1.The diagnostic performance of nuchal translucency alone as a screening test for Down syndrome: A systematic review and meta-analysis.
Ma. Sergia Fatima P. SUCALDITO ; John Jefferson V. BESA ; Lia M. PALILEO-VILLANUEVA
Acta Medica Philippina 2025;59(Early Access 2025):1-17
BACKGROUND
Down syndrome or trisomy 21, the most common chromosomal disorder, results from the presence of a third copy of chromosome 21 and manifests as mild to moderate intellectual disability, growth retardation, congenital heart defects, gastrointestinal abnormalities, and characteristic facial features. Several methods have been used to screen for Down syndrome in the prenatal period, such as ultrasound, biomarkers, cell-free DNA testing, and combinations of these tests. A positive result from one or more of these screening tests signals the need for confirmatory karyotyping to clinch the diagnosis. Ultrasound between 11 to 14 weeks of gestation can evaluate nuchal translucency (NT) to screen for Down syndrome. During the second trimester, a triple or quadruple test can also be performed alone or in addition to NT to quantify Down syndrome risk. In limited resource settings however, only the measurement of NT via ultrasound can be performed since biomarker tests are either unavailable or inaccessible. While the diagnostic performance of NT measurement alone has been investigated in several observational studies, there is no consensus on its performance as a sole test to screen for Down syndrome.
OBJECTIVETo determine the diagnostic performance of NT during prenatal first-trimester ultrasound as a screening test for Down syndrome.
METHODSWe performed a systematic search on the PubMed, ProQuest, and Cochrane Library databases for recent systematic reviews and meta-analyses that addressed the objective. The existing reviews found were then independently appraised by the two reviewers with the AMSTAR-2 checklist. To update the existing reviews, a systematic search was done in the same databases to identify additional primary diagnostic studies, which were appraised using the QUADAS-2 tool. Random-effects univariate meta-analysis and summary receiving operator curve (HSROC) analysis for the outcomes were performed using Review Manager version 5.4 and R version 4.2.2, respectively. Subgroup analysis was performed by stratifying the baseline risk of mothers for fetal anomaly as low- or high-risk. Highrisk mothers were defined as women with risk factors such as advanced age, positive serum screen, presence of other ultrasound anomalies, and history of previous fetus with anomaly.
RESULTSWe found 22 cohort studies (n=225,846) of women at low-risk for fetal anomaly. The pooled sensitivity was 67.8% (95% CI: 61.4%-73.6%, I2=70.4%) and specificity was 96.3% (95% CI: 95.5%-96.9%, I2=96.7%). For low-risk women, the overall certainty of evidence was low, due to different modes of verification and heterogeneity not completely explained by variability in baseline risk or cut-points. Seven studies (n=9,197) were on high-risk women. The pooled sensitivity was 62.2% (95% CI: 54.1%-69.7%, I2=38.8%) and specificity was 96.5% (95% CI: 93.6%-98.1%, I2=95.5%). For women at high-risk, the evidence was rated as moderate due to differential verification.
CONCLUSIONOur analysis showed that NT measured through first-trimester ultrasound is specific for Down syndrome but has low sensitivity. Despite this, it is a useful screening test for Down syndrome in low-resource settings where other strategies may not be available or accessible. Furthermore, interpretation of NT results must take into consideration its limited sensitivity as this may lead to missed cases.
Human ; Nuchal Translucency Measurement ; Down Syndrome ; Sensitivity And Specificity
2.Value of High-Frequency Ultrasound in the Diagnosis of Pronator Teres Syndrome.
Min HU ; Shi-Yu CHEN ; Xiao-Long YANG ; Tian-Fang LIN ; Jie-Feng WANG ; Zheng-Hua ZANG
Acta Academiae Medicinae Sinicae 2023;45(3):436-439
Objective To investigate the clinical value of high-frequency ultrasound in the diagnosis of pronator teres syndrome (PTS). Methods The high-frequency ultrasound was employed to examine and measure the median nerve of the pronator teres muscle in 30 patients with PTS and 30 healthy volunteers (control group).The long-axis diameter (LA),short-axis diameter (SA) and cross-sectional area (CSA) of the median nerve were measured.The receiver operating characteristic curve of the median nerve ultrasonic measurement results was established,and the area under the curve (AUC) was calculated.The diagnostic efficiency of each index for PTS was compared with the surgical results as a reference. Results The PTS group showed larger LA[(5.02±0.50) mm vs.(3.89±0.41) mm;t=4.38,P=0.013],SA[(2.55±0.46) mm vs.(1.70±0.41) mm;t=5.19,P=0.009],and CSA[(11.13±3.72) mm2 vs.(6.88±2.68) mm2;t=8.42,P=0.008] of the median nerve than the control group.The AUC of CSA,SA,and LA was 94.3% (95%CI=0.912-0.972,Z=3.586,P=0.001),77.7% (95%CI=0.734-0.815,Z=2.855, P=0.006),and 78.8% (95%CI=0.752-0.821,Z=3.091,P=0.004),respectively.With 8.63 mm2 as the cutoff value,the sensitivity and specificity of CSA in diagnosing PTS were 93.3% and 90.0%,respectively. Conclusion High-frequency ultrasound is a practical method for diagnosing PTS,and the CSA of median nerve has a high diagnostic value.
Humans
;
Forearm/innervation*
;
Muscle, Skeletal/innervation*
;
Median Nerve/diagnostic imaging*
;
Ultrasonography/methods*
;
Sensitivity and Specificity
3.Primary study on recognition of vascular stiffness based on wavelet scattering neural network.
Shuqi REN ; Zengsheng CHEN ; Xiaoyan DENG ; Yubo FAN ; Anqiang SUN
Journal of Biomedical Engineering 2023;40(2):244-248
Cardiovascular disease is the leading cause of death worldwide, accounting for 48.0% of all deaths in Europe and 34.3% in the United States. Studies have shown that arterial stiffness takes precedence over vascular structural changes and is therefore considered to be an independent predictor of many cardiovascular diseases. At the same time, the characteristics of Korotkoff signal is related to vascular compliance. The purpose of this study is to explore the feasibility of detecting vascular stiffness based on the characteristics of Korotkoff signal. First, the Korotkoff signals of normal and stiff vessels were collected and preprocessed. Then the scattering features of Korotkoff signal were extracted by wavelet scattering network. Next, the long short-term memory (LSTM) network was established as a classification model to classify the normal and stiff vessels according to the scattering features. Finally, the performance of the classification model was evaluated by some parameters, such as accuracy, sensitivity, and specificity. In this study, 97 cases of Korotkoff signal were collected, including 47 cases from normal vessels and 50 cases from stiff vessels, which were divided into training set and test set according to the ratio of 8 : 2. The accuracy, sensitivity and specificity of the final classification model was 86.4%, 92.3% and 77.8%, respectively. At present, non-invasive screening method for vascular stiffness is very limited. The results of this study show that the characteristics of Korotkoff signal are affected by vascular compliance, and it is feasible to use the characteristics of Korotkoff signal to detect vascular stiffness. This study might be providing a new idea for non-invasive detection of vascular stiffness.
Humans
;
Vascular Stiffness
;
Neural Networks, Computer
;
Cardiovascular Diseases/diagnosis*
;
Sensitivity and Specificity
4.Research on rapid detection technology of airborne pathogenic organisms based on up-conversion phosphor technology.
Qiao Yun ZHANG ; Xiu Jun SONG ; Hong Ling OU ; Zhan ZHANG ; Ying Ying MA ; Xin Ru WANG
Chinese Journal of Preventive Medicine 2023;57(4):572-576
Objective: To explore the application of up-conversing phosphor technology (UPT) to detect pathogenic organisms in the air. Methods: The performance of UPT was verified with Staphylococcus aureus, Yersinia pestis and Escherichia coli O157 as simulated strains, including stability, specificity, sensitivity and response time tests; Air particle sampler is used to collect air samples in the field microenvironment test chamber, and UPT is used for detection. At the same time, compared with the traditional culture method, the practicability of UPT is verified. Results: The coefficient of variation in laboratory was 9.62% and 8.02% when the concentration of 107 CFU/ml and 108 CFU/ml were detected by UPT. The results were less than the allowable target, and the detection system had good stability. The specificity of UPT was verified by Staphylococcus aureus. The results showed that no non-Staphylococcus aureus was detected, and the positive detection rate of different kinds of Staphylococcus aureus was 100%. The specificity of the detection system was good. The sensitivity of UPT for detecting Staphylococcus aureus was 104 CFU/ml. Detection sensitivity of Yersinia pestis ≥103 CFU/ml; The detection sensitivity of Escherichia coli O157 is ≥103 CFU/ml, and the response time of UPT to bacteria is within 15 min (all 10 min 15 s). The detection results of bacteria contentration in the air of the on-site microenvironment test cabin by UPT showed that when the concentration of Escherichia coli O157 in the air reached above 104 CFU/m3, the detection results of UPT were positive, and with the increase of air concentration, the numerical concentration measured by UPT showed an upward trend, which was positively correlated with the concentration of bacteria in the air. Conclusion: UPT may be feasible as a rapid method to evaluate the species and contentration of pathogenic organisms in the air.
Humans
;
Sensitivity and Specificity
;
Technology
5.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
6.Results analysis of mNGS applied to infectious diseases.
Xi Wen JIANG ; Zhi Kun LIANG ; Li ZENG ; Ya Li YUAN
Chinese Journal of Preventive Medicine 2023;57(7):1124-1130
The application of metagenomic second-generation sequencing (mNGS) is shifting from research to clinical laboratories due to rapid technological advances and significant cost reductions. Although many studies and case reports have confirmed that the success of mNGS in improving the prevention, diagnosis, treatment and tracking of infectious diseases, there are still some obstacles that must be overcome. The results of mNGS show all the possible pathogens in the sample, however, in the face of thousands of microbes that can infect humans, it remains challenging to accurately identify the key pathogens. So far, there is no unified interpretation standard for mNGS in clinical practice. This article reviews the interpretation of mNGS results for pathogen infection in different systems, the clinical interpretation and application regulations of mNGS results, and the challenges of mNGS interpretation in pathogen diagnosis.
Humans
;
Communicable Diseases
;
Metagenomics
;
Sensitivity and Specificity
7.The performance of digital chest radiographs in the detection and diagnosis of pulmonary nodules and the consistency among readers.
Min LIANG ; Shi Jun ZHAO ; Li Na ZHOU ; Xiao Juan XU ; Ya Wen WANG ; Lin NIU ; Hui Hui WANG ; Wei TANG ; Ning WU
Chinese Journal of Oncology 2023;45(3):265-272
