1.The expression of membrane type 1 matrix metalloproteinase in the esophageal carcinoma tissues and its clinical significance
Xuguang RAO ; Limin MA ; Bailiang CHEN ; Wei YANG ; Mingke DUAN
Chinese Journal of Postgraduates of Medicine 2008;31(11):25-28
Objective To investigate the expression of membrane type 1 matrix metalloproteinase(MT1-MMP) in the esophageal carcinoma tissues and in normal periearcinomatous tissues and its clinical significance. Methods Immunohistochemistry was used to study the expression of MT1-MMP in esophageal carcinoma tissues and normal tissues in distance for 5-7 em from tumor. Results Among 54esophageal carcinoma specimens, the positive expression rate of MT1-MMP was 87.0%, while all of themwere expressed a small quantity in normal esophageal epithelial tissues, the expression in the esophageal carcinoma tissues was significantly higher than those in normal esophageal epithelial tissues (P < 0.01 ).The degree of MT1-MMP expressions was associated with the depth of tumor invasion (P < 0.01 ), the invasion of the lymph nodes(P < 0.01 ) and the relapse and/or metastasis of the tumors for three years after surgery(P <0.01 ), and was also related to differentiation of tumor cells (P < 0.01 ). Conclusions The expression of MT1-MMP in the esophageal carcinoma tissues is well associated with the depth of tumor invasion, the invasion of the lymph nodes, the differentiation of tumor cells and relapse and/or metastasis of the tumors for three years after surgery. MT1-MMP plays an important rote in the invasion and metastasis in the patients with esophageal carcinoma.
2.Determination of the Content of Meropenem and Observation of the Stability of Meropenem in Mixing With Infusion Fluids
Xiaoming CHEN ; Bailiang PAN ; Ruiting ZHAO
China Pharmacy 1991;0(05):-
OBJECTIVE:To establish a HPLC method for determining the content of Meropenem and to observe the stability of Meropenem in mixing with 5%GS,GNS and NS.METHODS:The conditions of HPLC were:column,Nova-Pak C18;mobile phase,acetonitrile-0.05mol KH2PO4(4∶96);flow rate,1.0ml/min;detection wavelength,300nm.After Meropenem mixing with 5%GS,GNS and NS,the changes of external apperance were observed in room temperature,the content was detected with HPLC and the pH and insoluble particles were determined.RESULTS:The calibration curve was in good linearity in the range of 12.5~250?g/ml(r=0.9 999)and the recovery was 99.7% with RSD=1.1%.CONCLUSION:This detection method is effective,rapid and accurate.Meropenem is stable in infusion fluids for 4 hr.
Result Analysis
Print
Save
E-mail