Reliability of the Action Research Arm Test in Stroke Patients
	    		
	    			
	    			
		        		
			        		
		        		
			        
		   		
		   		
	    	
    	 
    	
   		
        
        	
        		- VernacularTitle:上肢动作研究量表在脑卒中患者中的信度
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Changshui WENG
			        		
			        		;
		        		
		        		
		        		
			        		Jun WANG
			        		
			        		;
		        		
		        		
		        		
			        		Gang WANG
			        		
			        		;
		        		
		        		
		        		
			        		Zengzhi YU
			        		
			        		;
		        		
		        		
		        		
			        		Tong SUN
			        		
			        		;
		        		
		        		
		        		
			        		Liping GAO
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		action research arm test(ARAT), stroke, reliability
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Rehabilitation Theory and Practice
	            		
	            		 2007;13(9):868-869
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To verify the inter-rater reliability,intra-rater reliability and internal reliability of the action research arm test(ARAT)in patients with chronic stroke.Methods 30 people with chronic stroke were tested with the ARAT by two experienced raters.The inter-rater reliability,intra-rater reliability and internal reliability were examined.Results The ARAT showed high inter-rater reliability and intra-rater reliability(ICC=0.992 and 0.987,respectively)and internal consistency(Cronbach's alpha coefficient=0.936).Conclusion The ARAT shows good inter-rater reliability,intra-rater reliability and internal reliability in assessing patients after stroke.