1.Attitude and treatment options in implant-supported prosthetics: A survey among a cohort of German dentists
Carolin GLÜCKER ; Angelika RAUCH ; Sebastian HAHNEL
The Journal of Advanced Prosthodontics 2020;12(1):15-21
PURPOSE: The aim of the current study was to analyze treatment concepts of a cohort of German dentists for planning, fabrication, and maintenance of implant-supported fixed and removable restorations.MATERIALS AND METHODS: A questionnaire including queries about experiences with implant-supported restorations as well as prosthetic and maintenance treatment concepts for supplying patients with fixed and removable implant-supported prosthetic restorations was developed and sent to 350 dental offices registered in the municipal area of Leipzig, Germany.RESULTS: An overall total of 62 returned questionnaires were included in the analyses, which relates to a response rate of 17.7%. Participating dentists were more involved in the prosthetic aspects of implant dentistry rather than surgery, while prosthetic concepts such as backward planning, digital processing, and application of all-ceramic materials were not commonly performed. Simple attachments were preferred over complex retention systems in removable implant-supported restorations. Tooth/implant-supported fixed denture prostheses as well as removable denture prostheses with supporting posterior implants were not regarded as a favorable treatment option.CONCLUSION: Within the limitations of the study, the data indicate that dentists favor simple and conventional treatment approaches in implant prosthetics. Prosthetic aspects in the planning of implant-supported restorations are often neglected. Prosthetic treatment guidelines and aspects should commonly be considered in the planning phase of implant-supported prosthetic restorations, and awareness should be increased in postgraduate education.
Cohort Studies
;
Crowns
;
Dental Implants
;
Dental Offices
;
Dentistry
;
Dentists
;
Dentures
;
Education
;
Germany
;
Humans
;
Peri-Implantitis
;
Prostheses and Implants
2.The treatment of an edentulous patient with conventional complete denture and CAD/CAM complete denture
The Journal of Korean Academy of Prosthodontics 2020;58(1):42-49
In patients with fully edentulous jaw, treatment of complete dentures should be carried out in many stages when following the conventional methods. Therefore there were disadvantages such as multiple visits to dental clinic is inevitable. In addition, errors caused by polymerization shrinkage, which happens during the fabrication of denture, and difficulties in reproduction of damaged or lost denture were considered as disadvantages. But nowadays, computer-aided design and computer-aided manufacturing (CAD/CAM) system is widely used in dentistry and it has begun to expand its spectrum in manufacturing complete dentures. Using CAD/CAM system to fabricate complete dentures can reduce the number of patient's visit and clinical chair time, since taking impression, recording jaw relation, and selection of artificial teeth are performed at the same time during the first visit, and delivering of dentures during the second visit is possible. In addition, because 3D-Printing technology is used, errors by polymerization shrinkage can be reduced. Among the companies that fabricate complete dentures using CAD/CAM system, DENTCA CAD/CAM denture (DENTCA Inc., Los Angeles, CA, USA) is the most commercialized company. In this case, we treated patients of complete dentures using conventional complete denture method and DENTCA CAD/CAM denture system in the same patient. We would like to report this case because we have achieved good results not only in functional aspects of pronunciation, chewing, and swallowing but also in aesthetic aspects.
Computer-Aided Design
;
Deglutition
;
Dental Clinics
;
Dentistry
;
Denture, Complete
;
Dentures
;
Humans
;
Jaw
;
Jaw, Edentulous
;
Mastication
;
Methods
;
Polymerization
;
Polymers
;
Reproduction
;
Tooth, Artificial
3.Full mouth rehabilitation using removable prosthesis of patient with unstable mandible movements: A case report
Dong Hwan SOHN ; Yang Jin YI ; Deuk Won JO
The Journal of Korean Academy of Prosthodontics 2020;58(1):35-41
Patients with collapsed occlusal support and unilateral chewing show parafunctional mandibular movements, which can be complicated in older patients. Gothic arch tracing and split cast technique are used to confirm the deviation between centric relation and anterior habitual bite in patient who has oral dyskinesia and collapsed occlusion. Temporary denture as occlusal stabilization appliance was provided for stable occlusion and reproducible mandibular movement. Definitive denture was fabricated by lingualized occlusion concept.
Centric Relation
;
Dentures
;
Humans
;
Mandible
;
Mastication
;
Mouth Rehabilitation
;
Mouth
;
Movement Disorders
;
Prostheses and Implants
4.Color stability of three dimensional-printed denture teeth exposed to various colorants
Eun Sol KOH ; Hyun Suk CHA ; Tae Hyung KIM ; Jin Soo AHN ; Joo Hee LEE
The Journal of Korean Academy of Prosthodontics 2020;58(1):1-6
PURPOSE: This study evaluated color stability of Dentca 3D-printed denture teeth, in comparison to color stabilities of four conventional types of denture teeth, upon being immersed in various colorants.MATERIALS AND METHODS: Four types of conventional prefabricated denture teeth (Surpass, GC, Artic 6, Heraeus Kulzer, Premium 6, Heraeus Kulzer, Preference, Candulor), 3D-printed denture teeth (Dentca); and Z250 (Filtek Z250, 3M ESPE) were prepared for testing. The samples were immersed in erythrosine 3%, coffee, cola, and distilled water (DW) at 37℃. Color change (ΔE) was measured by spectrophotometer before immersion and at 7, 14, and 21 days after immersion. One-way analysis of variance was performed along with Tukey's honestly significant difference multiple comparisons test (P<.05).RESULTS: No great difference was observed between the color change of Dentca denture teeth and that of conventional denture teeth in most cases (P>.05). The color change of Dentca denture teeth immersed in erythrosine 3% was greater than that of Surpass (ΔE = 0.67 ± 0.25) after 1 week; Artic 6 (ΔE = 1.44 ± 0.38) and Premium 6 (ΔE = 1.69 ± 0.35) after 2 weeks; and Surpass (ΔE = 1.79 ± 0.49), Artic 6 (ΔE = 2.07 ± 0.21), Premium 6 (ΔE = 2.03 ± 0.75), and Preference (ΔE = 2.01 ± 0.75) after 3 weeks (P<.05).CONCLUSION: A color change was observed in Dentca denture teeth when immersed in some colorants; however, the maximum value of ΔE for Dentca denture teeth was within the clinically acceptable range.
Coffee
;
Cola
;
Dentures
;
Erythrosine
;
Immersion
;
Printing, Three-Dimensional
;
Tooth
;
Water
5.Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method
Suji LEE ; Seoung Jin HONG ; Janghyun PAEK ; Ahran PAE ; Kung Rock KWON ; Kwantae NOH
The Journal of Advanced Prosthodontics 2019;11(1):55-64
PURPOSE: The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS: The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at α=.05. RESULTS: No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P < .05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P < .05). CONCLUSION: The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.
Denture Bases
;
Dentures
;
Fungi
;
Methods
;
Printing, Three-Dimensional
;
Sutures
6.Physical properties and color stability of injection-molded thermoplastic denture base resins
So Yeon SONG ; Kyoung Soo KIM ; Jeong Yol LEE ; Sang Wan SHIN
The Journal of Advanced Prosthodontics 2019;11(1):32-40
PURPOSE: The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS: In this study, six commercially available products (VA; Valplast, LC; Lucitone, ST; Smiltone, ES; Estheshot-Bright, AC; Acrytone, WE; Weldenz) were selected from four types of thermoplastic denture base materials (Polyamide, Polyester, Acrylic resin and Polypropylene). The flexural properties and shore D hardness have been investigated and water sorption and solubility, and color stability have evaluated. RESULTS: For the flexural modulus value, ES showed the highest value and WE showed significantly lower value than all other groups (P < .05). Most of experimental groups showed weak color stability beyond the clinically acceptable range. CONCLUSION: Within the limits of this study, thermoplastic denture base resin did not show sufficient modulus to function as a denture base. In addition, all resins showed discoloration with clinical significance, and especially polyamides showed the lowest color stability.
Denture Bases
;
Dentures
;
Hardness
;
Nylons
;
Polyesters
;
Solubility
;
Water
7.Complete denture made with closed-mouth impression technique on severely atrophied edentulous jaw
Suk Hwan LEE ; Richard LEESUNGBOK ; Suk Won LEE
The Journal of Korean Academy of Prosthodontics 2019;57(2):195-202
At the department of prosthodontics, the elderly patients with severely atrophied alveolar ridge who have been wearing complete dentures for a long period frequently visit the clinic. In general, the open-mouth impression technique for manufacturing a mandibular complete denture to secure primary support on buccal shelf area has been prevalent. In addition, for securing retention and stability of mandibular denture, we should consider diagnosis, oral function, denture border, occlusal plane, teeth arrangement, and patient training, etc.. But in edentulous patients with severe alveolar bone atrophy, it may hardly secure retention and stability of mandibular complete denture. To promote these, some of clinicians are making an attempt manufacturing the mandibular complete dentures using closed-mouth impression technique based on several reports that compare various impression techniques including open-mouth and closed-mouth impression technique. This case report suggests closed-mouth impression technique may promote retention and stability of mandibular complete denture and compares between the two impression techniques clinically.
Aged
;
Alveolar Bone Loss
;
Alveolar Process
;
Dental Occlusion
;
Denture, Complete
;
Dentures
;
Diagnosis, Oral
;
Humans
;
Jaw, Edentulous
;
Prosthodontics
;
Tooth
8.Implant-assisted removable partial denture for severely atrophied mandible
Bada CHOI ; Yeun Ju KIM ; Jae Hoon LEE
The Journal of Korean Academy of Prosthodontics 2019;57(2):171-175
Mandible with severe alveolar bone atrophy poses a significant challenge in terms of reproducing clinically acceptable anatomy for a removable prosthesis. To overcome this potential complication, altered cast impression technique is often recommended to capture accurate and functional gingiva tissues. It becomes possible to get proper anchors functional impression by placing 2 implants crowns which were impossible in previous implant overdenture impression technique. In this case, an 80-year old female patient with severe mandibular ridge atrophy was treated with an implant-assisted removable partial denture with two implant crowns on the canine area. An altered cast impression was taken with an individual tray on a metal framework of removable partial denture on both posterior edentulous areas. The patient was satisfied with the final prosthesis after failure of 2 previous prostheses. Clinician had a difficult time to manage disabled patient and patient were suffered with ill-fitting denture due to inaccurate impression in conventional overdenture condition. The oral rehabilitation was completed with placing 2 implants as proper anchor.
Alveolar Bone Loss
;
Atrophy
;
Crowns
;
Denture, Overlay
;
Denture, Partial, Removable
;
Dentures
;
Female
;
Gingiva
;
Humans
;
Mandible
;
Prostheses and Implants
;
Rehabilitation
9.Rehabilitation of mandibular edentulous patients with a few unilateral remaining teeth using implant-assisted removable partial denture: A case report.
Bhumgey David LEE ; Yong Sang LEE
The Journal of Korean Academy of Prosthodontics 2019;57(1):42-48
In the case of a patient with a small number of unilateral remaining teeth in the mandible, a restoration with conventional removable partial denture cannot provide sufficient retention and resistance. A harmful stress from the poor stability of denture on remaining teeth occurs due to alveolar bone resorption in edentulous area. Although implant fixed prosthesis can provide multiple benefits over conventional removable partial denture, there are limitations come from anatomic structures and costs. In this case, an implant-assisted removable partial denture (IARPD) with a couple of implants placed in strategic positions can be a treatment modality. The objective of this article is to present a case report of two patients showed satisfactory clinical outcomes during three-year follow-up period describing the fabrication and advantages of removable partial denture assisted by teeth and implants (IARPD) for a patient with a small number of unilateral remaining teeth in mandible using Locator as an implant attachment.
Bone Resorption
;
Denture, Partial, Removable*
;
Dentures
;
Follow-Up Studies
;
Humans
;
Mandible
;
Prostheses and Implants
;
Rehabilitation*
;
Tooth*
10.Interalveolar ridge crest relation analysis and rehabilitation of edentulous patient using dental CAD software: A case report.
Youngsun HONG ; Jong Eun KIM ; June Sung SHIM
The Journal of Korean Academy of Prosthodontics 2019;57(1):31-36
As the number of elderly population increases, the proportion of edentulous patients is increasing, and the demand for traditional dentures will also increase. Arranging the artificial teeth according to the relationship and shape of the upper and lower alveolar ridge is an important factor increasing the stability of the denture. This case is a 79 year old female patient who wishes to make denture covered by national health insurance for psychological and economical reasons. With the alveolar bone severely atrophic, the dental CAD software was used for accurate diagnosis and the posterior teeth were arranged in a cross bite according to the interalveolar crest line angle by the program. After completion, the denture showed adequate stability and maintenance in periodic examinations and treatment, and the patient also expressed high satisfaction.
Aged
;
Alveolar Process
;
Denture, Complete
;
Dentures
;
Diagnosis
;
Female
;
Humans
;
Malocclusion
;
National Health Programs
;
Rehabilitation*
;
Tooth
;
Tooth, Artificial

Result Analysis