1.Condylar jugular diverticulum: A report of 3 cases
Rohan JAGTAP ; Taggreed WAZZAN ; Matthew HANSEN ; Deeba KASHTWARI
Imaging Science in Dentistry 2019;49(3):251-256
Jugular bulb diverticulum is an irregular extension of the jugular bulb into the temporal bone that may be symptomatic or asymptomatic. The jugular bulb has rarely been reported to extend into the occipital condyle; such extension is termed a condylar jugular diverticulum and is characterized as a defect in the occipital condyle contiguous with the jugular bulb. This report details 3 cases of condylar jugular diverticulum. Extension of the jugular bulb into the ipsilateral occipital condyle was noted as an incidental finding on cone-beam computed tomographic (CBCT) images of 3 patients. All 3 patients were asymptomatic, and this finding was unrelated to the initial area of interest. CBCT use is becoming ubiquitous in dentistry, as it allows 3-dimensional evaluation, unlike conventional radiography. Proper interpretation of the entire CBCT is essential, and recognition of the indicators of condylar jugular diverticulum may prevent misdiagnosis of this rare entity.
Cone-Beam Computed Tomography
;
Dentistry
;
Diagnostic Errors
;
Diverticulum
;
Growth and Development
;
Humans
;
Incidental Findings
;
Jugular Veins
;
Radiography
;
Temporal Bone
2.Correction of malposition of central venous catheter with 9-Fr introducer sheath assisted by mobile type diagnostic X-ray apparatus: a case report.
Jaekyu RYU ; Ji Hyun YOON ; Eun Joon LEE ; Chia An LEE ; Seong Chang WOO ; Chang Young JEONG
Korean Journal of Anesthesiology 2015;68(4):402-406
Central venous catheters provide long-term available vascular access. They are useful for central venous pressure monitoring, rapid fluid management, massive transfusion and direct cardiovascular medication, especially in operation. Central venous catheterization is usually performed by the landmark bedside technique without imaging guidance. The complications of central venous catheterization are frequent, which include malposition, pneumothorax, hemothorax, chylothorax, arterial puncture, hematoma, air embolism and infection. Malposition of a central venous catheter is not rare and may cause several complications such as malfunction of the catheter, default measurement of central venous pressure, catheter erosion, thrombophlebitis and cardiac tamponade. In this case, we report a malposition of central venous catheter with 9-Fr introducer sheath which is located in the right subclavian vein via ipsilateral internal jugular vein and the correction of this misplacement assisted by mobile type diagnostic X-ray apparatus (C-arm fluoroscope).
Cardiac Tamponade
;
Catheterization
;
Catheterization, Central Venous
;
Catheters
;
Central Venous Catheters*
;
Central Venous Pressure
;
Chylothorax
;
Embolism, Air
;
Hematoma
;
Hemothorax
;
Jugular Veins
;
Pneumothorax
;
Punctures
;
Radiography*
;
Subclavian Vein
;
Thrombophlebitis
3.Direction of the J-Tip of the Guidewire to Decrease the Malposition Rate of an Internal Jugular Vein Catheter.
Byeong Jun AHN ; Sung Uk CHO ; Won Joon JEONG ; Yeon Ho YOU ; Seung RYU ; Jin Woong LEE ; In Sool YOO ; Yong Chul CHO
Korean Journal of Critical Care Medicine 2015;30(4):280-285
BACKGROUND: We hypothesized that the direction of the J-tip of the guidewire during insertion into the internal jugular vein (IJV) might determine its ultimate location. METHODS: In this study, 300 patients between the ages of 18 and 99 years who required central venous catheterization via IJV in the emergency department enrolled for randomization. IVJ catheterization was successful in 285 of 300 patients. An independent operator randomly prefixed the direction of the J-tip of the guidewire to one of three directions. Based on the direction of the J-tip, patients were allocated into three groups: the J-tip medial-directed group (Group A), the lateral-directed group (Group B), or the downward-directed group (Group C). Postoperative chest radiography was performed on all patients in order to visualize the location of the catheter tip. A catheter is considered malpositioned if it is not located in the superior vena cava or right atrium. RESULTS: Of the total malpositioned catheter tips (8 of 285; 2.8%), the majority (5 of 8; 62.5%) entered the contralateral subclavian vein, 2 (25.0%) were complicated by looping, and 1 (12.5%) entered the ipsilateral subclavian vein. According to the direction of the J-tip of the guidewire, the incidence of malpositioning of the catheter tip was 4 of 92 in Group A (4.3%), 4 of 96 in Group B (4.2%), and there were no malpositions in Group C. There were no significant differences among the three groups (p = 0.114). CONCLUSIONS: The direction of the J-tip of the guidewire had no statistically significant effect on incidence of malpositioned tips.
