1.A case of systematized epidermal nevus (Nevus Unius Lateris) in a 20-year-old Filipino female treated with ablative CO2 laser and topical tretinoin
Maria Emilia Ruth V. Eusebio ; Emy Christine C. Onishi-Limchoa ; Doha Mae Laurisse M. Manalo-Legas
Acta Medica Philippina 2024;58(17):88-93
		                        		
		                        			
		                        			This is a case of a 20-year-old female with no known comorbidities presenting with verrucous plaques arranged in a unilateral blaschkoid distribution at birth. Biopsy was consistent with epidermal nevus hence patient was diagnosed as systematized epidermal nevus, Nevus Unius Lateris type. Gold standard treatment is full thickness surgical excision however, due to the extensive involvement, treatment of this condition remains a challenge. Hence, non-surgical combination of ablative CO2 laser and topical tretinoin 0.1% were done. Thinner lesions (1-3 mm) showed lower recurrence (50%) as compared to thicker lesions (>3 mm) showing 100% recurrence after six months. Hence, another CO2 laser session is needed. Quality of life was measured using the Dermatologic Life Quality Index (DLQI) with noted 35% improvement post-treatment.
		                        		
		                        		
		                        		
		                        			CO2 laser
		                        			;
		                        		
		                        			lasers, gas
		                        			;
		                        		
		                        			tretinoin
		                        			;
		                        		
		                        			retinoids
		                        			
		                        		
		                        	
2.Pulsed dye laser for the treatment of basal cell carcinoma: A systematic review and meta-analysis
Sharmaine H. Lozano ; Agnes Espinoza-Thaebtharm ; Melanie Joy Doria-Ruiz
Journal of the Philippine Dermatological Society 2024;33(Suppl 1):37-37
BACKGROUND
Surgical treatments are the first-line therapy for basal cell carcinoma (BCC). However, for patients who are not candidates for surgery, non-surgical options, such as pulsed dye laser (PDL), may be considered.
OBJECTIVEThis study aimed to review the existing literature on the efficacy, tolerability, and safety of PDL in the treatment of BCC.
METHODOLOGYA systematic review and meta-analysis of PDL for BCC were conducted. The primary outcomes assessed were clearance and recurrence rates. The secondary outcome was the incidence of adverse events.
RESULTSThe review included 11 studies (4 randomized controlled trials, 6 cohort studies, and 1 case series) comprising a total of 204 patients and 295 BCCs. Most BCCs were low-risk histologically and predominantly located on low-risk areas. The meta-analysis revealed an overall clearance rate of 69% and a recurrence rate of 32%, with follow-up periods ranging from 1 to 72 months. However, there was substantial and statistically significant heterogeneity across all studies. The most frequently reported adverse effects included pigmentary changes, primarily hypopigmentation, and varying degrees of scarring.
CONCLUSIONPDL is a safe and tolerable option for treating BCC, though it is not recommended as a sole treatment due to the higher clearance rates and lower recurrence rates associated with other modalities. PDL may be considered an alternative for non-surgical candidates with small or superficial BCCs. Further research is needed to establish standardized parameters for its use in BCC treatment.
Human ; Carcinoma, Basal Cell ; Lasers ; Tumors ; Neoplasms
3.A comparative study of picosecond fractional 1064-nm Nd:YAG laser versus fractional 10,600-Nm carbon dioxide laser in the treatment of abdominal striae alba: A randomized, prospective, assessor-blinded, split-abdomen trial
Sharmaine H. Lozano ; Zharlah Gulmatico-Flores ; Ma. Flordeliz Abad-Casintahan
Journal of the Philippine Dermatological Society 2024;33(Suppl 1):43-43
BACKGROUND
Striae distensae are common disfiguring atrophic dermal scars. Fractonal lasers have been utilized to improve the appearance of this condition.
OBJECTIVESTo compare the efficacy and safety of picosecond fractional 1064-nm Nd:YAG (PS Nd:YAG) laser versus fractional 10,600-nm Carbon Dioxide (CO2) laser in treating abdominal striae alba (SA).
METHODSThirty-two women with Fitzpatrick skin types III-V and abdominal SA participated in a split-abdomen study, receiving four sessions of fractional PS Nd:YAG and CO2 laser treatments on each side at four-week intervals. Striae texture, atrophy, clinical improvement, and satisfaction were assessed for each side at one and three months, with striae length and width compared pre- and post-treatment. Adverse reactions were noted at each visit.
RESULTSAbdomen treated with both lasers had significantly improved skin texture, atrophy and clinical improvements (assessed by physicians and patients) at both follow-ups (p < 0.05), with no difference between the two. Striae length and width did not change significantly (p = 0.203 and p = 0.558). Patients reported greater improvement on the CO2-treated side at 1 month, but not at the final follow-up. High satisfaction was noted for both lasers. Adverse reactions noted after both lasers include erythema, edema, crusting/scaling, pruritus, pain and post-inflammatory hyperpigmentation. The PS Nd:YAG laser was associated with greater pain (p < 0.05), but shorter healing time of 10.26 days.
CONCLUSIONBoth fractional PS Nd:YAG and CO2 lasers were effective, well-tolerated and safe treatment options for SA.
Lasers ; Striae Distensae
4.A prospective study on the safety and efficacy of excimer laser coronary angioplasty for the treatment of degenerated great saphenous vein graft.
Guang Yao ZHAI ; Tie Nan SUN ; Xiang LI ; Ming YE ; Cheng Gang WANG ; Xiao Lin ZU ; Duo YANG ; Hao FU ; Shu Ying QI ; Yu Jie ZHOU ; Hai GAO
Chinese Journal of Cardiology 2023;51(5):490-496
		                        		
