1.Feasibility study of immediate breast reconstruction with fusion fascia combined with implants.
Zu Jin CHEN ; Ao Xiang CHEN ; Bin ZHANG ; Xin WANG ; Xu Chen CAO
Chinese Journal of Oncology 2023;45(6):514-518
Objective: To investigate the oncologic and surgical safety of the fused fascia method for immediate breast reconstruction with implants. Methods: The clinical data of 343 patients with immediate breast reconstruction with implants in Tianjin Medical University Cancer Hospital from 2014-2017 were retrospectively analyzed to compare the 5-year local recurrence-free survival, 5-year disease-free survival and 5-year overall survival of patients with breast reconstruction by fusion fascia and other methods, and to analyze the complication incidences of implant removal between different implant groups. Results: Of the 343 patients with breast reconstruction, 95 were in the fused fascia group (fascia group) and 248 were in the non-fascia group (25 in the bovine pericardial patch group and 223 in the muscle flap group). At a median follow-up of 49 months, the differences in 5-year local recurrence-free survival (90.1% and 94.9%, respectively), 5-year disease-free survival (89.2% and 87.6%, respectively), and 5-year overall survival (95.2% and 95.1%, respectively) between patients in the fascial and non-fascial groups were not statistically significant (P>0.05). The complication incidence of implant removal was 24.0% (6/25) in the patch group and 2.1% (2/95) and 2.2% (5/223) in the fascia and muscle flap groups, respectively. Conclusion: Immediate breast reconstruction with fused fascial combined with implant is safe and feasible, less invasive than muscle flaps, more economical and with fewer complications than patches.
Humans
;
Animals
;
Cattle
;
Female
;
Mastectomy/methods*
;
Retrospective Studies
;
Breast Implants/adverse effects*
;
Feasibility Studies
;
Mammaplasty/methods*
;
Breast Neoplasms/complications*
;
Treatment Outcome
;
Postoperative Complications/surgery*
2.Application of acellular bovine pericardium patch in implant based immediate breast reconstruction.
Bo Wen DING ; Hui Qing WANG ; Shan Shan HE ; Shu WANG ; Qing Feng HUANG ; Chun Yong HAN ; Jing LIU ; Zhu Ming YIN ; Jing Yan SUN ; Yan WANG ; Jian YIN
Chinese Journal of Surgery 2022;60(3):237-243
Objective: To examine the clinical effect of acellular bovine pericardium patch in implant based immediate breast reconstruction. Methods: The clinicopathological information of 141 breast cancer patients, who admitted to Department of Breast Reconstruction and Oncoplastic Surgery, Tianjin Medical University Cancer Hospital, underwent immediate mammoplasty with implants combined with acellular bovine pericardium patches were analyzed from June 2016 to October 2019. All patients were female, with the age of (38.8±8.5) years (range: 13 to 60 years). The body mass index was (21.9±2.5) kg/m2 (range: 16.0 to 32.3 kg/m2). There were 39 cases of duct carcinoma in situ, 46 cases of stage Ⅰ, 40 cases of stage Ⅱ and 16 cases of stage Ⅲ. All patients received nipple-areola-sparing mastectomy or skin-sparing mastectomy with sentinel lymph node biopsy or axillary lymph node dissection, and prosthesis implantation with sub-pectoralis combined with breast patch. The correlation of clinicopathological characters and complications was assessed by t test, χ2 test, Fisher's exact probability method and Logistic regression. Pre-and post-operative aesthetic, quality of life scores were recorded. Results: The operation time (M(IQR)) was 3.6(1.5) hours (range: 3.0 to 6.5 hours). The early postoperative complication rate was 22.0% (31/141), prosthesis removal was the main postoperative complication, accounting for 64.5% (20/31) of the total complications, of which 15 cases occurred in the first 30 patients. The follow-up time was 28(8) months (range: 20 to 53 months), The most frequent long-term complications were capsular contracture and implant displacement, with the incidence of 11.2% (14/125) and 10.4% (13/125), respectively. Multivariate analysis showed that prosthesis volume ≥300 ml (OR=8.173, 95%CI: 1.302 to 51.315, P=0.021) and peri-areolar incision (OR=7.809, 95%CI: 2.162 to 28.211, P<0.01) were independent relative factors for the occurrence of short-term postoperative local complications. After 2 years of operation, the score of breast appearance satisfaction was 71.7±15.5, postoperative effect satisfaction was 90.4±9.5, psychological satisfaction was 90.7±17.1, sexual satisfaction was 70.1±25.1. The immediate postoperative satisfaction rate at discharge was 95.4% (134/141), and 17.6% (22/125) of patients had the intention to received revision surgery. Conclusions: Prosthesis volume ≥300 ml and peri-areolar incision were independent realtive factors for short-term local complications after bovine pericardium patch combined with prosthesis implantation in the immediate breast reconstruction. After completing the learning curve, the postoperative complications of the procedure could be decreased.
