1.Status and serological features of occult hepatitis B virus infection among blood donors in Xuzhou
Jiahui LIU ; Bei WANG ; Liling ZHOU
Chinese Journal of Blood Transfusion 2025;38(3):402-407
[Objective] To explore the current status, influencing factors, and serological characteristics of occult hepatitis B virus infection (OBI) among blood donors in Xuzhou, so as to provide data support for improving blood safety screening strategies. [Methods] Blood samples from blood donors from January 2019 to December 2023 in Xuzhou were tested using enzyme-linked immunosorbent assay (ELISA) for serological markers and transaminase levels. Qualified samples were then subjected to nucleic acid testing (NAT). Statistical analysis was performed on the gender, age, education level, and occupation of HBV-infected donors. Logistic regression analysis was used to identify risk factors and epidemiological trends in OBI donors. Chemiluminescence immunoassay was used to quantify the levels of anti-HBs, HBeAg, anti-HBe, and anti-HBc in OBI donors and eligible donors (control group). [Results] Among the 545 292 blood donors, there were 388 OBI donors were identified, with a positive rate of 0.07%. Multivariate logistic regression analysis revealed that male gender, age >45 years, education below college level, and occupation as a farmer were associated risk factors for OBI infection. Among the 388 OBI donors, the predominant serological patterns were anti-HBs and anti-HBc positive (48.71%), anti-HBs, anti-HBe, and anti-HBc positive (16.75%), and anti-HBc alone positive (16.49%). In contrast, the most common patterns among eligible donors were anti-HBs alone positive (46.96%) and serologically negative (26.52%). Anti-HBs levels in OBI donors were significantly lower than those in eligible donors across all patterns (P<0.05). For donors positive for anti-HBc, the distribution of anti-HBs levels in OBI donors was predominantly <100 IU/L, significantly lower than that in eligible donors (P<0.05), while and the proportion of eligible donors with anti-HBs levels >1 000 IU/L was higher than that in OBI donors (P<0.05). [Conclusion] There is a certain proportion of OBI infections among blood donors in Xuzhou, with an overall declining trend. NAT contributes to improved detection rates of HBV infections. The epidemiological distribution of OBI donors in terms of gender, age, education, and occupation differs from that of eligible donors, and there are also differences in serological characteristics between the two groups.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.The value of high-throughput sequencing data reanalysis in identifying ERBB2 amplification in colorectal cancer patients
Min-Na SHEN ; Li ZHANG ; Xin-Ning CHEN ; Fei HUANG ; Chao-Gang BAI ; Li-Meng CHEN ; Hai-Xiang PENG ; Yan ZHOU ; Bei-Li WANG ; Bai-Shen PAN ; Wei GUO
Fudan University Journal of Medical Sciences 2024;51(2):166-171
Objective To evaluate the value of high-throughput sequencing(HTS)data reanalysis that does not include ERBB2 copy number variation(CNV)analysis,in identifying ERBB2 amplification in patients with colorectal cancer.Methods The HTS data of 252 cases of colorectal cancer diagnosed by pathological biopsy who received peripheral blood cfDNA HTS detection samples were retrospectively analyzed.According to the HTS data of ERBB2 non-amplified samples judged by immunohistochemistry(IHC)and/or fluorescence in situ hybridization(FISH),the number of chromosome 17(Chr17)reads in the total number of reads was calculated the range of the ratio was initially determined as the threshold for prompting ERBB2 amplification.Suspected positive samples were screened according to thresholds and verified by digital PCR,IHC and FISH.Results The proportion of the number of Chr17 reads accounts for the number of total reads in the 89 cases of ERBB2 non-amplified samples determined by IHC and/or FISH ranged from 0.188 to 0.299(0.239±0.192).Using 0.298(1.25 times the mean)as the threshold indicating ERBB2 amplification,the data of 163 samples were analyzed,of which 7 cases were suspected to be positive,and the ratio ranged from 0.302 to 0.853.Among them,5 cases were determined to be positive by IHC and/or FISH,and 6 cases were confirmed to be positive by digital PCR.The ratio of the number of Chr17 reads to the number of total reads was positively correlated with the ratio of ERBB2/EIF2C1,and the correlation was good(r2=0.909).Conclusion The high-throughput sequencing data that does not cover the ERBB2 CNV analysis has a certain hint value for ERBB2 amplification in patients with colorectal cancer.
8.Structure of The BLUF Protein TePixD Y8F Mutant
Rui-Xing HU ; Ya-Lin ZHOU ; Lin LIN ; Bei DING ; Qing LU
Progress in Biochemistry and Biophysics 2024;51(2):459-467
ObjectiveTePixD (Tll0078) is a blue light-using flavin (BLUF) photoreceptor protein from Thermosynechococcus elongatus BP-1. TePixD protein has a conserved Tyr8-Gln50-Met93 triad around the FAD pocket to mediate the proton-coupled electron transfer (PCET) process. But the detailed light response mechanism needs further study. We aimed to elucidate the structure and biochemical properties of TePixD mutants at key light response sites to analyze the light response process of TePixD. MethodsWe employed X-ray crystallography to resolve the crystal structure of the TePixD Y8F mutant. The side chain of Tyr8 is involved in PCET while Phe8 in mutation loses the function due to the loss of its hydroxyl group. We compared the structure of TePixD Y8F mutation to TePixD wild type (WT) and its homology protein SyPixD Y8F. Using multi-angle light scattering (MALS), we analyzed the oligomerization of multiple TePixD mutations (Y8F, Q50L, W91F, Y8F/W91F, and Q50L/W91F), focusing specifically on mutational sites that are critical residues for the protein’s photo response to dark and light conditions. ResultsWe resolved the crystal structure of TePixD Y8F mutant at a resolution of 2.54 Å and found that it shares a similar overall structure with the TePixD WT but exhibits significant differences from the SyPixD Y8F structure. Biochemical analysis revealed differences in molecular mass and elution profiles between the TePixD mutants and the WT under dark and light conditions, indicating the perturbation on the light-induced conformational change by the mutants. ConclusionOur structure determination and biochemical analyses will add information to reveal the light response mechanism of BLUF proteins.
