1.O-arm navigation versus C-arm navigation for guiding percutaneous long sacroiliac screws placement in treatment of Denis type Ⅱ sacral fractures.
Wei ZHOU ; Guodong WANG ; Xuan PEI ; Zhixun FANG ; Yu CHEN ; Suyaolatu BAO ; Jianan CHEN ; Ximing LIU
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):28-34
OBJECTIVE:
To compare the effectiveness of O-arm navigation and C-arm navigation for guiding percutaneous long sacroiliac screws in treatment of Denis type Ⅱ sacral fractures.
METHODS:
A retrospective study was conducted on clinical data of the 46 patients with Denis type Ⅱ sacral fractures between April 2021 and October 2022. Among them, 19 patients underwent O-arm navigation assisted percutaneous long sacroiliac screw fixation (O-arm navigation group), and 27 patients underwent C-arm navigation assisted percutaneous long sacroiliac screw fixation (C-arm navigation group). There was no significant difference in gender, age, causes of injuries, Tile classification of pelvic fractures, combined injury, the interval from injury to operation between the two groups ( P>0.05). The intraoperative preparation time, the placement time of each screw, the fluoroscopy time of each screw during placement, screw position accuracy, the quality of fracture reduction, and fracture healing time were recorded and compared, postoperative complications were observed. Pelvic function was evaluated by Majeed score at last follow-up.
RESULTS:
All operations were completed successfully, and all incisions healed by first intention. Compared to the C-arm navigation group, the O-arm navigation group had shorter intraoperative preparation time, placement time of each screw, and fluoroscopy time, with significant differences ( P<0.05). There was no significant difference in screw position accuracy and the quality of fracture reduction ( P>0.05). There was no nerve or vascular injury during screw placed in the two groups. All patients in both groups were followed up, with the follow-up time of 6-21 months (mean, 12.0 months). Imaging re-examination showed that both groups achieved bony healing, and there was no significant difference in fracture healing time between the two groups ( P>0.05). During follow-up, there was no postoperative complications, such as screw loosening and breaking or loss of fracture reduction. At last follow-up, there was no significant difference in pelvic function between the two groups ( P>0.05).
CONCLUSION
Compared with the C-arm navigation, the O-arm navigation assisted percutaneous long sacroiliac screws for the treatment of Denis typeⅡsacral fractures can significantly shorten the intraoperative preparation time, screw placement time, and fluoroscopy time, improve the accuracy of screw placement, and obtain clearer navigation images.
Humans
;
Fracture Fixation, Internal/methods*
;
Retrospective Studies
;
Imaging, Three-Dimensional
;
Bone Screws
;
Surgery, Computer-Assisted
;
Tomography, X-Ray Computed
;
Spinal Fractures/surgery*
;
Fractures, Bone/surgery*
;
Pelvic Bones/injuries*
;
Postoperative Complications
;
Neck Injuries
3.Post-tuberculosis lung disease and chronic obstructive pulmonary disease.
Xiaoyan GAI ; Brian ALLWOOD ; Yongchang SUN
Chinese Medical Journal 2023;136(16):1923-1928
The burden of chronic airway diseases, including chronic obstructive pulmonary disease (COPD), continues to increase, especially in low- and middle-income countries. Post-tuberculosis lung disease (PTLD) is characterized by chronic lung changes after the "cure" of pulmonary tuberculosis (TB), which may be associated with the pathogenesis of COPD. However, data on its prevalence, clinical manifestations, computed tomography features, patterns of lung function impairment, and influencing factors are limited. The pathogenic mechanisms underlying PTLD remain to be elucidated. This review summarizes the recent advances in PTLD and TB-associated COPD. Research is urgently needed both for the prevention and management of PTLD.
Humans
;
Pulmonary Disease, Chronic Obstructive
;
Tuberculosis, Pulmonary/complications*
;
Asthma
;
Tomography, X-Ray Computed/methods*
;
Lung
4.Sex Estimation of Han Adults in Western China Based on Three-Dimensional Cranial CT Reconstruction.
Xiao-Tong YANG ; Cheng-Hui SUN ; Yong-Gang MA ; Yong-Jie CAO ; Jian XIONG ; Ji ZHANG ; Ping HUANG
Journal of Forensic Medicine 2023;39(1):27-33
OBJECTIVES:
To examine the reliability and accuracy of Walker's model for estimating the sex of Han adults in western China by using cranium three-dimensional (3D) CT reconstruction, and to study the suitable cranial sex estimation model for Han people in western China.
METHODS:
A total of 576 cranial CT 3D reconstructed images from Hanzhong Hospital in Shaanxi Province from 2017 to 2021 were collected. These images were divided into the experimental group with 486 samples and the validation group with 90 samples. Walker's model was used by observer 1 to estimate the sex of experimental group samples. The logistic function applicable to Han people in western China was corrected by observer 1. The 90 samples in the validation group were scored and substituted into the modified logistic function to complete the back substitution test by observer 1, 2 and 3.
RESULTS:
The accuracy of sex estimation of Han adults in western China was 63.2%-77.2% by applying Walker's model. The accuracy of modified logistic function was 82.9%. The accuracy of sex estimation through back substitution test by 3 observers was 75.6%-91.1%, with a Kappa value of 0.689 (P<0.05) for inter-observer consistency and 0.874 (P<0.05) for intra-observer consistency.
CONCLUSIONS
There are great differences in bone characteristics among people from different regions. The modified logistic function can achieve higher accuracy in Han adults in western China.
Humans
;
Adult
;
Reproducibility of Results
;
Sex Determination by Skeleton/methods*
;
Forensic Anthropology
;
Skull/anatomy & histology*
;
Imaging, Three-Dimensional
;
China
;
Tomography, X-Ray Computed
5.Application value of CT examination of lymph node short diameter in evaluating cardia-left gastric lymph node metastasis in thoracic esophageal squamous cell carcinoma.
Zhen Xuan LI ; Xian Ben LIU ; Yin LI ; Guang Hui LIANG ; Zong Fei WANG ; Yan ZHENG ; Hai Bo SUN ; Wei WANG ; Tao SONG ; Wen Qun XING
Chinese Journal of Oncology 2023;45(11):962-966
Objective: To investigate the application value of computed tomography (CT) examination of lymph node short diameter in evaluating cardia-left gastric lymph node metastasis in thoracic esophageal squamous cell carcinoma (ESCC). Methods: A total of 477 patients with primary thoracic ESCC who underwent surgical treatment in the Affiliated Cancer Hospital of Zhengzhou University from January 2013 to December 2017 were collected. All of them underwent McKeown esophagectomy plus complete two-field or three-field lymph node dissection. Picture archiving and communication system were used to measure the largest cardia-left gastric lymph node short diameter in preoperative CT images. The postoperative pathological diagnosis results of cardia-left gastric lymph node were used as the gold standard. Receiver operating characteristic (ROC) curve was used to evaluate the efficacy of CT lymph node short diameter in detecting the metastasis of cardia-left gastric lymph node in thoracic ESCC, and determine the optimal cut-off value. Results: The median short diameter of the largest cardia-left gastric lymph node was 4.1 mm in 477 patients, and the largest cardia-left gastric lymph node short diameter was less than 3 mm in 155 cases (32.5%). Sixty-eight patients had cardia-left gastric lymph node metastases, of which 38 had paracardial node metastases and 41 had left gastric node metastases. The lymph node ratios of paracardial node and left gastric node were 4.0% (60/1 511) and 3.3% (62/1 887), respectively. ROC curve analysis showed that the area under the curve of CT lymph node short diameter for evaluating cardia-left gastric lymph node metastasis was 0.941 (95% CI: 0.904-0.977; P<0.05). The optimal cut-off value of CT examination of the cardia-left gastric lymph node short diameter was 6 mm, and the corresponding sensitivity, specificity and accuracy were 85.3%, 91.7%, and 90.8%, respectively. Conclusion: CT examination of lymph node short diameter can be a good evaluation of cardia-left gastric lymph node metastasis in thoracic ESCC, and the optimal cut-off value is 6 mm.
Humans
;
Esophageal Squamous Cell Carcinoma/pathology*
;
Cardia/surgery*
;
Esophageal Neoplasms/pathology*
;
Lymphatic Metastasis/pathology*
;
Lymph Nodes/pathology*
;
Lymph Node Excision
;
Tomography, X-Ray Computed/methods*
;
Esophagectomy/methods*
;
Retrospective Studies
6.Attach importance to the moderate diagnosis and treatment of multiple pulmonary nodules.
Ning Xin CUI ; Lin YE ; Jia Yuan SUN
Chinese Journal of Preventive Medicine 2023;57(8):1181-1185
With the popularization of chest computed tomography examination in physical examination, the detection rate of multiple pulmonary nodules has significantly increased. However, there are no unified guidelines or consensus for the diagnosis and treatment of multiple pulmonary nodules, and the clinical diagnosis and treatment of such patients are often inadequate or excessive. Therefore, it is of great clinical significance to attach importance to the moderate diagnosis and treatment of multiple pulmonary nodules and formulate unified clinical practice standards for the prevention of lung cancer and the diagnosis and treatment of multiple pulmonary nodules.
Humans
;
Multiple Pulmonary Nodules/therapy*
;
Lung Neoplasms/therapy*
;
Tomography, X-Ray Computed/methods*
7.Contrast-enhanced ultrasound and contrast-enhanced computed tomography for differentiating mass-forming pancreatitis from pancreatic ductal adenocarcinoma: a meta-analysis.
Jie YANG ; Jiayan HUANG ; Yonggang ZHANG ; Keyu ZENG ; Min LIAO ; Zhenpeng JIANG ; Wuyongga BAO ; Qiang LU
Chinese Medical Journal 2023;136(17):2028-2036
BACKGROUND:
Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC.
METHODS:
A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance.
RESULTS:
Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2 = 0.00%) and 95% (95% CI, 90%-97%; I2 = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2 = 66.37%) and 94% (95% CI, 90-96%; I2 = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P > 0.05).
CONCLUSIONS
CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.
Humans
;
Contrast Media
;
Bayes Theorem
;
Tomography, X-Ray Computed/methods*
;
Pancreatic Neoplasms/diagnostic imaging*
;
Carcinoma, Pancreatic Ductal/diagnostic imaging*
;
Sensitivity and Specificity
;
Pancreatitis/diagnostic imaging*
;
Ultrasonography/methods*
8.Effect of arteriosclerotic intracranial arterial vessel wall enhancement on downstream collateral flow.
Liqun YAN ; Jin YAN ; Zhenchang WANG ; Guoshi WANG ; Zhenzhong LI ; Yaping HOU ; Boyuan HUANG ; Qianbo DONG ; Xiaodan MU ; Wei CAO ; Pengfei ZHAO
Chinese Medical Journal 2023;136(18):2221-2228
BACKGROUND:
The effect of arteriosclerotic intracranial arterial vessel wall enhancement (IAVWE) on downstream collateral flow found in vessel wall imaging (VWI) is not clear. Regardless of the mechanism underlying IAVWE on VWI, damage to the patient's nervous system caused by IAVWE is likely achieved by affecting downstream cerebral blood flow. The present study aimed to investigate the effect of arteriosclerotic IAVWE on downstream collateral flow.
METHODS:
The present study recruited 63 consecutive patients at the Second Hospital of Hebei Medical University from January 2021 to November 2021 with underlying atherosclerotic diseases and unilateral middle cerebral artery (MCA) M1-segment stenosis who underwent an magnetic resonance scan within 3 days of symptom onset. The patients were divided into 4 groups according to IAVWE and the stenosis ratio (Group 1, n = 17; Group 2, n = 19; Group 3, n = 13; Group 4, n = 14), and downstream collateral flow was analyzed using three-dimensional pseudocontinuous arterial spin labeling (3D-pCASL) and RAPID software. The National Institutes of Health Stroke Scale (NIHSS) scores of the patients were also recorded. Two-factor multivariate analysis of variance using Pillai's trace was used as the main statistical method.
RESULTS:
No statistically significant difference was found in baseline demographic characteristics among the groups. IAVWE, but not the stenosis ratio, had a statistically significant significance on the late-arriving retrograde flow proportion (LARFP), hypoperfusion intensity ratio (HIR), and NIHSS scores ( F = 20.941, P <0.001, Pillai's trace statistic = 0.567). The between-subject effects test showed that IAVWE had a significant effect on the three dependent variables: LARFP ( R2 = 0.088, F = 10.899, P = 0.002), HIR ( R2 = 0.234, F = 29.354, P <0.001), and NIHSS ( R2 = 114.339, F = 33.338, P <0.001).
CONCLUSIONS:
Arteriosclerotic IAVWE significantly reduced downstream collateral flow and affected relevant neurological deficits. It was an independent factor affecting downstream collateral flow and NIHSS scores, which should be a focus of future studies.
TRIAL REGISTRATION
ChiCTR.org.cn, ChiCTR2100053661.
Humans
;
Constriction, Pathologic/pathology*
;
Magnetic Resonance Imaging/methods*
;
Middle Cerebral Artery/pathology*
;
Tomography, X-Ray Computed
9.Model construction and software design of computed tomography radiation system based on visualization.
Ying LIU ; Ting MENG ; Haowei ZHANG ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):989-995
The Monte Carlo N-Particle (MCNP) is often used to calculate the radiation dose during computed tomography (CT) scans. However, the physical calculation process of the model is complicated, the input file structure of the program is complex, and the three-dimensional (3D) display of the geometric model is not supported, so that the researchers cannot establish an accurate CT radiation system model, which affects the accuracy of the dose calculation results. Aiming at these two problems, this study designed a software that visualized CT modeling and automatically generated input files. In terms of model calculation, the theoretical basis was based on the integration of CT modeling improvement schemes of major researchers. For 3D model visualization, LabVIEW was used as the new development platform, constructive solid geometry (CSG) was used as the algorithm principle, and the introduction of editing of MCNP input files was used to visualize CT geometry modeling. Compared with a CT model established by a recent study, the root mean square error between the results simulated by this visual CT modeling software and the actual measurement was smaller. In conclusion, the proposed CT visualization modeling software can not only help researchers to obtain an accurate CT radiation system model, but also provide a new research idea for the geometric modeling visualization method of MCNP.
Radiation Dosage
;
Software Design
;
Tomography, X-Ray Computed/methods*
;
Software
;
Algorithms
;
Phantoms, Imaging
;
Monte Carlo Method
10.A comprehensive review on photon-counting computed tomography: Principles, technical hurdles and analysis of clinical applications.
Haowei ZHANG ; Shuhan LI ; Ying LIU ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):1012-1018
In recent years, photon-counting computed tomography (PCD-CT) based on photon-counting detectors (PCDs) has become increasingly utilized in clinical practice. Compared with conventional CT, PCD-CT has the potential to achieve micron-level spatial resolution, lower radiation dose, negligible electronic noise, multi-energy imaging, and material identification, etc. This advancement facilitates the promotion of ultra-low dose scans in clinical scenarios, potentially detecting minimal and hidden lesions, thus significantly improving image quality. However, the current state of the art is limited and issues such as charge sharing, pulse pileup, K-escape and count rate drift remain unresolved. These issues could lead to a decrease in image resolution and energy resolution, while an increasing in image noise and ring artifact and so on. This article systematically reviewed the physical principles of PCD-CT, and outlined the structural differences between PCDs and energy integration detectors (EIDs), and the current challenges in the development of PCD-CT. In addition, the advantages and disadvantages of three detector materials were analysed. Then, the clinical benefits of PCD-CT were presented through the clinical application of PCD-CT in the three diseases with the highest mortality rate in China (cardiovascular disease, tumour and respiratory disease). The overall aim of the article is to comprehensively assist medical professionals in understanding the technological innovations and current technical limitations of PCD-CT, while highlighting the urgent problems that PCD-CT needs to address in the coming years.
Tomography, X-Ray Computed/methods*
;
Photons
;
Noise
;
China
;
Phantoms, Imaging

Result Analysis
Print
Save
E-mail