1.Influencing factors on thrombin time assay by coagulation specimen insufficient centrifugation
Aisheng LIU ; Liyun LIN ; Xiaojun LIU
Chinese Medical Equipment Journal 2017;38(2):101-103
Objective To investigate the influencing factors on thrombin time (TT) assay to ensure the accuracy of the detection results.Methods Totally 3 out-and in-patients from January to July 2015 with normal results of prothrombin time (PT),activated partial clotting enzyme live time (APTT) and fibrinogen (FIB) were selected,whose detection results were not satisfactory.The specimen underwent re-centrifugation,and then Beckman ACL TOP700 automatic coagulation analyzer was used to detect four coagulation indexes.The detection results were compared with those before re-centrifugation,and the differences between the results were analyzed statically.Results The values of PT,APTT and FIB of the three patients before and after re-centrifugation were (10.8,11.5,9.7 s),(29.5,32.7,25.2 s),(2.49,3.12,2.85 g/L) and (10.9,11.3,10.0 s),(30.4,31.5,25.9 s),(2.31,3.28,2.67 g/L) respectively,and the differences between the results were not significant (with t ranging from 0.627 to 1.719 and P>0.05).The values of TT of the three patients before and after re-centrifugation were (66.51,127.3,89.62 s) and (12.2,15.7,13.8 s) respectively,and there were obvious differences between the values (with t ranging from 51.743 to 79.167 and P<0.001).Conclusion Insufficient centrifugation has high influences on the detection result of TT except other coagulation indexes,and re-centrifugation is necessary for the accuracy of TT value to eliminate misdiagnosis.
2.Present Situation Investigation of Trace Elements of 0~7 Years Old Children in Shenzhen District
Zhanjing ZHAO ; Aisheng LIU ; Ailing LIU ; Weili XU ; Xuegan YAO
Journal of Modern Laboratory Medicine 2017;32(3):149-151,156
Objective To understand the Shenzhen Dapeng new district and Longhua district 0~7 years old children in copper (Cu),zinc (Zn),calcium (Ca),magnesium (Mg),iron (Fc) and lead (Pb) 6 kinds of trace elements,in order to establish the reasonable dietary structure and provide a scientific basis for scientific and rational supplement of trace elements.Methods Collected 2 190 cases of 0~7 years old children for health physical examination in Dapeng New District Maternal and Child Health Care Hospital of Shenzhen form March to November 2015.According to the age,they were divided into the baby group (0~1 years old) of 637 cases,children group (2~4 years old) of 723 cases and preschool group (4~7 years old) of 830 cases of three groups.Used QL8000 automatic whole blood trace elements analyzer to test Fe,Zn,Ca,Cu,Mg and Pb 6 kinds of trace elements in whole blood,and the detection results were statistically analyzed and compared.Results Test results of 5 kinds of whole blood trace element(Fe,Zn,Ca,Cu,Mg) had different degrees lack in 2 190 cases of children aged 0 ~7,and lack of different level,lack of rate were 36.26%,32.83%,14.20%,0.64% and 0.50%,respectively.Fe and Ca deficiency in young children group was most serious,lack of Zn in infant group was most serious,other microelement lack rate had no statistically significant difference between different groups (P> 0.05).Pb poisoning rate was 15.71%,the Pb poisoning rate decreases along with the age growth,and boys than girls,the difference was statistically significant (x2=3.15,P <0.05),different gender children other microelement lack rate differences had no statistical significance between the results.Conclusion The whole blood trace element of 0~7 years old children had different lack,mainly by Fe,Zn and Ca deficiency in Shenzhen Dapeng New District and Longhua District.But Children's Pb poisoning problem could not be ignored.Therefore,to streng then the 0~ 7 years old children's whole blood trace elements level survey,microelement lack of prevention and treatment of children is of great significance.
