In-vitro investigation of the mechanical friction properties of a computer-aided design and computer-aided manufacturing lingual bracket system under diverse tooth displacement condition
	    		
		   		
		   			
		   		
	    	
    	 
    	10.4041/kjod.2019.49.2.73
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Do Yoon KIM
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Sang Woon HA
			        		
			        		;
		        		
		        		
		        		
			        		Il Sik CHO
			        		
			        		;
		        		
		        		
		        		
			        		Il Hyung YANG
			        		
			        		;
		        		
		        		
		        		
			        		Seung Hak BAEK
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Private Practice, Suncheon, Korea.
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
            
            
            	- From:The Korean Journal of Orthodontics
	            		
	            		 2019;49(2):73-80
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	 OBJECTIVE:The purpose of this study was to compare the static (SFF) and kinetic frictional forces (KFF) of a computer-aided design and computer-aided manufacturing lingual bracket (CAD/CAM-LB) with those of conventional LB (Con-LB) and Con-LB with narrow bracket width (Con-LB-NBW) under 3 tooth displacement conditions.
				        	
				        
				        	METHODS:The samples were divided into 9 groups according to combinations of 3 LB types (CAD/CAM-LB [Incognito], Con-LB [7th Generation, 7G], and Con-LB-NBW [STb]) with 3 displacement conditions (no displacement [control], maxillary right lateral incisor with 1-mm palatal displacement [MXLI-PD], and maxillary right canine with 1-mm gingival displacement [MXC-GD]; n = 6/group). While drawing a 0.016-inch copper or super-elastic nickel-titanium archwire with 0.5 mm/min for 5 minutes in a chamber maintained at 36.5℃, SFF and KFF were measured. The Kruskal-Wallis method with Bonferroni correction was performed.
				        	
				        
				        	RESULTS:The Incognito group demonstrated the highest SFF, followed by the 7G and STb groups ([STb-control, STb-MXLI-PD, Stb-MXC-GD] < [7G-MXC-GD, 7G-MXLI-PD, 7G-control] < [Incognito-MXLI-PD, Incognito-control, Incognito-MXC-GD]; p < 0.001). However, there were no significant differences in SFF among the 3 displacement conditions within each bracket group. Within each displacement condition, the Incognito group demonstrated the highest KFF, followed by the 7G and STb groups ([STb-control, STb-MXLI-PD] < Stb-MXC-GD < 7G-MXLI-PD < [7G-control, 7G-MXC-GD] < [7G-MXC-GD, Incognito-MXLI-PD, Incognito-control] < [Incognito-control, Incognito-MXC-GD]; p < 0.001). MXC-GD exhibited higher KFFs than MXLI-PD in the same bracket group.
				        	
				        
				        	CONCLUSIONS:The slot design and ligation method of the CAD/CAM-LB system should be modified to reduce SFF and KFF during the leveling/alignment stage.