		                        			
		                        			Objective: To explore the safety and efficacy of excimer laser coronary angioplasty (ELCA) for the treatment of degenerated great saphenous vein graft (SVG). Methods: This is a single-center, prospective, single-arm study. Patients, who were admitted to the Geriatric Cardiovascular Center of Beijing Anzhen Hospital from January 2022 to June 2022, were consecutively enrolled. Inclusion criteria were recurrent chest pain after coronary artery bypass surgery (CABG), and coronary angiography confirmed that the SVG stenosis was more than 70% but not completely occluded, and interventional treatment for SVG lesions was planned. Before balloon dilation and stent placement, ELCA was used to pretreat the lesions. Optical coherence tomography (OCT) examination was performed and postoperative index of microcirculation resistance (IMR) were assessed after stent implantation. The technique success rate and operation success rate were calculated. The technique success was defined as the successful passage of the ELCA system through the lesion. Operation success was defined as the successful placement of a stent at the lesion. The primary evaluation index of the study was IMR immediately after PCI. Secondary evaluation indexes included thrombolysis in myocardial infarction (TIMI) flow grade, corrected TIMI frame count (cTFC), minimal stent area and stent expansion measured by OCT after PCI, and procedural complications (Ⅳa myocardial infarction, no reflow, perforation). Results: A total of 19 patients aged (66.0±5.6) years were enrolled, including 18 males (94.7%). The age of SVG was 8 (6, 11) years. The length of the lesions was greater than 20 mm, and they were all SVG body lesions. The median stenosis degree was 95% (80%, 99%), and the length of the implanted stent was (41.7±16.3)mm. The operation time was 119 (101, 166) minutes, and the cumulative dose was 2 089 (1 378, 3 011)mGy. The diameter of the laser catheter was 1.4 mm, the maximum energy was 60 mJ, and the maximum frequency was 40 Hz. The technique success and the operation success rate were both 100% (19/19). The IMR after stent implantation was 29.22±5.95. The TIMI flow grade of patients after ELCA and stent implantation was significantly improved (all P>0.05), and the TIMI flow grade of all patients after stent implantation was Grade Ⅲ. The cTFC decreased significantly after ELCA (33.2±7.8) and after stent placement (22.8±7.1) than preoperative level (49.7±13.0) (both P<0.001). The minimum stent area was (5.53±1.36)mm2, and the stent expansion rate was (90.0±4.3)%. Perforation, no reflow, type Ⅳa myocardial infarction and other complications were not observed. However, postoperative high-sensitivity troponin level was significantly increased ((67.937±33.839)ng/L vs. (5.316±3.105)ng/L, P<0.001). Conclusion: ELCA is safe and effective in the treatment of SVG lesions and could improve microcirculation and ensure full expansion of stent.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Aged
		                        			;
		                        		