Adolescent
;
Adult
;
Animals
;
Breast Implantation
;
Breast Implants
;
Breast Neoplasms/surgery*
;
Cattle
;
Female
;
Humans
;
Mammaplasty/methods*
;
Mastectomy/methods*
;
Middle Aged
;
Pericardium/surgery*
;
Quality of Life
;
Retrospective Studies
;
Young Adult
3.Early experiences with robot-assisted prosthetic breast reconstruction
Sung Jae AHN ; Seung Yong SONG ; Hyung Seok PARK ; Se Ho PARK ; Dae Hyun LEW ; Tai Suk ROH ; Dong Won LEE
Archives of Plastic Surgery 2019;46(1):79-83
Robotic surgery facilitates surgical procedures by employing flexible arms with multiple degrees of freedom and providing high-quality 3-dimensional imaging. Robot-assisted nipplesparing mastectomy with immediate reconstruction is currently performed to avoid breast scars. Four patients with invasive ductal carcinoma underwent robot-assisted nipple-sparing mastectomy and immediate robot-assisted expander insertion. Through a 6-cm incision along the anterior axillary line, sentinel lymph node biopsy and nipple-sparing mastectomy were performed by oncologic surgeons. The pectoralis major muscle was elevated, an acellular dermal matrix (ADM) sling was created with robotic assistance, and an expander was inserted into the subpectoral, sub-ADM pocket. No patients had major complications such as hematoma, seroma, infection, capsular contracture, or nipple-areolar necrosis. The mean operation time for expander insertion was 1 hour and 20 minutes, and it became shorter with more experience. The first patient completed 2-stage prosthetic reconstruction and was highly satisfied with the unnoticeable scar and symmetric reconstruction. We describe several cases of immediate robot-assisted prosthetic breast reconstruction. This procedure is a feasible surgical option for patients who want to conceal surgical scars.
Acellular Dermis
;
Arm
;
Breast Implants
;
Breast
;
Carcinoma, Ductal
;
Cicatrix
;
Contracture
;
Female
;
Freedom
;
Hematoma
;
Humans
;
Mammaplasty
;
Mastectomy
;
Necrosis
;
Robotic Surgical Procedures
;
Sentinel Lymph Node Biopsy
;
Seroma
;
Surgeons
;
Tissue Expansion Devices
4.Prepectoral breast reconstruction
Yeungnam University Journal of Medicine 2019;36(3):201-207
Implant-based breast reconstruction is the most commonly used reconstruction technique after mastectomy. This is because skin-sparing mastectomy has become possible with advancements in oncology. In addition, the development of breast implants and the advent of acellular dermal matrices have reduced postoperative complications and resulted in superior cosmetic results. The most frequently performed surgical breast reconstruction procedure for the past 20 years was the insertion of an implant under the pectoralis major muscle by means of the dual plane approach. However, some patients suffered from pain and animation deformity caused by muscle manipulation. Recently, a prepectoral approach has been used to solve the above problems in select patients, and the results are similar to subpectoral results. However, this technique is not always chosen due to the number of considerations for successful surgery. In this article, we will discuss the emergence of prepectoral breast reconstruction, indications and contraindications, surgical procedures, and outcomes.
Acellular Dermis
;
Breast Implants
;
Breast
;
Congenital Abnormalities
;
Female
;
Humans
;
Mammaplasty
;
Mastectomy
;
Postoperative Complications
5.Immediate Breast Reconstruction Does Not Have a Clinically Significant Impact on Adjuvant Treatment Delay and Subsequent Survival Outcomes
Seung Ho BAEK ; Soon June BAE ; Chang Ik YOON ; So Eun PARK ; Chi Hwan CHA ; Sung Gwe AHN ; Young Seok KIM ; Tai Suk ROH ; Joon JEONG
Journal of Breast Cancer 2019;22(1):109-119
PURPOSE: The use of immediate breast reconstruction (IBR) has been debated because it may be a causative factor in adjuvant treatment delay and may subsequently increase the probability of recurrence. We investigated whether IBR was related to adjuvant treatment delay and survival outcomes. METHODS: We retrospectively analyzed the duration from operation to adjuvant treatment administration and survival outcomes according to IBR status among patients with breast cancer who underwent mastectomy followed by adjuvant chemotherapy from January 2005 to December 2014. Propensity score matching was performed to balance the clinicopathologic baseline characteristics between patients who did and did not undergo IBR. RESULTS: Of 646 patients, 107 (16.6%) underwent IBR, and the median follow-up was 72 months. The median duration from surgery to adjuvant chemotherapy was significantly longer in patients who underwent IBR than in those who did not (14 vs. 12 days, respectively, p = 0.008). Based on propensity score matching, patients who underwent IBR received adjuvant therapy 3 days later than those who did not (14 vs. 11 days, respectively, p = 0.044). The duration from surgery to post-mastectomy radiation therapy (PMRT) did not significantly differ between the 2 groups. Local recurrence-free survival, regional recurrence-free survival, systemic recurrence-free survival, and overall survival were also not significantly different between the 2 groups (p = 0.427, p = 0.445, p = 0.269, and p = 0.250, respectively). In the case-matched cohort, survival outcomes did not change. CONCLUSION: IBR was associated with a modest increase in the duration from surgery to chemotherapy that was statistically but not clinically significant. Moreover, IBR had no influence on PMRT delay or survival outcomes, suggesting that it is an acceptable option for patients with non-metastatic breast cancer undergoing mastectomy.
Breast Implants
;
Breast Neoplasms
;
Breast
;
Chemotherapy, Adjuvant
;
Cohort Studies
;
Drug Therapy
;
Female
;
Follow-Up Studies
;
Humans
;
Mammaplasty
;
Mastectomy
;
Propensity Score
;
Radiotherapy, Adjuvant
;
Recurrence
;
Retrospective Studies
6.Factors affecting mastectomy specimen density in direct-to-implant breast reconstruction
Hyung Suk YI ; Seok Kyung IN ; Ho Sung KIM ; Jin Hyung PARK ; Hong Il KIM ; Chang Wan JEON ; Hyo Young KIM
Archives of Aesthetic Plastic Surgery 2019;25(4):137-141
BACKGROUND: Direct-to-implant breast reconstruction following nipple-sparing mastectomy is becoming increasingly common. The weight of the breast specimen informs implant selection. However, specimens of the same weight may have different volume. Therefore, identifying the factors affecting the density of breast specimens may facilitate the selection of implants with an appropriate volume. METHODS: From December 2015 to May 2018, 108 patients underwent direct-to-implant reconstruction following nipple-sparing mastectomy. The weight of the breast specimens was measured using an electronic scale in the operating room. Furthermore, the volume of specimens was measured using the water displacement technique. Multiple regression analysis was performed on factors that can affect breast density, such as menopause, neoadjuvant chemotherapy (CTx), age, body mass index, and diabetes mellitus. RESULTS: The average density of breast specimens in patients older than 50 years (n=36) was 0.96±0.04 g/mL, which was significantly lower than the 1.01±0.08 g/mL observed in patients younger than 50 years (n=72) (P=0.007). The mean density of breast specimens in patients who underwent neoadjuvant CTx (n=25) was 0.96±0.06 g/mL, which was significantly lower than the value of 1.00±0.08 g/mL in those who did not (n=83). CONCLUSIONS: It is advisable to select an implant slightly larger than the mastectomy specimen weight in patients older than 50 years or in those who have undergone neoadjuvant CTx.
Body Mass Index
;
Breast Implants
;
Breast
;
Diabetes Mellitus
;
Drug Therapy
;
Female
;
Humans
;
Mammaplasty
;
Mastectomy
;
Menopause
;
Operating Rooms
;
Water
7.A comparative study between sterile freeze-dried and sterile pre-hydrated acellular dermal matrix in tissue expander/implant breast reconstruction
Jeong Hyun CHEON ; Eul Sik YOON ; Jin Woo KIM ; Seung Ha PARK ; Byung Il LEE
Archives of Plastic Surgery 2019;46(3):204-213
BACKGROUND: In implant-based breast reconstruction, acellular dermal matrix (ADM) is essential for supporting the inferolateral pole. Recent studies have compared non-sterilized freeze-dried ADM and sterilized pre-hydrated ADM, but have not assessed whether differences were attributable to factors related to sterile processing or packaging. This study was conducted to compare the clinical outcomes of breast reconstruction using two types of sterile-processed ADMs. METHODS: Through a retrospective chart review, we analyzed 77 consecutive patients (85 breasts) who underwent tissue expander/implant breast reconstruction with either freeze-dried ADM (35 breasts) or pre-hydrated ADM (50 breasts) from March 2016 to February 2018. Demographic variables, postoperative outcomes, and operative parameters were compared between freeze-dried and pre-hydrated ADM. Biopsy specimens were obtained for histologic analysis. RESULTS: We obtained results after adjusting for variables found to be significant in univariate analyses. The total complication rate for freeze-dried and pre-hydrated ADMs was 25.7% and 22.0%, respectively. Skin necrosis was significantly more frequent in the freeze-dried group than in the pre-hydrated group (8.6% vs. 4.0%, P=0.038). All other complications and operative parameters showed no significant differences. In the histologic analysis, collagen density, inflammation, and vascularity were higher in the pre-hydrated ADM group (P=0.042, P=0.006, P=0.005, respectively). CONCLUSIONS: There are limited data comparing the outcomes of tissue expander/implant breast reconstruction using two types of sterile-processed ADMs. In this study, we found that using pre-hydrated ADM resulted in less skin necrosis and better integration into host tissue. Pre-hydrated ADM may therefore be preferable to freeze-dried ADM in terms of convenience and safety.
Acellular Dermis
;
Biopsy
;
Breast Implants
;
Breast
;
Collagen
;
Female
;
Humans
;
Inflammation
;
Mammaplasty
;
Necrosis
;
Product Packaging
;
Retrospective Studies
;
Skin
;
Sterilization
8.Finite element analysis of long-term changes of the breast after augmentation mammoplasty: Implications for implant design
Yujin MYUNG ; Jong Gu LEE ; Maenghyo CHO ; Chan Yeong HEO
Archives of Plastic Surgery 2019;46(4):386-389
The development of breast implant technology continues to evolve over time, but changes in breast shape after implantation have not been fully elucidated. Thus, we performed computerized finite element analysis in order to better understand the trajectory of changes and stress variation after breast implantation. The finite element analysis of changes in breast shape involved two components: a static analysis of the position where the implant is inserted, and a dynamic analysis of the downward pressure applied in the direction of gravity during physical activity. Through this finite element analysis, in terms of extrinsic changes, it was found that the dimensions of the breast implant and the position of the top-point did not directly correspond to the trajectory of changes in the breast after implantation. In addition, in terms of internal changes, static and dynamic analysis showed that implants with a lower top-point led to an increased amount of stress applied to the lower thorax. The maximum stress values were 1.6 to 2 times larger in the dynamic analysis than in the static analysis. This finding has important implications for plastic surgeons who are concerned with long-term changes or side effects, such as bottoming-out, after anatomic implant placement.