Objective: To investigate the detection and diagnostic efficacy of chest radiographs for ≤30 mm pulmonary nodules and the factors affecting them, and to compare the level of consistency among readers. Methods: A total of 43 patients with asymptomatic pulmonary nodules who consulted in Cancer Hospital, Chinese Academy of Medical Sciences from 2012 to 2014 and had chest CT and X-ray chest radiographs during the same period were retrospectively selected, and one nodule ≤30 mm was visible on chest CT images in the whole group (total 43 nodules in the whole group). One senior radiologist with more than 20 years of experience in imaging diagnosis reviewed CT images and recording the size, morphology, location, and density of nodules was selected retrospectively. Six radiologists with different levels of experience (2 residents, 2 attending physicians and 2 associate chief physicians independently reviewed the chest images and recorded the time of review, nodule detection, and diagnostic opinion. The CT imaging characteristics of detected and undetected nodules on X images were compared, and the factors affecting the detection of nodules on X-ray images were analyzed. Detection sensitivity and diagnosis accuracy rate of 6 radiologists were calculated, and the level of consistency among them was compared to analyze the influence of radiologists' seniority and reading time on the diagnosis results. Results: The number of nodules detected by all 6 radiologists was 17, with a sensitivity of detection of 39.5%(17/43). The number of nodules detected by ≥5, ≥4, ≥3, ≥2, and ≥1 physicians was 20, 21, 23, 25, and 28 nodules, respectively, with detection sensitivities of 46.5%, 48.8%, 53.5%, 58.1%, and 65.1%, respectively. Reasons for false-negative result of detection on X-ray images included the size, location, density, and morphology of the nodule. The sensitivity of detecting ≤30 mm, ≤20 mm, ≤15 mm, and ≤10 mm nodules was 46.5%-58.1%, 45.9%-54.1%, 36.0%-44.0%, and 36.4% for the 6 radiologists, respectively; the diagnosis accuracy rate was 19.0%-85.0%, 16.7%-6.5%, 18.2%-80.0%, and 0%-75.0%, respectively. The consistency of nodule detection among 6 doctors was good (Kappa value: 0.629-0.907) and the consistency of diagnostic results among them was moderate or poor (Kappa value: 0.350-0.653). The higher the radiologist's seniority, the shorter the time required to read the images. The reading time and the seniority of the radiologists had no significant influence on the detection and diagnosis results (P>0.05). Conclusions: The ability of radiographs to detect lung nodules ≤30 mm is limited, and the ability to determine the nature of the nodules is not sufficient, and the increase in reading time and seniority of the radiologists will not improve the diagnostic accuracy. X-ray film exam alone is not suitable for lung cancer diagnosis.
Humans
;
Retrospective Studies
;
Solitary Pulmonary Nodule/diagnostic imaging*
;
Radiography
;
Multiple Pulmonary Nodules/diagnostic imaging*
;
Tomography, X-Ray Computed/methods*
;
Lung Neoplasms/diagnostic imaging*
;
Sensitivity and Specificity
;
Radiographic Image Interpretation, Computer-Assisted/methods*
8.Implementation and quality control of human immunodeficiency virus laboratory diagnosis strategy.
Yuan Fang WANG ; Dong Dong LI ; Yi XIE
Chinese Journal of Preventive Medicine 2023;57(1):1-7
The laboratory diagnostic strategy for human immunodeficiency virus (HIV) is a process to accurately detect HIV patients through a combination of available HIV tests. Laboratory tests for HIV infection are mainly serological antibody and antigen testing and HIV RNA testing. With the update of testing reagents, the sensitivity and specificity have improved substantially and the window period of detection has shortened, but there is a risk of false positives. Various guidelines have recommended different diagnostic strategies for different target populations and different prevalence regions to guide patients to confirm the diagnosis and receive standardized antiretroviral therapy as early as possible. How to refer to the diagnostic strategies, reduce false positives and shorten the window period while increasing the detection rate is an urgent issue for laboratories to address. This article describes the characteristics and advantages and disadvantages of testing methods related to HIV infection from the perspective of laboratory diagnostic strategies, as well as the impact of the development of treatments on diagnostic strategies, in order to provide theoretical support for the practical application of HIV diagnostic strategies.
Humans
;
HIV
;
HIV Infections/diagnosis*
;
Sensitivity and Specificity
;
Clinical Laboratory Techniques/methods*
;
Quality Control
9.Establishment and preliminary application of quantitative real-time PCR assay for the detection of SARS-CoV-2 subgenomic nucleocapsid RNA.
Xiao Juan ZHU ; Yin CHEN ; Bin WU ; Yi Yue GE ; Tao WU ; Qiao QIAO ; Kang Chen ZHAO ; Lun Biao CUI
Chinese Journal of Preventive Medicine 2023;57(2):268-272
Objective: To establish a rapid and specific quantitative real-time PCR (qPCR) method for the detection of SARS-CoV-2 subgenomic nucleocapsid RNA (SgN) in patients with COVID-19 or environmental samples. Methods: The qPCR assay was established by designing specific primers and TaqMan probe based on the SARS-CoV-2 genomic sequence in Global Initiative of Sharing All Influenza Data (GISAID) database. The reaction conditions were optimized by using different annealing temperature, different primers and probe concentrations and the standard curve was established. Further, the specificity, sensitivity and repeatability were also assessed. The established SgN and genomic RNA (gRNA) qPCR assays were both applied to detect 21 environmental samples and 351 clinical samples containing 48 recovered patients. In the specimens with both positive gRNA and positive SgN, 25 specimens were inoculated on cells. Results: The primers and probes of SgN had good specificity for SARS-CoV-2. The minimum detection limit of the preliminarily established qPCR detection method for SgN was 1.5×102 copies/ml, with a coefficient of variation less than 1%. The positive rate of gRNA in 372 samples was 97.04% (361/372). The positive rates of SgN in positive environmental samples and positive clinical samples were 36.84% (7/19) and 49.42% (169/342), respectively. The positive rate and copy number of SgN in Wild strain were lower than those of SARS-CoV-2 Delta strain. Among the 25 SgN positive samples, 12 samples within 5 days of sampling time were all isolated with virus; 13 samples sampled for more than 12 days had no cytopathic effect. Conclusion: A qPCR method for the detection of SARS-CoV-2 SgN has been successfully established. The sensitivity, specificity and repeatability of this method are good.
Humans
;
SARS-CoV-2/genetics*
;
COVID-19/diagnosis*
;
Subgenomic RNA
;
Real-Time Polymerase Chain Reaction/methods*
;
RNA, Viral/genetics*
;
Sensitivity and Specificity
;
Nucleocapsid/chemistry*
;
COVID-19 Testing
10.Value of direct immunohistochemical staining in assisting intraoperative frozen diagnosis of bronchiolar adenoma.
Bo ZHENG ; Shuan Mei ZOU ; Lin YANG ; Xue Min XUE ; Chang Yuan GUO ; Long WANG ; Wen Chao LIU ; Zhao Zhao ZHOU ; Xin LIU ; Li Yan XUE
Chinese Journal of Pathology 2023;52(2):142-146
Objective: To explore the feasibility and application value of intraoperative direct immunohistochemical (IHC) staining in improving the diagnosis accuracy in difficult cases of bronchiolar adenoma (BA). Methods: Nineteen cases with single or multiple pulmonary ground-glass nodules or solid nodules indicated by imaging in Cancer Hospital of Chinese Academy of Medical Sciences from January to July 2021 and with difficulty in differential diagnosis at frozen HE sections were selected. In the experimental group, direct IHC staining of cytokeratin 5/6 (CK5/6) and p63 was performed on frozen sections to assist the differentiation of BA from in situ/micro-invasive adenocarcinoma/adenocarcinoma/invasive mucinous adenocarcinoma. In the control group, two pathologists performed routine frozen HE section diagnosis on these 19 cases. The diagnostic results of paraffin sections were used as the gold standard. The sensitivity and specificity of BA diagnosis, consistency with paraffin diagnosis and time used for frozen diagnosis were compared between the experimental group and the control group. Results: The basal cells of BA were highlighted by CK5/6 and p63 staining. There were no basal cells in the in situ/microinvasive adenocarcinoma/adenocarcinoma/invasive mucinous adenocarcinoma. In the experimental group, the sensitivity and specificity with aid of direct IHC staining for BA were 100% and 86.7%, respectively, and the Kappa value of frozen and paraffin diagnosis was 0.732, and these were significantly higher than those in the control group (P<0.05). The average time consumption in the experimental group (32.4 min) was only 7 min longer than that in the control group (25.4 min). Conclusions: Direct IHC staining can improve the accuracy of BA diagnosis intraoperatively and reduce the risk of misdiagnosis, but require significantly longer time. Thus frozen direct IHC staining should be restricted to cases with difficulty in differentiating benign from malignant diseases, especially when the surgical modalities differ based on the frozen diagnosis.
Humans
;
Paraffin
;
Sensitivity and Specificity
;
Adenocarcinoma in Situ
;
Adenoma/diagnosis*
;
Adenocarcinoma, Mucinous/surgery*
;
Frozen Sections/methods*


Result Analysis