1.A Brief Discussion on the in Vitro Diagnostic Reagent Inspection Practice of Self-examination Management Regulations for Medical Device Registration.
Ting HE ; Shuang CHU ; Jing XIE
Chinese Journal of Medical Instrumentation 2023;47(3):324-327
On October 21, 2021, the National Medical Products Administration issued and implemented the Self-examination Management Regulations for Medical Device Registration. The regulations clarify the specific requirements of the registration applicants in the process of self-examination, and put forward detailed requirements from the aspects of self-examination ability, self-examination report, declaration materials and responsibility requirements, so as to ensure the orderly development of the self-examination of medical device registration. Based on the actual verification work of in vitro diagnostic reagent, this study briefly discussed the understanding of the relevant contents of the regulations, aiming to provide some reference for enterprises and related supervision departments that have the requirement of registered self-examination.
Medical Device Legislation
;
Reagent Kits, Diagnostic/standards*
2.Discussion on Supervision and Sampling of Biochemical Test Kits.
Chinese Journal of Medical Instrumentation 2022;46(2):216-218
As an important part of medical devices, in vitro diagnostic reagents are important means to prevent and diagnose and protect people's health. Supervision and sampling is an important and key supervision method to ensure the in vitro diagnostic reagent products are qualified. This paper summarizes the problems encountered in recent years in vitro diagnostic quantitative testing kit supervision sampling, analyzes the causes of these problems, and puts forward corresponding suggestions, hoping to provide constructive suggestions for supervision sampling.
Hematologic Tests
;
Humans
;
Reagent Kits, Diagnostic
;
Reference Standards
3.Analysis of Class II Common Problems in the Registration of
Xiaohe YANG ; Qinfang DONG ; Wenwu ZHU ; Hui ZHEN
Chinese Journal of Medical Instrumentation 2020;44(6):537-540
From the perspective of technical review, this paper made statistics on the supplement contents of
Chemistry, Clinical/standards*
;
China
;
Indicators and Reagents
;
Reagent Kits, Diagnostic/standards*
4.Diagnostic efficacy of three test kits for SARS-CoV-2 nucleic acid detection.
Lihua SHEN ; Fei HUANG ; Xiang CHEN ; Zuan XIONG ; Xiaoyu YANG ; Hui LI ; Feng CHENG ; Jian GUO ; Guofu GONG
Journal of Zhejiang University. Medical sciences 2020;49(2):185-190
OBJECTIVE:
To compare the diagnostic efficacy among three RT-PCR test kits for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid detection.
METHODS:
The throat swab samples from 40 hospitalized patients clinically diagnosed as coronavirus disease 2019 (COVID-19) and 16 hospitalized non-COVID-19 patients were recruited. The SARS-CoV-2 nucleic acid was detected in throat swab samples with RT-PCR test kits from Sansure Biotech ("Sansure" for short), Jiangsu Bioperfectus Technologies ("Bioperfectus" for short) and BGI Genomics ("BGI" for short). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and Kappa value were analyzed. The viral nucleic acid was extracted from the throat swab samples by one-step cleavage and magnetic bead methods, and the efficacy of two extraction methods was also compared. The results of magnetic bead method for nucleic acid extraction by two different extractors (Sansure Natch CS S12C Fully Automated Nucleic Acid Extraction System vs. Tianlong NP968-C Nucleic Acid Extractor) were also compared.
RESULTS:
The sensitivity, specificity, PPV, NPV and kappa value were 95.00%, 87.50%, 95.00%, 87.50%and 0.825 for Sansure kit; 90.00%, 87.50%, 94.74%, 77.78%and 0.747 for the Bioperfectus kit, and 82.50%, 81.25%, 91.67%, 65.00%and 0.593 for the BGI kit, respectively. The positive, negative and total coincident rates and kappa value of viral nucleic acid detection results using the samples extracted by one-step cleavage and magnetic bead methods were 95.24%, 100.00%, 96.43%and 0.909, respectively, but the one-step cleavage method took only 25 min, while the magnetic bead method required 180 min. The positive, negative and total coincident rates and kappa value of viral nucleic acid detection results using the samples extracted by the two different nucleic acid extractors were 85.00%, 100.00%, 89.29% and 0.764, respectively.
