A Pilot Study of Sequential Capsule Endoscopy Using MiroCam and PillCam SB Devices with Different Transmission Technologies.
	    		
		   		
	    	
    	
    	
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Hee Man KIM
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yoon Jae KIM
			        		
			        		;
		        		
		        		
		        		
			        		Hong Jeong KIM
			        		
			        		;
		        		
		        		
		        		
			        		Semi PARK
			        		
			        		;
		        		
		        		
		        		
			        		Jeong Youp PARK
			        		
			        		;
		        		
		        		
		        		
			        		Sung Kwan SHIN
			        		
			        		;
		        		
		        		
		        		
			        		Jae Hee CHEON
			        		
			        		;
		        		
		        		
		        		
			        		Sang Kil LEE
			        		
			        		;
		        		
		        		
		        		
			        		Yong Chan LEE
			        		
			        		;
		        		
		        		
		        		
			        		Seung Woo PARK
			        		
			        		;
		        		
		        		
		        		
			        		Seungmin BANG
			        		
			        		;
		        		
		        		
		        		
			        		Si Young SONG
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Division of Gastroenterology, Department of Internal Medicine and Yonsei Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea. sysong@yuhs.ac
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Capsule endoscopy;
			        		
			        		
			        		
				        		Gastrointestinal hemorrhage;
			        		
			        		
			        		
				        		Feasibility study;
			        		
			        		
			        		
				        		Diagnosis
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Capsule Endoscopy;
				        		
			        		
				        		
					        		Capsules;
				        		
			        		
				        		
					        		Cecum;
				        		
			        		
				        		
					        		Feasibility Studies;
				        		
			        		
				        		
					        		Fluoroscopy;
				        		
			        		
				        		
					        		Gastrointestinal Hemorrhage;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		Pilot Projects
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:Gut and Liver
	            		
	            		 2010;4(2):192-200
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	BACKGROUND/AIMS: Studies have investigated the use of different types of radiofrequency capsules for comparison or sequential capsule endoscopy, but none have compared the MiroCam device - which utilizes a novel data transmission technology - with other capsules. This study compared the feasibility of sequential capsule endoscopy using the MiroCam and PillCam SB devices, which employ different transmission technologies. METHODS: Patients with diseases requiring capsule endoscopy were enrolled. After a 12-hour fast, one randomly selected capsule was swallowed. The second capsule was swallowed once fluoroscopy had indicated that the first capsule had migrated below the gastric outlet. RESULTS: The total operating time in 24 patients was 702+/-60 min (mean+/-SD) for the MiroCam and 446+/-28 min for the PillCam SB (p<0.0001). The rate of a complete examination to the cecum was 83.3% for the MiroCam and 58.3% for the PillCam SB (p=0.031). Diagnostic yields for the MiroCam, PillCam SB, and sequential capsule endoscopy were 45.8%, 41.7%, and 50.0%, respectively. The agreement rate between the two capsules was 87.5%, with a kappa value of 0.74. Electrical interference in data transmission between the two capsules was not observed, but temporary visual interferences were observed in seven patients (29.2%). CONCLUSIONS: Sequential capsule endoscopy with the MiroCam and PillCam SB produced slight but nonsignificant increases in the diagnostic yield, and the two capsules did not exhibit electrical interference. A larger trial is necessary for elucidating the usefulness of sequential capsule endoscopy.