3.Prevalence Situation Investigation and Study on E Viral Hepatitis in Different Types of Chronic Hepatitis
Yuanhuan LIU ; Aisheng LIU ; Yan WEN
Journal of Modern Laboratory Medicine 2016;(1):152-154
Objective To understand the different types of chronic hepatitis group in shenzhen area E viral hepatitis (hepatitis E infection status and provide scientific basis for the prevention and treatment of hepatitis E.Methods Randomly collected from July 2013 to June 2015 in shenahen Longhua New District People’s Hospital without hepatitis normal physical exami-nation and treatment group 1746 cases as control group,chronic hepatitis B viral hepatitis (hepatitis B)the crowd of 1 320 cases of hepatitis B,chronic viral hepatitis C (HCV)population group,615 cases of hepatitis C,respectively,the application method of enzyme-linked immunosorbent assay (ELISA)to detect serum hepatitis E antibody (anti HEV IgG)-IgG,ana-lyzed of different types of hepatitis a crowd hepatitise infection status,and compared the hepatitise infection rate if there was a difference between the different groups.Results 1 746 cases of control group in serum anti HEV-IgG positive rate was 3.49% (61/1 746),4.22% of men and women in 2.68%.1 320 cases of hepatitis B group was 10.9%,12.29% of men and women in 8.23%.615 cases of C group was 10.2%,12.35% of men and women in 7.64%.Hepatitis B and C group of HEV-IgG positive rate compared with control group difference was statistically significant (χ2 =9.163~9.405,P <0.05), and hepatitis B and hepatitis C group there was no statistically significant difference between positive HEV-resistant IgG (χ2=0.614,P >0.614),and hepatitis E infection rate than women,men was statistically significant difference (χ2 =2.873~4.025,P <0.05).Conclusion Chronic hepatitis B and C viral hepatitis crowd anti HEV-IgG positive rate was higher than normal people,no hepatitis hepatitis E infection rate among men than women.Therefore,strengthens to the chronic hepatitis B and C viral hepatitis a crowd of early discovery,early diagnosis and early treatment,to reduce hepatitis E infection rate has an important significance.
4.Investigation and Study on the Present Situation of Genetic Defect Carrying Rate in Unmarried Young Men with Thalassaemia
Wang CHEN ; Aisheng LIU ; Yan WEN ; Jian YANG
Journal of Modern Laboratory Medicine 2016;31(3):121-123,126
Objective To understand the present situation of the rate of carry genetic defect in Unmarried young men with thalassaemia in Shenzhen,which will provide a scientific basis for correct mating.Methods Randomly selected 6 182 cases of unmarried young people from March 2014 to October 2015 to hospital physical examination,Used Sysmex XN-9000 auto-matic blood cell sextant and erythrocyte osmotic fragility test to sccreen preliminarily for globin generation barrier anemia. The average red blood cell volume (MCV)≤82 fl and the average content of red blood cell (MCH)≤27 pg or osmotic fra-gility of red blood cells rate<60% of the population was made hemoglobin electrophoresis analysis.To early screening posi-tive by PCR,it was done reverse dot hybridization method for gene diagnosis,and the results were analyzed.Results 6 182 cases of unmarried young men at the beginning of globin generation barrier anemia screen positive rate was 17.3% (1 069/6 182),including suspectedα-was 12.2% (752/6 182)and suspiciousβ-was 5.1% (317/6 182).Gene diagnosis of globin generation barrier anemia positive rate was 11.6% (717/6 182),theα-was 6.7% (413/6 182),β-was 3.4% (209/6 182) and compoundαβ-was 1.5% (95/6 182).α-genetic defect types were mainly--SEA/αα,-α3.7/ααand-α4.2/ααand defect rate were 60.8%,23.5% and 10.4%,respectively.β-gene defect types are mainly CD41/42,CD17 and-28,defect rate were 41.1%,28.2% and 12.9%,respectively.Conclusion Unmarried young men in shenzhen area globin generation barrier ane-mia has certain carrying rate,local family planning department attaches great importance to it.Strengthen the unmarried young men globin generation barrier anemia screening,to guide the healthy birth mating and prevention of severe pauper’s birth,improve the rate of eugenic and superior nurture,has the vital significance.
5.The performance evaluation of emergency immunological parameters in Johnson Vitros 5600 fully automatic biochemical analyzer
Liyun LIN ; Xiaojun LIU ; Aisheng LIU
China Medical Equipment 2016;13(5):38-40,41
Objective:To have the performance verification of Johnson Vitros 5600 fully automatic biochemical analyzer (hereinafter referred to as Vitros 5600 analyzer) emergency immunological parameter is to provide more accurate and more efficient service for the patients in emergency inspection items.Methods: According to the clinical laboratory standards institute (CLSI) evaluation criterion and Johnson validation plan, we verified the precision, accuracy, linear range, reference range, and carry pollution rate detection indexes of Myoglobin, Troponin I (TropI), N-terminal brain natriuretic titanium (NTproBNP) and total beta human chorionic gonadotropin (TβHCG) about the Vitros 5600 analyzer emergency projects evaluated the performance of the analyzer.Results: The batch precision CV of Myoglobin, TropI, NTproBNP and TβHCG tested by Vitros 5600 analyzer is 0.58~2.02%, < 2.5%, and the inter assay CV is 1.43~3.15%, < 5.0%. Accuracy relative bias is -3.52~4.21%. Linearity relationship is good within the scope of testing,r2 is 0.9836~0.9998, and the slope (a) is 0.9865~1.0207. Carry pollution rate is 0.096~0.180%. Reference range verification coincidence rate is R≥95%.Conclusion: The detection index performance of Vitros 5600 analyzer detecting immune emergency projects is good. It can meet the demand of emergency immune inspection work.