CONCLUSIONS
The detection efficacy for SARS-CoV-2 nucleic acid by the Sansure kit is relatively higher and the one-step cleavage method has advantages of convenient operation and less time consuming.
Betacoronavirus
;
genetics
;
isolation & purification
;
Coronavirus Infections
;
diagnosis
;
virology
;
Humans
;
Pandemics
;
Pneumonia, Viral
;
diagnosis
;
virology
;
RNA, Viral
;
genetics
;
isolation & purification
;
Reagent Kits, Diagnostic
;
standards
5.Preparation of Internal Quality Control Material for Lymphocyte Subset Analysis.
Eun Youn ROH ; Sue SHIN ; Jong Hyun YOON ; Sohee OH ; Kyoung Un PARK ; Nuri LEE ; Eun Young SONG
Annals of Laboratory Medicine 2016;36(4):358-361
Lymphocyte subset analysis is widely used in clinical laboratories, and more than two levels of daily QC materials are required for reliable results. Commercially available, expensive QC materials have short shelf lives and may not be suitable in resource-poor settings. We compared different methods for preparing homemade QC material, including fixation with 1%, 2%, or 4% paraformaldehyde (PFA); freezing with 10% dimethylsulfoxide (DMSO), 0.1% bovine serum albumin-phosphate buffered saline, or after ethanolic dehydration; and using cryopreservation temperatures of -20℃, -80℃, or -196℃. We found an optimal experimental condition, which is 'fixation with 4% PFA, freezing with 10% DMSO, and storage at 80℃'. To evaluate long-term stability of QC materials prepared in this optimal condition, two levels of QC materials (QM1 and QM2) were thawed after 30, 33, 35, 37, 60, 62, 64, and 67 days of cryopreservation. Lymphocyte subset was analyzed with BD Multitest IMK kit (BD Biosciences, USA). QM1 and QM2 were stable after 1-2 months of cryopreservation (CV <3% for CD3, CD4, and CD8 and 5-7% for CD16/56 and CD19). We propose this method as an alternative cost-effective protocol for preparing homemade internal QC materials for lymphocyte subset analysis in resource-poor settings.
Cryopreservation
;
Cryoprotective Agents/chemistry
;
*Flow Cytometry/standards
;
Lymphocyte Subsets/*cytology
;
Quality Control
;
Reagent Kits, Diagnostic
;
Time Factors
6.Can a Point-of-Care Troponin I Assay be as Good as a Central Laboratory Assay? A MIDAS Investigation.
W Frank PEACOCK ; Deborah DIERCKS ; Robert BIRKHAHN ; Adam J SINGER ; Judd E HOLLANDER ; Richard NOWAK ; Basmah SAFDAR ; Chadwick D MILLER ; Mary PEBERDY ; Francis COUNSELMAN ; Abhinav CHANDRA ; Joshua KOSOWSKY ; James NEUENSCHWANDER ; Jon SCHROCK ; Elizabeth LEE-LEWANDROWSKI ; William ARNOLD ; John NAGURNEY
Annals of Laboratory Medicine 2016;36(5):405-412
BACKGROUND: We aimed to compare the diagnostic accuracy of the Alere Triage Cardio3 Tropinin I (TnI) assay (Alere, Inc., USA) and the PathFast cTnI-II (Mitsubishi Chemical Medience Corporation, Japan) against the central laboratory assay Singulex Erenna TnI assay (Singulex, USA). METHODS: Using the Markers in the Diagnosis of Acute Coronary Syndromes (MIDAS) study population, we evaluated the ability of three different assays to identify patients with acute myocardial infarction (AMI). The MIDAS dataset, described elsewhere, is a prospective multicenter dataset of emergency department (ED) patients with suspected acute coronary syndrome (ACS) and a planned objective myocardial perfusion evaluation. Myocardial infarction (MI) was diagnosed by central adjudication. RESULTS: The C-statistic with 95% confidence intervals (CI) for diagnosing MI by using a common population (n=241) was 0.95 (0.91-0.99), 0.95 (0.91-0.99), and 0.93 (0.89-0.97) for the Triage, Singulex, and PathFast assays, respectively. Of samples with detectable troponin, the absolute values had high Pearson (R(P)) and Spearman (R(S)) correlations and were R(P)=0.94 and R(S)=0.94 for Triage vs Singulex, R(P)=0.93 and R(S)=0.85 for Triage vs PathFast, and R(P)=0.89 and R(S)=0.73 for PathFast vs Singulex. CONCLUSIONS: In a single comparative population of ED patients with suspected ACS, the Triage Cardio3 TnI, PathFast, and Singulex TnI assays provided similar diagnostic performance for MI.