Breast Implantation
;
Breast Implants
;
Breast
;
Computer Simulation
;
Female
;
Finite Element Analysis
;
Gravitation
;
Mammaplasty
;
Motor Activity
;
Plastics
;
Surgeons
;
Thorax
9.Characteristics of adhesion areas between the tissue expander and capsule in implant-based breast reconstruction
Yoon Min LIM ; Kwang Hyun PARK ; Dong Won LEE ; Dae Hyun LEW ; Tai Suk ROH ; Seung Yong SONG
Archives of Plastic Surgery 2019;46(4):330-335
BACKGROUND: The use of anatomic implants has improved the aesthetic results of breast surgery; however, implant malrotation is an uncommon, but serious complication of these procedures. Nevertheless, little research has explored implant adhesion. In this study, we investigated adhesion between the expander and the capsule. METHODS: Seventy-nine cases of immediate breast reconstruction via two-stage implant-based reconstruction performed between September 2016 and November 2017 were evaluated. Mentor CPX4 expanders were used in 14 breasts, and Natrelle expanders in 65. We analyzed areas of adhesion on the surfaces of the tissue expanders when they were exchanged with permanent implants. We investigated whether adhesions occurred on the cephalic, caudal, anterior, and/or posterior surfaces of the expanders. RESULTS: Total adhesion occurred in 18 cases, non-adhesion in 15 cases, and partial adhesion in 46 cases. Of the non-adhesion cases, 80% (n=12) were with Mentor CPX4 expanders, while 94.4% (n=17) of the total adhesion cases were with Natrelle expanders. Of the partial adhesion cases, 90.7% involved the anterior-cephalic surface. The type of tissue expander showed a statistically significant relationship with the number of attachments in both univariate and multivariate logistic regression analyses (P<0.001) and with total drainage only in the univariate analysis (P=0.015). CONCLUSIONS: We sought to identify the location(s) of adhesion after tissue expander insertion. The texture of the implant was a significant predictor of the success of adhesion, and partial adhesion was common. The anterior-cephalic surface showed the highest adhesion rate. Nevertheless, partial adhesion suffices to prevent unwanted rotation of the expander.
Breast Implantation
;
Breast Implants
;
Breast
;
Drainage
;
Female
;
Humans
;
Logistic Models
;
Mammaplasty
;
Mentors
;
Tissue Expansion Devices
10.The Goldilocks technique: An alternative method to construct a breast mound after prosthetic breast reconstruction failure
Karina Jaikel ZAVALA ; Jin Geun KWON ; Hyun Ho HAN ; Eun Key KIM ; Jin Sup EOM
Archives of Plastic Surgery 2019;46(5):475-479
The Goldilocks technique for breast reconstruction utilizes redundant mastectomy flap tissue to construct a breast mound. This technique is suitable for women who decline, or are poor candidates for, traditional postmastectomy reconstruction. Moreover, this technique can be applied in secondary operations after the failure of initial reconstruction efforts. A 74-year-old patient underwent the Goldilocks procedure after reconstruction failure with an implant and acellular dermal matrix. At her 6-month follow-up, the cosmetic outcome of the procedure was satisfactory, and no complications were noted. Therefore, the Goldilocks procedure is a safe alternative to reconstruct breast mounds following reconstruction failure, especially in obese patients.
Acellular Dermis
;
Aged
;
Breast Implants
;
Breast
;
Female
;
Follow-Up Studies
;
Humans
;
Mammaplasty
;
Mastectomy
;
Methods
;
Seroma

Result Analysis
Print
Save
E-mail