6.Clinical value in early diagnosis of myocardial damage with h-FABP, cTnI, Mb and CK-Mb joint detection to HFMD in children
Xiaoge LIU ; Xiaoyan PAN ; Aisheng LIU
China Medical Equipment 2016;13(10):89-91,92
Objective:To explore the early diagnostic value of joint detection heart type fatty acid binding protein (h-FABP), troponin (cTnI), myoglobin (Mb) and creatine kinase isoenzyme Mb (CK-Mb) in children's hand, foot and mouth disease (HFMD) combined myocardial injury.Methods: Choice 276 cases of HFMD as observation group, and 40 healthy children as control group. Were determined h-FABP, cTnI, Mb and CK-Mb content in serum at different time, analysis of various index level differences and dynamic change between groups in different period.Results: Among 276 patients with HFMD, 57 cases of diagnosed myocarditis, concurrent rate was 20.65%. Within 0~3 hrs, abnormal rate of h-FABP, cTnI, Mb and CK-Mb in serum were 20.29%,1.81%,14.86% and 2.90%, in 276 cases of children with HFMD. The abnormal rate of h-FABP and Mb was obviously higher than that of cTnI and CK-Mb, the results between the difference was statistically significant (x2=35.132,x2=37.063,P<0.01),h-FABP abnormal rate is higher than CK-Mb, the difference was statistically significant(x2=3.175,P<0.05). the,serum h-FABP cTnI, Mb and CK-Mb concentrations in children of HFDM combined with suspicious viral myocarditis were significantly higher than that of control group, the difference had statistical significance (t=37.625,t=23.172,t=17.261,t=18.724,P<0.01). H-FABP and Mb concentration on HFMD combined myocarditis began to rise after the occurrence of 0~3 h, 4~9 h to peak, CTnI and CK-MB 4~9 h to rise, 10~12 h to peak, has been in a higher level in the 12~72 h.Conclusion: HFMD combined myocarditis had a higher incidence, h-FABP is the most sensitive indicator of early diagnosis, followed by Mb. CTnI and CK-MB are parameters of diagnosis sensitivity for HFMD combined with myocarditis in middle-late period.
7.Research on electrochemical luminescence analyzer test anemia indicators of performance verification methodology
Wei YAO ; Aisheng LIU ; Duzhi FANG
China Medical Equipment 2016;13(1):74-77
Objective:To detect anaemia parameter methodology performance for validation of Roche Cobas E601 automatic electrochemical luminescence immunity analyzer.Methods:Recommended by the American association of clinical laboratory standardization (CLSI) method was developed for the determination of folic acid, iron, protein, and this precision, accuracy, linear range, sensitivity, biological reference range and carry pollution index, and validated.Results: Cohas E601 determination of folic acid, iron, protein and precision, the daytime in this batch variation coefficient were 3.03%~4.27% and 3.51%~4.68%. Relative bias must lean on(%) between -3.54%~4.46%. The scope of determination of linear range and the manufacturer to provide similar. Folic acid, iron, protein and numerical value with the determination of this instrument manufacturers provide reference interval coincidence rate were 90.0%, 85.0% and 90.0% respectivel. Instrument to detect carry pollution rate is 0.04%~0.16%. CohasE601 detection sensitivity were 0.23 ng/ml, 0.21 ng/ml and 0.19 pg/ml.Conclusion: Cobas E601 detect folic acid, iron, protein and good performance of this methodology, but manufacturers provide biological reference range is not suitable for the local crowd, should establish the corresponding normal reference range.
