1.Genetic characteristic analysis of slight-to-moderate sensorineural hearing loss in children.
Rui ZHOU ; Jing GUAN ; Qiuju WANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2024;38(1):18-22
Objective:To analyze genetic factors and phenotype characteristics in pediatric population with slight-to-moderate sensorineural hearing loss. Methods:Children with slight-to-moderate sensorineural hearing loss of and their parents, enrolled from the Chinese Deafness Genome Project, were studied. Hearing levels were assessed using pure tone audiometry, behavioral audiometry, auditory steady state response(ASSR), auditory brainstem response(ABR) thresholds, and deformed partial otoacoustic emission(DPOAE). Classification of hearing loss is according to the 2022 American College of Medical Genetics and Genomics(ACMG) Clinical Practice Guidelines for Hearing Loss. Whole exome sequencing(WES) and deafness gene Panel testing were performed on peripheral venous blood from probands and validations were performed on their parents by Sanger sequencing. Results:All 134 patients had childhood onset, exhibiting bilateral symmetrical slight-to-moderate sensorineural hearing loss, as indicated by audiological examinations. Of the 134 patients, 29(21.6%) had a family history of hearing loss, and the rest were sporadic patients. Genetic causative genes were identified in 66(49.3%) patients. A total of 11 causative genes were detected, of which GJB2 was causative in 34 cases(51.5%), STRC in 10 cases(15.1%), MPZL2 gene in six cases(9.1%), and USH2A in five cases(7.6%).The most common gene detected in slight-to-moderate hearing loss was GJB2, with c. 109G>A homozygous mutation found in 16 cases(47.1%) and c. 109G>A compound heterozygous mutation in 9 cases(26.5%). Conclusion:This study provides a crucial genetic theory reference for early screening and detection of mild to moderate hearing loss in children, highlighting the predominance of recessive inheritance and the significance of gene like GJB2, STRC, MPZL2, USH2A.
Humans
;
Child
;
Connexins/genetics*
;
Connexin 26/genetics*
;
Hearing Loss, Sensorineural/diagnosis*
;
Mutation
;
Usher Syndromes
;
Hearing Loss, Bilateral
;
Audiometry, Pure-Tone
;
Intercellular Signaling Peptides and Proteins
2.A case of sudden hearing loss combined with familial hyperlipidemia.
Hui ZHONG ; Xiaonan WU ; Jing GUAN ; Dayong WANG ; Qiuju WANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2024;38(1):70-72
Hyperlipidemia is characterized by elevated levels of blood lipids. The clinical manifestations are mainly atherosclerosis caused by the deposition of lipids in the vascular endothelium. The link between abnormal lipid metabolism and sudden hearing loss remains unclear. This article presents a case study of sudden hearing loss accompanied by familial hyperlipidemia. Pure tone audiometry indicated intermediate frequency hearing loss in one ear. Laboratory tests showed abnormal lipid metabolism, and genetic examination identified a heterozygous mutation in theAPOA5 gene. Diagnosis: Sudden hearing loss; hypercholesterolemia. The patient responded well to pharmacological treatment. This paper aims to analyze and discuss thepotential connection between abnormal lipid metabolism and sudden hearing loss.
Humans
;
Audiometry, Pure-Tone
;
Deafness/complications*
;
Hearing Loss, Sensorineural/diagnosis*
;
Hearing Loss, Sudden/diagnosis*
;
Hyperlipidemias/complications*
;
Lipids
3.Comparative study of surgical effects on patients with mixed deafness and otosclerosis with different air bone conduction differences.
