1.O-arm navigation versus C-arm navigation for guiding percutaneous long sacroiliac screws placement in treatment of Denis type Ⅱ sacral fractures.
Wei ZHOU ; Guodong WANG ; Xuan PEI ; Zhixun FANG ; Yu CHEN ; Suyaolatu BAO ; Jianan CHEN ; Ximing LIU
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):28-34
OBJECTIVE:
To compare the effectiveness of O-arm navigation and C-arm navigation for guiding percutaneous long sacroiliac screws in treatment of Denis type Ⅱ sacral fractures.
METHODS:
A retrospective study was conducted on clinical data of the 46 patients with Denis type Ⅱ sacral fractures between April 2021 and October 2022. Among them, 19 patients underwent O-arm navigation assisted percutaneous long sacroiliac screw fixation (O-arm navigation group), and 27 patients underwent C-arm navigation assisted percutaneous long sacroiliac screw fixation (C-arm navigation group). There was no significant difference in gender, age, causes of injuries, Tile classification of pelvic fractures, combined injury, the interval from injury to operation between the two groups ( P>0.05). The intraoperative preparation time, the placement time of each screw, the fluoroscopy time of each screw during placement, screw position accuracy, the quality of fracture reduction, and fracture healing time were recorded and compared, postoperative complications were observed. Pelvic function was evaluated by Majeed score at last follow-up.
RESULTS:
All operations were completed successfully, and all incisions healed by first intention. Compared to the C-arm navigation group, the O-arm navigation group had shorter intraoperative preparation time, placement time of each screw, and fluoroscopy time, with significant differences ( P<0.05). There was no significant difference in screw position accuracy and the quality of fracture reduction ( P>0.05). There was no nerve or vascular injury during screw placed in the two groups. All patients in both groups were followed up, with the follow-up time of 6-21 months (mean, 12.0 months). Imaging re-examination showed that both groups achieved bony healing, and there was no significant difference in fracture healing time between the two groups ( P>0.05). During follow-up, there was no postoperative complications, such as screw loosening and breaking or loss of fracture reduction. At last follow-up, there was no significant difference in pelvic function between the two groups ( P>0.05).
CONCLUSION
Compared with the C-arm navigation, the O-arm navigation assisted percutaneous long sacroiliac screws for the treatment of Denis typeⅡsacral fractures can significantly shorten the intraoperative preparation time, screw placement time, and fluoroscopy time, improve the accuracy of screw placement, and obtain clearer navigation images.
Humans
;
Fracture Fixation, Internal/methods*
;
Retrospective Studies
;
Imaging, Three-Dimensional
;
Bone Screws
;
Surgery, Computer-Assisted
;
Tomography, X-Ray Computed
;
Spinal Fractures/surgery*
;
Fractures, Bone/surgery*
;
Pelvic Bones/injuries*
;
Postoperative Complications
;
Neck Injuries
2.Multiresolution discrete optimization registration method of ultrasound and magnetic resonance images based on key points.
Journal of Biomedical Engineering 2023;40(2):202-207
The registration of preoperative magnetic resonance (MR) images and intraoperative ultrasound (US) images is very important in the planning of brain tumor surgery and during surgery. Considering that the two-modality images have different intensity range and resolution, and the US images are degraded by lots of speckle noises, a self-similarity context (SSC) descriptor based on local neighborhood information was adopted to define the similarity measure. The ultrasound images were considered as the reference, the corners were extracted as the key points using three-dimensional differential operators, and the dense displacement sampling discrete optimization algorithm was adopted for registration. The whole registration process was divided into two stages including the affine registration and the elastic registration. In the affine registration stage, the image was decomposed using multi-resolution scheme, and in the elastic registration stage, the displacement vectors of key points were regularized using the minimum convolution and mean field reasoning strategies. The registration experiment was performed on the preoperative MR images and intraoperative US images of 22 patients. The overall error after affine registration was (1.57 ± 0.30) mm, and the average computation time of each pair of images was only 1.36 s; while the overall error after elastic registration was further reduced to (1.40 ± 0.28) mm, and the average registration time was 1.53 s. The experimental results show that the proposed method has prominent registration accuracy and high computational efficiency.
