Determination of the Contents of Heavy Metals and Harmful Elements in Pediatric ,Paracetamol,Atificial Cow- bezoar and Chlorphenamine Maleate Granules by ICP-MS
- VernacularTitle:ICP-MS法测定小儿氨酚黄那敏颗粒中重金属及有害元素的含量
- Author:
Shuang PENG
1
;
Haiyuan YANG
1
;
Minjuan ZHANG
1
;
Wenzhi WEI
2
Author Information
1. Qinghai Provincial Drug Inspection and Testing Institute,Xining 810016,China;NMPA Key Laboratory for Quality Control of TCM (Tibetan Medicine ),Xining 810016,China;Qinghai Provincial Key Laboratory of Modernization of Traditional Chine se and Tibetan Medicine,Xining 810016,China
2. Qinghai Provincial Drug Inspection and Testing Institute,Xining 810016,China;NMPA Key Laboratory for Quality Control of TCM (Tibetan Medicine ),Xining 810016,China
- Publication Type:Journal Article
- Keywords:
Pediatric paracetamol artificial cow-bezoar and chlorphenamine maleate granules;
ICP-MS;
Heavy metals
- From:
China Pharmacy
2021;32(18):2218-2222
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To es tablish a method for the content determination of heavy metals [lead (Pb),cadmium(Cd), copper (Cu), mercury (Hg)] and harmful elements [arsenic (As)] in Pediatric paracetamol artificial cow-bezoar and chlorphenamine maleate granules. METHODS :The samples were conducted pretreatment by microwave digestion instrument and determined by inductively coupled plasma mass spectrometry (ICP-MS)using elements germanium ,indium,bismuth as internal standard. RESULTS :The linear ranges of Pb ,As,Cu,Cd and Hg were 1-20,0.5-10,5-100,0.5-10 and 0.2-4 ng/mL, respectively (all r>0.997). The limits of detection (LODs) were 0.041 1,0.013 2,0.057 3,0.009 0,0.005 4 ng/mL, respectively. The limits of quantification (LOQs)were 0.137 0,0.044 0,0.191 0,0.030 0,0.018 0 ng/mL,respectively. RSDs of precision and repeatability tests were all less than 6%. RSDs of stability tests (28 h)of Pb ,As,Cu and Cd were all less than 5%, and that of stability test (28 h)of Hg was less than 7%. The average recoveries were 89.44%(RSD=5.87%,n=9),99.56% (RSD=5.46% ,n=9),96.12%(RSD=4.62% ,n=9),105.82%(RSD=2.80% ,n=9)and 90.23%(RSD=3.59% ,n=9), respectively. Five elements were all detected in 63 batches of samples ,and the contents of them were 0.191 0-1.527 6,0.002 5- 0.047 4,0.034 1-1.549 0,0.001 5-0.078 8 and 0.001 9-0.005 4 mg/kg,respectively. CONCLUSIONS :The method is simple , sensitive and accurate. It is suitable for simultaneous determination of 5 elements in Pediatric paracetamol artificial cow-bezoar and chlorphenamine maleate granules.