		                        			Prospective Studies
		                        			;
		                        		
		                        			Percutaneous Coronary Intervention
		                        			;
		                        		
		                        			Lasers, Excimer/therapeutic use*
		                        			;
		                        		
		                        			Saphenous Vein/transplantation*
		                        			;
		                        		
		                        			Constriction, Pathologic
		                        			;
		                        		
		                        			Atherectomy, Coronary/methods*
		                        			;
		                        		
		                        			Myocardial Infarction
		                        			;
		                        		
		                        			Coronary Angiography
		                        			;
		                        		
		                        			Stents
		                        			;
		                        		
		                        			Treatment Outcome
		                        			
		                        		
		                        	
5.Better timing for HoLEP: a retrospective analysis of patients treated with HoLEP over a 10-year period with a 1-year follow-up.
Yu-Cheng TAO ; Zi-Wei WEI ; Chong LIU ; Meng GU ; Qi CHEN ; Yan-Bo CHEN ; Zhong WANG
Asian Journal of Andrology 2023;25(2):281-285
		                        		
		                        			
		                        			The aim of this study was to explore the optimal timing of holmium laser enucleation of the prostate (HoLEP) in patients presenting benign prostatic hyperplasia (BPH) with lower urinary tract symptoms (LUTS). A retrospective analysis was conducted based on the perioperative and postoperative outcome data of 1212 patients who underwent HoLEP in Shanghai Ninth People's Hospital (Shanghai, China) between January 2009 and December 2018. According to the preoperative International Prostate Symptom Score (IPSS), all patients whom we analyzed were divided into Group A (IPSS of 8-18) and Group B (IPSS of 19-35). Peri- and postoperative outcome data were obtained during the 1-year follow-up. IPSS changes were the main postoperative outcomes. The postoperative IPSS, quality of life, peak urinary flow rate, postvoid residual, and overactive bladder symptom score (OABSS) improved significantly. The IPSS improved further in the group with severe LUTS symptoms, but the postoperative IPSS was still higher than that in the moderate LUTS group. OABSSs showing moderate and severe cases after follow-up were more frequent in Group B (9.1%) than in Group A (5.2%) (P < 0.05). There were no significant intergroup differences in the intraoperative American Society of Anesthesiologists or hospitalization expense scores, and the medication costs, as well as the total costs, were significantly higher in Group B. In this retrospective study, HoLEP was an effective treatment for symptomatic BPH. For patients with LUTS, earlier surgery in patients with moderate severity may result in a marginally better 12-month IPSS than that in men with severe symptoms.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Prostatic Hyperplasia/surgery*
		                        			;
		                        		
		                        			Follow-Up Studies
		                        			;
		                        		
		                        			Holmium
		                        			;
		                        		
		                        			Quality of Life
		                        			;
		                        		
		                        			China
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Lower Urinary Tract Symptoms/surgery*
		                        			;
		                        		
		                        			Laser Therapy
		                        			;
		                        		
		                        			Lasers, Solid-State/therapeutic use*
		                        			
		                        		
		                        	
6.Clinical effects of fractional carbon dioxide laser combined with minimally invasive scar release in the treatment of post-acne atrophic scars.
Yan Na GE ; Han Han PAN ; Jiang Bo ZHAO ; Ya CHEN
Chinese Journal of Burns 2023;39(1):53-58
		                        		