8.ICU Patients with Secondary Pulmonary Tuberculosis Merger Lower Respiratory Infection of Pathogenic Bacteria Distribution and Drug Resistance Analysis
Liyun LIN ; Aisheng LIU ; Yuer WEI ; Lingzhi WEI ; Yanmei WANG ; Junzhu SHI ; Xiaojun LIU ; Yan WEN
Journal of Modern Laboratory Medicine 2016;31(3):138-142
Objective To understand Shenzhen Longgang,guangming and longhua new district four district hospital ICU pa-tients with secondary pulmonary tuberculosis merger lower respiratory infection of pathogenic bacteria distribution and drug resistance status of provide a reference for clinical diagnosis and rational use of antibiotics therapy.Methods Random selec-tion from February 2013 to October 2015 in the three district hospital ICU diagnosis of secondary pulmonary tuberculosis patients with lower respiratory infection in 593 cases of sputum specimen pathogenic bacteria culture and drug susceptibility results were retrospectively analyzed.Results 593 cases of ICU secondary pulmonary tuberculosis patients with respiratory tract infection of the communist party of China isolated 617 strains of pathogenic bacteria,fungi accounted for 49.6% (306/617),gram negative bacilli accounted for 40.4% (249/617),gram positive cocci accounted for 10.0% (62/617).Fungal in-fection main pathogens for white smooth candida yeast and candida yeast,respectively accounted for 44.2% (273/617)and
4.5% (28/617),gram negative bacillus mainlyKlebsiellaPneumoniae,Pseudomonasaeruginosa,and H.influenzae,respec-tively accounted for 16.7% (103/617),12.0% (74/617)and 7.3% (45/617),gram-positive cocci mainly for Saphylococcus aureus and Epidermisstaphylococcus and Hemolyticstaphylococci,respectively accounted for 4.5% (28/617),3.2% (20/617)and 0.9% (5/617).Pathogenicbacteria isolated from the multiple drug resistant bacteria,present different levels of resistance to commonly used antimicrobial agents.Conclusion ICU patients with secondary pulmonary tuberculosis merger of lower respiratory tract infection pathogens to fungi and gram-negative bacilli,the most commonWhite candida,Klebsiella pneumoniae,and Pseudomonasaeruginosa,and different levels of resistance to commonly used antimicrobial agents.
9.Blood analyzer Sysmex XN-9000 testing in low whole blood platelet performance evaluation
Min WU ; Yan WEN ; Aisheng LIU
China Medical Equipment 2015;(8):51-53
Objective:To evaluate the performance of Sysmex XN-9000 automatic blood analyzer (hereinafter referred to as XN-9000) in whole blood with the low platelet (PLT). Methods:A total of 48 whole blood samples with platelet count less than 70×109/L were randomly collected from XN-9000 correlation analysis to evaluate XN-9000 the accuracy and precision of detection in low whole blood PLT and carry pollution rate, use XN-9000 and microscope count, respectively.Results: XN-9000 detection in low whole blood PLT between batch and batch of CV% 1.13% and 1.29%, respectively; XN-9000 with microscope PLT count results have high correlation, The regression equation forY=0.917X+3.217,correlation coefficientr=0.964; XN-9000 detection in low whole blood PLT carry pollution at a rate of 0.12%. Detection accuracy of PLT Bias, %(-1.25%~1.8%); Linear range(0~1206)×109/L; Clinical reportable range (0~6030)×109/L.Conclusion: The detection of XN-9000 blood analyzer is in low whole blood PLT has high precision and accuracy, carry pollution rate is extremely low, the result has the reliability, can be directly applied to clinical.
10.Effect of mixed protamine zinc recombinant human insulin lispro injection on glucose metabolism, immune function in patients with type 2 diabetes and its inflammatory mechanisms
Xuan LIN ; Jiangming LANG ; Aisheng WEI ; Xiaoxia LIU
Chinese Journal of Biochemical Pharmaceutics 2015;37(4):144-146,150
Objective To investigate the mixed protamine zinc recombinant human insulin lispro injection on glucose metabolism, immune function in patients with type 2 diabetes and its inflammatory mechanisms.Methods 125 patients enrolled were randomly divided into two groups according to the random number table: control group (n =61) and observation group (n =64).The control group were received conventional treatment, observation group were received mixed protamine zinc recombinant human insulin lispro injection on the basis of control group, with a course of three months of both groups.The fasting blood glucose (FBG), 2h post prandial blood glucose (2hPG), glycated hemoglobin (HbA1c), fasting insulin, insulin resistance index ( IRI) , CD4 +, CD8 +, CD4 +/CD8 +changes and inflammatory cytokines levels were compared before and after treatment between two groups. Results The level of FBG, 2hPG, HbA1c after treatment was respectively lower than that before treatment in both groups (P<0.05), and the above indexes of observation group after treatment was respectively lower than that of control group (P<0.05).The level of fasting insulin, IRI after treatment was respectively lower than that before treatment in both groups (P<0.05), and the above indexes of observation group after treatment was respectively lower than that of control group (P<0.05).The level of CD8 +was lower, CD4 +, CD4 +/CD8 +was higher after treatment than that before treatment in both groups, respectively (P<0.05), and the CD8 +level of observation group after treatment was lower, CD4 +, CD4 +/CD8 +was higher than that of control group, respectively (P<0.05).The level of TNF-α, IL-6, CRP after treatment was respectively lower than that before treatment in both groups (P<0.05), and the above indexes of observation group after treatment was respectively lower than that of control group (P<0.05).Conclusion The mixed protamine zinc recombinant human insulin lispro injection can significantly improve glucose metabolism in patients with type 2 diabetes, and enhance immune function, reduce inflammation, thereby reducing the incidence of cardiovascular events.

Result Analysis
Print
Save
E-mail