IImprovement of pretreatment method for detection of lead, manganese and their inorganic compounds in the air of workplace by flame atomic absorption spectrometry 
	    		
		   		
		   			
		   		
	    	
    	 
    	10.11763/j.issn.2095-2619.2020.05.015
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Zhanhong YANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Chuang WU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Xiaoting LUO
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Ming DONG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Aihua ZHANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Banghua WU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Guangdong Province Hospital for Occupational Disease Prevention and Treatment;Guangdong Provincial Key Laboratory of Occupational Disease Prevention and Treatment Guangzhou, Guangdong 510300, China
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Pretreatment;
			        		
			        		
			        		
				        		Acid digestion;
			        		
			        		
			        		
				        		Lead and its inorganic compounds;
			        		
			        		
			        		
				        		Manganese and its inorganic compounds;
			        		
			        		
			        		
				        		Flame atomic absorption spectrometry;
			        		
			        		
			        		
				        		Workplace;
			        		
			        		
			        		
				        		Air
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			China Occupational Medicine
	            		
	            		 2020;47(05):582-585
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	 OBJECTIVE: To improve the pretreatment method for the detection of lead, manganese and their inorganic compounds in workplace air samples by flame atomic absorption spectrometry. METHODS: In this method, 20.0 mL of 1.0-2.0 mol/L nitric acid solution was used as the digestion solution to digest the microporous membrane sample at 140-160 ℃ to a volume of 0.5-1.0 mL. Samples were cooled and fixed to 10 mL and detected by flame atomic absorption spectrometry method. RESULTS: The lead detection had a good linear relationship in the range of 0.10-3.00 mg/L. The correlation coefficient was 0.999 5, the detection limit and the lower limit of quantification were 0.03 and 0.10 mg/L respectively(calculated by 3 and 10 times of standard deviation respectively). The minimum detection concentration was 0.004 mg/m~3, and the minimum quantitative concentration was 0.010 mg/m~3(collected by 75 L air calculation). The manganese detection had a good linear relationship in the range of 0.05-3.00 mg/L mass concentration. The correlation coefficient was 0.999 8, the detection limit and the lower limit of quantification were 0.015 and 0.05 mg/L respectively(calculated by 3 and 10 times of standard deviation respectively), the minimum detection concentration was 0.002 mg/m~3, and the minimum quantitative concentration was 0.007 mg/m~3(based on collection 75 L air calculation). The recovery rate of standard addition was 97.8%-99.6%, and the relative standard deviation within and between run were 0.4%-2.0% and 0.4%-1.7% respectively. CONCLUSION: The method is simple, the reagent consumption is small, the digestion temperature is low, the precision and accuracy are high. This method is suitable for widespread use.