Acute Coronary Syndrome/*diagnosis
;
Biomarkers/analysis
;
Emergency Service, Hospital
;
Humans
;
Laboratories/standards
;
Myocardial Infarction/diagnosis
;
*Point-of-Care Systems
;
Prospective Studies
;
Reagent Kits, Diagnostic
;
Sensitivity and Specificity
;
Troponin I/*analysis
7.Clinical Evaluation of Rapid Diagnostic Test Kit Using the Polysaccharide as a Genus-Specific Diagnostic Antigen for Leptospirosis in Korea, Bulgaria, and Argentina.
Jin Woo LEE ; Sungman PARK ; Seung Han KIM ; Iva CHRISTOVA ; Paulina JACOB ; Norma B VANASCO ; Yeon Mi KANG ; Ye Ju WOO ; Min Soo KIM ; Young Jin KIM ; Min Kee CHO ; Yoon Won KIM
Journal of Korean Medical Science 2016;31(2):183-189
Leptospirosis, a zoonotic disease that is caused by many serovars which are more than 200 in the world, is an emerging worldwide disease. Accurate and rapid diagnostic tests for leptospirosis are a critical step to diagnose the disease. There are some commercial kits available for diagnosis of leptospirosis, but the obscurity of a species- or genus-specific antigen of pathogenic Leptospira interrogans causes the reduced sensitivity and specificity. In this study, the polysaccharide derived from lipopolysaccharide (LPS) of nonpathogenic Leptospira biflexa serovar patoc was prepared, and the antigenicity was confirmed by immunoblot and enzyme linked immunosorbent assay (ELISA). The performance of the rapid diagnostic test (RDT) kit using the polysaccharide as a diagnostic antigen was evaluated in Korea, Bulgaria and Argentina. The sensitivity was 93.9%, 100%, and 81.0% and the specificity was 97.9%, 100%, and 95.4% in Korea (which is a rare region occurring with 2 serovars mostly), Bulgaria (epidemic region with 3 serovars chiefly) and Argentina (endemic region with 19 serovars mainly) respectively. These results indicate that this RDT is applicable for global diagnosis of leptospirosis. This rapid and effective diagnosis will be helpful for diagnosis and manage of leptospirosis to use and the polysaccharide of Leptospira may be called as genus specific antigen for diagnosis.
Antigens, Bacterial/*immunology
;
Argentina
;
Bulgaria
;
Enzyme-Linked Immunosorbent Assay
;
Female
;
Humans
;
Leptospira/isolation & purification/metabolism
;
Leptospira interrogans/isolation & purification/metabolism
;
Leptospirosis/*diagnosis/microbiology
;
Male
;
Polysaccharides/*immunology
;
Reagent Kits, Diagnostic/*standards
;
Republic of Korea
;
Sensitivity and Specificity
8.Clinical Evaluation of Rapid Diagnostic Test Kit Using the Polysaccharide as a Genus-Specific Diagnostic Antigen for Leptospirosis in Korea, Bulgaria, and Argentina.
Jin Woo LEE ; Sungman PARK ; Seung Han KIM ; Iva CHRISTOVA ; Paulina JACOB ; Norma B VANASCO ; Yeon Mi KANG ; Ye Ju WOO ; Min Soo KIM ; Young Jin KIM ; Min Kee CHO ; Yoon Won KIM
Journal of Korean Medical Science 2016;31(2):183-189
Leptospirosis, a zoonotic disease that is caused by many serovars which are more than 200 in the world, is an emerging worldwide disease. Accurate and rapid diagnostic tests for leptospirosis are a critical step to diagnose the disease. There are some commercial kits available for diagnosis of leptospirosis, but the obscurity of a species- or genus-specific antigen of pathogenic Leptospira interrogans causes the reduced sensitivity and specificity. In this study, the polysaccharide derived from lipopolysaccharide (LPS) of nonpathogenic Leptospira biflexa serovar patoc was prepared, and the antigenicity was confirmed by immunoblot and enzyme linked immunosorbent assay (ELISA). The performance of the rapid diagnostic test (RDT) kit using the polysaccharide as a diagnostic antigen was evaluated in Korea, Bulgaria and Argentina. The sensitivity was 93.9%, 100%, and 81.0% and the specificity was 97.9%, 100%, and 95.4% in Korea (which is a rare region occurring with 2 serovars mostly), Bulgaria (epidemic region with 3 serovars chiefly) and Argentina (endemic region with 19 serovars mainly) respectively. These results indicate that this RDT is applicable for global diagnosis of leptospirosis. This rapid and effective diagnosis will be helpful for diagnosis and manage of leptospirosis to use and the polysaccharide of Leptospira may be called as genus specific antigen for diagnosis.
Antigens, Bacterial/*immunology
;
Argentina
;
Bulgaria
;
Enzyme-Linked Immunosorbent Assay
;
Female
;
Humans
;
Leptospira/isolation & purification/metabolism
;
Leptospira interrogans/isolation & purification/metabolism
;
Leptospirosis/*diagnosis/microbiology
;
Male
;
Polysaccharides/*immunology
;
Reagent Kits, Diagnostic/*standards
;
Republic of Korea
;
Sensitivity and Specificity
9.Discussion on Current Registration Situation and Problems of in Vitro Diagnostic Device of Tumor Marker.
Chinese Journal of Medical Instrumentation 2015;39(5):361-362
This paper aims to analysis of the general problem in the registration dossier and make recommendations on in vitro diagnostic device of tumor markers. On the basis of introducing declarations of the reagents, analysis registration dossier common problems occurs in the products intend to detect novel tumor markers and the combined detection product for multiple tumor markers, and analysis the special requirements for such products.
Biomarkers, Tumor
;
analysis
;
Humans
;
Neoplasms
;
diagnosis
;
Reagent Kits, Diagnostic
;
standards
10.The Quality Analysis of National Supervising Sampling for Rubella Virus IgM Diagnostic Kits in 2014.
Tina YU ; Shoufang QU ; Xiaoyan ZHANG ; Nan SUN ; Shangxian GAO ; Haining LI ; Jie HUANG
Chinese Journal of Medical Instrumentation 2015;39(4):282-284
OBJECTIVETo evaluate the quality status of rubella virus IgM diagnostic kits by national supervising sampling.
METHODSUsing legal inspection combining with exploratory study, the positive and negative coincidence rate, detection limit and repeatability of kits were verified.
RESULTSThe results showed that 15 of 16 batches of kits were qualified using legal inspection, and the passing rate was 93.8%. The unqualified item was negative coincidence rate. In exploratory study, only 11 batches (68.8%) complied with industry standard. The unqualified items were negative coincidence rate, detection limit and repeatability.
CONCLUSIONAt present, rubella virus IgM diagnostic Kits have some quality problems in the market. It is recommended that we adopt industry standard and national reference panel in the registration inspection for the future, which will prompt enterprises to improve quality.
Antibodies, Viral ; Humans ; Immunoglobulin M ; Quality Control ; Reagent Kits, Diagnostic ; standards ; Rubella ; diagnosis ; Rubella virus

Result Analysis
Print
Save
E-mail