Study on bone densities of tibial periprosthesis and contralateral interarticular compartment after unicompartment knee arthroplasty
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1673-4904.2018.03.007
   		
        
        	
        		- VernacularTitle:膝关节单髁置换术后胫骨假体周围及对侧关节间室骨密度变化的研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Zhiming QI
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Zi WANG
			        		
			        		;
		        		
		        		
		        		
			        		Jin LI
			        		
			        		;
		        		
		        		
		        		
			        		Shuang ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Zuohong LI
			        		
			        		;
		        		
		        		
		        		
			        		Qing LI
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 116033,大连市中心医院运动医学科
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Arthroplasty;
			        		
			        		
			        		
				        		replacement;
			        		
			        		
			        		
				        		knee;
			        		
			        		
			        		
				        		Bone density;
			        		
			        		
			        		
				        		Prosthesis implantation
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Postgraduates of Medicine
	            		
	            		 2018;41(3):215-218
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To study the postoperative bone densities of tibial periprosthesis and contralateral interarticular compartment, in order to provide references and data for clinical application and complication prevention of unicompartment knee arthroplasty(UKA). Methods The study adopted a prospective study method.Thirty-eight patients with knee osteoarthritis involving medial interarticular compartment were selected, and all patients were treated with UKA. The alignment of operated limb before operation and 1 week,3 months,6 months and 12 months after operation was measured.The bone densities of tibial periprosthesis and contralateral tibial metaphysis 1 week,3 months,6 months and 12 months after operation were measured. Results All patients underwent successful surgery. No patient had loosening of prosthesis, sinking of prosthesis and revision events caused by various causes during follow-up.There was no statistical difference in alignment of operated limb 1 week,3 months,6 months and 12 months after operation compared with that before operation(P>0.01).The bone densities of tibial periprosthesis 3, 6 and 12 months after operation were significantly lower than those 1 week after operation: (1.07 ± 0.05), (1.00 ± 0.04) and (0.99 ± 0.05) g/cm2vs. (1.15 ± 0.04) g/cm2, furthermore the bone densities 6 and 12 months after operation were significantly lower than those 3 months after operation,and there were statistical differences(P<0.01);but there was no statistical difference between 6 months after operation and 12 months after operation(P>0.01).There was no statistical difference in contralateral tibial metaphysis 3, 6 and 12 months after operation compared with that 1 week after operation(P>0.01).Conclusions Without fully alignment of operated limb correction,the bone density of tibial periprosthesis 1 year after UKA declines, but the bone density of contralateral interarticular compartment does not change significantly.