Internal fixation with elastic intramedullary nail versus plate-screw system for treatment of fibular diaphyseal fracture
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1671-7600.2018.02.015
   		
        
        	
        		- VernacularTitle:弹性髓内针与钢板螺钉治疗腓骨干骨折的比较研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Yun YANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yue FANG
			        		
			        		;
		        		
		        		
		        		
			        		Gang ZHONG
			        		
			        		;
		        		
		        		
		        		
			        		Lei LIU
			        		
			        		;
		        		
		        		
		        		
			        		Zhou XIANG
			        		
			        		;
		        		
		        		
		        		
			        		Fuguo HUANG
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 四川大学华西医院骨科
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Fibula;
			        		
			        		
			        		
				        		Fractures,Bone;
			        		
			        		
			        		
				        		Fracture fixation,internal;
			        		
			        		
			        		
				        		Bone nails;
			        		
			        		
			        		
				        		Bone plate
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Orthopaedic Trauma
	            		
	            		 2018;20(2):172-176
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To compare elastic intramedullary nail (EIN) and plate-screw (P+S) system in the treatment of fibular diaphyseal fractures. Methods From January 2014 to April 2017, 48 tibiofibular fractures were treated with internal fixation using EIN (21 cases) or plate-screw (27 cases). The 2 groups were compared in terms of intraoperative blood loss, operative time, fibular healing time, fibular union rate, ankle function and postoperative complications.Results All the patients were followed up for 3 to 24 months (average, 14.0 months). The intraoperative blood loss (17.9 ± 4.9 mL), operative time (23.2 ± 5.8 min) and fibular healing time(10.3 ± 1.8 weeks)for the EIN group were significantly less than those for the plate-screw group (28.9 ± 9.6 mL, 30.0 ± 10.7 min and 11.6 ± 2.0 weeks)(P <0.05). There were no significant differences be-tween the 2 groups in fibular union rate(95.2% versus 92.6%) or incision infection(0 versus 7.4%)(P> 0.05) . The AOFAS ankle-hindfoot scoring revealed 12 excellent, 8 good and one fair cases (91.0 ± 5.3 points on aver-age) in the EIN group, and 14 excellent, 10 good and 3 fair cases(90.1 ± 6.1 points on average) in the plate-screw group, showing no significant difference between the 2 groups(P=0.594). Conclusions Compared with plate-screw system, elastic intramedullary nail for fibular diaphyseal fractures may be in line with the biome-chanical characteristics of the fibula and with the basic principles of minimally invasive surgery. It may be ad-vantageous in blood loss, operative time and fracture healing but not in fibular union rate or functional recovery of the ankle. An appropriate way of internal fixation for a fibular diaphyseal fracture should be chosen according to the specific conditions of the patient.