1.The relationship between classroom environment and myopia.
Xi Yan ZHANG ; Yong lin ZHOU ; Feng Yun ZHANG ; Yan WANG ; Wen Yi YANG ; Yao XIANG ; Xin WANG ; Qi HUANG ; Chen Wei PAN ; Jie YANG
Chinese Journal of Epidemiology 2023;44(4):598-606
Objective: Based on a cohort and intervention study of the Eastern Chinese Student Surveillance, Cohort and Intervention Study (ES-SCI), this research aims to explore the correlation between monitor of the school environment and longitudinal data on myopia and provide evidence for the government myopia intervention strategy. Methods: This survey adopts the stratified cluster sampling method with the school as the unit. Students from grade 1 to grade 3 were selected according to the whole class to monitor the school environment in the classroom. Students will use the full-automatic computer optometer (TOPCON RM800) to conduct optometry from 2019 to 2021 under the condition of mydriasis to perform refractive eye examinations. Meantime eye axis length monitoring was also conducted. Cox proportional risk regression model was used to explore the relationship between school environmental monitoring and the occurrence and development of students' myopia. Results: From 2019 to 2021, 2 670 students from 77 classrooms participated in the observation study. The students' diopter after right/left eye mydriasis decreased in varying degrees (P<0.001), and the axial length of the right/left eye increased in various degrees (P<0.001). The weighted qualified rate of per capita area of primary school classrooms increased from 18.0% in 2019 to 26.0% in 2021, the weighted average illuminance pass rate of blackboard surface increased from 23.8% in 2019 to 26.4% in 2021, and the weighted average illuminance pass rate of classroom table decreased from 86.7% in 2019 to 77.5% in 2021. The trend chi-square test was significant (P<0.05). Cox proportional risk regression showed that after correcting for the grade, gender, parental myopia, diet, sleep, near work (sitting posture, working time, electronic mobile equipment, eye exercises), and outdoor activities, the per capita area of 1.36- m2 was the protective factor of eye axis length (HR=0.778, 95%CI: 0.659-0.918, P=0.003); The average reflection ratio of blackboard 0.15-0.19 was the protective factor of eye axis length (HR=0.685, 95%CI: 0.592-0.793, P<0.001); The average illumination of the blackboard 150-, 300-, 500- lx was the protective factor of the eye axis length (HR=0.456, 95%CI: 0.534-0.761, P<0.001; HR=0.794, 95%CI: 0.705-0.895, P<0.001; HR=0.690, 95%CI: 0.619-0.768, P<0.001). The blackboard evenness 0.40-0.59 was the risk factor of eye axis length (HR=1.528, 95%CI: 1.018-2.293, P=0.041), and the blackboard evenness 0.80- was the protection factor of eye axis length (HR=0.542, 95%CI: 0.404-0.726, P<0.001). The evenness of the desktop 0.40-0.59 was the protective factor of eye axis length (HR=0.820, 95%CI: 0.698-0.965, P=0.017). The average illuminance of 150-, 300-, 500- lx was the protective factor of a diopter (HR=0.638, 95%CI: 0.534-0.761, P<0.001; HR=0.911, 95%CI: 0.848-0.978, P=0.011; HR=0.750, 95%CI: 0.702-0.801, P<0.001). The average illumination of desktop 500- lx was a protective factor of a diopter (HR=0.855, 95%CI: 0.763-0.958, P=0.007). Conclusion: School environmental monitoring indicators, such as meeting per capita area standards, passing blackboard, and desk top-related indicators, all play protective effects on myopia development in students.
Humans
;
Mydriasis
;
Myopia/prevention & control*
;
Refraction, Ocular
;
Students
;
Surveys and Questionnaires
;
Schools
2.Present situation of myopia among primary and junior high school students in Yinzhou District, Ningbo City, Zhejiang Province.