Shuai ZHANG ; Chu Feng HE ; Xin Zhang CAI ; Lu JIANG ; Xue Wen WU ; Yi JIN ; Ling Yun MEI
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(7):666-671
Objective: To analyze the surgical efficacy of patients with mixed hearing loss and otosclerosis with different air bone gap (ABG) before surgery, and to provide reference for the prognosis evaluation of otosclerosis surgery. Methods: The clinical data of 108 cases(116 ears) of otosclerosis who had undergone stapes fenestration technique artificial stapes implantation in Xiangya Hospital of Central South University from November 2013 to May 2020 and had mixed hearing loss before surgery were collected, including 71 women(76 ears)and 37 men (40 ears), with an average age of 38.5 years. According to preoperative pure tone audiometry ABG, they were divided into three groups: group S, 15 dB≤ABG<31 dB, a total of 39 ears; group M, 31 dB≤ABG<46 dB, a total of 58 ears; and group L, ABG≥46 dB, 19 ears in total. The hearing outcomes of three groups of patients at 6-12 months after surgery were compared and analyzed using SPSS 24.0 statistical software. Results: A total of 3 patients (group S: 2 cases; group L: 1 case) experienced severe sensorineural hearing loss after surgery and were not included in the statistical analysis. After surgery, the pure tone hearing threshold of patients with otosclerosis in each group was significantly improved compared to before surgery, with an average air conduction threshold improvement of(21.6±13.4) dB. The difference between before and after surgery was statistically significant(t=17.13, P<0.01). The average bone conduction threshold improved by(3.7±7.6) dB, and the difference was statistically significant before and after surgery(t=5.20, P<0.01). The postoperative ABG was(18.3±9.3) dB, which was significantly reduced compared to preoperative(36.2±8.6)dB. Among the three groups of patients, the L group had the highest improvement in air conduction threshold[(29.9±10.8)dB], while the S group had the lowest improvement[(15.7±11.4)dB]. There was no statistically significant difference in post operative pure tone hearing thresholds between the three groups(P>0.05). The postoperative ABG in group S was the smallest[(16.5±9.0)dB], while in group L, the postoperative ABG was the largest[(20.5±10.0)dB]. Compared with group S, group M and group L still had a large residual ABG at 2 000 Hz after surgery. The bone conduction threshold of both S and M groups improved to some extent after surgery compared to before (P<0.01). Conclusions: Surgery can benefit patients with mixed hearing loss and otosclerosis with different preoperative ABG. Patients with small preoperative ABG have better surgical results and ideal ABG closure at all frequencies after surgery. Patients with large preoperative ABG can significantly increase the gas conduction threshold during surgery, but certain frequencies of ABG may still be left behind after surgery. The improvement effect of surgery on bone conduction threshold is not significant. Patients should be informed of treatment methods such as hearing aids based on their actual situation for selection.
Male
;
Humans
;
Female
;
Adult
;
Bone Conduction
;
Otosclerosis/surgery*
;
Hearing Loss, Mixed Conductive-Sensorineural/surgery*
;
Stapes Surgery/methods*
;
Treatment Outcome
;
Auditory Threshold
;
Hearing
;
Audiometry, Pure-Tone
;
Deafness
;
Retrospective Studies
4.Association of glycemic index using HbA1c and sensorineural hearing loss in diabetes mellitus type 2 patients: A systematic review and meta-analysis
Mark Randell R. Quines, MD ; Cristopher Ed C. Gloria, MD
Philippine Journal of Otolaryngology Head and Neck Surgery 2023;38(1):10-16
Objective:
To systematically review the available evidence on the association of HBA1c levels and development of sensorineural hearing loss and to quantitatively analyze the available data on HBA1c levels in patients with type 2 diabetes mellitus and sensorineural hearing loss to determine an HbA1c level that may be associated with the risk of having sensorineural hearing loss.
Methods:
Design: Systematic Review and Meta-analysis
Eligibility Criteria: Cross-sectional studies, or cohort studies which were limited to English language that investigated the correlation of glycemic index using HBA1c and sensorineural hearing loss among adult type 2 diabetic patients which were done from January 2010 to December 2021. Studies with no published outcome, incomplete data or that were ongoing as of August 1, 2022 were also excluded.
Information Sources: MEDLINE (through PubMed), Cochrane Library, Scopus, Embase (through OVID@journal), Directory of Open Access Journals (DOAJ), Google Scholar and HERDIN Plus
Risk of Bias: Risk of Bias was assessed using the Guidelines for Cochrane Collaboration
Synthesis of Results: Results were presented using forest plots for representation.
Results:
A total of 8 studies were reviewed with 2,103 participants in all. Six articles compared hearing loss incidence between diabetic and non-diabetic patients. Overall, there were a total of 881 diabetic patients and 1222 non-diabetic patients. There was a significantly lower incidence of sensorineural hearing loss in non-diabetic patients with a risk ratio of 1.89, 95% CI [1.65, 2.16]. Three articles compared the HbA1c levels of diabetic patients with or without sensorineural hearing loss. Diabetic patients without sensorineural hearing loss had significantly lower HbA1c levels compared to those with sensorineural hearing loss with mean difference of 1.04, 95%CI [0.82, 1.25].
Conclusion
In conclusion, this meta-analysis showed a higher prevalence rate of sensorineural hearing loss among patients with diabetes mellitus compared to non-diabetic patients. Moreover, poor glycemic control among diabetic patients with a glycemic index based on HbA1c of more than 8.3 (6.97-9.6) is associated with sensorineural hearing loss.
diabetes mellitus
;
glycemic index
;
sensorineural hearing loss
;
pure tone audiometry
;
deafness
5.Application Progress of Objective Audiological Detection Techniques in Forensic Clinical Medicine.