Catheterization
;
Catheterization, Central Venous
;
Catheters*
;
Central Venous Catheters
;
Emergency Service, Hospital
;
Heart Atria
;
Humans
;
Incidence
;
Jugular Veins*
;
Radiography
;
Random Allocation
;
Subclavian Vein
;
Thorax
;
Vena Cava, Superior
4.Direction of the J-Tip of the Guidewire to Decrease the Malposition Rate of an Internal Jugular Vein Catheter
Byeong Jun AHN ; Sung Uk CHO ; Won Joon JEONG ; Yeon Ho YOU ; Seung RYU ; Jin Woong LEE ; In Sool YOO ; Yong Chul CHO
The Korean Journal of Critical Care Medicine 2015;30(4):280-285
BACKGROUND: We hypothesized that the direction of the J-tip of the guidewire during insertion into the internal jugular vein (IJV) might determine its ultimate location. METHODS: In this study, 300 patients between the ages of 18 and 99 years who required central venous catheterization via IJV in the emergency department enrolled for randomization. IVJ catheterization was successful in 285 of 300 patients. An independent operator randomly prefixed the direction of the J-tip of the guidewire to one of three directions. Based on the direction of the J-tip, patients were allocated into three groups: the J-tip medial-directed group (Group A), the lateral-directed group (Group B), or the downward-directed group (Group C). Postoperative chest radiography was performed on all patients in order to visualize the location of the catheter tip. A catheter is considered malpositioned if it is not located in the superior vena cava or right atrium. RESULTS: Of the total malpositioned catheter tips (8 of 285; 2.8%), the majority (5 of 8; 62.5%) entered the contralateral subclavian vein, 2 (25.0%) were complicated by looping, and 1 (12.5%) entered the ipsilateral subclavian vein. According to the direction of the J-tip of the guidewire, the incidence of malpositioning of the catheter tip was 4 of 92 in Group A (4.3%), 4 of 96 in Group B (4.2%), and there were no malpositions in Group C. There were no significant differences among the three groups (p = 0.114). CONCLUSIONS: The direction of the J-tip of the guidewire had no statistically significant effect on incidence of malpositioned tips.
Catheterization
;
Catheterization, Central Venous
;
Catheters
;
Central Venous Catheters
;
Emergency Service, Hospital
;
Heart Atria
;
Humans
;
Incidence
;
Jugular Veins
;
Radiography
;
Random Allocation
;
Subclavian Vein
;
Thorax
;
Vena Cava, Superior
5.Pulsatile Tinnitus Caused by a Dilated Mastoid Emissary Vein.
Seung Hwan LEE ; Sam Soo KIM ; Kun Yong SUNG ; Eui Cheol NAM
Journal of Korean Medical Science 2013;28(4):628-630
Although pulsatile tinnitus can be audible, objective demonstration of this heartbeat-synchronous sound has rarely been successful. We report a rare case of pulsatile tinnitus in a 44-yr-old female patient, which was induced by a large mastoid emissary vein (MEV) and objectively documented by Doppler sonography of the left posterior auricular region. The tinnitus was intermittent and the patient could adapt to the tinnitus without intervention on the mastoid emissary vein. These findings suggest that a single large MEV can cause pulsatile tinnitus in the absence of other vascular abnormalities, and imaging studies of the posterior fossa and Doppler ultrasonography can aid the diagnosis in such cases.
