Simultaneous determination of Forsythoside A and other four components in Xiao'er-Ganmao-Keli from multivendor by HPLC
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1673-4246.2019.07.016
   		
        
        	
        		- VernacularTitle:HPLC法对多厂家小儿感冒颗粒中连翘酯苷A等5种成分的含量分析
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Wei YANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Tao GONG
			        		
			        		;
		        		
		        		
		        		
			        		Xia WANG
			        		
			        		;
		        		
		        		
		        		
			        		Qing ZHU
			        		
			        		;
		        		
		        		
		        		
			        		Yinyan HU
			        		
			        		;
		        		
		        		
		        		
			        		Jingmei SONG
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 北京市卫生局临床药学研究所 100035
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Xiao Er Gan Mao Ke Li;
			        		
			        		
			        		
				        		Forsythoside A;
			        		
			        		
			        		
				        		Phillyrin;
			        		
			        		
			        		
				        		(R,S)-Epigoitrin;
			        		
			        		
			        		
				        		Chlorgenic Acid;
			        		
			        		
			        		
				        		Isochlorogenic Acid A;
			        		
			        		
			        		
				        		HPLC
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			International Journal of Traditional Chinese Medicine
	            		
	            		 2019;41(7):745-751
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To establish a method for the simultaneous determination of Forsythoside A, Phillyrin, (R,S)-Epigoitrin, Chlorgenic Acid and Isochlorogenic Acid A by HPLC, and test 16 batches of samples from 14 manufacturers. Methods The test was performed on Kinetex EVO C18 column (150 mm × 4.6 mm, 5 μm) with the column temperature at 35 ℃ . The gradient elution was adopted with the mobile phase of acetonitrile and 0.3% phosphoric acid aqucous at a flow rate of 1.0 ml/min. The detection wavelength of (R,S)-Epigoitrin and Phillyrin were set as 236 nm, the detection wavelength of Forsythoside A, Cholorogenic Acid and Isochlorogenic Acid A were set as 327 nm. Results The good linear relationships were displayed within the linear range of 0.050 45-2.018 00 μg for Forsythoside A (r=0.999 9), 0.018 21-0.728 40 μg for Phillyrin (r=0.999 9), 0.010 16-0.406 40 μg for (R,S)-Epigoitrin (r=0.999 9), 0.006 60-0.263 90 μg for Cholorogenic Acid (r=0.999 9) and 0.0040 44~0.161 76 μg for Isochlorogenic Acid A ( r=0.999 5). The RSDs of reproducibility and stability tests were lower than 2%; recoveries were 97.01%, 98.28%, 99.35% and 96.21%, RSD were 3.19%, 1.19%, 0.81%, 2.88% and 2.96%. The content ranges of Forsythoside A, Phillyrin, (R,S)-Epigoitrin, Chlorgenic Acid and Isochlorogenic Acid A from 16 batches of samples from 14 manufacturers were 0.057 43-1.508 71 mg/g, 0.017 72-0.350 15 mg/g, 0.005 68-0.177 13 mg/g, 0.007 53-0.226 33 mg/g and 0.00308-0.11908 mg/g. Conclusions The established method is simple and accurate, and has a good repeatability. It can be used for the quality analysis of Forsythoside A, Phillyrin, (R,S)-Epigoitrin, Chlorgenic Acid and Isochlorogenic Acid A. The content of the tested chemical components from 16 batches of samples from 14 manufacturers have significant differences which indicate that a reinforcement of the quality control is needed.