Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study
	    		
		   		
		   			
		   		
	    	
    	 
    	10.4047/jap.2018.10.3.252
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Hee Kyung KIM
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Department of Dentistry, Ajou University School of Medicine, Suwon, Republic of Korea. denthk@naver.com
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Spectrophotometry;
			        		
			        		
			        		
				        		Color;
			        		
			        		
			        		
				        		Equipment failure analysis;
			        		
			        		
			        		
				        		Dimensional measurement accuracy
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Dimensional Measurement Accuracy;
				        		
			        		
				        		
					        		Equipment Failure Analysis;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		In Vitro Techniques;
				        		
			        		
				        		
					        		Incisor;
				        		
			        		
				        		
					        		Reading;
				        		
			        		
				        		
					        		Spectrophotometry;
				        		
			        		
				        		
					        		Tooth
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:The Journal of Advanced Prosthodontics
	            		
	            		 2018;10(3):252-258
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	PURPOSE: The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS: The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (α=.05). RESULTS: A high level of measurement repeatability (ICC>0.90) among L *, a *, and b * color components was observed within and between devices (P < .001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were 2.28±1.61 ΔE 00 for in-vivo readings. Regarding the clinical matching accuracy of both devices, ΔE 00 values between teeth and matching shade tabs were 3.05±1.19 and 2.86±1.02, respectively. CONCLUSION: Although two EasyShade V devices with different serial numbers show high repeatability of CIE L*, a*, and b* measurements, they could provide different color values and shade for the same tooth.