Humans
;
Imaging, Three-Dimensional/methods*
;
Magnetic Resonance Imaging/methods*
;
Ultrasonography/methods*
;
Algorithms
;
Surgery, Computer-Assisted/methods*
3.Current application and prospect of accurate navigation technology in orthopaedic trauma.
Hong Ru MA ; Zi Tao ZHANG ; Jun JIANG ; Feng Feng LI ; Yong QIU
Chinese Journal of Surgery 2023;61(1):23-28
In the past decades,a dramatic development of navigation technology in orthopaedic surgery has been witnessed. By assisting the localization of surgical region,verification of target bony structure,preoperative planning of fixation,intraoperative identification of planned entry point and direction of instruments or even automated insertion of implants,its ability and potential to reduce operation time,intraoperative radiation,surgical trauma,and improve accuracy has been proved. However,in contrast to the widespread use of navigation technology in arthroplasty,orthopaedic tumor,and spine surgery,its application in orthopaedic trauma is relatively less. In this manuscript,the main purpose is to introduce the technical principles of navigation devices,outline the current clinical application of navigation systems in orthopaedic trauma,analyze the current challenges confronting its further application in clinical practice and its prospect in the future.
Humans
;
Orthopedics
;
Surgery, Computer-Assisted/methods*
;
Orthopedic Procedures/methods*
;
Operative Time
4.Robotic solution for orthopedic surgery.
Mingxing FAN ; Qi ZHANG ; Yanming FANG ; Wei TIAN
Chinese Medical Journal 2023;136(12):1387-1389
5.Simultaneous implantation and tooth preparation technology guided by 3D-printed guide.
Nan HU ; Chunxu LIU ; Jing GAO ; Chenyang XIE ; Jiayi YU ; Luming JIA ; Haiyang YU
West China Journal of Stomatology 2023;41(4):483-490
Using digital technologies in concurrently performing missing tooth implantation and preparation of remaining teeth is a solution to reduce the number of visits and improve efficiency. This paper proposes a digital process for simultaneously implanting and preparing teeth. It integrates implant surgical guide and 3D-printed tooth preparation guide into a single guide and completes guided implant placement and precise tooth preparation. Based on "repair-oriented" virtual implant planning, the implant surgical guide can improve the efficiency and predictability of implant placement, and its linear accuracy is about 1 mm. The tooth preparation guide precisely guides tooth preparation and restoration space visualization, ensuring the quality of the tooth preparation. The two guides have different design accuracy requirements, and thus their combination improves the overall guiding accuracy requirements. The concurrent application of the two guides minimizes the clinical operation time, number of visits, and economic burden of patients.
Humans
;
Surgery, Computer-Assisted
;
Dental Implantation, Endosseous
;
Printing, Three-Dimensional
;
Technology
;
Tooth Preparation
;
Computer-Aided Design
;
Dental Implants
;
Imaging, Three-Dimensional
;
Cone-Beam Computed Tomography
6.From "Empirical Surgery" to "Precision Surgery": establishment and clinical application of precision orthognathic surgery system.
Xudong WANG ; Hongpu WEI ; Biao LI
West China Journal of Stomatology 2023;41(5):491-501
Orthognathic surgery, which involve osteotomy and repositioning of the maxillomandibular complex, has recently emerged as a crucial method of correcting dentofacial deformities. The optimal placement of the maxillomandibular complex holds utmost significance during orthognathic surgery because it directly affects the surgical outcome. To accurately achieve the ideal position of the maxillomandibular complex, with the rapid advancements in digital surgery and 3D-printing technology, orthognathic surgery has entered an era of "Precision Surgery" from the pervious "Empirical Surgery." This article provides comprehensive insights into our extensive research and exploration of the treatment modality known as "precision orthognathic surgery" over the years. We also present the technical system and application in"Ortho+X" treatment modality to offer valuable references and assistance to our colleagues in the field.
Orthognathic Surgery
;
Orthognathic Surgical Procedures
;
Printing, Three-Dimensional
;
Surgery, Computer-Assisted
7.Clinical application of percutaneous pedicle screw placement guided by ultrasound volume navigation combined with X-ray fluoroscopy: a prospective randomized controlled study.
Xuxin LIN ; Lijie SHANG ; Suhong SHEN ; Qingfeng WANG ; Xiaoyan FU ; Gang ZHAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1253-1258
OBJECTIVE:
To explore the feasibility and accuracy of ultrasound volume navigation (UVN) combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation through a prospective randomized controlled study.
METHODS:
Patients with thoracic and lumbar vertebral fractures scheduled for percutaneous pedicle screw fixation between January 2022 and January 2023 were enrolled. Among them, 60 patients met the selection criteria and were included in the study. There were 28 males and 32 females, with an average age of 49.5 years (range, 29-60 years). The cause of injury included 20 cases of traffic accidents, 21 cases of falls, 17 cases of slips, and 2 cases of heavy object impact. The interval from injury to hospital admission ranged from 1 to 5 days (mean, 1.57 days). The fracture located at T 12 in 15 cases, L 1 in 20 cases, L 2 in 19 cases, and L 3 in 6 cases. The study used each patient as their own control, randomly guiding pedicle screw implantation using UVN combined with X-ray fluoroscopy on one side of the vertebral body and the adjacent segment (trial group), while the other side was implanted under X-ray fluoroscopy (control group). A total of 4 screws and 2 rods were implanted in each patient. The implantation time and fluoroscopy frequency during implantation of each screw, angle deviation and distance deviation between actual and preoperative planned trajectory by imaging examination, and the occurrence of zygapophysial joint invasion were recorded.
RESULTS:
In terms of screw implantation time, fluoroscopy frequency, angle deviation, distance deviation, and incidence of zygapophysial joint invasion, the trial group showed superior results compared to the control group, and the differences were significant ( P<0.05).
CONCLUSION
UVN combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation can yreduce screw implantation time, adjust dynamically, reduce operational difficulty, and reduce radiation damage.
Male
;
Female
;
Humans
;
Middle Aged
;
Pedicle Screws
;
Prospective Studies
;
X-Rays
;
Surgery, Computer-Assisted/methods*
;
Spinal Fusion/methods*
;
Fluoroscopy/methods*
;
Lumbar Vertebrae/injuries*
8.Comparison of screw placement guided by O-arm navigation and ultrasound volume navigation in minimally invasive transforaminal lumbar interbody fusion.
Xuxin LIN ; Qing CHANG ; Lijie SHANG ; Suhong SHEN ; Zhuo FU ; Yifan WANG ; Lufan ZHOU ; Hao FU ; Gang ZHAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(11):1403-1409
OBJECTIVE:
To compare the effectiveness of O-arm navigation and ultrasound volume navigation (UVN) in guiding screw placement during minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) surgery.
METHODS:
Sixty patients who underwent MIS-TLIF surgery for lumbar disc herniation between June 2022 and June 2023 and met the selection criteria were included in the study. They were randomly assigned to group A (screw placement guided by UVN during MIS-TLIF) or group B (screw placement guided by O-arm navigation during MIS-TLIF), with 30 cases in each group. There was no significant difference in baseline data, including gender, age, body mass index, and surgical segment, between the two groups ( P>0.05). Intraoperative data, including average single screw placement time, total radiation dose, and average single screw effective radiation dose, were recorded and calculated. Postoperatively, X-ray film and CT scans were performed at 10 days to evaluate screw placement accuracy and assess facet joint violation. Pearson correlation and Spearman correlation analyses were used to observe the relationship between the studied parameters (average single screw placement time and screw placement accuracy grading) and BMI.
RESULTS:
The average single screw placement time in group B was significantly shorter than that in group A, and the total radiation dose of single segment and multi-segment and the average single screw effective radiation dose in group B were significantly higher than those in group A ( P<0.05). There was no significant difference in the total radiation dose between single segment and multiple segments in group B ( P>0.05), while the total radiation dose of multiple segments was significantly higher than that of single segment in group A ( P<0.05). No significant difference was found in the accuracy of screw implantation between the two groups ( P>0.05). In both groups, the grade 1 and grade 2 screws broke through the outer wall of the pedicle, and no screw broke through the inner wall of the pedicle. There was no significant difference in the rate of facet joint violation between the two groups ( P>0.05). In group A, both the average single screw placement time and screw placement accuracy grading were positively correlated with BMI ( r=0.677, P<0.001; r=0.222, P=0.012), while in group B, neither of them was correlated with BMI ( r=0.224, P=0.233; r=0.034, P=0.697).
CONCLUSION
UVN-guided screw placement in MIS-TLIF surgery demonstrates comparable efficiency, visualization, and accuracy to O-arm navigation, while significantly reducing radiation exposure. However, it may be influenced by factors such as obesity, which poses certain limitations.
Humans
;
Imaging, Three-Dimensional
;
Lumbar Vertebrae/surgery*
;
Minimally Invasive Surgical Procedures
;
Pedicle Screws
;
Retrospective Studies
;
Spinal Fusion
;
Surgery, Computer-Assisted
;
Tomography, X-Ray Computed
;
Treatment Outcome
9.Current application and limitations of augmented reality in the stomatology.
Yan Xue XU ; Ming Rui ZHANG ; Li FU
Chinese Journal of Stomatology 2023;58(6):592-597
Computer-assisted technology are gradually integrated into dental education and clinical treatment. As a cutting-edge technology in computer-aided medicine, augmented reality can not only be used as an aid to dental education by presenting three-dimensional scenes for teaching demonstration and experimental skills training, but also can superimpose virtual image information of patients onto real lesion areas for real-time feedback and intraoperative navigation. This review explores the current applications and limitations of augmented reality in dentistry to provide a reference for future research.
Humans
;
Augmented Reality
;
Oral Medicine
;
Surgery, Computer-Assisted/methods*
;
Imaging, Three-Dimensional
10.Application of a new point contact pedicle navigation template as an auxiliary screw implant in scoliosis correction surgery.
Lihang WANG ; Qian TANG ; Qiling CHEN ; Tingsheng LU ; Shudan YAO ; Xingwei PU ; Linsong JI ; Chunshan LUO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):700-705
OBJECTIVE:
To explore the effectiveness of a new point contact pedicle navigation template (referred to as "new navigation template" for simplicity) in assisting screw implantation in scoliosis correction surgery.
METHODS:
Twenty-five patients with scoliosis, who met the selection criteria between February 2020 and February 2023, were selected as the trial group. During the scoliosis correction surgery, the three-dimensional printed new navigation template was used to assist in screw implantation. Fifty patients who had undergone screw implantation with traditional free-hand implantation technique between February 2019 and February 2023 were matched according to the inclusion and exclusion criteria as the control group. There was no significant difference between the two groups ( P>0.05) in terms of gender, age, disease duration, Cobb angle on the coronal plane of the main curve, Cobb angle at the Bending position of the main curve, the position of the apical vertebrae of the main curve, and the number of vertebrae with the pedicle diameter lower than 50%/75% of the national average, and the number of patients whose apical vertebrae rotation exceeded 40°. The number of fused vertebrae, the number of pedicle screws, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were compared between the two groups. The occurrence of implant complications was observed. Based on the X-ray films at 2 weeks after operation, the pedicle screw grading was recorded, the accuracy of the implant and the main curvature correction rate were calculated.
RESULTS:
Both groups successfully completed the surgeries. Among them, the trial group implanted 267 screws and fused 177 vertebrae; the control group implanted 523 screws and fused 358 vertebrae. There was no significant difference between the two groups ( P>0.05) in terms of the number of fused vertebrae, the number of pedicle screws, the pedicle screw grading and accuracy, and the main curvature correction rate. However, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were significantly lower in trial group than in control group ( P<0.05). There was no complications related to screws implantation during or after operation in the two groups.
CONCLUSION
The new navigation template is suitable for all kinds of deformed vertebral lamina and articular process, which not only improves the accuracy of screw implantation, but also reduces the difficulty of operation, shortens the operation time, and reduces intraoperative bleeding.
Humans
;
Orthopedic Procedures
;
Pedicle Screws
;
Retrospective Studies
;
Scoliosis/surgery*
;
Spinal Fusion/methods*
;
Spine
;
Surgery, Computer-Assisted/methods*

Result Analysis
Print
Save
E-mail