Simultaneous detection of five kinds of olefine chlorides in workplace air by solvent desorption-gas chromatography 
	    		
		   		
		   			
		   		
	    	
    	 
    	10.11763/j.issn.2095-2619.2018.02.019
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Siyan LI
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yuanqin ZHONG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Lihe YE
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Dongguan Prevention and Treatment Center for Occupational Disease Dongguan,Guangdong 523008,China
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Olefine chlorides;
			        		
			        		
			        		
				        		Workplace;
			        		
			        		
			        		
				        		Air;
			        		
			        		
			        		
				        		Solvent desorption;
			        		
			        		
			        		
				        		Gas chromatography
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			China Occupational Medicine
	            		
	            		 2018;45(02):223-226
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	 OBJECTIVE: To establish a method for simultaneous detection of five kinds of olefine chlorides in workplace air by solvent desorption-gas chromatography. METHODS: The olefine chlorides in workplace air were collected using activated charcoal tubes,desorbed by carbon disulfide,separated on a HP-INNOWAX capillary column and detected with flame ionization detector. RESULTS: The linear range of the five kinds of chlorinated olefins( vinyl chloride,allyl chloride,chloroprene,trans-1, 2-dichloroethylene, cis-1, 2-dichloroethene) was wide and the linear correlation coefficient was greater than 0. 999 8. The detection limit and the minimum detectable concentrations were 0. 30-0. 80 mg/L and 0. 05-0. 13 mg/m~3,respectively( air sample volume 6. 0 L). The recovery rate was 95. 90%-102. 67%. The within-run and betweenrun relative standard deviations were 0. 00%-3. 74% and 0. 21%-6. 12%,respectively. The samples could be preserved at room temperature for at least 14 days. CONCLUSION: This method has simple operation,good linear range,high sensitivity and good reproducibility,which is suitable for detecting 5 kinds of olefine chlorides in workplace air.