Jian CHENG ; Yan Lin SUN ; Zhuo Qiong WANG ; Jun Tao ZHANG ; Liang HU ; Qin Kang LU
Chinese Journal of Preventive Medicine 2022;56(12):1815-1820
Objective: To determine the situation of myopia among primary and junior high school students from 2019 to 2021 in Yinzhou District, Ningbo City, Zhejiang Province. Methods: Cross-sectional study. Department of Ophthalmology, The Affiliated People's Hospital of Ningbo University, carried out a cross-sectional study by reviewing the results of five times visual acuity screens among primary and junior high school students from 2019 to 2021 in Yinzhou District, Ningbo City, Zhejiang Province. The myopia rate, High myopia rate and spherical equivalent refraction were calculated according to the uncorrected distance visual acuity and non-cycloplegic subjective refraction. Chi-square test and analysis of variance were used to analysis the difference of myopia among term, sex and eye. Results: The visual acuity screen had been completed five times from 2019 to 2021 in Yinzhou District, with a total of 458 654 people, of which 454 812 people met the inclusion criteria. The myopia rate of each screen is 56.6%(50 443/89 122),52.5%(48 463/92 311),63.7%(57 968/91 002),53.2%(48 351/90 886),64.4%(58 920/91 491). The rate of Myopia increased gradually with promoting to high grade, and it was obviously in low grade,up to 17.6%. Conclusion: The myopia rate of primary and junior high school students was raising volatility from 2019 to 2021 in Yinzhou District, Ningbo City, Zhejiang Province.
Humans
;
Cross-Sectional Studies
;
Myopia
;
Refraction, Ocular
;
Visual Acuity
;
Students
;
Prevalence
3.Changes of angle Kappa and corneal morphology changes in myopic patients after Sub
Yi DING ; Zhipei ZHANG ; Xiaoshan MIN ; Xiaobo XIA ; Shengfa HU
Journal of Central South University(Medical Sciences) 2021;46(2):162-168
OBJECTIVES:
To investigate angle Kappa and diopter distribution in myopic patients and the changes of angle Kappa and corneal morphology after Sub-Bowman-Keratomileusis (SBK), and to analyze the effects of the surgery on corneal morphologic changes and the patients' near fixation characteristics.
METHODS:
The clinical data of 134 myopic patients (268 eyes) undergoing SBK from August 2015 to August 2016 were retrospectively analyzed. Angle Kappa, corneal curvature in the central corneal region of 3 mm, and post-corneal Diff value were measured by Orbscan IIz Corneal Topography System before operation, 1 month and 6 months after operation. According to the values of angle Kappa before SBK, the patients were divided into 2 groups: the large K group (angle Kappa≥5°, 71 eyes) and the small K group (angle Kappa<5°, 197 eyes). Correlation analysis of the factors influencing angle Kappa at 6 months after operation was performed.
RESULTS:
In the large K group, angle Kappa was (5.67±0.65)°, spherical equivalent was (-4.84±2.32) D, and angle Kappa was decreased after operation (both
CONCLUSIONS
The angle Kappa is decreased in low-moderate myopia patients with large angle Kappa, while is increased in high myopia patients with small angle Kappa after SBK. Myopia patients after SBK will look for the new balance of the binocular accommodation and vergence function for improving the comfort in the near-work situations.
Cornea/surgery*
;
Humans
;
Keratomileusis, Laser In Situ
;
Myopia/surgery*
;
Refraction, Ocular
;
Retrospective Studies
4.A Simplifed Model Eye for Testing Fundus Imaging Device.
Jianhua PENG ; Xiaohang JIA ; Jingtao WANG ; Yiping HU
Chinese Journal of Medical Instrumentation 2019;43(1):21-24
Based on the Gullstrand I model eye, a simplified model eye for testing fundus imaging device is designed. The model eye can reach the following requirements:(1) The refractive characteristics of the ocular refractive tissue are simulated, and the equivalent focal length in air is 17 mm; (2) The differences between relative refractive index differences of the adjacent materials of the simplified model eye and relative refractive index differences of any adjacent two layers (cornea and aqueous humor, aqueous humor and lens, lens and vitreous body) of the Gullstrand I model eye are not more than 1%; (3) In the case of the incident aperture diameter of 3 mm, the differences of radii of the diffuse spots formed by the paraxial light and the axial light are not more than 15%; (4) The differences of angles of chief ray and tangent line of the fundus are not more than 1°; (5) In the case of the incident aperture diameter of 3 mm, the differences of MTF values of the near axis light are not more than 0.1. The simplified model eye can be expected to be used for testing fundus imaging device instead of the test method in ISO 10940:2009 Ophthalmic instruments-Fundus cameras.
Cornea
;
Fundus Oculi
;
Lens, Crystalline
;
diagnostic imaging
;
Refraction, Ocular
5.Comparison of Long-term Clinical Outcomes between Descemet's Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty in Patients with Bullous Keratopathy.
Sung Eun KIM ; Sung A LIM ; Yong Soo BYUN ; Choun Ki JOO
Korean Journal of Ophthalmology 2016;30(6):443-450
PURPOSE: To compare 2-year clinical outcomes of Descemet's stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PK) in patients with bullous keratopathy. METHODS: A retrospective chart review was performed to obtain 2 years of follow-up data of DSAEK or PK at a single center from March 2009 to September 2012. The study comprised 15 eyes of DSAEK and 11 eyes of PK. Outcome measures included best-corrected visual acuity (BCVA), spherical and keratometric changes, central corneal thickness, endothelial cell density, intraocular pressure, and postoperative complications. Graft survival rate was assessed by Kaplan-Meier survival analysis. RESULTS: There were no differences in patient baseline characteristics between the two groups. At postoperative 2 years, better BCVA of 0.69 ± 0.51 logarithm of the minimum angle of resolution (logMAR) was found after DSAEK compared to 0.88 ± 0.48 logMAR after PK. Refractive cylinder in DSAEK and PK was −2.60 ± 1.53 and −6.00 ± 1.05 diopters (D), respectively, and keratometric cylinder was 3.27 ± 3.70 and 6.34 ± 3.51 D, respectively, at postoperative 2 years. The difference of mean spherical equivalents between postoperative 1 month and 2 years was 0.84 D after DSAEK and 2.05 D after PK. A hyperopic shift of 1.17 D was present after 2 years of DSAEK. The mean endothelial cell density at postoperative 2 years was 1,548 ± 456 cells/mm² for DSAEK and 1,052 ± 567 cells/mm² for PK, with a cell loss of 19.96% vs. 52.38%, respectively when compared to postoperative 1 month. No significant difference in central corneal thickness was found between DSAEK and PK (592 ± 75 vs. 563 ± 90 µm, respectively). Finally, the 2-year survival rate did not differ significantly between DSAEK and PK (93.3% vs. 81.8%, respectively, p = 0.344). CONCLUSIONS: Compared to PK, DSAEK provided more stable refractive errors with better visual outcome, lower endothelial cell loss, and a lower rate of graft rejection at postoperative 2 years in patients with bullous keratopathy.
Cornea/diagnostic imaging/*surgery
;
Corneal Diseases/diagnosis/*surgery
;
Descemet Stripping Endothelial Keratoplasty/*methods
;
Female
;
Follow-Up Studies
;
Graft Survival
;
Humans
;
Keratoplasty, Penetrating/*methods
;
Male
;
Middle Aged
;
*Refraction, Ocular
;
Retrospective Studies
;
Time Factors
;
Treatment Outcome
;
Visual Acuity
6.Refractive development and form-deprivation induced myopic refractive error in CBA/CaJ mice.
Yun-Yun LI ; Kang-Wei QIAN ; Xiao-Hua WU ; Wei ZHOU ; Yong-Mei ZHONG ; Shi-Jun WENG
Acta Physiologica Sinica 2016;68(2):135-140
Due to the advantages in genetic manipulation, mice have become one of the most commonly used mammalian models for the study of mechanisms underlying myopia development. However, the vast majority of laboratory mouse strains are incapable of synthesizing melatonin, a neurohormone that may play an important role in myopia generation in humans. The present study investigated refractive development profiles in the CBA/CaJ mouse, a strain proficient in melatonin, and determined whether and how its refractive development could be affected by form-deprivation. Eccentric infrared photoretinoscopy revealed that this animal could be stably refracted, and the refractive error underwent developmental changes, which increased with age in the hyperopic direction and eventually got stable approximately 9 weeks after birth. The absolute values of refractive error in CBA/CaJ mice were larger than those of age-matched C57BL/6 mice, whereas the time points when refractive error reached steady state were similar between the two strains. Five weeks of form-deprivation applied to 3-week-old CBA/CaJ mice by translucent occluder wear caused a significant myopic shift in refractive error, indicating that this strain could be adequately used as a myopia model.
Animals
;
Disease Models, Animal
;
Eye
;
Mice
;
Mice, Inbred C57BL
;
Mice, Inbred CBA
;
Myopia
;
Refraction, Ocular
;
Sensory Deprivation
7.Visual Outcomes, Patient Satisfaction and Spectacle Independence with a Trifocal Diffractive Intraocular Lens.
Florian Tobias Alwin KRETZ ; Chul Young CHOI ; Matthias MÜLLER ; Matthias GERL ; Ralf Helmar GERL ; Gerd Uwe AUFFARTH
Korean Journal of Ophthalmology 2016;30(3):180-191
PURPOSE: To evaluate visual outcomes following implantation of a trifocal diffractive intraocular lens (IOL) and to analyze their correlation with patient satisfaction and ease of performing daily tasks. METHODS: This was a prospective study enrolling 100 eyes of 50 patients undergoing cataract surgery with implantation of trifocal IOL AT LISA tri 839MP. Visual and refractive outcomes were evaluated during a 3-month follow-up. Postoperatively, a questionnaire was used to evaluate patient satisfaction with regard to surgical outcome, spectacle independence, perception of photic phenomena, and ease of performing some vision-related activities. RESULTS: A total of 91%, 87%, and 79% of eyes achieved a monocular uncorrected distance, near, and intermediate visual acuity of 0.1 logarithm of the minimum angle of resolution or better, respectively. After the surgery, 96% of the patients could perform their daily activities without problems. The mean spectacle independence scores for reading, doing computer work, and for distance were 10.33 ± 12.47, 5.71 ± 11.90, and 3.92 ± 9.77, respectively (scale: 0 = no spectacles needed; 40 = spectacles always needed). No correlation was found between spectacle independence and visual outcome (-0.101 ≤ r ≤ 0.244, p ≥ 0.087). Mean scores (0 = no symptoms; 40 = strong symptoms) for glare at night, ghost images, and halos were 15.15 ± 12.02, 4.49 ± 7.92, and 13.34 ± 10.82, respectively. No correlation was found between photic phenomena and visual outcome (-0.199 ≤ r ≤ 0.209, p ≥ 0.150). A total of 80% of patients reported satisfaction with the surgery outcome, and 86% would recommend the surgery to friends and family. CONCLUSIONS: Implantation of the AT LISA tri 839MP IOL after cataract surgery provides effective visual restoration associated with a minimal level of photic phenomena, a positive impact on the performance of vision-related daily activities, and a high level of postoperative patient satisfaction.
Cataract Extraction/*methods
;
Eyeglasses
;
Female
;
Follow-Up Studies
;
Humans
;
Lens Implantation, Intraocular/*methods
;
Male
;
Middle Aged
;
*Patient Satisfaction
;
*Phakic Intraocular Lenses
;
Prospective Studies
;
Prosthesis Design
;
Pseudophakia/*physiopathology
;
Refraction, Ocular/*physiology
;
Surveys and Questionnaires
;
*Visual Acuity
8.Oxidative Stress Levels in Aqueous Humor from High Myopic Patients.
Eun Bi KIM ; Ha Kyoung KIM ; Joon Young HYON ; Won Ryang WEE ; Young Joo SHIN
Korean Journal of Ophthalmology 2016;30(3):172-179
PURPOSE: To compare oxidative stress status in the aqueous humor of highly myopic eyes and control eyes. METHODS: Aqueous humor samples were collected from 15 highly myopic eyes (high myopia group) and 23 cataractous eyes (control group) during cataract surgery. Central corneal thickness, corneal endothelial cell density, hexagonality of corneal endothelial cells, and cell area of corneal endothelial cells were measured using specular microscopy. Axial length was measured using ultrasound biometry. 8-Hydroxydeoxyguanosine (8-OHdG) and malondialdehyde levels were measured using enzyme-linked immunosorbent assay. RESULTS: 8-OHdG level was lower in the aqueous humor of myopic patients than in that of control group (p = 0.014) and was positively correlated with central corneal thickness and negatively correlated with axial length (r = 0.511, p = 0.02; r = -0.382, p < 0.001). There was no correlation between 8-OHdG level and corneal endothelial cell density, hexagonality, or cell area. Malondialdehyde level did not show any correlation with any parameters evaluated. CONCLUSIONS: 8-OHdG might be a sensitive biomarker for evaluating oxidative stress status in the eye. Oxidative stress level was lower in the aqueous humor of highly myopic eyes compared to that in control eyes, which indicates lower metabolic activity in these eyes.
Aged
;
Aqueous Humor/*metabolism
;
Deoxyguanosine/*analogs & derivatives/metabolism
;
Enzyme-Linked Immunosorbent Assay
;
Female
;
Humans
;
Male
;
Malondialdehyde/*metabolism
;
Middle Aged
;
Myopia/*metabolism/physiopathology
;
*Oxidative Stress
;
Refraction, Ocular/*physiology
;
Severity of Illness Index
9.Influence of Biometric Variables on Refractive Outcomes after Cataract Surgery in Angle-closure Glaucoma Patients.
Kyoung Nam KIM ; Hyung Bin LIM ; Jong Joo LEE ; Chang Sik KIM
Korean Journal of Ophthalmology 2016;30(4):280-288
PURPOSE: To evaluate the influence of biometric variables on refractive outcomes after cataract surgery in angle-closure glaucoma (ACG) patients. METHODS: In this case-control study, 42 ACG patients, 40 open-angle glaucoma (OAG) patients, and 35 controls without glaucoma who had undergone conventional cataract surgery were enrolled consecutively. Electronic medical records, including preoperative biometric variables (keratometric diopter, axial length, anterior chamber depth, and lens thickness), the refractive change (RC), and the absolute value of refractive change (ARC) were reviewed. RESULTS: In the control and OAG patients, the anterior chamber depth was negatively correlated with the ARC (r = -0.344, p = 0.043 and r = -0.431, p = 0.006, respectively), whereas there was no correlation in the ACG patients. Lens thickness was positively correlated with the RC, but not with the ARC, in the control and OAG groups (r = 0.391, p = 0.020 and r = 0.501, p = 0.001, respectively). In contrast, lens thickness in the ACG group was not correlated with the RC but was positively correlated with the ARC (r = 0.331, p = 0.032). CONCLUSIONS: In contrast with the anterior chamber depth, preoperatively measured lens thickness may be a useful predictor of the direction of the RC after cataract surgery in control and OAG patients. However, in ACG patients, a thicker lens was correlated with a larger RC, regardless of the direction of the shift (hyperopic or myopic).
Aged
;
Anterior Chamber/*diagnostic imaging
;
Biometry/*methods
;
Female
;
Follow-Up Studies
;
Glaucoma, Angle-Closure/*complications/diagnosis/surgery
;
Glaucoma, Open-Angle/*complications/diagnosis/surgery
;
Humans
;
*Intraocular Pressure
;
Male
;
Middle Aged
;
*Phacoemulsification
;
Refraction, Ocular/*physiology
;
Retrospective Studies
;
Tomography, Optical Coherence
10.Accuracy of three common optometry methods in examination of refraction in juveniles.
Ting SU ; Xiaoshan MIN ; Shuangzhen LIU ; Fengyun LI ; Xingping TAN ; Yanni ZHONG ; Shaoling DENG
Journal of Central South University(Medical Sciences) 2016;41(2):174-181
OBJECTIVE:
To compare the results of the three methods of Suresight handheld autorefractor, table-mounted autorefractor and retinoscopy in examination of juveniles patients with or without cycloplegia.
METHODS:
Firstly, 156 eyes of 78 juveniles (5 to 17 years old) were examined by using WelchAllyn Suresight handheld autorefractor and NIDEK ARK-510A table-mounted autorefractor with or without cycloplegia; secondly, retinoscopy was performed with cycloplegia.
RESULTS:
The spherical power measured by methods without cycloplegia were significantly greater than those measured with cycloplegia (P<0.05); without cycloplegia, there was no significant difference in spherical power, cylindrical power and cylindrical axis between Suresight handheld autorefractor and retinoscopy (P>0.05). These results were highly consistent, suggesting a tendency towards a short sight. However, the spherical power and cylindrical power measured by table-mounted autorefractor was significantly different (P<0.05); with cycloplegia, there was significant difference in spherical power between Suresight handheld autorefractor and retinoscopy (P<0.05).
CONCLUSION
Cycloplegic retinoscopy is necessary for juvenile refraction examination. Under natural pupil situation, Suresight handheld autorefractor is better than table-mounted autorefractor, though both show a myopia tendency. Nevertheless, table-mounted autorefractor can be taken as a recommendation for the prescription of lens trial. As a strong reference for subjective optometry, retinoscopy should be the gold standard for measuring refractive errors.
Adolescent
;
Child
;
Child, Preschool
;
Humans
;
Myopia
;
diagnosis
;
Optometry
;
instrumentation
;
methods
;
Refraction, Ocular
;
Refractive Errors
;
Retinoscopy

Result Analysis
Print
Save
E-mail