- VernacularTitle:陕西省饮用水中锰检测能力验证结果分析
 - Author:
	        		
		        		
		        		
			        		Yu LIU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Wenting YUAN
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Caixia WANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Guoxia CHENG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Xiaoling NIE
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Xiaocong LIANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Tianlai LI
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		
		        		
		        		
		        		
			        		
			        		Author Information
			        		
 - Publication Type:Journal Article
 - Keywords: Drinking water; Manganese; Proficiency test; Z-score
 - From: Journal of Public Health and Preventive Medicine 2021;32(2):26-29
 - CountryChina
 - Language:Chinese
 - Abstract: Objective To understand and improve the laboratory detection capacity of water manganese in testing organizations of Shaanxi Province. Methods The self-made manganese capacity testing samples were used as the reference in this proficiency testing program. The homogeneity of the samples was tested by single factor analysis of variance. The t-test method was used to evaluate the stability of the samples. The results of manganese in water provided by participant laboratories were analyzed by the robust statistical technique Z-score. Results A total of 136 laboratories participated in the proficiency testing program throughout the province. Among them, 129 laboratories (including retest laboratory) or 94.85% of total participating laboratories obtained satisfactory results. Conclusion The water quality monitoring agencies of our province had shown a strong detection capability for the determination of metal elements in drinking water, which ensures to provide safe water supply to the residents in Shaanxi Province.
 
            