		                        			
		                        			Objective: To explore the clinical effects of fractional carbon dioxide laser combined with minimally invasive scar release in the treatment of post-acne atrophic scars. Methods: A retrospectively observational study was conducted. From January to June 2021, 60 patients with grade 3 and 4 post-acne atrophic scars who met the inclusion criteria were admitted to the First Affiliated Hospital of Henan University of Traditional Chinese Medicine. According to the adopted treatment methods, 30 patients treated with fractional carbon dioxide laser combined with minimally invasive scar release were included in combined treatment group (19 males and 11 females, aged (26±4) years), and 30 patients treated with fractional carbon dioxide laser alone were included in laser alone group (18 males and 12 females, aged (25±6) years). All the patients received the treatment once every two months, totally 3 times. Before the first treatment and 2 months after the last treatment, the scars were assessed by échelle d'évaluation clinique des cicatrices d'acné (ECCA). In 2 months after the last treatment, the curative effect was evaluated and the total effective rate was calculated according to the ECCA score. The adverse reactions of patients during the treatment were recorded. Data were statistically analyzed with independent sample t test, Wilcoxon rank-sum test, Mann-Whitney U test, chi-square test, and Fisher's exact probability test. Results: Before the first treatment, the ECCA scores of patients in the two groups were similar (P>0.05). In 2 months after the last treatment, the ECCA scores of patients in combined treatment group were significantly lower than those of laser alone group (Z=-2.89, P<0.05). The ECCA scores of patients in combined treatment group and laser alone group in 2 months after the last treatment were both significantly lower than those before the first treatment (with Z values of -4.81 and -4.79, respectively, P<0.05). In 2 months after the last treatment, the treatment in laser alone group cured the scars in 2 patients, and were markedly effective in 13 patients, effective in 7 patients, and ineffective in 8 patients; the treatment in combined treatment group cured the scars in 4 patients, and were markedly effective in 22 patients, effective in 3 patients, and ineffective in one patients. The total effective rate of scar treatment in combined treatment group (96.67%, 29/30) was significantly higher than 73.33% (22/30) in laser alone group (P<0.05). During treatment, in combined treatment group, 3 patients had pain, one patient had redness and swelling, and one patient had pigmentation. In laser alone group, one patient had pain, and 2 patients had pigmentation. No infection occurred in the wounds of all the patients in the two groups. Conclusions: Compared with fractional carbon dioxide laser alone, fractional carbon dioxide laser combined with minimally invasive scar release for post-acne atrophic scars can result in a higher total effective rate, with simple operation and good effect, so it is worthy of clinical application.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Cicatrix/therapy*
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Lasers, Gas/therapeutic use*
		                        			;
		                        		
		                        			Acne Vulgaris
		                        			;
		                        		
		                        			Atrophy
		                        			;
		                        		
		                        			Pain
		                        			;
		                        		
		                        			Carbon Dioxide
		                        			
		                        		
		                        	
7.Design of a dynamic measurement system for Bl factor spatial distribution of resonant blood viscoelastic sensor.
Jun QIAN ; Haixuan SUN ; Bidou WANG
Journal of Biomedical Engineering 2023;40(5):965-972
		                        		
		                        			
		                        			Bl factor is a key system parameter of the resonant blood viscoelastic sensor. In this paper, a dynamic measurement system for the spatial distribution of Bl factor based on velocity amplitude and motional impedance was designed. The system extracted the velocity amplitude and motional impedance of the coil under the dynamic condition of driving the sensor to generate simple harmonic oscillations using laser displacement and impedance analysis combined with in-phase/quadrature demodulation algorithm, and controlled the equilibrium position of the coil by adjusting the direct current component of the excitation current to realize the position scanning. In the position interval of [-240, 240] μm, the maximum coefficient of variation of the measurement results was 0.077 3%, and the maximum relative error to the simulation results was 2.937 9%, with a linear fitting correlation coefficient R 2 = 0.996 8. The system can be used to accurately measure the spatial distribution of Bl factor of the resonant blood viscoelastic sensor, which provides a technical support for the verification of the design of the sensor magnetic circuit.
		                        		
		                        		
		                        		
		                        			Computer Simulation
		                        			;
		                        		
		                        			Electric Impedance
		                        			;
		                        		
		                        			Motion
		                        			;
		                        		
		                        			Algorithms
		                        			;
		                        		
		                        			Lasers
		                        			
		                        		
		                        	
8.Droplet freeze-thawing system based on solid surface vitrification and laser rewarming.
Wenxin ZHU ; Ping'an PAN ; Yonghua HUANG ; Wei CHEN ; Sha HAN ; Zheng LI ; Jinsheng CHENG
Journal of Biomedical Engineering 2023;40(5):973-981
		                        		
