The Use of a Pipeline Embolization Device for Treatment of a Ruptured Dissecting Middle Cerebral Artery M3/M4 Aneurysm: Challenges and Technical Considerations
	    		
		   		
		   			
		   		
	    	
    	 
    	10.5469euroint.2022.00045
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Robert P. BERWANGER
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Madeline C. HOOVER
			        		
			        		;
		        		
		        		
		        		
			        		John A. SCOTT
			        		
			        		;
		        		
		        		
		        		
			        		Andrew J. DENARDO
			        		
			        		;
		        		
		        		
		        		
			        		Krishna AMULURU
			        		
			        		;
		        		
		        		
		        		
			        		Troy D. PAYNER
			        		
			        		;
		        		
		        		
		        		
			        		Charles G. KULWIN
			        		
			        		;
		        		
		        		
		        		
			        		Daniel H. SAHLEIN
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Department of Neurosurgery, Indiana University School of Medicine, Indianapolis, IN, USA
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Case Report
 
        	
        	
            
            
            	- From:Neurointervention
	            		
	            		 2022;17(2):126-130
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	 Prompt, effective treatment is necessary following aneurysmal subarachnoid hemorrhage to prevent recurrent rupture, which is thought to double mortality. Atypical ruptured aneurysms, such as blister or dissecting pseudoaneurysms, or those that are unusually distal in the middle cerebral artery (MCA) are challenging to treat with either open or endovascular options, though the pipeline embolization device (PED) has shown promise in multiple case series. We present a case of a ruptured dissecting pseudoaneurysm in the distal MCA (distal M3/proximal M4) prefrontal division in an healthy young patient (<60 years) successfully treated with a PED. The PED was chosen both as the only vessel sparing option in the young patient as well as for its potential as a vessel sacrifice tool if the pseudoaneurysm was felt to be incompletely treated, which in this case was not necessary—though would have leveraged the thrombogenicity of the device as a therapeutic advantage.