2.Chinese emergency expert consensus on bedside temporary cardiac pacing (2023).
EMERGENCY MEDICINE BRANCH OF CHINESE MEDICAL ASSOCIATION ; BEDSIDE TEMPORARY CARDIAC PACING CONSENSUS EMERGENCY EXPERT GROUP
Chinese Critical Care Medicine 2023;35(7):678-683
Temporary cardiac pacing is an essential technique in the diagnosis and treatment of arrhythmias. Due to its urgency, complexity, and uncertainty, it is necessary to develop an evidence-based emergency operation norms. Currently, there is no specific consensus guidelines at home or abroad. The Emergency Branch of Chinese Medical Association organized relevant experts to draft the Chinese emergency expert consensus on bedside temporary cardiac pacing (2023) to guide the operation and application of bedside cardiac pacing. The formulation of the consensus adopts the consensus meeting method and the evidentiary basis and recommendation grading of the Oxford Center for Evidence-based Medicine in the United States. A total of 13 recommendations were extracted from the discussion on the methods of bedside temporary cardiac pacing, the puncture site of transvenous temporary cardiac pacing, the selection of leads, the placement and placement of leads, pacemaker parameter settings, indications, complications and postoperative management. The recommended consensus includes the choice between transcutaneous and transvenous pacing, preferred venous access for temporary transvenous pacing, the target and best guidance method for implantation of bedside pacing electrodes, recommended default pacemaker settings, recommended indications for sinoatrial node dysfunction, atrioventricular block, acute myocardial infarction, cardiac arrest, ventricular and supraventricular arrhythmias. They also recommended ultrasound guidance and a shortened temporary pacing support time to reduce complications of temporary transvenous cardiac pacing, recommended bedrest, and anticoagulation after temporary transvenous pacing. Bedside temporary cardiac pacing is generally safe and effective. Accurate assessment, correct selection of the pacing mode, and timely performance of bedside temporary cardiac pacing can further improve the survival rate and prognosis of related emergency patients.
Humans
;
Cardiac Pacing, Artificial/methods*
;
Pacemaker, Artificial
;
Arrhythmias, Cardiac/therapy*
;
Myocardial Infarction/therapy*
;
Electrodes
4.Study on Impedance of Implantable Cardiac Pacemaker in Unipolar/Bipolar Pacing Mode by in Vitro Experiment.
Ding DING ; Kai-Bin LIN ; Dong HUANG ; Xin-Wei GUO ; Yan-Peng WANG ; Shuai LI ; Jing-Bo LI ; Jin-Hai NIU
Chinese Journal of Medical Instrumentation 2022;46(3):237-241
The unipolar/bipolar pacing mode of pacemaker is related to its circuit impedance, which affects the battery life. In this study, the in vitro experiment scheme of pacemaker circuit impedance test was constructed. The human blood environment was simulated by NaCl solution, and the experimental environment temperature was controlled by water bath. The results of in vitro experiments showed that under the experimental conditions similar to clinical human parameters, the difference between the circuit impedance of bipolar mode and unipolar mode is 120~200 Ω. The results of the in vitro experiment confirmed that the circuit impedance of bipolar circuit was larger than that of unipolar mode, which was found in clinical practice. The results of this study have reference value to the optimization of pacing mode and the reduction of pacemaker power consumption.
Cardiac Pacing, Artificial/methods*
;
Electric Impedance
;
Humans
;
Pacemaker, Artificial
;
Prostheses and Implants
5.Predictive value of impedance of leadless pacemaker during implantation on trend changes of pacing threshold.
Zhen Jiang LIU ; Zhi Hong WU ; Yi Chao XIAO ; Ying Xu MA ; Xu Ping LI ; Hui YANG ; Tao TU ; Sheng Hua ZHOU ; Qi Ming LIU
Chinese Journal of Cardiology 2022;50(2):150-153
Objective: To explore the predictive value of the impedance measured during leadless pacemaker Micra implantation on the trend of changes of pacing threshold post implantation. Methods: This is a retrospective cross-sectional study. Patients who received implantation of leadless pacemaker Micra at the Second Xiangya Hospital of Central South University from December 2019 to August 2020 were enrolled. The clinical data and the intraoperative electrical parameters during leadless pacemaker implantation were collected. The impedance and pacing threshold data were analyzed at three time points: immediate release, 5-10 min after release, and after traction test. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were used to analyze the value of the impedance at immediate release on predicting the trend of changes of pacing threshold post implantation. Results: A total of 21 patients (mean age: (72.2±12.5) years, 12 males) were included. The impedance of 21 patients was (798.1±35.3) Ω immediately after implantation, (800.9±35.6) Ω after 5-10 minutes of release, and (883.6±31.7) Ω after traction test. Impedance was similar between the three time points (P>0.05). The threshold was (0.97±0.11) V/0.24 ms immediately after implantation, (0.95±0.12) V/0.24 ms at 5-10 min after the release, and (0.59±0.06) V/0.24 ms after the traction test. The threshold was significantly lower after the traction test than that immediately after release (P=0.003) and than that at 5-10 minutes after release (P=0.008), suggesting a decreased tendency of the threshold over time. According to the analysis of the ROC curve, the immediate impedance after the release ≥680 Ω could predict the ideal pacing threshold after the traction test (AUC=0.989, 95%CI 0.702-0.964, P<0.001), the prediction sensitivity was 87%, and the specificity was 100%. The pacing threshold would be not ideal with the immediate impedance ≤ 520 Ω (95%CI 0.893-1.000, P<0.001), the sensitivity was 100%, and the specificity was 80%. Conclusions: The impedance immediately after the release has predictive value for the changing trend of threshold post leadless pacemaker Micra implantation. Impedance ≥680 Ω immediately after release is often related with ideal pacing threshold after the traction test. In contrast, the impedance ≤ 520 Ω pacing is often related with unsatisfactory threshold after the traction test, therefore, it is recommended to find a new pacing site to achieve the impedance ≥680 Ω immediately after release during leadless pacemaker Micra implantation.
Aged
;
Aged, 80 and over
;
Cardiac Pacing, Artificial
;
Cross-Sectional Studies
;
Electric Impedance
;
Humans
;
Male
;
Middle Aged
;
Pacemaker, Artificial
;
Retrospective Studies
;
Treatment Outcome
6.Left ventricular systolic function between left bundle branch pacing and right ventricular septum pacing in patients with pacemaker dependence by three-dimensional speckle tracking imaging.
Heling WEN ; Yu CHEN ; Zhongshu LIANG
Journal of Central South University(Medical Sciences) 2021;46(4):379-384
OBJECTIVES:
To compare the left ventricular systolic function between the 1eft bundle branch pacing (LBBP) and right ventricular septum pacing (RVSP) in patients with pacemaker dependence by three-dimensional speckle tracking imaging (3D-STI).
METHODS:
A total of 65 patients with atrioventricular block (AVB) (Mobitz type II second-degree AVB, high-degree AVB, or third-degree AVB), who underwent permanent cardiac pacing implantation including 32 patients receiving LBBP (LBBP group) and 33 patients receiving RVSP (RVSP group) from June 2018 to June 2019,were enrolled in this study. These patients met the following inclusion criterion: pre-operative left ventricular ejection fraction (LVEF)>50% and ventricular pacing rate>40% at 6-month programming follow-up; and the patients underwent echocardiography at pre-operation and 6 months after operation. The 3D-STI was used to obtain global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), and global area strain (GAS).
