1.Clinical application of Visual throat forceps in the removal of hypopharyngeal foreign body.
Zhonghua MENG ; Qirui ZOU ; Zhongcheng XING ; Shangqing ZHOU ; Zhen ZHANG ; Ye WANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2024;38(1):80-82
Objective:To explore the feasibility of using self-made visual throat forceps to remove hypopharyngeal foreign bodies. Methods:The throat forceps were combined with the endoscope and connected to a monitor via a data cable resulting in a visual throat forceps apparatus. This device was utilized to examine and treat the hypopharyngeal foreign bodies. Results:Among 53 patients, foreign bodies were detected in 51,with 48 cases involving hypopharyngeal foreign bodies. All were successfully extracted using the visual throat forceps. Three cases, diagnosed as esophageal foreign bodies by electronic gastroscopy, were treated using the same method. Conclusion:Visual throat forceps can be used to examine the hypopharynx and remove foreign bodies. It has the advantages of simple operation, rapid operation, and high success rate of foreign body removal from the hypopharynx. It is worthy of clinical application.
Humans
;
Hypopharynx/surgery*
;
Pharynx/surgery*
;
Endoscopes
;
Surgical Instruments
;
Foreign Bodies/diagnosis*
3.Endoscopic hand-suturing combined with titanium clips for rectal defects closure after endoscopic submucosal dissection: a pilot study.
Shi Bo SONG ; Li Zhou DOU ; Yong LIU ; Yue Ming ZHANG ; Shun HE ; Gui Qi WANG
Chinese Journal of Oncology 2023;45(8):697-703
Objective: To explore the feasibility of endoscopic hand-suturing (EHS) for rectal defects closure after endoscopic submucosal dissection (ESD), and the clinical practicability of EHS combined with titanium clips. Methods: This is a prospective study performed by two experienced endoscopists from the Cancer Hospital, Chinese Academy of Medical Sciences who had received EHS training in sixporcine gastric ESD defects in vivo before the study. From December 2022 to February 2022, 20 patients with rectal mucosal lesions or submucosal diseases underwent ESD. Then EHS combined with titanium clips was adopted to close the rectal ESD defects. Specifically, we first sutured the defects as much as possible through EHS, then use titanium clips to fix the tail of the suture, and finally use additional titanium clips to close the residual parts of the defects that cannot be sutured. The main observational indicators were complete closure of the wound and delayed bleeding within one month after surgery. Results: In the 20 rectal cases, the size of defects ranged from 2.2 to 3.6 cm, with a median of 2.7 cm. All cases achieved complete closure without delayed bleeding, of which 12 (60.0%) were completely sutured with EHS and 8 (40.0%) required additional titanium clips to achieve complete closure after suturing. Conclusion: EHS technique is feasible and safe for rectum. EHS combined with titanium clips can also effectively close the rectal ESD defects, prevent postoperative delayed bleeding, and may be easier to be implemented in clinical practice.
Humans
;
Rectum/surgery*
;
Endoscopic Mucosal Resection/methods*
;
Pilot Projects
;
Titanium
;
Prospective Studies
;
Surgical Instruments
;
Sutures
;
Treatment Outcome
;
Retrospective Studies
4.Endoscopic hand-suturing combined with titanium clips for rectal defects closure after endoscopic submucosal dissection: a pilot study.
