Changes in Vestibular Symptoms and Function After Cochlear Implantation: Relevant Factors and Correlations With Residual Hearing
	    		
		   		
		   			
		   		
	    	
    	- Author:
	        		
		        		
		        		
			        		Jeong Hun JANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Hantai KIM
			        		
			        		;
		        		
		        		
		        		
			        		Oak-Sung CHOO
			        		
			        		;
		        		
		        		
		        		
			        		Hun Yi PARK
			        		
			        		;
		        		
		        		
		        		
			        		Yun-Hoon CHOUNG
			        		
			        		
		        		
		        		
		        		
			        		
			        		Author Information
			        		
 - Publication Type:Original Article
 - From:Clinical and Experimental Otorhinolaryngology 2021;14(1):69-75
 - CountryRepublic of Korea
 - Language:English
 - 
		        	Abstract:
			       	
			       		
				        
				        	 Objectives:. The aim of this study was to evaluate vestibular function loss after cochlear implantation (CI) and the relationship between vestibular function and hearing changes. 
				        	
Methods:. Seventy-five patients with CI were enrolled and divided into those with normal preoperative caloric function (group I) and those with a normal preoperative waveform in cervical vestibular evoked myogenic potential (c-VEMP) testing (group II). The relationship between hearing and changes in the vestibular system was analyzed preoperatively and at 3 and 6 months postoperatively.
Results:. In group I, unilateral weakness on the implanted side was detected in five (7.7%) and eight (12.3%) patients at 3 and 6 months post-CI, respectively. By 3 months post-CI, the total slow-phase velocity (SPV; warm and cold stimulations) was significantly different between the implanted and non-implanted sides (P=0.011), and the shift in total SPV from pre- to post-CI was significantly correlated with the average hearing threshold at 6 months post-CI. In group II, an abnormal c-VEMP was detected on the implanted side in six patients (16.2%) at 3 months post-CI, and in six patients (16.2%) at 6 months post-CI. Significant changes were noticed in the P1 and N1 amplitude at 3 months postCI (P=0.027 and P=0.019, respectively).
Conclusion:. Vestibular function and residual hearing function should be afforded equal and simultaneous consideration in terms of preservation. 
            