		                        			
		                        			Ultra-rapid cooling and rewarming rate is a critical technical approach to achieve ice-free cells during the freezing and melting process. A set of ultra-rapid solid surface freeze-thaw visualization system was developed based on a sapphire flim, and experiments on droplet freeze-thaw were carried out under different cryoprotectant components, volumes and laser energies. The results showed that the cooling rate of 1 μL mixed cryoprotectant [1.5 mol/L propylene glycol (PG) + 1.5 mol/L ethylene glycol (EG) + 0.5 mol/L trehalose (TRE)] could be 9.2×10 3 °C/min. The volume range of 1-8 μL droplets could be vitrified. After comparing the proportions of multiple cryoprotectants, the combination of equal proportion mixed permeability protectant and trehalose had the best vitrification freezing effect and more uniform crystallization characteristics. During the rewarming operation, the heating curve of glassy droplets containing gold nanoparticles was measured for the first time under the action of 400-1 200 W laser power, and the rewarming rate was up to the order of 10 6 °C/min. According to the droplet images of different power rewarming processes, the laser power range for ice-free rewarming with micron-level resolution was clarified to be 1 400-1 600 W. The work of this paper simultaneously realizes the ultra-high-speed temperature ramp-up, transient visual observation and temperature measurement of droplets, providing technical means for judging the ice free droplets during the freeze-thaw process. It is conducive to promoting the development of ultra-rapid freeze-thaw technology for biological cells and tissues.
		                        		
		                        		
		                        		
		                        			Freezing
		                        			;
		                        		
		                        			Vitrification
		                        			;
		                        		
		                        			Cryopreservation/methods*
		                        			;
		                        		
		                        			Trehalose
		                        			;
		                        		
		                        			Gold
		                        			;
		                        		
		                        			Rewarming
		                        			;
		                        		
		                        			Metal Nanoparticles
		                        			;
		                        		
		                        			Cryoprotective Agents
		                        			;
		                        		
		                        			Lasers
		                        			
		                        		
		                        	
9.Effects of low-level laser on the expression of interleukin-6, tumor necrosis factor‑α, osteoprotegerin, and receptor activator of nuclear factor-κB ligand in human periodontal ligament cells.
Meng TANG ; Zhan-Qin CUI ; Yangyang WANG ; Zengguo CHEN ; Wenjing LI ; Cuiping ZHANG
West China Journal of Stomatology 2023;41(5):521-532
		                        		
		                        			OBJECTIVES:
		                        			This study aims to determine the effects of low-level laser (LLL) on the expression of interleukin-6 (IL-6), tumor necrosis factor (TNF)-α, osteoprotegerin (OPG), and receptor activator of nuclear factor-κB ligand (RANKL) in human periodontal ligament cells (HPDLCs) stimulated by high glucose; and identify the molecular mechanism of LLL therapy in the regulation of periodontal inflammation and bone remodeling during orthodontic treatment in diabetic patients.
		                        		
		                        			METHODS:
		                        			HPDLCs were cultured in vitro to simulate orthodontic after loading and irradiated with LLL therapy. The cultured cells were randomly divided into four groups: low glucose Dulbecco's modification of Eagle's medium (DMEM)+stress stimulation (group A), high glucose DMEM+stress stimulation (group B), hypoglycemic DMEM+LLL therapy+stress stimulation (group C), and hyperglycemic DMEM+LLL therapy+stress stimulation (group D). Groups C and D were further divided into C1 and D1 (energy density: 3.75 J/cm2) and C2 and D2 (energy density: 5.625 J/cm2). Cells in groups A, B, C, and D were irradiated by LLL before irradiation. At 0, 12, 24, 48, and 72 h, the supernatants of the cell cultures were extracted at regular intervals, and the protein expression levels of IL-6, TNF-α, OPG, and RANKL were detected by enzyme-linked immunosorbent assay.
		                        		
		                        			RESULTS:
		                        			1) The levels of IL-6 and TNF-α secreted by HPDLCs increased gradually with time under static pressure stimulation. After 12 h, the levels of IL-6 and TNF-α secreted by HPDLCs in group A were significantly higher than those in groups B, C1, and C2 (P<0.05), which in group B were significantly higher than those in groups D1, and D2 (P<0.01). 2) The OPG protein concentration showed an upward trend before 24 h and a downward trend thereafter. The RANKL protein concentration increased, whereas the OPG/RANKL ratio decreased with time. Significant differen-ces in OPG, RANKL, and OPG/RANKL ratio were found among group A and groups B, C1, C2 as well as group B and groups D1, D2 (P<0.05).
		                        		
		                        			CONCLUSIONS
		                        			1) In the high glucose+stress stimulation environment, the concentrations of IL-6 and TNF-α secreted by HPDLCs increased with time, the expression of OPG decreased, the expression of RANKL increased, and the ratio of OPG/RANKL decreased. As such, high glucose environment can promote bone resorption. After LLL therapy, the levels of IL-6 and TNF-α decreased, indicating that LLL therapy could antagonize the increase in the levels of inflammatory factors induced by high glucose environment and upregulate the expression of OPG in human HPDLCs, downregulation of RANKL expression in HPDLCs resulted in the upregulation of the ratio of OPG/RANKL and reversed the imbalance of bone metabolism induced by high glucose levels. 2) The decrease in inflammatory factors and the regulation of bone metabolism in HPDLCs were enhanced with increasing laser energy density within 3.75-5.625 J/cm2. Hence, the ability of LLL therapy to modulate bone remodeling increases with increasing dose.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Osteoprotegerin
		                        			;
		                        		
		                        			Tumor Necrosis Factor-alpha/metabolism*
		                        			;
		                        		
		                        			Interleukin-6/pharmacology*
		                        			;
		                        		
		                        			RANK Ligand/pharmacology*
		                        			;
		                        		
		                        			Periodontal Ligament/metabolism*
		                        			;
		                        		
		                        			Lasers
		                        			;
		                        		
		                        			Glucose/pharmacology*
		                        			
		                        		
		                        	
10.The removal of three kinds of occlusal veneers by Er: Yag laser.
Jianyu ZHU ; Feifei HONG ; Lianghang HE ; Wei WEN ; Xianlin LEI ; Zhisheng ZHANG ; Lu YIN
West China Journal of Stomatology 2023;41(5):568-572
		                        		
		                        			OBJECTIVES:
		                        			This study aimed to remove occlusal veneers of varied thicknesses and compositions by Er:Yag laser in vitro and analyze the interfacial microstructure between veneers and tooth that irradiated by laser, by which experimental evidence could be provided to support the non-invasive removal of occlusal veneerby laser.
		                        		
		                        			METHODS:
		                        			Fresh mandibular premolars extracted for orthodontic requirements were collected for tooth preparation. Three kinds of ceramic materials (Vita Suprinity, Vita Mark Ⅱ, and Upcera Hyramic) were selected to fabricate occlusal veneer with different thicknesses (1.0, 1.5, and 2.0 mm). One week later, Er:Yag laser (2.5 W and 3.5 W) was used to irradiate and remove the occlusal veneer and recorded the timespan. After the removal operation, the micro-morphologies of samples were examined by scanning electron microscope.
		                        		
		                        			RESULTS:
		                        			Upcera Hyramic veneer failed to be removed (>20 min); the operation span at 2.5 W, Vita Suprinity (96.0 s±16.0 s) was longer than Vita MarkⅡ(84.5 s±19.5 s) in the 1.0 mm group (P<0.05), and Vita Suprinity (246.5 s±13.5 s) was longer than Vita MarkⅡ(170.0 s±14.0 s) in the 1.5 mm group (P<0.05). At 3.5 W, Vita Suprinity (381.0 s±24.0 s) was longer than Vita MarkⅡ(341.5 s±26.5 s) in the 2.0 mm group.
		                        		
		                        			CONCLUSIONS
		                        			Increasing laser power could shorten the operation span and facilitate the removal of occlusal veneers with the same thickness and composition. The occlusal veneer was sustained when insufficient laser power was applied. With the same laser power and ceramic thickness, laser penetration could interfere with the integral of the ceramic structure when the laser interacted with the bonding layer. With the same ceramic composition and laser power, the operation span and laser power increased with the thickness of the occlusal veneer. However, the laser was incapable of removing occlusal resin veneer directly.
		                        		
		                        		
		                        		
		                        			Lasers, Solid-State
		                        			;
		                        		
		                        			Materials Testing
		                        			;
		                        		
		                        			Dental Porcelain/chemistry*
		                        			;
		                        		
		                        			Ceramics/chemistry*
		                        			;
		                        		
		                        			Bicuspid
		                        			;
		                        		
		                        			Dental Veneers
		                        			
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail