The predictive validity of fetal/embryonic heart monitoring during the first trimester in assessing the pregnancy outcomes
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1004-4477.2018.11.014
   		
        
        	
        		- VernacularTitle:超声监测早孕期胚胎心率对妊娠结局的预测价值
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Xiaoping GONG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Guanjie WANG
			        		
			        		;
		        		
		        		
		        		
			        		Haifei WANG
			        		
			        		;
		        		
		        		
		        		
			        		Xiaoxiao KONG
			        		
			        		;
		        		
		        		
		        		
			        		Tian YANG
			        		
			        		;
		        		
		        		
		        		
			        		Xiaorui LIU
			        		
			        		;
		        		
		        		
		        		
			        		Yunyun CAO
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 200030,上海交通大学医学院附属国际和平妇幼保健院超声科
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Ultrasonography;
			        		
			        		
			        		
				        		Heart rate,fetal;
			        		
			        		
			        		
				        		First trimester;
			        		
			        		
			        		
				        		Pregnancy outcome
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Ultrasonography
	            		
	            		 2018;27(11):982-985
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To explore the pregnancy outcomes in women whose fetal/embryonic heart rate( FHR) were below 120 beats per minute( bpm) before 8 weeks pregnancy and determine the predictive value of FHR in pregnancy outcome . Methods The laboratory examinations ,clinical data and clinical history of the pregnant women whose FHR were below 120 bpm before 8 weeks pregnancy were retrospectively analyzed . Results When gestational age(GA) was less than 8 weeks ,pregnancy loss was observed in 11 .0% ( 110/998 ) cases with an FHR less than or equal to 120 bpm ,and pregnancy loss occurred in all the cases ( 23/23) with an FHR less than or equal to 70 bpm . The proportions of first trimester loss were 86 .4% (19/22) for pregnancies with an FHR of 71 -80 bpm ,75 .7% (28/37) for pregnancies with an FHR of 81-90 bpm ,25 .5% (14/55) for pregnancies with an FHR of 91 -100 bpm , 6 .3% (13/208) for pregnancies with an FHR of 101 -110 bpm ,and 2 .0% (13/653) for pregnancies with an FHR of 111 -120 bpm .ROC analysis showed that the best cut-off value to predict adverse pregnancy outcomes was an FHR of 94 bpm . The area under the ROC curve was 0 .906 ( P < 0 .0001 ) and its sensitivity and specificity values were 97 .86% and 71 .43% respectively . Conclusions Fetal/embryonic heart monitoring before 8-weeks pregnancy can be an effective predictor for early pregnancy outcome . The best cut-off value to predict adverse pregnancy outcomes is an FHR of 94 bpm .