1.Ultrasound evaluation of clinical mimics of deep vein thrombosis: essential insights for radiologists in interpretation
Dongsuk IM ; Lyo Min KWON ; Sun Young PARK ; Min Su PARK ; Won Ju HONG
Ultrasonography 2025;44(3):171-188
Ultrasonography (US) is a sensitive and radiation-free technique for diagnosing deep vein thrombosis (DVT). Therefore, when DVT is clinically suspected but not detected on US, radiologists should consider a range of alternative differential diagnoses. This review article presents the imaging findings of clinical conditions that mimic DVT, which can be distinguished using a multimodal radiologic approach. Additionally, DVT mimics can be categorized into two groups based on whether a flat or normal waveform is observed on Doppler US. This article details the imaging findings and clinical presentations of DVT mimics, organized by these classifications. This information may help radiologists make more accurate diagnoses, enabling patients to receive appropriate treatment in a timely manner.
2.Ultrasound evaluation of clinical mimics of deep vein thrombosis: essential insights for radiologists in interpretation
Dongsuk IM ; Lyo Min KWON ; Sun Young PARK ; Min Su PARK ; Won Ju HONG
Ultrasonography 2025;44(3):171-188
Ultrasonography (US) is a sensitive and radiation-free technique for diagnosing deep vein thrombosis (DVT). Therefore, when DVT is clinically suspected but not detected on US, radiologists should consider a range of alternative differential diagnoses. This review article presents the imaging findings of clinical conditions that mimic DVT, which can be distinguished using a multimodal radiologic approach. Additionally, DVT mimics can be categorized into two groups based on whether a flat or normal waveform is observed on Doppler US. This article details the imaging findings and clinical presentations of DVT mimics, organized by these classifications. This information may help radiologists make more accurate diagnoses, enabling patients to receive appropriate treatment in a timely manner.
3.Ultrasound evaluation of clinical mimics of deep vein thrombosis: essential insights for radiologists in interpretation
Dongsuk IM ; Lyo Min KWON ; Sun Young PARK ; Min Su PARK ; Won Ju HONG
Ultrasonography 2025;44(3):171-188
Ultrasonography (US) is a sensitive and radiation-free technique for diagnosing deep vein thrombosis (DVT). Therefore, when DVT is clinically suspected but not detected on US, radiologists should consider a range of alternative differential diagnoses. This review article presents the imaging findings of clinical conditions that mimic DVT, which can be distinguished using a multimodal radiologic approach. Additionally, DVT mimics can be categorized into two groups based on whether a flat or normal waveform is observed on Doppler US. This article details the imaging findings and clinical presentations of DVT mimics, organized by these classifications. This information may help radiologists make more accurate diagnoses, enabling patients to receive appropriate treatment in a timely manner.
4.Ultrasound evaluation of clinical mimics of deep vein thrombosis: essential insights for radiologists in interpretation
Dongsuk IM ; Lyo Min KWON ; Sun Young PARK ; Min Su PARK ; Won Ju HONG
Ultrasonography 2025;44(3):171-188
Ultrasonography (US) is a sensitive and radiation-free technique for diagnosing deep vein thrombosis (DVT). Therefore, when DVT is clinically suspected but not detected on US, radiologists should consider a range of alternative differential diagnoses. This review article presents the imaging findings of clinical conditions that mimic DVT, which can be distinguished using a multimodal radiologic approach. Additionally, DVT mimics can be categorized into two groups based on whether a flat or normal waveform is observed on Doppler US. This article details the imaging findings and clinical presentations of DVT mimics, organized by these classifications. This information may help radiologists make more accurate diagnoses, enabling patients to receive appropriate treatment in a timely manner.
