4.Treatment and outcome of a young female patient with severe aortic stenosis and complex coronary disease associated with familial hypercholesterolemia: a case report.
Kai Min WU ; Bin WANG ; Guo Ming ZHANG ; Fei LIU ; Li Cheng DING ; Guang Feng SUN ; Wei Mei OU ; Zhi Xian LIU ; Cheng Min HUANG ; Yan WANG
Chinese Journal of Cardiology 2023;51(3):310-313
5.Gender differences in mortality following tanscatheter aortic valve replacement (TAVR): a single-centre retrospective analysis from China.
Qi LIU ; Yali WANG ; Yijian LI ; Tianyuan XIONG ; Fei CHEN ; Yuanweixiang OU ; Xi WANG ; Yijun YAO ; Kaiyu JIA ; Yujia LIANG ; Xin WEI ; Xi LI ; Yong PENG ; Jiafu WEI ; Sen HE ; Qiao LI ; Wei MENG ; Guo CHEN ; Wenxia ZHOU ; Mingxia ZHENG ; Xuan ZHOU ; Zhengang ZHAO ; Chen MAO ; Feng YUAN
Chinese Medical Journal 2023;136(20):2511-2513
6.Peri-procedural myocardial injury predicts poor short-term prognosis after TAVR: A single-center retrospective analysis from China.
Qi LIU ; Kaiyu JIA ; Yijun YAO ; Yijian LI ; Tianyuan XIONG ; Fei CHEN ; Yuanweixiang OU ; Xi WANG ; Yujia LIANG ; Xi LI ; Yong PENG ; Jiafu WEI ; Sen HE ; Qiao LI ; Wei MENG ; Guo CHEN ; Wenxia ZHOU ; Mingxia ZHENG ; Xuan ZHOU ; Yuan FENG ; Mao CHEN
Chinese Medical Journal 2023;136(24):3013-3015
7.In Vitro Experimental Study on Hemodynamics of Transcatheter Aortic Valve Replacement.
Chinese Journal of Medical Instrumentation 2023;47(4):383-390
The patient-specific aortic silicone model was established based on CTA data. The digital particle image velocimetry (DPIV) test method in the modified ViVitro pulsatile flow system was used to investigate the aortic hemodynamic performance and flow field characteristics before and after transcatheter aortic valve replacement (TAVR). The results showed that the hemodynamic parameters were consistent with the clinical data, which verified the accuracy of the model. From the comparative study of preoperative and postoperative effective orifice area (0.33 cm2 and 1.78 cm2), mean pressure difference (58 mmHg and 9 mmHg), percentage of regurgitation (52% and 8%), peak flow velocity (4.60 m/s and 1.81 m/s) and flow field distribution (eccentric jet and uniform jet), the immediate efficacy after TAVR is good. From the perspective of viscous shear stress and Reynolds shear stress, the risk of hemolysis and thrombotic problems was low in preoperative and postoperative patient-specific models. This study provides a set of reliable DPIV testing methods for aortic flow field, and provides biomechanical basis for the immediate and long-term effectiveness of TAVR from the perspective of hemodynamics and flow field characteristics. It has important application value in clinical diagnosis, surgical treatment and long-term evaluation.
Humans
;
Transcatheter Aortic Valve Replacement/methods*
;
Aortic Valve/surgery*
;
Heart Valve Prosthesis
;
Hemodynamics
;
Aortic Valve Stenosis/diagnosis*
;
Treatment Outcome
8.Cerebral ischemic injury after transcatheter aortic valve replacement in patients with pure aortic regurgitation.
Xianbao LIU ; Hanyi DAI ; Jiaqi FAN ; Dao ZHOU ; Gangjie ZHU ; Abuduwufuer YIDILISI ; Jun CHEN ; Yeming XU ; Lihan WANG ; Jian'an WANG
Journal of Zhejiang University. Science. B 2023;24(6):530-538
Considering the surgical risk stratification for patients with severe calcific aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) is a reliable alternative to surgical aortic valve replacement (SAVR) (Fan et al., 2020, 2021; Lee et al., 2021). Despite the favorable clinical benefits of TAVR, stroke remains a dreaded perioperative complication (Auffret et al., 2016; Kapadia et al., 2016; Kleiman et al., 2016; Huded et al., 2019). Ischemic overt stroke, identified in 1.4% to 4.3% of patients in TAVR clinical practice, has been associated with prolonged disability and increased mortality (Auffret et al., 2016; Kapadia et al., 2016; Levi et al., 2022). The prevalence of hyperintensity cerebral ischemic lesions detected by diffusion-weighted magnetic resonance imaging (DW-MRI) was reported to be about 80%, which is associated with impaired neurocognitive function and vascular dementia (Vermeer et al., 2003; Barber et al., 2008; Kahlert et al., 2010).
Humans
;
Transcatheter Aortic Valve Replacement
;
Aortic Valve Insufficiency
;
Diffusion Magnetic Resonance Imaging
;
Aortic Valve Stenosis
;
Stroke

Result Analysis
Print
Save
E-mail