9.Efficacy and safety of artificial liver support therapy with a selective plasma separator in low-platelet count patients with acute-on-chronic liver failure
Shoujuan LI ; Li WANG ; Ming ZHOU ; Bei WU ; Lei WANG ; Meng DUAN ; Hongfan LIAO ; Ruiqing HU ; Zhaoxia HU ; Li ZHU ; Juan HU
Journal of Clinical Hepatology 2024;40(6):1191-1195
Objective To investigate the efficacy and safety of artificial liver support therapy with an Evanure-4A selective membrane plasma separator and its influence on platelet count in the treatment of patients with acute-on-chronic liver failure(ACLF)patients with different platelet counts.Methods A total of 302 patients with ACLF who were hospitalized in Department of Hepatology,Chengdu Public Health Clinical Medical Center,from January 2021 to May 2023,were enrolled,and according to the platelet count(PLT),they were divided into group A(25×109/L—50×109/L)with 101 patients,group B(51×109/L—80×109/L)with 98 patients,and group C(81×109/L—100×109/L)with 103 patients.In addition to medical treatment,all patients received different modes of artificial liver support therapy based on their conditions,including plasma perfusion combined with plasma exchange,double plasma molecular adsorption combined with plasma exchange,and bilirubin system adsorption combined with plasma exchange.The paired t-test was used for comparison of continuous data before and after treatment in each group;an analysis of variance was used for comparison between multiple groups,and the SNK-q test was used for further comparison between two groups;the chi-square test was used for comparison of categorical data between multiple groups.Results Of all 302 patients,268(88.74%)achieved varying degrees of improvement in clinical symptoms after artificial liver support therapy.After treatment,all three groups had varying degrees of reductions in alanine aminotransferase(t=14.755,21.614,and 15.965,all P<0.001),aspartate aminotransferase(t=11.491,19.301,and 13.919,all P<0.001),total bilirubin(t=19.182,17.486,and 21.75,all P<0.001),and international normalized ratio(INR)(t=3.497,3.327,and 4.358,all P<0.05).After artificial liver support therapy with an Evanure-4A selective membrane plasma separator,PLT in group A decreased from(37.73±6.27)×109/L before treatment to(36.59±7.96)×109/L after treatment,PLT in group B decreased from(66.97±7.64)×109/L before treatment to(62.59±7.37)×109/L after treatment,and PLT in group C decreased from(93.82±5.38)×109/L before treatment to(85.99±12.49)×109/L after treatment;groups B and C had significant reductions in PLT after treatment(t=12.993 and 8.240,both P<0.001),but there was no significant difference in group A(P>0.05).There was no significant difference in the incidence rate of adverse reactions during artificial liver support therapy between the three groups(P>0.05).Conclusion Artificial liver support therapy can improve liver function and INR in patients with ACLF.The use of Evaure-4A selective membrane plasma separator during artificial liver support therapy has little influence on platelets,and it is safe in the treatment of ACLF patients with a significantly lower level of platelets.
10.Relationship between serum miR-410-3p expression and knee soft tissue lesions in patients with rheumatoid arthritis
Hui RAO ; Sheng-Zhi JIANG ; Yu-Bei FAN ; Yu-Qing ZHOU ; Li-Hua ZHANG
Journal of Regional Anatomy and Operative Surgery 2024;33(2):137-140
Objective To explore the expression of serum miR-410-3p in patients with rheumatoid arthritis(RA)and its relationship with knee soft tissue lesions.Methods A total of 89 RA patients admitted to our hospital were selected and divided into the active group(42 cases)and the remission group(47 cases)according to disease activity score in 28 joints(DAS28).In addition,52 healthy volunteers underwent physical examination during the same period in our hospital were selected as the healthy group.The expression level of serum miR-410-3p was detected by RT-PCR,the lesions of knee soft tissue was examined by ultrasound,and the relationship between the expression of serum miR-410-3p and knee soft tissue lesions was analyzed by Pearson.Results The expression levels of serum miR-410-3p of patients in the active group and the remission group were lower than that in the healthy group(P<0.05),and the expression level of serum miR-410-3p of patients in the active group was lower than that in the remission group(P<0.05).The cartilage thicknesses of medial and lateral ankle of patients in the active group and the remission group were smaller than those in the healthy group(P<0.05),and the above indexes in the active group were smaller than those in the remission group(P<0.05).The depths of suprapatellar bursa fluid and synovial thicknesses of patients in the active group and the remission group were greater than those in the healthy group(P<0.05),and the depth of suprapatellar bursa fluid and synovial thickness of patients in the active group were greater than those in the remission group(P<0.05).The level of serum miR-410-3p in RA patients was positively correlated with the depth of suprapatellar bursa fluid and synovial thickness(P<0.05),and negatively correlated with the cartilage thicknesses of medial and lateral ankle(P<0.05).Conclusion Serum miR-410-3p expression level in RA patients is decreased,which was closely related to knee soft tissue lesions,detecting the changes of serum miR-410-3p level may provide a reference for the evaluation of knee soft tissue lesions.

Result Analysis
Print
Save
E-mail