Adult
;
Dilatation, Pathologic/complications
;
Female
;
Humans
;
Jugular Veins/radiography/ultrasonography
;
Magnetic Resonance Imaging
;
Mastoid/blood supply/ultrasonography
;
Tinnitus/*diagnosis/etiology
;
Tomography, X-Ray
6.How to Decrease the Malposition Rate of Central Venous Catheterization: Real-Time Ultrasound-Guided Reposition.
Hongjoon AHN ; Gundong KIM ; Byulnimhee CHO ; Wonjoon JEONG ; Yeonho YOU ; Seung RYU ; Jinwoong LEE ; Seungwhan KIM ; Insool YOO ; Yongchul CHO
The Korean Journal of Critical Care Medicine 2013;28(4):280-286
BACKGROUND: The purpose of this retrospective and prospective study is to evaluate the efficiency of ultrasound (US) guidance as a method of decreasing the malposition rate of central venous catheterization (CVC) in the emergency department (ED). METHODS: We retrospectively enrolled 379 patients who underwent landmark-guided CVC (Group A) and prospectively enrolled 411 patients who underwent US-guided CVC (Group B) in the ED of a tertiary hospital. Malposition of the CVC tip is identified when the tip is not located in the superior vena cava (SVC). In Group B, we performed US-guided intravascular guide-wire repositioning and then confirmed the location of the CVC tip with chest radiography when the guide-wire was visible in any three other vessels rather than in the approached vessel. In the case of a guide-wire inserted into the right subclavian vein (SCV), the left SCV and both internal jugular veins (IJV) were referred to as the three other vessels. The two subject groups were compared in terms of the malposition rate using Fisher's exact test (significance = p < 0.05). RESULTS: There were 38 malposition cases out of a total of 790 CVCs. The malposition rates of Groups A and B were 5.5% (21) and 4.1% (17), respectively, and no statistically significant difference in malposition rate between the two groups was found. In Group B, the malposition rate was decreased from 4.1% (17) to 1.2% (5) after the guide-wire was repositioned with US guidance, which led to a statistically significant difference in malposition rate (p < 0.01). CONCLUSIONS: The authors concluded that repositioning the guide-wire with US guidance increased correct placement of central venous catheters toward the SVC.
Catheterization, Central Venous*
;
Central Venous Catheters*
;
Emergencies
;
Humans
;
Jugular Veins
;
Prospective Studies
;
Radiography
;
Retrospective Studies
;
Subclavian Vein
;
Tertiary Care Centers
;
Thorax
;
Ultrasonography
;
Vena Cava, Superior
7.Ultrasound and Fluoroscopy-Guided Placement of Central Venous Ports via Internal Jugular Vein: Retrospective Analysis of 1254 Port Implantations at a Single Center.
Se Jin AHN ; Hyo Cheol KIM ; Jin Wook CHUNG ; Sang Bu AN ; Yong Hu YIN ; Hwan Jun JAE ; Jae Hyung PARK
Korean Journal of Radiology 2012;13(3):314-323
OBJECTIVE: To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. MATERIALS AND METHODS: We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the interventional radiologic reports and patient medical records. RESULTS: A total of 433386 catheter maintenance days (mean, 350 days; range 0-1165 days) were recorded. The technical success rate was 99.9% and a total of 61 complications occurred (5%), resulting in a post-procedural complication rate of 0.129 of 1000 catheter days. Among them, peri-procedural complications within 24 hours occurred in five patients (0.4%). There were 56 post-procedural complications including 24 (1.9%, 0.055 of 1000 catheter days) early and 32 (2.6%, 0.074 of 1000 catheter days) late complications including, infection (0.6%, 0.018 of 10000 catheter days), thrombotic malfunction (1.4%, 0.040 of 1000 catheter days), nonthrombotic malfunction (0.9%, 0.025 of 1000 catheter days), venous thrombosis (0.5%, 0.014 of 1000 catheter days), as well as wound problems (1.1%, 0.032 of 1000 catheter days). Thirty six CVPs (3%) were removed due to complications. Bloodstream infections and venous thrombosis were the two main adverse events prolonging hospitalization (mean 13 days and 5 days, respectively). CONCLUSION: Radiologic placement of a central venous port via the internal jugular vein is safe and efficient as evidenced by its high technical success rate and a very low complication rate.
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Catheterization, Central Venous/*methods
;
Female
;
Fluoroscopy
;
Humans
;
*Jugular Veins
;
Male
;
Middle Aged
;
Postoperative Complications/epidemiology
;
*Radiography, Interventional
;
Republic of Korea/epidemiology
;
Retrospective Studies
;
Treatment Outcome
;
*Ultrasonography, Interventional
8.Central Venous Stenosis Caused by Traction of the Innominate Vein due to a Tuberculosis-Destroyed Lung.
Eun Ju SONG ; Dae Hyun BAEK ; Young Hwan HWANG ; So Young LEE ; Young Kwon CHO ; Su Ah SUNG
The Korean Journal of Internal Medicine 2011;26(4):460-462
We report a case of central venous stenosis due to a structural deformity caused by a tuberculosis-destroyed lung in a 65-year-old woman. The patient presented with left facial edema. She had a history of pulmonary tuberculosis, and the chest X-ray revealed a collapsed left lung. Angiography showed leftward deviation of the innominate vein leading to kinking and stenosis of the internal jugular vein. Stent insertion improved her facial edema.
Aged
;
Brachiocephalic Veins/*pathology/radiography
;
*Central Venous Pressure
;
Constriction, Pathologic/*etiology/pathology/therapy
;
Edema/therapy
;
Female
;
Humans
;
Jugular Veins/pathology/radiography
;
Stents
;
Tuberculosis, Pulmonary/*complications/pathology/radiography
;
Vascular Diseases/*etiology/pathology/therapy
9.Endovascular Stent-Graft Treatment of a Traumatic Vertebral Artery Pseudoaneurysm and Vertebrojugular Fistula.
Tanzer SANCAK ; Sadik BILGIC ; Evren USTUNER
Korean Journal of Radiology 2008;9(Suppl):S68-S72
An endovascular intervention is a feasible alternative to the technically challenging conventional surgery for the treatment of traumatic vertebral arterial lesions. This report describes a rare case involving a 22-year-old patient with a traumatic vertebral arterial pseudoaneurysm and multiple arteriovenous fistulas which were successfully sealed using the endovascular stent-graft technique.
Adult
;
Aneurysm, False/etiology/radiography/*therapy
;
Angiography
;
Arteriovenous Fistula/etiology/radiography/*therapy
;
Humans
;
*Jugular Veins/radiography
;
Male
;
Stents
;
Vertebral Artery/*injuries/radiography
10.Hydromediastinum following Internal Jugular Vein Catheterization : A case report.
Hyun Joo KWAK ; Eui Sung LIM ; So Young BAN ; Ji Yeon LEE ; Joo Sun YOON ; Hae Keum KIL ; Ki Jun KIM
Korean Journal of Anesthesiology 2007;52(3):335-338
We report a patient who developed a hydromediastinum associated with the insertion of a central venous catheter. A 32-year-old male, who presented for left nephroureterectomy, had a central venous catheter inserted after general anesthesia. The patient subsequently showed acute respiratory distress after extubation. His right neck was severely edematous and the chest radiograph revealed a widened mediastinal shadow. The exploratory neck incision showed fluid collection at the neck and mediastinum.
Adult
;
Anesthesia, General
;
Catheterization*
;
Catheters*
;
Central Venous Catheters
;
Humans
;
Jugular Veins*
;
Male
;
Mediastinum
;
Neck
;
Radiography, Thoracic

Result Analysis
Print
Save
E-mail