RESULTS:
All the patients in the LBBP group and the RVSP group had normal LVEF, there was no significant difference between the 2 group (
CONCLUSIONS
For patients with pacemaker dependence and normal LVEF at pre-operation, the cardiac function in the LBBP group is not significantly better than that in the RVSP group in short term follow-up. But in terms of physiologic pacing and long-term cardiac function protection, the 1eft bundle branch pacing is an optimal pacing mode.
Bundle of His
;
Cardiac Pacing, Artificial
;
Humans
;
Pacemaker, Artificial
;
Stroke Volume
;
Ventricular Function, Left
;
Ventricular Septum/diagnostic imaging*
7.Clinical characteristics of patients with indication of cardiac implantable electronic devices implantation complicating with acute pulmonary thromboembolism.
Xiao Hui NING ; Wen Tao MA ; Xiao Han FAN ; Xiao Fei LI ; Qian WANG ; Zhi Min LIU ; Shu ZHANG
Chinese Journal of Cardiology 2020;48(10):837-841
Objective: To investigate the clinical characteristics of inpatients with the indication of cardiac implantable electronic devices (CIED) therapy and combined acute pulmonary thromboembolism (APTE). Methods: We retrospectively screened 8 641 inpatients who admitted with the indication of CIED implantation in Fuwai Hospital from January 2014 to May 2019. The clinical characteristics, management strategies and clinical outcome were analyzed for patients diagnosed as APTE. Results: APTE were identified in 45 (5‰) patients in this cohort, there were 18(40%) male patients, the average age was (73±8) years old and body mass index was (27±10) kg/m2.Thirty-two (70%) patients were at intermediate-risk and 13 (30%) at low-risk. Anti-coagulation therapy was initiated in 38(84%) patients, and 30 patients underwent CIED implantation (27 pacemaker, 2 CRT and 1 ICD). No postoperative bleeding or pocket hematoma were detected in the 23 patients taking anticoagulation medication before implantation. During an average of (30±7) months' follow up, thrombus was dissolved in 20 patients, hemorrhage complications were observed in 2 patients (1 cerebral hemorrhage and 1 hematuria), anticoagulation therapy was discontinued in these 2 patients. Among 15 patients without immediate CIED implantation and treated with anticoagulation therapy during hospitalization, 2 patients developed complete paroxysmal Ⅲ° atrioventricular block, and recovered after therapy during hospitalization. Seven patients were re-hospitalized for CIED implantation due to bradycardia. Five patients died during follow-up (3 sudden cardiac death, 1 APTE combined with cerebral infarction, and 1 pulmonary infection). Conclusion: APTE is not rare in patients with the indication of CIED implantation, CIED implantation and anti-coagulation therapy are safe for these patients, and transient atrioventricular block could be detected in APTE patients.
Aged
;
Aged, 80 and over
;
Death, Sudden, Cardiac
;
Defibrillators, Implantable
;
Female
;
Humans
;
Male
;
Pacemaker, Artificial
;
Pulmonary Embolism/complications*
;
Retrospective Studies
8.A low-pass filter of 300 Hz improved the detection of pacemaker spike on remote and bedside electrocardiogram.
Jian SUN ; Qiu-Feng LU ; Yan ZHAO ; Peng-Pai ZHANG ; Jun WANG ; Qun-Shan WANG ; Xiao-Hong LIU ; Yi-Gang LI
Chinese Medical Journal 2019;132(5):534-541
BACKGROUND:
The current upper-frequency cutoff of 150 Hz sometimes causes loss of pacemaker spike and misdiagnosis. We hypothesized that low-pass filter (LPF) other than 150 Hz could improve the detection of pacemaker spike. This study aimed to examine the effect of different LPF on pacemaker spike detection in remote and bedside electrocardiogram (ECG).
METHODS:
Patients with permanent pacemaker implantation were included during routine follow-up. Standard 12-lead ECGs at 6 different upper-frequency cutoff (40, 100, 150, 200, 300, and 400 Hz) were collected. All ECGs were then transmitted to the remote clinic center. Ventricular and atrial pacing were analyzed by 2 independent medical practitioners.
RESULTS:
A total of 88 patients' ECGs were analyzed (mean age 73.8 ± 10.2 years and 85 with dual-chamber pacemakers). About 75.3% (64/85) of patients were diagnosed as atrial pacing by pacemaker programming. Among 6 different upper-frequency cutoff, the 300 Hz turned out to perform best in detecting atrial-paced spike (area under the curve [AUC] = 0.73, 95% confidence interval [CI]: 0.61-0.84 vs. 0.56, 95% CI: 0.61-0.84 at 150 Hz; P = 0.002) on bedside ECGs. Using programming as the golden standard, the 300 Hz LPF has a sensitivity of 59.4%, specificity of 85.7%, positive predictive value of 92.7% and negative predictive value of 40.9% on bedside ECGs. As for the ventricular pacing, the 300 Hz LPF also had a higher accuracy (AUC = 0.93; 95% CI = 0.84-1.00) than that at 150 Hz (AUC = 0.86; 95% CI: 0.77-0.94; P < 0.001) in detecting ventricular-paced spike on bedside ECGs. The results of remote ECGs were similar with bedside ECGs.
CONCLUSIONS
A filter of 300 Hz cutoff may be recommended for ECG spike detection. With the recommended parameter, remote ECG can perform as well as bedside ECG.
Aged
;
Aged, 80 and over
;
Cardiac Pacing, Artificial
;
Electrocardiography
;
methods
;
Female
;
Humans
;
Male
;
Middle Aged
;
Pacemaker, Artificial
;
Retrospective Studies
9.Temporal Trends of Cardiac Implantable Electronic Device Implantations: a Nationwide Population-based Study
Ji Hyun LEE ; So Ryoung LEE ; Eue Keun CHOI ; Jaehan JEONG ; Hyung Deuk PARK ; So Jeong YOU ; Sang Soo LEE ; Seil OH
Korean Circulation Journal 2019;49(9):841-852
BACKGROUND AND OBJECTIVES: Implantation of cardiac implantable electronic devices (CIED), including permanent pacemakers (PM), implantable cardioverter-defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, has increased significantly over the past several years. However, limited data exists regarding temporal trends of CIED implantations in Asian population. This study aimed to investigate temporal trends of CIED treatment in Korea. METHODS: Using the National Health Insurance Service database of the entire Korean adult population, temporal trends of CIED procedures between 2009 and 2016 were evaluated. Additionally, temporal changes in the prevalence of patients' comorbidities were evaluated. RESULTS: A total of 35,421 CIED procedures (new implantations: 27,771, replacements: 7,650) were performed during the study period. The mean age of new CIED recipients and the prevalence of comorbidities, including hypertension, diabetes mellitus, heart failure, stroke, and atrial fibrillation, increased substantially with time. Compared to 2009, the number of new implantations of PM, ICD, and CRT devices increased by 2.0 (1,977 to 3,910), 3.6 (230 to 822), and 4.9 (44 to 217) times in 2016, respectively. The annual new implantation rate of CIED also increased accordingly (5.1 to 9.3 for PM, 0.6 to 1.9 for ICD, and 0.1 to 0.5 for CRT devices, per 100,000 persons). CONCLUSIONS: The number of CIED implantation increased substantially from 2009 to 2016 in Korea. Also, the patients with CIED have been changed to be older and have more comorbidities. Therefore, the burden of health care cost in patients with CIED would be expected to increase in the future.
Adult
;
Asian Continental Ancestry Group
;
Atrial Fibrillation
;
Cardiac Resynchronization Therapy
;
Comorbidity
;
Defibrillators, Implantable
;
Diabetes Mellitus
;
Epidemiology
;
Health Care Costs
;
Heart Failure
;
Humans
;
Hypertension
;
Korea
;
National Health Programs
;
Pacemaker, Artificial
;
Prevalence
;
Stroke