The applicability of sound touch elastography and sound touch quantify in measuring liver and spleen stiffness
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1004‐4477.2019.07.008
   		
        
        	
        		- VernacularTitle:声触诊弹性成像和声触诊弹性测量检测肝、脾硬度可行性研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Jian ZHENG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Manli WU
			        		
			        		;
		        		
		        		
		        		
			        		Mei ZHONG
			        		
			        		;
		        		
		        		
		        		
			        		Siyuan ZOU
			        		
			        		;
		        		
		        		
		        		
			        		Rizhen GU
			        		
			        		;
		        		
		        		
		        		
			        		Lexiang LONG
			        		
			        		;
		        		
		        		
		        		
			        		Siliang KANG
			        		
			        		;
		        		
		        		
		        		
			        		Jie ZENG
			        		
			        		;
		        		
		        		
		        		
			        		Rongqin ZHENG
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 深圳市龙岗区第三人民医院超声科 518115
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Sound touch elastography;
			        		
			        		
			        		
				        		Sound touch quantify;
			        		
			        		
			        		
				        		Liver stiffness;
			        		
			        		
			        		
				        		Spleen stiffness
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Ultrasonography
	            		
	            		 2019;28(7):617-620
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To assess the applicability of sound touch elastography ( ST E) and sound touch quantify ( ST Q ) in measuring liver and spleen stiffness . Methods One hundred and eighteen healthy volunteers were included and underwent ST E and ST Q . T he success rate ,variability and reproducibility of ST E and ST Q were analyzed . T he accurate sampling size and number of tests for liver ST Q were also analyzed . Results T he success rates ,variability ,reproducibility of ST E and ST Q in liver were 97 .5% and 99 .2% ,8 .7% and 12 .0% ,0 .917 and 0 .916 , respectively . While those with spleen were 76 .3% and 66 .9% ,12 .4% and 16 .4% ,0 .847 and 0 .706 ,respectively . The sampling size of 1 .5 cm×1 .0 cm yield the lowest variability ( 8 .5% ) ( F =6 .562 , P =0 .002) ,and there was no significant difference between results of detecting 5 times and 10 times( P =0 .571) . T he liver and spleen stiffness of ST E were 5 .75 kPa ( 95%CI :5 .60-5 .91 kPa) and 15 .58 kPa ( 95% CI :14 .99 -16 .16 kPa) . Conclusions The measurement of liver stiffness using both ST E and ST Q have a high success rate and low variability . However ,ST E is better than STQ in measuring spleen stiffness .