Fei FAN ; Juan WU ; Zhen-Hua DENG
Journal of Forensic Medicine 2023;39(4):360-366
The qualitative, quantitative, and localization analysis of hearing loss is one of the important contents of forensic clinical research and identification. Pure-tone audiometry is the "gold standard" for hearing loss assessment, but it is affected by the subjective cooperation of the assessed person. Due to the complexity of the auditory pathway and the diversity of hearing loss, the assessment of hearing loss requires the combination of various subjective and objective audiometric techniques, along with comprehensive evaluation based on the case situation, clinical symptoms, and other examinations to ensure the scientificity, accuracy and reliability of forensic hearing impairment assessment. Objective audiometry includes acoustic impedance, otoacoustic emission, and various auditory evoked potentials. The frequency-specific auditory brainstem response (ABR), 40 Hz auditory event related potential, and auditory steady-state response are commonly used for objective hearing threshold assessment. The combined application of acoustic impedance, otoacoustic emission and ABR can be used to locate hearing loss and determine whether it is located in the middle ear, cochlea, or posterior cochlea. This article reviews the application value of objective audiometry techniques in hearing threshold assessment and hearing loss localization, aiming to provide reference for forensic identification of hearing loss.
Humans
;
Reproducibility of Results
;
Auditory Threshold/physiology*
;
Evoked Potentials, Auditory, Brain Stem/physiology*
;
Hearing Loss/diagnosis*
;
Audiometry, Pure-Tone/methods*
;
Clinical Medicine
6.Development of High-performance Hearing Test System.
Li CAO ; Yong LI ; Haiping HUANG ; Zhenjin DENG ; Bitao WU ; Pengju LIU ; Zaiming PENG
Chinese Journal of Medical Instrumentation 2022;46(2):152-155
This paper analyzes the shortcomings of the existing pure tone audiometers, and proposes a system to realize pure tone audiometry and speech audiometry with a new DSP processor. The pure tone test signal produced by the system has accurate frequency, high signal-to-noise ratio, and small harmonic distortion. The noise generator that comes with DSP adds a band-pass filter to realize the generation of narrow-band noise. At the same time, due to the modular structure of software design, the system has good ease of use and scalability. The test results show that the hearing test system has excellent performance and can be better used in hearing medical diagnosis.
Audiometry, Pure-Tone/methods*
;
Hearing
;
Noise
;
Signal-To-Noise Ratio
8.Comparison of ASSR, ABR and 40 Hz AERP Response Thresholds at Different Frequencies and Their Forensic Applications.
Xin-Yuan ZHANG ; Fang-Liang LUO ; Long-Long CHENG ; Yan-He XIONG ; Ji-Hui LIU
Journal of Forensic Medicine 2021;37(6):813-816
OBJECTIVES:
To explore the relationship between the frequency characteristics and response threshold of auditory steady-state response (ASSR), auditory brainstem response (ABR) and 40 Hz auditory event related potential (40 Hz AERP), and their application values in forensic medicine.
METHODS:
Thirty volunteers with normal hearing (60 ears) were selected to perform pure tone audiometry (PTA) threshold and ASSR, ABR and 40 Hz AERP response threshold tests in the standard sound insulation shielding room, and the results were statistically analyzed by SPSS 22.0 software.
RESULTS:
At 0.5 kHz and 1.0 kHz frequencies, the correlation between 40 Hz AERP response threshold and PTA threshold was good, which was better than that of ASSR and ABR response threshold. At 2.0 kHz and 4.0 kHz frequencies, the correlation between ASSR and ABR response thresholds and PTA threshold was good, which was better than that of 40 Hz AERP response threshold.
CONCLUSIONS
To evaluate the hearing at 0.5 kHz and 1.0 kHz frequencies, it is recommended to use 40 Hz AERP and ASSR to comprehensively assess the PTA threshold of the subjects. To evaluate the hearing at 2.0 kHz and 4.0 kHz frequencies, ABR and ASSR are recommended to assess the PTA threshold of subjects comprehensively. The combination of ASSR, ABR and 40 Hz AERP can improve the accuracy of hearing function evaluation.
