:
		                        			Significant differences in cIMT were observed among  Q 1,  Q 2, and  Q 3 ALT level groups [(0.56±0.04) (0.57±0.04) (0.59±0.04)mm, respectively;  F=3.61, P <0.01]. After adjusting for covariates, multiple linear regression revealed a positive correlation between ALT levels and cIMT ( β=0.18, P <0.01). Gender subgroup analysis showed similar results in males ( β=0.19, P <0.01), but no statistically significant association was found in females ( β=0.07,  P = 0.54). 
		                        		
		                        			Conclusions
		                        			Elevated serum ALT levels are associated with an increased risk of vascular structural damage in adolescents, especially in boys. Early detection and control of abnormal serum ALT levels can help to reduce early vascular structural damage and further reduce the risk of adverse cardiovascular events.
		                        		
		                        		
		                        		
		                        	
9.Associations between weekday-weekend screen time and subjective sleep quality among adolescents
CAO Runze, ZHAO Min, WANG Mingming, XI Bo
Chinese Journal of School Health 2025;46(8):1170-1174
		                        		
		                        			Objective:
		                        			To explore the association between the joint association of screen time on weekdays and weekends with self rated sleep quality among adolescents, providing scientific basis for improving adolescent sleep health. 
		                        		
		                        			Methods:
		                        			Using data from "Huantai Children s Cardiovascular Health Follow up Cohort" survey conducted during November to December 2023, a total of 1 197 adolescents aged 12-17 years with complete demographic characteristics, physical measurements, and questionnaire data were included. The dose response relationship between screen time and sleep quality was evaluated by restrictive cubic splines (RCS). Based on screen time on weekdays and weekends (normal: < 2 h/d; excessive: ≥ 2 h/d), adolescents were categorized into 4 groups. Multivariate Logistic regression models were used to analyze the association between the combined effect of screen time on weekdays and weekends and sleep quality.
		                        		
		                        			Results:
		                        			The RCS analysis results showed that there was a linear dose response relationship between average daily screen time and poor sleep quality in adolescents (non linear  P >0.05). The results of multiple Logistic regression analysis showed that adjusting for potential covariates,compared with adolescents having normal screen time on both weekdays and weekends, those with excessive screen time on both weekdays and weekends had increased risk of poor sleep quality ( OR=2.51, 95%CI=1.33-4.62, P <0.01). Sex stratified analysis revealed that girls with excessive screen time on both weekdays and weekends had increased odds of poor sleep quality ( OR=3.03, 95%CI=1.23-7.14, P =0.01), compared to girls who had normal screen time on both weekdays and weekends. 
		                        		
		                        			Conclusions
		                        			A linear dose response relationship exists between daily screen time and poor sleep quality in adolescents. Excessive screen time on both weekdays and weekends is positively associated with poor sleep quality, particularly more pronounced among female adolescents.
		                        		
		                        		
		                        		
		                        	
10.Association of serum alanine aminotransferase level with left ventricular hypertrophy in adolescents
JIA Peng, ZHAO Min, SUN Jiahong, XI Bo
Chinese Journal of School Health 2025;46(8):1180-1184
		                        		
		                        			Objective:
		                        			To investigate the association of serum alanine aminotransferase (ALT) with left ventricular hypertrophy (LVH) in adolescents, and to provide scientific evidence for the early screening and intervention strategy of cardiac structure damage. 
		                        		
		                        			Methods:
		                        			Data were obtained from the third follow up survey (October 2023) of the "Huantai Childhood Cardiovascular Health Cohort Study", including 1 156 healthy adolescents aged 12-17 with complete information. The sample population was stratified into low ( Q 1 group), medium ( Q 2 group), and high ( Q 3 group) ALT levels based on tertiles within the same gender and age groups. Inter group comparisons were conducted using analysis of variance and trend test. A multivariate Logistic regression model was used to analyze the association between ALT levels and LVH, and stratified analyses were performed by gender and age groups.
		                        		
		                        			Results:
		                        			With the increase of ALT quantile level, the detection rate of LVH showed an increasing trend ( Q 1: 3.7%;  Q 2: 10.6%;  Q 3: 16.7%,  Z= 5.89 , P <0.01). After adjusting for potential covariates, compared with the ALT group ( Q 1), the group ( Q 3) increased the risk of developing LVH in adolescents ( OR=2.09, 95%CI =1.21-4.12). Stratified analyses by age and sex showed a significant association only in boys and younger individuals aged 12 to 14 years [ OR  (95% CI ) were 2.64(1.04-7.67) and 3.24( 1.35 -9.06), both  P <0.05)]. 
		                        		
		                        			Conclusion
		                        			Elevated serum ALT levels are associated with an increased risk of LVH in adolescents, and early detection and control of abnormal liver enzyme levels can help reduce early vascular structural damage and prevent adverse cardiovascular events.
		                        		
		                        		
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail