1.Effect of graphene-oxide-modified osteon-like concentric microgrooved surface on the osteoclastic differentiation of macrophages.
Hong WANG ; Qinglin WU ; Yingzhen LAI ; Yihuang CAI
West China Journal of Stomatology 2023;41(2):165-174
		                        		
		                        			OBJECTIVES:
		                        			This study aimed to investigate the effect of new biomimetic micro/nano surfaces on the osteoclastic differentiation of RAW264.7 macrophages by simulating natural osteons for the design of concentric circular structures and modifying graphene oxide (GO).
		                        		
		                        			METHODS:
		                        			The groups were divided into smooth titanium surface group (SS), concentric microgrooved titanium surface group (CMS), and microgroove modified with GO group (GO-CMS). The physicochemical properties of the material surfaces were studied using scanning electron microscopy (SEM), contact-angle measurement, atomic force microscopy, X-ray photoelectron spectroscopy analysis, and Raman spectroscopy. The effect of the modified material surface on the cell biological behavior of RAW264.7 was investigated by cell-activity assay, SEM, and laser confocal microscopy. The effect on the osteoclastic differentiation of macrophages was investiga-ted by tartrate-resistant acid phosphatase (TRAP) immunofluorescence staining and quantitative real-time polymerase chain reaction (qRT-PCR) experiments.
		                        		
		                        			RESULTS:
		                        			Macrophages were arranged in concentric circles along the microgrooves, and after modification with GO, the oxygen-containing groups on the surface of the material increased and hydrophilicity increased. Osteoclasts in the GO-CMS group were small in size and number and had the lowest TRAP expression. Although it promoted the proliferation of macrophages in the GO-CMS group, the expression of osteoclastic differentiation-related genes was lower than that in the SS group, and the difference was statistically significant (P<0.05).
		                        		
		                        			CONCLUSIONS
		                        			Concentric circular microgrooves restricted the fusion of osteoclasts and the formation of sealing zones. Osteomimetic concentric microgrooves modified with GO inhibited the osteoclastic differentiation of RAW 264.7 macrophages.
		                        		
		                        		
		                        		
		                        			Graphite/pharmacology*
		                        			;
		                        		
		                        			Titanium/pharmacology*
		                        			;
		                        		
		                        			Haversian System
		                        			;
		                        		
		                        			Macrophages
		                        			;
		                        		
		                        			Cell Differentiation
		                        			;
		                        		
		                        			Oxides/pharmacology*
		                        			;
		                        		
		                        			Surface Properties
		                        			
		                        		
		                        	
2.In vitro research of oral microscope-assisted implant surface decontamination.
Wenqi SU ; Jingwen LI ; Lishan JIANG ; Wenjie CUI ; Yang ZHAO ; Houxuan LI
West China Journal of Stomatology 2023;41(3):350-355
		                        		
		                        			OBJECTIVES:
		                        			To investigate the effect of oral microscope-assisted surface decontamination on implants in vitro.
		                        		
		                        			METHODS:
		                        			Twelve implants that fell off because of severe peri-implantitis were collected, and decontamination was carried out on the surfaces of implants through curetting, ultrasound, titanium brushing, and sandblasting at 1×, 8×, or 12.8× magnifications. The number and sizes of residues on the implants' surfaces after decontamination were determined, and the decontamination effect was analyzed according to the thread spacing in the different parts of the thread.
		                        		
		                        			RESULTS:
		                        			1) The 8× and 12.8× groups scored lower for implant surface residues than the 1× group (P<0.000 1), and the 12.8× group scored lower than the 8× group (P<0.001); 2) no difference in residue score was found between the wide and narrow thread pitch (P>0.05), and the 8× and 12.8× groups had lower scores than the 1× group (P<0.001); 3) the lowest number of contaminants was observed at the tip of the thread, whereas the highest was observed below the thread, and the difference was significant (P<0.001). However, the thread pitch had no effect on the number of contaminants in different areas (P>0.05); 4) the residue scores of the 8× and 12.8× groups were lower than those of the 1× group at the thread tip and above, sag, and below the thread of the implants (P<0.05).
		                        		
		                        			CONCLUSIONS
		                        			Residues on the surfaces of contaminated implants can be effectively removed by using an oral microscope. After decontamination, the residues of pollutants were mainly concentrated below the thread of the implants, and the thread pitch of the implants had no significant effect on the residues.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Dental Implants
		                        			;
		                        		
		                        			Decontamination
		                        			;
		                        		
		                        			Surface Properties
		                        			;
		                        		
		                        			Peri-Implantitis
		                        			;
		                        		
		                        			Titanium
		                        			
		                        		
		                        	
3.Surgical technique and effectiveness of titanium elastic nail assisted retrograde channel screw implantation in superior pubic branch.
Xiaotian CHEN ; Xiaopan WANG ; Peishuai ZHAO ; Renjie LI ; Junliang JIA ; Min WU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):431-437
		                        		
		                        			OBJECTIVE:
		                        			To investigate the surgical technique and effectiveness of titanium elastic nail (TEN) assisted retrograde channel screw implantation of superior pubic branch.
		                        		
		                        			METHODS:
		                        			The clinical data of 31 patients with pelvic or acetabular fractures treated with retrograde channel screw implantation in superior pubic branch between January 2021 and April 2022 were retrospectively analyzed. Among them, 16 cases were implanted with assistance of TEN (study group) and 15 cases were implanted under the guidance of C-arm X-ray machine (control group). There was no significant difference in gender, age, cause of injury, Tile classification of pelvic fracture, Judet-Letournal classification of acetabular fracture, and time from injury to operation between the two groups ( P>0.05). The operation time, fluoroscopy times, and intraoperative blood loss of each superior pubic branch retrograde channel screw were recorded during operation. X-ray films and three-dimensional CT were reexamined after operation, the quality of fracture reduction was evaluated by Matta score standard, and the position of channel screw was evaluated by screw position classification standard. The fracture healing time was recorded during the follow-up, and the postoperative functional recovery was evaluated by Merle D'Aubigne Postel score system at last follow-up.
		                        		
		                        			RESULTS:
		                        			Nineteen and 20 retrograde channel screws of superior pubic branch were implanted in the study group and the control group, respectively. The operation time, fluoroscopy times, and intraoperative blood loss of each screw in the study group were significantly less than those in the control group ( P<0.05). According to the postoperative X-ray films and three-dimensional CT, none of the 19 screws in the study group penetrated out of the cortical bone or into the joint, and the excellent and good rate was 100% (19/19); in the control group, there were 4 screws of cortical bone penetration, and the excellent and good rate was 80% (16/20); the difference between the two groups was significant ( P<0.05). Matta score standard was used to evaluate the quality of fracture reduction, there was no patient in the two groups with poor reduction results, and the difference was not significant between the two groups ( P>0.05). The incisions of the two groups healed by first intention, and there was no complication such as incision infection, skin margin necrosis, and deep infection. All patients were followed up 8-22 months, with an average of 14.7 months. There was no significant difference in healing time between the two groups ( P>0.05). At last follow-up, the difference in functional recovery evaluated by the Merle D'Aubigne Postel scoring system between the two groups was not significant ( P>0.05).
		                        		
		                        			CONCLUSION
		                        			TEN assisted implantation technique can significantly shorten the operation time of retrograde channel screw implantation of superior pubic branch, reduce the times of fluoroscopy, and have less intraoperative blood loss and accurate screw implantation, which provides a new safe and reliable method for minimally invasive treatment of pelvic and acetabular fractures.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Titanium
		                        			;
		                        		
		                        			Fracture Fixation, Internal/methods*
		                        			;
		                        		
		                        			Blood Loss, Surgical
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Bone Screws
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Fractures, Bone/surgery*
		                        			;
		                        		
		                        			Spinal Fractures
		                        			;
		                        		
		                        			Hip Fractures
		                        			
		                        		
		                        	
4.Three-dimensional finite element model construction and biomechanical analysis of customized titanium alloy lunate prosthesis.
Bin WANG ; Xingbo CAI ; Yue ZHANG ; Bihuan ZHANG ; Yongqing XU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):821-826
		                        		
		                        			OBJECTIVE:
		                        			To design customized titanium alloy lunate prosthesis, construct three-dimensional finite element model of wrist joint before and after replacement by finite element analysis, and observe the biomechanical changes of wrist joint after replacement, providing biomechanical basis for clinical application of prosthesis.
		                        		
		                        			METHODS:
		                        			One fresh frozen human forearm was collected, and the maximum range of motions in flexion, extension, ulnar deviation, and radialis deviation tested by cortex motion capture system were 48.42°, 38.04°, 35.68°, and 26.41°, respectively. The wrist joint data was obtained by CT scan and imported into Mimics21.0 software and Magics21.0 software to construct a wrist joint three-dimensional model and design customized titanium alloy lunate prosthesis. Then Geomagic Studio 2017 software and Solidworks 2017 software were used to construct the three-dimensional finite element models of a normal wrist joint (normal model) and a wrist joint with lunate prosthesis after replacement (replacement model). The stress distribution and deformation of the wrist joint before and after replacement were analyzed for flexion at and 15°, 30°, 48.42°, extension at 15°, 30°, and 38.04°, ulnar deviation at 10°, 20°, and 35.68°, and radial deviation at 5°, 15°, and 26.41° by the ANSYS 17.0 finite element analysis software. And the stress distribution of lunate bone and lunate prosthesis were also observed.
		                        		
		                        			RESULTS:
		                        			The three-dimensional finite element models of wrist joint before and after replacement were successfully constructed. At different range of motion of flexion, extension, ulnar deviation, and radial deviation, there were some differences in the number of nodes and units in the grid models. In the four directions of flexion, extension, ulnar deviation, and radial deviation, the maximum deformation of wrist joint in normal model and replacement model occurred in the radial side, and the values increased gradually with the increase of the range of motion. The maximum stress of the wrist joint increased gradually with the increase of the range of motion, and at maximum range of motion, the stress was concentrated on the proximal radius, showing an overall trend of moving from the radial wrist to the proximal radius. The maximum stress of normal lunate bone increased gradually with the increase of range of motion in different directions, and the stress position also changed. The maximum stress of lunate prosthesis was concentrated on the ulnar side of the prosthesis, which increased gradually with the increase of the range of motion in flexion, and decreased gradually with the increase of the range of motion in extension, ulnar deviation, and radialis deviation. The stress on prosthesis increased significantly when compared with that on normal lunate bone.
		                        		
		                        			CONCLUSION
		                        			The customized titanium alloy lunate prosthesis does not change the wrist joint load transfer mode, which provided data support for the clinical application of the prosthesis.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Lunate Bone/surgery*
		                        			;
		                        		
		                        			Finite Element Analysis
		                        			;
		                        		
		                        			Titanium
		                        			;
		                        		
		                        			Wrist Joint/surgery*
		                        			;
		                        		
		                        			Artificial Limbs
		                        			;
		                        		
		                        			Range of Motion, Articular
		                        			;
		                        		
		                        			Biomechanical Phenomena
		                        			
		                        		
		                        	
5.Metal artifact reduction and clinical verification in oral and maxillofacial region based on deep learning.
Wei ZENG ; Shan Luo ZHOU ; Ji Xiang GUO ; Wei TANG
Chinese Journal of Stomatology 2023;58(6):540-546
		                        		
		                        			
		                        			Objective: To construct a kind of neural network for eliminating the metal artifacts in CT images by training the generative adversarial networks (GAN) model, so as to provide reference for clinical practice. Methods: The CT data of patients treated in the Department of Radiology, West China Hospital of Stomatology, Sichuan University from January 2017 to June 2022 were collected. A total of 1 000 cases of artifact-free CT data and 620 cases of metal artifact CT data were obtained, including 5 types of metal restorative materials, namely, fillings, crowns, titanium plates and screws, orthodontic brackets and metal foreign bodies. Four hundred metal artifact CT data and 1 000 artifact-free CT data were utilized for simulation synthesis, and 1 000 pairs of simulated artifacts and metal images and simulated metal images (200 pairs of each type) were constructed. Under the condition that the data of the five metal artifacts were equal, the entire data set was randomly (computer random) divided into a training set (800 pairs) and a test set (200 pairs). The former was used to train the GAN model, and the latter was used to evaluate the performance of the GAN model. The test set was evaluated quantitatively and the quantitative indexes were root-mean-square error (RMSE) and structural similarity index measure (SSIM). The trained GAN model was employed to eliminate the metal artifacts from the CT data of the remaining 220 clinical cases of metal artifact CT data, and the elimination results were evaluated by two senior attending doctors using the modified LiKert scale. Results: The RMSE values for artifact elimination of fillings, crowns, titanium plates and screws, orthodontic brackets and metal foreign bodies in test set were 0.018±0.004, 0.023±0.007, 0.015±0.003, 0.019±0.004, 0.024±0.008, respectively (F=1.29, P=0.274). The SSIM values were 0.963±0.023, 0.961±0.023, 0.965±0.013, 0.958±0.022, 0.957±0.026, respectively (F=2.22, P=0.069). The intra-group correlation coefficient of 2 evaluators was 0.972. For 220 clinical cases, the overall score of the modified LiKert scale was (3.73±1.13), indicating a satisfactory performance. The scores of modified LiKert scale for fillings, crowns, titanium plates and screws, orthodontic brackets and metal foreign bodies were (3.68±1.13), (3.67±1.16), (3.97±1.03), (3.83±1.14), (3.33±1.12), respectively (F=1.44, P=0.145). Conclusions: The metal artifact reduction GAN model constructed in this study can effectively remove the interference of metal artifacts and improve the image quality.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Tomography, X-Ray Computed/methods*
		                        			;
		                        		
		                        			Deep Learning
		                        			;
		                        		
		                        			Titanium
		                        			;
		                        		
		                        			Neural Networks, Computer
		                        			;
		                        		
		                        			Metals
		                        			;
		                        		
		                        			Image Processing, Computer-Assisted/methods*
		                        			;
		                        		
		                        			Algorithms
		                        			
		                        		
		                        	
6.Effect of various intracanal materials on the diagnostic accuracy of cone-beam computed tomography in vertical root fractures.
Jin Hua ZHANG ; Jie PAN ; Zhi Peng SUN ; Xiao WANG
Journal of Peking University(Health Sciences) 2023;55(2):333-338
		                        		
		                        			OBJECTIVE:
		                        			To study the effect of various intracanal materials on the accuracy of oral maxillofacial cone-beam computed tomography (CBCT) for the diagnosis of vertical root fracture (VRF).
		                        		
		                        			METHODS:
		                        			A total of twenty-four structurally intact single root canal dried and isolated teeth extracted for orthodontic treatment or periodontal disease were collected. The teeth were decrowned along the cemento-enamel junction (CEJ) and then used as samples for the study after conventional root canal preparation and post preparation. The 24 samples were divided into two groups with 12 samples in each group. Group A was the control group (no VRF group). According to intracanal materials, they were divided into five subgroups: blank group, fiber post group, gutta-percha point group, titanium post group and gold-palladium post group. Group B was the experimental group (VRF group), and subgroups were grouped as above. The VRF model was prepared by a unified method in the VRF group: the root was completely fractured in the buccolingual direction with a custom root canal nail and then cemented and reset. The control group was not subjected to the simulation of VRF. Titanium post and gold-palladium post were made according to the individuality of the root canal preparation, and the tightness of the post to the root canal wall was confirmed by X-ray radiograph. Then all the samples were scanned by CBCT in the isolate swine mandibular alveolar sockets. The diagnostic accuracy was statistically analyzed via blind interpretation by experienced endodontic specialists and oral and maxillofacial medical imaging specialists.
		                        		
		                        			RESULTS:
		                        			The accuracy of the diagnosis of VRF in the blank group, fiber post group, gutta-percha point group, titanium post group, and gold-palladium post group in CBCT was 95.83%, 91.67%, 87.50%, 79.17%, and 45.83%, respectively. Compared with the blank group, the differences were not statistically significant in the fiber post group (P>0.999), the gutta-percha point group (P=0.500) and the titanium post group (P=0.125). The lowest diagnostic accuracy of VRF was found in the gold-palladium post group, and the difference was statistically significant compared with all other groups (P < 0.001).
		                        		
		                        			CONCLUSION
		                        			Various intracanal materials have different degrees of influence on the diagnostic accuracy of VRF diagnosis in CBCT. The influence of fiber post, gutta-percha point and titanium post was small, while the influence of gold-palladium post was significant.
		                        		
		                        		
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Cone-Beam Computed Tomography/methods*
		                        			;
		                        		
		                        			Gold
		                        			;
		                        		
		                        			Gutta-Percha
		                        			;
		                        		
		                        			Palladium
		                        			;
		                        		
		                        			Swine
		                        			;
		                        		
		                        			Titanium
		                        			;
		                        		
		                        			Tooth Fractures/diagnostic imaging*
		                        			;
		                        		
		                        			Tooth Root/injuries*
		                        			;
		                        		
		                        			Reproducibility of Results
		                        			
		                        		
		                        	
7.Effects of titanium dioxide nanoparticles on circRNA expression profiles in human hepatocellular carcinoma cells HepG2.
Jia Qi SHI ; Ying MA ; Yi ZHANG ; Zhang Jian CHEN ; Guang JIA
Journal of Peking University(Health Sciences) 2023;55(3):392-399
		                        		
		                        			OBJECTIVE:
		                        			To investigate the effect of titanium dioxide nanoparticles (TiO2 NPs) on the expression profile of circular ribonucleic acid (circRNA) in human hepatocytes through in vitro cell experiments, and to attempt to understand the potential mechanism of hepatotoxicity through bioinformatics analysis.
		                        		
		                        			METHODS:
		                        			TiO2 NPs were characterized from the aspects of particle size, shape and agglomeration state. The cell counting kit-8 (CCK8) was used to detect the cytotoxicity of TiO2 NPs against human hepatocellular carcinoma cells (HepG2) after exposure to 0, 1.56, 3.13, 6.25, 12.5, 25, 50, 100, and 200 mg/L TiO2 NPs for 24 h or 48 h. The cells were treated at doses of 0 mg/L TiO2 NPs (control group) and 100 mg/L TiO2 NPs (treatment group), and collected after exposure for 48 h, and then RNA from the extracted cell samples was collected and sequenced. The differential circRNAs between the control and the TiO2 NPs treatment groups were screened, and then the enrichment pathway of the differential circRNA target gene was analyzed by multivariate statistics. According to the sequencing results, significantly altered genes and important genes in the significant enrichment pathways were screened, and real-time reverse transcription-polymerase chain reaction (real-time RT-PCR) was performed to verify the results.
		                        		
		                        			RESULTS:
		                        			TiO2 NPs were spherical anatase with a hydrated particle size of (323.50±85.44) nm and a Zeta potential of (-21.00±0.72) mV in a serum-free medium. The results of the CCK8 cytotoxicity assay showed that with the increase of TiO2 NPs concentration, cell viability gradually decreased. A total of 11 478 circRNAs were found by RNA sequencing. Compared with the control groups, TiO2 NPs treatment groups (100 mg/L) had a total of 89 differential circRNAs, of which 59 were up-regulated and 30 were down-regulated. Analysis of the Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway showed that the targeted genes of differential circRNAs were mainly enriched in fatty acid degradation, Fanconi anemia pathway, and fatty acid metabolism. The expression levels of circRNA.6730, circRNA.3650 and circRNA.4321 were significantly different between the TiO2 NPs treatment group and the control group, which were consistent with the sequencing results.
		                        		
		                        			CONCLUSION
		                        			TiO2 NPs can induce changes in circRNA expression profile, and epigenetics may play an important role in the mechanism of hepatotoxicity.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			RNA/genetics*
		                        			;
		                        		
		                        			RNA, Circular/genetics*
		                        			;
		                        		
		                        			Carcinoma, Hepatocellular/genetics*
		                        			;
		                        		
		                        			Liver Neoplasms/genetics*
		                        			;
		                        		
		                        			Titanium
		                        			;
		                        		
		                        			Nanoparticles
		                        			;
		                        		
		                        			Chemical and Drug Induced Liver Injury
		                        			;
		                        		
		                        			Fatty Acids
		                        			
		                        		
		                        	
8.Influence of antimicrobial peptide biofunctionalized TiO2 nanotubes on the biological behavior of human keratinocytes and its antibacterial effect.
Yi LI ; Jin Jin WANG ; Yi De HE ; Min XU ; Xin Yan LI ; Bo Ya XU ; Yu Mei ZHANG
Chinese Journal of Stomatology 2023;58(2):165-173
		                        		
		                        			
		                        			Objective: To fabricate TiO2 nanotube material functionalized by antimicrobial peptide LL-37, and to explore its effects on biological behaviors such as adhesion and migration of human keratinocytes (HaCaT) and its antibacterial properties. Methods: The TiO2 nanotube array (NT) was constructed on the surface of polished titanium (PT) by anodization, and the antimicrobial peptide LL-37 was loaded on the surface of TiO2 nanotube (LL-37/NT) by physical adsorption. Three samples were selected by simple random sampling in each group. Surface morphology, roughness, hydrophilicity and release characteristics of LL-37 of the samples were analyzed with a field emission scanning electron microscope, an atomic force microscope, a contact angle measuring device and a microplate absorbance reader. HaCaT cells were respectively cultured on the surface of three groups of titanium samples. Each group had 3 replicates. The morphology of cell was observed by field emission scanning electron microscope. The number of cell adhesion was observed by cellular immunofluorescence staining. Cell counting kit-8 (CCK-8) assay was used to detect cell proliferation. Wound scratch assay was used to observe the migration of HaCaT. The above experiments were used to evaluate the effect of each group on the biological behavior of HaCaT cells. To evaluate their antibacterial effects, Porphyromonas gingivalis (Pg) was respectively inoculated on the surface of three groups of titanium samples. Each group had 3 replicates. The morphology of bacteria was observed by field emission scanning electron microscope. Bacterial viability was determined by live/dead bacterial staining. Results: A uniform array of nanotubes could be seen on the surface of titanium samples in LL-37/NT group, and the top of the tube was covered with granular LL-37. Compared with PT group [the roughness was (2.30±0.18) nm, the contact angle was 71.8°±1.7°], the roughness [(20.40±3.10) and (19.10±4.11) nm] and hydrophilicity (the contact angles were 22.4°±3.1° and 25.3°±2.2°, respectively) of titanium samples increased in NT and LL-37/NT group (P<0.001). The results of in vitro release test showed that the release of antimicrobial peptide LL-37 was characterized by early sudden release (1-4 h) and long-term (1-7 d) slow release. With the immunofluorescence, more cell attachment was found on NT and LL-37/NT than that on PT at the first 0.5 and 2.0 h of culture (P<0.05). The results of CCK-8 showed that there was no significant difference in the proliferation of cells among groups at 1, 3 and 5 days after culture. Wound scratch assay showed that compared with PT and NT group, the cell moved fastest on the surface of titanium samples in LL-37/NT group at 24 h of culture [(96.4±4.9)%] (F=35.55, P<0.001). A monolayer cells could be formed and filled with the scratch in 24 h at LL-37/NT group. The results of bacterial test in vitro showed that compared with the PT group, the bacterial morphology in the NT and LL-37/NT groups was significantly wrinkled, and obvious bacterial rupture could be seen on the surface of titanium samples in LL-37/NT group. The results of bacteria staining showed that the green fluorescence intensity of titanium samples in LL-37/NT group was the lowest in all groups (F=66.54,P<0.001). Conclusions: LL-37/NT is beneficial to the adhesion and migration of HaCaT cells and has excellent antibacterial properties, this provides a new strategy for the optimal design of implant neck materials.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Titanium/chemistry*
		                        			;
		                        		
		                        			Antimicrobial Peptides
		                        			;
		                        		
		                        			Cathelicidins
		                        			;
		                        		
		                        			Sincalide
		                        			;
		                        		
		                        			Anti-Bacterial Agents/pharmacology*
		                        			;
		                        		
		                        			Nanotubes/chemistry*
		                        			;
		                        		
		                        			Dental Materials
		                        			;
		                        		
		                        			Bacteria
		                        			;
		                        		
		                        			Keratinocytes
		                        			;
		                        		
		                        			Surface Properties
		                        			
		                        		
		                        	
9.3D-printed vertebral body in anterior spinal reconstruction after total spondylectomy for patients with cervical chordoma.
Hua ZHOU ; Ren Ji WANG ; Zhong Jun LIU ; Xiao Guang LIU ; Feng Liang WU ; Lei DANG ; Feng WEI
Journal of Peking University(Health Sciences) 2023;55(1):144-148
		                        		
		                        			OBJECTIVE:
		                        			To investigate whether 3D-printed artificial vertebral body can reduce prosthesis subsidence rate for patients with cervical chordomas, through comparing the rates of prosthesis subsidence between 3D printing artificial vertebral body and titanium mesh for anterior spinal reconstruction after total spondylectomy.
		                        		
		                        			METHODS:
		                        			This was a retrospective analysis of patients who underwent surgical treatment for cervical chordoma at our hospital from March 2005 to September 2019. There were nine patients in the group of 3D artificial vertebral body (3D group), and 15 patients in the group of titanium mesh cage (Mesh group). The patients' characteristics and treatment data were extracted from the medical records, including age, gender, CT hounsfield unit of cervical vertebra and surgical information, such as the surgical segments, time and blood loss of surgery, frequency and degree of prosthesis subsidence after surgery. Radiographic observations of prosthesis subsidence during the follow-up, including X-rays, CT, and magnetic resonance imaging were also collected. SPSS 22.0 was used to analysis the data.
		                        		
		                        			RESULTS:
		                        			There was no significant difference between the two groups in gender, age, CT hounsfield unit, surgical segments, time of surgery, blood loss of posterior surgery and total blood loss. Blood loss of anterior surgery was 700 (300, 825) mL in 3D group and 1 500 (750, 2 800) mL in Mesh group (P < 0.05). The prosthesis subsidence during the follow-up, 3 months after surgery, there was significant difference between the two groups in mild prosthesis subsidence (P < 0.05). The vertebral height of the 3D group decreased less than 1 mm in eight cases (no prosthesis subsidence) and more than 1 mm in one case (mild prosthesis subsidence). The vertebral height of the Mesh group decreased less than 1 mm in five cases (no prosthesis subsidence), and more than 1 mm in eight cases (mild prosthesis subsidence). Two patients did not have X-rays in 3 months after surgery. There was a statistically significant difference between the two groups in the prosthesis subsidence rate at the end of 12 months (P < 0.01). The vertebral height of eight cases in the 3D group decreased less than 1 mm (no prosthesis subsidence) and one case more than 3 mm (severe prosthesis subsidence). Four of the 15 cases in the Mesh group decreased less than 1 mm (no prosthesis subsidence), two cases more than 1 mm (mild prosthesis subsidence), and nine cases more than 3 mm (severe prosthesis subsidence). There was a statistically significant difference between the two groups in the prosthesis subsidence rate at the end of 24 months (P < 0.01). The vertebral height of seven cases in the 3D group decreased less than 1 mm (no prosthesis subsidence), one case more than 3 mm (severe prosthesis subsidence), and one case died with tumor. One case in the Mesh group decreased less than 1 mm (no prosthesis subsidence), one case more than 1 mm (mild prosthesis subsidence), 11 case more than 3 mm (severe prosthesis subsidence), one case died with tumor and one lost the follow-up. Moreover, at the end of 12 months and 24 months, there was significant difference between the two groups in severe prosthesis subsidence rate (P < 0.01).
		                        		
		                        			CONCLUSION
		                        			3D-printed artificial vertebral body for anterior spinal reconstruction after total spondylectomy for patients with cervical chordoma can provide reliable spinal stability, and reduce the incidence of prosthesis subsidence after 2-year follow-up.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Chordoma/surgery*
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Vertebral Body
		                        			;
		                        		
		                        			Titanium
		                        			;
		                        		
		                        			Cervical Vertebrae/surgery*
		                        			;
		                        		
		                        			Printing, Three-Dimensional
		                        			;
		                        		
		                        			Spinal Fusion/methods*
		                        			;
		                        		
		                        			Treatment Outcome
		                        			
		                        		
		                        	
10.Dosimetric Impact of Titanium Alloy Implant in Spinal IMRT Plan.
Xiaohui CHEN ; Anjie XU ; Jiayan CHEN ; Weigang HU ; Jiayuan PENG
Chinese Journal of Medical Instrumentation 2023;47(1):110-114
		                        		
		                        			
		                        			The purpose of this study is to establish and apply a correction method for titanium alloy implant in spinal IMRT plan, a corrected CT-density table was revised from normal CT-density table to include the density of titanium alloy implant. Dose distribution after and before correction were calculated and compared to evaluate the dose deviation. Plans were also copied to a spinal cancer simulation phantom. A titanium alloy fixation system for spine was implanted in this phantom. Plans were recalculated and compared with the measurement result. The result of this study shows that the max dose of spinal cord showed significant difference after correction, and the deviation between calculation results and measurement results was reduced after correction. The method for expanding the range CT-density table, which means that the density of titanium alloy was included, can reduce the error in calculation.
		                        		
		                        		
		                        		
		                        			Radiotherapy, Intensity-Modulated/methods*
		                        			;
		                        		
		                        			Titanium
		                        			;
		                        		
		                        			Radiotherapy Dosage
		                        			;
		                        		
		                        			Alloys
		                        			;
		                        		
		                        			Radiometry/methods*
		                        			;
		                        		
		                        			Radiotherapy Planning, Computer-Assisted/methods*
		                        			
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail