1.Design and application of a B-ultrasound-guided deep vein puncture precise positioning device.
Qiaoqiao PENG ; Xiangying YANG ; Yuan LI ; Weiying DAI ; Jianrong WANG
Chinese Critical Care Medicine 2023;35(10):1099-1100
Deep venipuncture catheterization is a routine and basic operation in the treatment of critically ill patients, and it is the most effective way to quickly correct the shock. Clinical B-ultrasound guided deep vein catheters can improve the success rate of puncture, but in the process of operation, the short axis needs to be replaced by the long axis. In the replacement process, the stability of the novice is insufficient, the positioning is difficult, and the operation time is too long. If only short axis puncture is used, it is impossible to know whether the current position of the puncture needle, and the puncture may be too deep and stray into the artery. The accuracy of the 45 degree angle of the injection point requires a very experienced operator. In view of the above shortcomings, doctors in the department of critical care medicine of Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine designed a B-ultrasound puncture equipment, which has obtained the National Invention Patent of China (ZL 2016 1 0571557.X). The device is composed of B-ultrasound probe fixing frame, sliding scale plate, simulation slide rule, puncture needle, sliding device. By sliding device the angle of the pinhole channel, it is conducive to the accurate positioning of the puncture target, optimizing the operation procedure, improving the puncture speed and accuracy, effectively reducing the occurrence of puncture complications, ensuring patient safety, reducing unnecessary waste of human and material resources. It can reduce the workload of medical staff and is worthy of clinical practice.
Humans
;
Catheterization, Central Venous/methods*
;
Ultrasonography, Interventional/methods*
;
Ultrasonography
;
Punctures/methods*
;
Needles
2.Surgical complications of totally implantable venous access port in children with malignant tumors.
Hui LI ; Yang Xu GAO ; Shu Lei WANG ; Hong Xin YAO
Journal of Peking University(Health Sciences) 2022;54(6):1167-1171
OBJECTIVE:
To summarize the surgical experience of totally implantable venous access port in children with malignant tumors, and to explore the coping methods of surgical complications.
METHODS:
The clinical data of 165 children with malignant tumors implanted in totally implantable venous access port in Department of Pediatric Surgery, Peking University First Hospital from January 2017 to December 2019 were retrospectively analyzed. The operation process, complications and treatment of complications were observed and counted.
RESULTS:
The children in this group were divided into external ju-gular vein incision group (n=27) and internal jugular vein puncture group (n=138) according to different surgical methods, and the latter was divided into ultrasound guided puncture group (n=95) and blind puncture group (n=43). No puncture complications occurred in the external jugular vein incision group, and the average time for successful catheterization and the number of times for catheter to enter the superior vena cava were more than those in the internal jugular vein puncture group [(9.26±1.85) min vs. (5.76±1.56) min, (1.93±0.87) times vs. 1 time], with statistical significance. The average time of successful catheterization, the success rate of one puncture, the average number of punctures and the incidence of puncture complications in the ultrasound guided right internal jugular vein puncture group were better than those in the blind puncture group [(5.36±1.12) min vs. (6.67±1.99) min, 93.68% (89/95) vs. 74.42% (32/43), (1.06±0.24) times vs. (1.29±0.55) times, 2.11% (2/95) vs. 11.63% (5/43)], with statistically significant differences. The total incidence of complications in this study was 12.12% (20/165). Pneumothorax occurred in 1 case, artery puncture by mistake in 1 case, local hematoma in 5 cases, venous access port related infection in 4 cases (venous access port local infection in 2 cases, catheter related blood flow infection in 2 cases), subcutaneous tissue thinning on the surface of port seat in 2 cases, port seat overturning in 1 case, poor transfusion in 4 cases (catheter discount in 1 case, catheter blockage in 3 cases), and foreign bodies gathered around the subcutaneous pipeline in 2 cases. There were no complications, such as catheter rupture, detachment and catheter clamping syndrome.
CONCLUSION
Totally implantable venous access port can provide safe and effective infusion channels for children with malignant tumors. Right external jugular vein incision and ultrasound-guided right internal jugular vein puncture are reliable surgical methods for children's totally implantable venous access port implantation. Surgeons should fully understand the complications of the venous access port, take measures to reduce the occurrence of complications, and properly handle the complications that have occurred.
Humans
;
Child
;
Catheterization, Central Venous/methods*
;
Retrospective Studies
;
Vena Cava, Superior
;
Jugular Veins/surgery*
;
Neoplasms/surgery*
3.Prevention from PICC-related venous thrombosis in the upper limbs of malignant tumor patients with moxibustion combined with plucking at Jiquan (HT 1): a randomized controlled trial.
Ling QIU ; Xiao-Yi LIANG ; Yu-Ling ZHENG ; Chun-Xiang LIU ; Xiao-Qing LAI ; Li-Ying ZHU
Chinese Acupuncture & Moxibustion 2022;42(7):741-746
OBJECTIVE:
To observe the clinical effect of moxibustion combined with plucking technique at Jiquan (HT 1) for preventing peripherally inserted central catheter (PICC)-related venous thrombosis in the upper limbs of malignant tumor patients.
METHODS:
A total of 80 malignant tumor patients undergoing PICC were randomized into an observation group and a control group, 40 cases in each one. In the control group, the routine care for PICC was exerted. In the observation group, besides the routine care, moxibustion combined with plucking technique at Jiquan (HT 1) was added. Mild moxibustion was exerted along the venous distribution of PICC (avoiding the entry site) for 10 to 15 min, and then, the circling moxibustion was applied to Quchi (LI 11), Xuehai (SP 10) and Tianfu (LU 3), 3 to 5 min at each acupoint. Finally, plucking technique was given at Jiquan (HT 1) for 5 to 10 min. This combined therapy was intervened since the 2nd day of PICC placement, once daily, 5 times a week, for 3 weeks totally. The incidence of the PICC-related venous thrombosis in the upper limbs was compared between the two groups on day 42 of placement. On day 2, 7, 14, 21, 28, 35 and 42 of PICC placement, the peak systolic velocity (PSV) and the end-diastolic velocity (EDV) of the subclavicular vein on the placement side were observed separately in the two groups.
RESULTS:
The incidence of the PICC-related venous thrombosis in the upper limbs in the observation group was lower than that in the control group (2.5% [1/40] vs 17.5% [7/40], P<0.05). From day 7 to 35 of PICC placement, PSV of the subclavicular vein on the placement side was higher than that on the day 2 of PICC placement in the observation group (P<0.05). On day 28 and 42 of PICC placement, PSV of the subclavicular vein on the placement side was lower than that on the day 2 of PICC placement in the control group (P<0.05). In the observation group, EDV of the subclavicular vein on the placement side was higher than that on the day 2 of PICC placement from day 7 to 28 of PICC placement (P<0.05). In the control group, EDV of the subclavicular vein on the placement side from day 28 to 42 of PICC placement was lower than that on the day 2 of PICC placement (P<0.05). From day 7 to 42 of PICC placement, PSV and EDV of the subclavicular vein on the placement side in the observation group were all higher than those in the control group (P<0.01, P<0.05).
CONCLUSION
The combined treatment of moxibustion with plucking technique at Jiquan (HT 1) can effectively prevent PICC-related venous thrombosis in the upper limbs and improve venous blood flow velocity in malignant tumor patients.
Catheterization, Central Venous/methods*
;
Catheterization, Peripheral/adverse effects*
;
Humans
;
Moxibustion/adverse effects*
;
Neoplasms/complications*
;
Upper Extremity
;
Venous Thrombosis/etiology*
4.Clinical Characteristics of Peripherally Inserted Central Catheter in Critically Ill Patients
Hyoung Joo KIM ; Chang Yeon JUNG ; Jung Min BAE
Journal of Acute Care Surgery 2019;9(1):18-24
PURPOSE: Ensuring the stability of central venous catheter placement for treating patients hospitalized in an intensive care unit is very important. Although PICC requires an ultrasound and fluoroscopy machine, it is difficult to use a fluoroscopy machine for PICC insertion in the intensive care unit. This study analyzed the cases of the insertion of a PICC under ultrasonic guidance at the bedsides in the intensive care unit to determine the usefulness of PICC in the intensive care unit. METHODS: A retrospective study was conducted on patients hospitalized in the surgical intensive care unit and received PICC using ultrasonography at their bedsides from October 2015 to January 2018. RESULTS: One hundred and twenty patients were collected. The number of successful PICCs stood at 105 patients, which was equal to 87.5%. Among them, 65 and 55 cases had left and right insertion, respectively; the corresponding success rate was 81.8%, and 92.3%. No statistically significant difference in success rates was observed between the left and right, as well as in the success rates depending on the presence of shock, sepsis, acute kidney injury, and mechanical ventilation. In the failed 15 cases, seven cases were due to the course of the procedure and eight cases were confirmed have been malpositioned after insertion. CONCLUSION: PICC at the bedside in an intensive care unit is a safe method for central venous catheterization without severe complications and death. The insertion sites, left or right, are equally acceptable. Further study of the cases of malposition will be necessary.
Acute Kidney Injury
;
Catheterization
;
Catheterization, Central Venous
;
Catheters
;
Central Venous Catheters
;
Critical Care
;
Critical Illness
;
Fluoroscopy
;
Humans
;
Intensive Care Units
;
Methods
;
Respiration, Artificial
;
Retrospective Studies
;
Sepsis
;
Shock
;
Ultrasonics
;
Ultrasonography
5.Efficiency of electrocardiogram monitor for positioning the catheter tip in peripherally inserted central catheter placement in neonates.
Qi-Ying LING ; Hong CHEN ; Min TANG ; Yi QU ; Bin-Zhi TANG
Chinese Journal of Contemporary Pediatrics 2018;20(5):363-367
OBJECTIVETo study the efficiency of electrocardiogram (ECG) monitor for positioning the catheter tip in the placement of peripherally inserted central catheter (PICC) in neonates.
METHODSA total of 160 neonates who were admitted to the neonatal intensive care unit (NICU) from January 2015 to December 2017 and underwent the PICC placement via the veins of upper extremity were enrolled. They were randomly divided into an observation group and a control group, with 80 neonates in each group. The neonates in the control group were given body surface measurement and postoperative X-ray localization, while those in the observation group were given body surface measurement, ECG localization, and postoperative X-ray localization. The two groups were compared in terms of general information, one-time success rate of PICC placement, and time spent on PICC placement.
RESULTSThere were no significant differences between the two groups in sex composition, gestational age, age in days at the time of PICC placement, disease type, and site of puncture (P>0.05). Compared with the control group, the observation group had a significantly higher one-time success rate of PICC placement (95% vs 79%; P<0.05) and a significantly shorter time spent on PICC placement (P<0.05). Localization under an ECG monitor during PICC placement had a sensitivity of 97% and a specificity of 100%.
CONCLUSIONSDuring the PICC placement in neonates, the use of ECG monitor to determine the position of catheter tip can improve the one-time success rate of placement and reduce the time spent on placement.
Catheterization, Central Venous ; instrumentation ; Catheterization, Peripheral ; methods ; Catheters, Indwelling ; Electrocardiography ; instrumentation ; Female ; Humans ; Infant, Newborn ; Male
6.The method to reduce the malposition rate via reposition of guidewire with ultrasound guidance in the central venous catheterization.
Taewook KANG ; Sunguk CHO ; Hongjoon AHN ; Jinhong MIN ; Wonjoon JEONG ; Seung RYU ; Segwang OH ; Seunghwan KIM ; Yeonho YOU ; Jinwoong LEE ; Jungsoo PARK ; Insool YOO ; Yongchul CHO
Journal of the Korean Society of Emergency Medicine 2018;29(4):364-370
OBJECTIVE: Malposition of central venous catheterization (CVC) may cause vascular related complications and catheter dysfunctions. The aim of this study was to reduce the malposition rate of CVC by repositioning the malposition after confirming the location of the guide-wire with ultrasound (US) guidance. METHODS: This research assessed the before study (group A) from January to December 2016 and after study (group B) from January to December 2017 in the emergency department. CVCs were performed using the anatomical landmark technique (group A) and US guided technique (group B). In group B, if the guided-wire was misplaced, it was drawn back and repositioned under US guidance. The final location of the catheter tip was confirmed by chest X-ray. The rate of malposition before and after repositioning of the two groups was compared. RESULTS: The subjects were group A (694 cases) and group B (619 cases) with a total of 1,313 patients. The rate of malposition before repositioning of the two groups were 16 cases (2.3%) and 13 cases (2.1%), respectively, and no statistically significant difference was observed (P>0.05). In group B, there were 10 cases (1.6%) of guidewire malposition that was identified and three cases (0.5%) of catheter malposition could not be identified under US examination. The malpositioned guidewires were all corrected by repositioning under ultrasound guidance. The rate of malposition after repositioning of the two groups were 2.3% (n=16) and 0.5% (n=3), respectively, and a statistically significant difference was observed (P=0.009). CONCLUSION: With US guidance, confirming the location and repositioning CVC guidewire can reduce the malposition rate in CVCs.
Catheterization, Central Venous*
;
Catheters
;
Central Venous Catheters*
;
Emergency Service, Hospital
;
Humans
;
Methods*
;
Moving and Lifting Patients
;
Thorax
;
Ultrasonography*
7.Tension hydrothorax induced by malposition of central venous catheter: A case report.
Seunghee KI ; Myoung hun KIM ; Wonjin LEE ; Hakmoo CHO
Anesthesia and Pain Medicine 2017;12(2):151-154
Central venous catheterization is a useful method for monitoring central venous pressure and maintaining volume status. However, it is associated with several complications, such as pneumothorax, hydrothorax, hemothorax, and air embolism. Here we describe a case of iatrogenic tension hydrothorax after rapid infusion of fluid into the pleural space, following the misplacement of an internal jugular vein catheter. Despite ultrasonographic guidance during insertion of the central venous catheter, we were not able to avoid malposition of the catheter. The patient went into hemodynamic compromise during surgery, necessitating chest tube drainage and a mechanical ventilator postoperatively. This case shows that central venous catheter insertion under ultrasonographic guidance does not guarantee proper positioning of the catheter.
Catheterization, Central Venous
;
Catheters
;
Central Venous Catheters*
;
Central Venous Pressure
;
Chest Tubes
;
Drainage
;
Embolism, Air
;
Hemodynamics
;
Hemothorax
;
Humans
;
Hydrothorax*
;
Jugular Veins
;
Methods
;
Pneumothorax
;
Ventilators, Mechanical
8.Optimal head rotation and puncture site for internal jugular vein cannulation after laryngeal mask airway insertion.
Won Ho KIM ; Mi Sook GWAK ; Soo Joo CHOI ; Sang Hoon SONG ; Myung Hee KIM
Singapore medical journal 2015;56(8):472-478
INTRODUCTIONWe studied the effect of head rotation on the relative position of the right common carotid artery (CCA) and the right internal jugular vein (IJV) in patients with laryngeal mask airway (LMA) insertion to evaluate the accuracy of anatomical landmarks for right IJV cannulation.
METHODSWe simulated needle insertion to the right IJV on sonograms via the central landmark approach and an approach using the external jugular vein, in patients with LMA insertion (n = 50) or endotracheal intubation (E-tube, n = 50). Overlap index and successful simulation rates were measured according to the different degrees of head rotation.
RESULTSThe overlap index between the right CCA and the right IJV increased with greater degrees of head rotation. It was significantly greater in the LMA insertion group than in the E-tube group in the following head rotation positions: neutral, 15° and 45°. The success rate of the simulation was lower in the LMA insertion group than in the E-tube group. In the LMA insertion group, the success rate of the simulation was highest (62%) with the central landmark approach and in the 15° head rotation position.
CONCLUSIONIn the LMA insertion group, the overlap index increased incrementally with greater head rotation degrees (from neutral to 45°). The central landmark approach and 15° head rotation position appear to be the optimal puncture site and degree of head rotation for right IJV cannulation in patients with LMA insertion.
Adult ; Anesthesia, General ; methods ; Carotid Artery, Common ; anatomy & histology ; diagnostic imaging ; Catheterization, Central Venous ; methods ; Computer Simulation ; Female ; Head ; diagnostic imaging ; physiology ; Humans ; Jugular Veins ; anatomy & histology ; diagnostic imaging ; Laryngeal Masks ; Male ; Middle Aged ; Needles ; Patient Positioning ; methods ; Prospective Studies ; Punctures ; Rotation ; Ultrasonography
9.Impact of infection control training for interns on PICU-acquired bloodstream infections in a middle-income country.
Yun Yun NG ; Mohamed El-Amin ABDEL-LATIF ; Chin Seng GAN ; Anis SIHAM ; Hasimah ZAINOL ; Lucy Chai See LUM ;
Singapore medical journal 2015;56(9):506-512
INTRODUCTIONThe present study aimed to determine the impact of an extended infection control training programme, which was conducted for all interns posted to the Department of Paediatrics, on the incidence of paediatric intensive care unit (PICU)-acquired bloodstream infections (BSIs) in University Malaya Medical Centre, Malaysia.
METHODSThe development of nosocomial BSIs during the baseline period (1 January-31 October 2008) and intervention period (1 November-31 December 2009) was monitored. During the intervention period, all paediatric interns underwent training in hand hygiene and aseptic techniques for accessing vascular catheters.
RESULTSA total of 25 patients had PICU-acquired BSIs during the baseline period, while 18 patients had PICU-acquired BSIs during the intervention period (i.e. infection rate of 88 per 1,000 and 41 per 1,000 admissions, respectively). The infections were related to central venous catheters (CVCs) in 22 of the 25 patients who had PICU-acquired BSIs during the baseline period and 11 of the 18 patients who had PICU-acquired BSIs during the intervention period. Thus, the incidence rates of catheter-related BSIs were 25.2 per 1,000 CVC-days and 9.3 per 1,000 CVC-days, respectively (p < 0.05). The Paediatric Risk of Standardised Mortality III score was an independent risk factor for PICU-acquired BSIs and the intervention significantly reduced this risk.
CONCLUSIONThe education of medical interns on infection control, a relatively low-cost intervention, resulted in a substantial reduction in the incidence of PICU-acquired BSIs.
Catheter-Related Infections ; prevention & control ; Catheterization, Central Venous ; adverse effects ; Catheters, Indwelling ; adverse effects ; Central Venous Catheters ; adverse effects ; Child, Preschool ; Cross Infection ; prevention & control ; Female ; Hand Hygiene ; Humans ; Infant ; Infection Control ; methods ; Intensive Care Units, Pediatric ; Internship and Residency ; Malaysia ; Male ; Pediatrics ; education ; Proportional Hazards Models
10.Percutaneous Suture-Based Closure Device for Management of Inadvertent Subclavian Artery Catheterization.
Seong Soo LEE ; Jaehoon KO ; Kyung Suk LIM ; Beomsu SHIN ; Ga Yeon LEE ; Seung Hyuk CHOI
Korean Journal of Medicine 2014;87(2):200-204
Central venous catheterization is performed to secure pathways for large amounts of saline, drug infusion, parenteral nutrition support, and hemodialysis. Accidental subclavian artery cannulation is a possible complication of central venous catheterization. Here, we report two cases of 8 Fr. chemoports inadvertently inserted in subclavian arteries during internal jugular venous catheterizations. The chemoports were removed successfully, and puncture sites were repaired using suture-based closure devices (Perclose). One patient experienced minor neurological complications after the procedure. With effective management, the patient was treated with no sequelae. To our knowledge, this is the first report of stroke after procedures using suture-based devices.
Catheterization*
;
Catheterization, Central Venous
;
Catheters*
;
Central Venous Catheters
;
Humans
;
Infusions, Parenteral
;
Methods
;
Punctures
;
Renal Dialysis
;
Stroke
;
Subclavian Artery*

Result Analysis
Print
Save