5.Ultrasound evaluation of clinical mimics of deep vein thrombosis: essential insights for radiologists in interpretation
Dongsuk IM ; Lyo Min KWON ; Sun Young PARK ; Min Su PARK ; Won Ju HONG
Ultrasonography 2025;44(3):171-188
Ultrasonography (US) is a sensitive and radiation-free technique for diagnosing deep vein thrombosis (DVT). Therefore, when DVT is clinically suspected but not detected on US, radiologists should consider a range of alternative differential diagnoses. This review article presents the imaging findings of clinical conditions that mimic DVT, which can be distinguished using a multimodal radiologic approach. Additionally, DVT mimics can be categorized into two groups based on whether a flat or normal waveform is observed on Doppler US. This article details the imaging findings and clinical presentations of DVT mimics, organized by these classifications. This information may help radiologists make more accurate diagnoses, enabling patients to receive appropriate treatment in a timely manner.
6.Investigating the prevalence and clinical symptoms of non-convulsive seizures in emergency department patients with unexplained altered consciousness using real-time portable continuous electroencephalographic monitoring
Soo Wook KIM ; Won Soek YANG ; Jin Hyouk KIM ; Sang Ook HA ; Young Sun PARK
Journal of the Korean Society of Emergency Medicine 2024;35(5):353-363
Objective:
A wireless electroencephalography (EEG) headset was applied to patients with an unclear etiology of an altered mental status suspected of non-convulsive seizures in the emergency department.
Methods:
The study included patients who presented to the emergency department with an altered mental status from January 1, 2020, to April 30, 2023. The patients with abnormal findings in brain imaging or those with typical seizure movement were excluded. Real-time portable continuous EEG monitoring was conducted on patients with persistent altered consciousness despite receiving conservative treatments and showing improvement in vital signs and blood tests within 3 hours. The baseline characteristics, degree of consciousness alteration and neurological symptoms, initial clinical diagnosis, EEG findings, and medications used in cases where epileptiform discharges were examined. The clinical outcomes were analyzed retrospectively.
Results:
Among 26 patients, six patients showed epileptiform discharges. The final diagnoses included uremic encephalopathy (n=2), septic encephalopathy due to pneumonia (n=1), urinary tract infection (n=1), diabetic ketoacidosis (n=1), and mental change only (n=1). The associated symptoms were myoclonus in three patients and abnormal eye movements in two patients.
Conclusion
In cases where the causes of altered mental status remain unexplained despite appropriate evaluations and treatments, particularly when accompanied by myoclonus or abnormal eye movements, it is crucial to consider the possibility of non-convulsive seizures and promptly perform an EEG to differentiate and diagnose the underlying condition, even if initial tests and treatments have been performed.
7.How many times should we repeat measurements of the ultrasound-guided attenuation parameter for evaluating hepatic steatosis?
Duck Min SEO ; Sang Min LEE ; Ji Won PARK ; Min-Jeong KIM ; Hong Il HA ; Sun-Young PARK ; Kwanseop LEE
Ultrasonography 2023;42(2):227-237
Purpose:
This retrospective study aimed to determine the number of times the ultrasound-guided attenuation parameter (UGAP) should be measured during the evaluation of hepatic steatosis.
Methods:
Patients with suspected nonalcoholic fatty liver disease who underwent two UGAP repetition protocols (six-repetition [UGAP_6] and 12-repetition [UGAP_12]) and measurement of the controlled attenuation parameter (CAP) using transient elastography between October 2020 and June 2021 were enrolled. The mean attenuation coefficient (AC), interquartile range (IQR)/median, and coefficient of variance (CV) of the two repetition protocols were compared using the paired t test. Moreover, the diagnostic performances of UGAP_6 and UGAP_12 were compared using the area under the receiver operating characteristic (AUROC) curve, considering the CAP value as a reference standard.
Results:
The study included 160 patients (100 men; mean age, 50.9 years). There were no significant differences between UGAP_6 and UGAP_12 (0.731±0.116 dB/cm/MHz vs. 0.734±0.113 dB/cm/MHz, P=0.156) and mean CV (7.6±0.3% vs. 8.0±0.3%, P=0.062). However, the mean IQR/median of UGAP_6 was significantly lower than that of UGAP_12 (8.9%±6.0% vs. 9.8%±5.2%, P=0.012). In diagnosing the hepatic steatosis stage, UGAP_6 and UGAP_12 yielded comparable AUROCs (≥S1, 0.908 vs. 0.897, P=0.466; ≥S2, 0.883 vs. 0.897, P=0.126; S3, 0.832 vs. 0.834, P=0.799).
Conclusion
UGAP had high diagnostic performance in diagnosing hepatic steatosis, regardless of the number of repetitions (six repetitions vs. 12 repetitions), with maintained reliability. Therefore, six UGAP measurements seem sufficient for evaluating hepatic steatosis using UGAP.
8.Effects of X-ray volume imaging registration methods on position verification for radiotherapy in treatment of middle/lower-segment esophageal cancer
Haojia LIU ; Huitao WANG ; Hongwei XU ; Anping ZHENG ; Xiaodong SUN ; Jinfeng ZHU
Chinese Journal of Radiological Health 2023;32(1):52-57
Objective To compare the set up errors derived from different registration methods of the X-ray volume imaging (XVI) system for radiotherapy in the treatment of middle/lower-segment esophageal cancer, and to provide a reference for radiation treatment of esophageal cancer. Methods We randomly selected 63 patients with middle/lower-segment esophageal cancer, and obtained their reconstructed XVI images at the first therapy to perform automatic registration with gray-value and bone registration methods. We acquired and compared the three translation errors (along x [left to right], y [head to feet], and z [front to back] axes) and three rotation errors (around the x, y, and z axes) derived from the two registration methods. Results Gray-value registration had significantly smaller translation errors along the x and z axes than bone registration (x azes t = −2.78, z azes t = −2.15, P < 0.05), but there was no significant difference along the y axes (P > 0.05). The rotation errors around the three axes were all smaller than 1°, and were smaller with gray-value registration than with bone registration, but without significant differences (P > 0.05). Conclusion We recommend gray-value registration for radiotherapy in the treatment of middle/lower-segment esophageal cancer. Manual verification or fine-tuning is recommended after automatic registration in clinical practice. Besides translation errors, rotation errors should also be paid attention to.
9.Palinacousis after Cerebral Venous Thrombosis in the Temporoparietal Lobe
Euihyun KIM ; Na Hee KIM ; Myun KIM ; Chaery JEON ; In Hee KWAK ; Mi Sun OH ; Chi-Hun KIM
Journal of the Korean Neurological Association 2023;41(4):324-327
Palinacousis is a rare auditory phenomenon characterized by the persistence of sounds beyond their actual duration. It has been associated with various brain conditions such as stroke, tumor, and seizure in the temporoparietal lobe. We present a case report of a 43-yearold man who developed palinacousis following cerebral venous thrombosis and seizure with lesions including the left auditory cortex. This case highlights the intriguing relationship between cerebral venous infarction, seizure, and the development of palinacousis in specific brain regions.
10.Cilostazol and Probucol for Cognitive Decline after Stroke: A Cognitive Outcome Substudy of the PICASSO Trial
Jae-Sung LIM ; Sun U. KWON ; Kyung-Ho YU ; Sungwook YU ; Jong-Ho PARK ; Byung-Chul LEE ; Mi Sun OH ; Yong-Jae KIM ; Joung-Ho RHA ; Yang-Ha HWANG ; Ji Sung LEE ; Sung Hyuk HEO ; Seong Hwan AHN ; Woo-Keun SEO ; Jong-Moo PARK ; Ju-Hun LEE ; Jee-Hyun KWON ; Sung-Il SOHN ; Jin-Man JUNG ; Hahn Young KIM ; Eung-Gyu KIM ; Jae-Kwan CHA ; Man-Seok PARK ; Hyo Suk NAM ; Hee-Joon BAE ; Dong-Eog KIM ; Jaeseol PARK ; Yeonwook KANG ; Jimi CHOI ; Juneyoung LEE
Journal of Stroke 2021;23(1):128-131


Result Analysis
Print
Save
E-mail