Value of SPECT/CT in Diagnostic I-131 MIBG Scintigraphy in Patients with Neuroblastoma
	    		
		   		
		   			
		   		
	    	
    	 
    	10.1007/s13139-018-0532-y
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Daris THEERAKULPISUT
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yutapong RARUENROM
			        		
			        		;
		        		
		        		
		        		
			        		Nantaporn WONGSURAWAT
			        		
			        		;
		        		
		        		
		        		
			        		Charoonsak SOMBOONPORN
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Khon Kaen University, 123 Mittraparp highway, Muang, Khon Kaen 40002, Thailand. daris.th@gmail.com yutapongkku@gmail.com dr.nantaporn@gmail.com charoonsak.som@gmail.com
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Diagnostic I-131 MIBG scintigraphy;
			        		
			        		
			        		
				        		MIBG;
			        		
			        		
			        		
				        		Neuroblastoma;
			        		
			        		
			        		
				        		Radionuclide imaging;
			        		
			        		
			        		
				        		SPECT/CT
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		3-Iodobenzylguanidine;
				        		
			        		
				        		
					        		Diagnosis;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		Neuroblastoma;
				        		
			        		
				        		
					        		Radionuclide Imaging;
				        		
			        		
				        		
					        		Retrospective Studies
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:Nuclear Medicine and Molecular Imaging
	            		
	            		 2018;52(5):350-358
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	PURPOSE: Diagnostic I-131 MIBG scintigraphy is an important imaging modality for evaluation of patients with neuroblastoma (NB) especially in centers where I-123 MIBG is not available. Single photon emission computed tomography/computed tomography (SPECT/CT) could potentially improve lesion detection over planar scintigraphy, but studies regarding its usefulness as an add-on to diagnostic I-131 MIBG scintigraphy are limited. This study aimed to determine the usefulness and factors related to usefulness of SPECT/CT in diagnostic I-131 MIBG scintigraphy in NB patients.METHODS: Usefulness of SPECT/CT for lesion detection, lesion localization, resolving suspicious findings, and clarifying the nature of lesions on anatomical imaging were retrospectively reviewed in 86 diagnostic planar I-131 MIBG scintigrams with add-on SPECT/CT.RESULTS: SPECT/CT detected additional lesions in 23.2%(20/86), helped localize lesions in 21.1%(8/38), resolved suspicious findings in 85.7%(6/7), determined functional status of lesions on anatomical imaging in 94.4%(17/18), and changed diagnosis from a negative to a positive study in 19.5%(8/41). Independent predictors of SPECT/CT being useful included presence of suspicious findings on planar imaging (OR 99.08; 95% C.I. 6.99–1404.41; p = 0.001), positive findings on planar imaging (OR 4.61; 95% C.I. 1.05, 20.28; p < 0.001), and presence of structural lesions on anatomical imaging (OR 32.54; 95% C.I. 5.37–196.96; p < 0.001).CONCLUSION: SPECT/CT is a useful add-on to diagnostic planar I-131 MIBG scintigraphy. Predictors of usefulness of SPECT/CT include suspicious or positive findings on planar scintigraphy and the presence of structural lesions on anatomical imaging.