Shi Bo SONG ; Li Zhou DOU ; Yong LIU ; Yue Ming ZHANG ; Shun HE ; Gui Qi WANG
Chinese Journal of Oncology 2023;45(8):697-703
Objective: To explore the feasibility of endoscopic hand-suturing (EHS) for rectal defects closure after endoscopic submucosal dissection (ESD), and the clinical practicability of EHS combined with titanium clips. Methods: This is a prospective study performed by two experienced endoscopists from the Cancer Hospital, Chinese Academy of Medical Sciences who had received EHS training in sixporcine gastric ESD defects in vivo before the study. From December 2022 to February 2022, 20 patients with rectal mucosal lesions or submucosal diseases underwent ESD. Then EHS combined with titanium clips was adopted to close the rectal ESD defects. Specifically, we first sutured the defects as much as possible through EHS, then use titanium clips to fix the tail of the suture, and finally use additional titanium clips to close the residual parts of the defects that cannot be sutured. The main observational indicators were complete closure of the wound and delayed bleeding within one month after surgery. Results: In the 20 rectal cases, the size of defects ranged from 2.2 to 3.6 cm, with a median of 2.7 cm. All cases achieved complete closure without delayed bleeding, of which 12 (60.0%) were completely sutured with EHS and 8 (40.0%) required additional titanium clips to achieve complete closure after suturing. Conclusion: EHS technique is feasible and safe for rectum. EHS combined with titanium clips can also effectively close the rectal ESD defects, prevent postoperative delayed bleeding, and may be easier to be implemented in clinical practice.
Humans
;
Rectum/surgery*
;
Endoscopic Mucosal Resection/methods*
;
Pilot Projects
;
Titanium
;
Prospective Studies
;
Surgical Instruments
;
Sutures
;
Treatment Outcome
;
Retrospective Studies
5.Glasses-free Three Dimensional Endoscopic Display System with Multi-face Detection.
Chinese Journal of Medical Instrumentation 2022;46(1):5-9
The glasses-free three dimensional(3D) endoscopic display system provides the surgeon with the depth information of the minimally invasive surgery scene obtained from the binocular perspective, which can effectively relieve the surgeon's posture fatigue and visual fatigue during the long-term surgery, and assist in the operation of surgical instruments more accurately to reduce the damage to the surrounding tissues of the operation area. However, the glasses-free 3D display device currently has the problem of a narrow optimal viewing zone and easy crosstalk, especially in the surgical teaching application scenario, which performs poorly. In order to overcome the limitation of the narrower field of view, we introduce deep learning algorithms to detect and locate multiple faces, fine-tune the 3D display grating of the endoscope, rearrange pixels, and change the best view area, so that more people can get the best view. The experimental results show that the face detection accuracy of the method is 97.88%, and the detection time is 135 frames/ms, which achieves high accuracy while maintaining real-time performance.
Endoscopes
;
Endoscopy
;
Humans
;
Imaging, Three-Dimensional
;
Minimally Invasive Surgical Procedures
;
Surgical Instruments
6.Design of a New Puncture Needle for Trocar.
Chinese Journal of Medical Instrumentation 2022;46(5):514-516
OBJECTIVE:
To develop a new type of puncture needle for indwelling needle, which can overcome the performance problems of the existing puncture needle, reduce producing cost, and enhance clinical operability.
METHODS:
In this design, solid needle thread is used to replace the traditional hollow pipe thread, three cutting edges are used to replace the existing two cutting edges, and the shaft edge form (the needle tip is on the needle thread's axis) is used to replace the original back blade or edge blade; the slot on the side of the solid core wire is used to replace the hollow and side hole on the traditional pipe. Finally, a new solid core puncture needle is formed by a section of solid core steel wire with a spiral groove, the cross-section of which is a circular slotted needle with a triangular shape at one end. Through the comparative analysis of stiffness mutation and puncture force in the experiment, the characteristics and advantages of new puncture needle are reflected.
RESULTS:
The new solid core needle can meet the need of puncture in the course of treatment, and can avoid the potential risk caused by the rigidity mutation of the needle used in the traditional indwelling needle, at the same time, it also has the space to reduce the demand of needle diameter, that means it has the potential to develop smaller needle products.
CONCLUSIONS
The new type of trocar puncture needle, from hollow to solid core, can not only meet the basic requirements of puncture and observation of blood return, but also can avoid the risk of traditional puncture needle due to stiffness mutation, the utility model also has the advantages of better performance (less puncture force) and larger expansion space.
Needles
;
Punctures
;
Steel
;
Surgical Instruments
8.Feasibility, efficacy and safety of transbrachial access for interventional therapy on paravalvular leak post surgical valve replacement.
Hui ZHANG ; Hai Bo HU ; Jian Hua LYU ; Rui Gang XIE ; Kun Jing PANG ; Yao LIU ; Liang XU ; Xiang Bin PAN
Chinese Journal of Cardiology 2021;49(5):467-473
Objective: To investigate the feasibility, efficacy and safety of transbrachial access for interventional therapy on prosthetic paravalvular leak (PVL) post surgical valve replacement. Methods: This is a retrospective study. Patients with PVL after surgical valve replacement who underwent interventional therapy via the brachial artery approach in Structural heart disease center of Fuwai hospital between August 2017 and October 2019, were included. All patients underwent puncture of the brachial artery under local anesthesia, angiography and transcatheter closure procedure were performed. The procedure was performed under transthoracic echocardiography (TTE) guidance. Baseline data, operation data and pre-and post-operative TTE examination results were collected and analyzed. Postoperative complications were recorded and operational adverse events were obtained during follow up in the outpatient department after discharge. The operation success rate was calculated, which was defined as the degree of perivalvular regurgitation decrease by 1 grade and above according to TTE without interfering the valve movement and coronary artery blood flow within 30 days after occluder placement. Results: A total of 10 patients were enrolled in this study, the mean age was (57.5±14.6) years, and 6 patients were males. There were 7 cases with aortic PVL, and 3 cases with mitral PVL. Except for one patient who was converted to the femoral vein-transseptal approach, the other 9 patients were successfully implanted with the devices via the brachial artery approach. The operation time was (103.3±34.0) minutes, and there was no need for rigorous bed rest after the operation. The median hospital stay was 7.5 (3.0, 9.8) days. The operation success rate was 9/10 via the brachial artery approach. The differences in the degree of perivalvular regurgitation, New York Heart Association (NYHA) classification, left ventricular end diastolic diameter and left atrial diameter before and after operation were statistically significant (all P<0.05). One case developed new hemolysis with renal insufficiency on the second day after procedure and discharged after successful dialysis. Another case experienced complication of brachial artery pseudoaneurysm after procedure and discharged after successful treatment with thrombin injection. The mean follow-up time was (14.3±7.9) months. During the follow-up, NYHA classification remained as Ⅰ/Ⅱ in 9 patients, no operational adverse events were observed. Conclusions: Transbrachial access for interventional therapy on PVL post surgical valve replacement is a feasible, effective, and safe procedure. It has the advantages of simplifying the operation process and reducing postoperative bed rest time.
Adult
;
Aged
;
Aortic Valve/surgery*
;
Cardiac Catheterization
;
Feasibility Studies
;
Female
;
Heart Valve Prosthesis
;
Heart Valve Prosthesis Implantation/adverse effects*
;
Humans
;
Male
;
Middle Aged
;
Retrospective Studies
;
Surgical Instruments
;
Treatment Outcome
10.Development of Gun-type Tube-Guide Device of Laser Fiber.
Wenyao DENG ; Changding HE ; Jinchao YU ; Jun SHAO
Chinese Journal of Medical Instrumentation 2020;44(6):491-494
With the development of laryngeal microsurgery, the requirements for the flexibility and convenience of surgical instruments are increasing. The research on related instruments has important value for the clinical application of laryngeal microsurgery. We have redesigned a gun-type tube-guide device of laser fiber by comparing the shortcomings of existing laser fiber introducers. The innovation of this design lies in its rotating nut device with adjustable laser angle and pre-bent tip. The corresponding
Humans
;
Larynx/surgery*
;
Laser Therapy/instrumentation*
;
Lasers
;
Microsurgery/instrumentation*
;
Surgical Instruments

Result Analysis