Acoustic Stimulation/methods*
;
Audiometry, Evoked Response
;
Audiometry, Pure-Tone
;
Auditory Threshold/physiology*
;
Evoked Potentials, Auditory, Brain Stem/physiology*
;
Forensic Medicine
;
Hearing/physiology*
;
Humans
9.A descriptive cross-sectional study on the prevalence of noise-induced hearing loss among traffic enforcers in selected major roads in Quezon City
Joanna Pauline C. Kwan Tiu ; Mariama Mae B. Lacsamana ; Christine G. Lacdo-o ; Julina Maria P. Katigbak ; Jaira Y. Evangelista ; Darwin A. Espiritu ; Annjanette V. Fabro ; Jerwin Caesar A. Estacio ; Princess Joy D. Estrella ; Jeremias Anton M. Fabricante ; Arvin Jon C. Fariñ ; as ; Ma. Penafrancia L. Adversario ; Elmo R. Lago ; Jean Roschelle M. Alonso
Health Sciences Journal 2020;9(1):19-25
INTRODUCTION:
Noise-induced hearing loss (NIHL) attributed to occupational noise exposure is one of the most common causes of permanent hearing impairment. In the Philippines, road traffic remains the biggest source of noise. The authors aimed to determine the prevalence of NIHL among traffic enforcers in Quezon City and quantify their occupational noise exposure levels.
METHODS:
Traffic enforcers were recruited via convenience sampling and screened using a questionnaire and otoscopic examination. Participants underwent pure tone audiometry and those found to have hearing loss were classified as “indicative” or “suspected” NIHL. Audiometric measurements of noise levels in areas where the traffic enforcers were assigned were taken using a calibrated smartphone application.
RESULTS:
“Indicative of NIHL” was highest in the 41 to 50-year age group and “suspected NIHL” was highest in the 31 to 40-year age group. “Indicative of NIHL” was highest among those working for 1 to 5 and 11 to 15 years in the right ear (25%) and 11 to 15 years in the left ear (30%). “Suspected NIHL” was highest among those working for 6 to 10 years. The average noise levels from the different areas measured at different times ranged from 79.0 to 82.5 dB.
CONCLUSION
“Indicative of NIHL” is more prevalent in the older age group while “suspected NIHL” is more prevalent in the middle age group. The prevalence of “indicative of NIHL” is highest among those in service for 1 to 5 and 11 to 15 years while “suspected NIHL” is highest among those in the service for 6 to 10 years. The average noise level measurements were within the safe values suggested by WHO.
Audiometry, Pure-Tone
;
Hearing Loss, Noise-Induced
;
Noise, Occupational
10.Frequency Characteristics of AEPs in Normal Young Adults and Comparison of Their Response Threshold and Pure Tone Audiometry Threshold.
Long Long CHENG ; Fang Liang LUO ; Yan He XIONG ; Fu Quan JIA ; Peng TANG ; Wei LIU ; Biao ZHANG ; Ji Hui LIU ; Hai Xia WANG
Journal of Forensic Medicine 2020;36(3):305-310
Objective The tests of three types of auditory evoked potentials (AEPs) were performed on normal young adults, to understand the frequency characteristics of different testing methods and the relationship between response threshold and pure tone audiometry threshold of different methods, and to discuss the forensic value of 3 types of AEPs to evaluate hearing function. Methods Twenty normal young adults were selected, their standard pure tone audiometry threshold, short-term pure tone audiometry threshold and the response threshold of 3 types of AEPs (tone burst-auditory brainstem response, 40 Hz auditory event-related potential and slow vertex response) at 0.5 kHz, 1.0 kHz, 2.0 kHz and 4.0 kHz were recorded. The relationship between the response threshold and standard pure tone audiometry threshold, short-term pure tone audiometry threshold of 3 types of AEPs at different frequencies as well as the differences between different types of AEPs were analyzed. Results The short-term pure tone audiometry threshold was higher than the standard pure tone audiometry threshold at each frequency. The response threshold and standard pure tone audiometry threshold of the 3 types of AEPs all had a certain correlation, and the response threshold of the 3 types of AEPs was higher than short-term pure tone audiometry threshold and standard pure tone audiometry threshold at each frequency. The differences in the differences between the response threshold and standard pure tone audiometry threshold of the 3 types of AEPs at different frequencies had statistical significance. Linear regression mathematical models were established to infer the standard pure tone audiometry threshold (hearing level) from response threshold (sound pressure level) of 3 types of AEPs of normal young adults. Conclusion When using response threshold of different types of AEPs to estimate pure tone audiometry threshold, conversion and correction are needed. Combined use of different types of AEPs could improve the accuracy of hearing function evaluation.
Audiometry, Evoked Response
;
Audiometry, Pure-Tone
;
Auditory Threshold
;
Evoked Potentials, Auditory
;
Evoked Potentials, Auditory, Brain Stem
;
Hearing
;
Humans
;
Young Adult


Result Analysis
Print
Save
E-mail